• Title/Summary/Keyword: slip capacity

Search Result 207, Processing Time 0.023 seconds

Characteristics Analysis of Induction Motor Power and Torque under the Efficiency & Slip Variation (효율 및 슬립 변화에 따른 유도전동기의 전력 및 토크 특성 분석)

  • Jeong, Jong-Ho;Lee, Eun-Woong;Kim, Il-Jung;Kim, Jong-Gyeum;Park, Young-Jeen
    • Proceedings of the KIEE Conference
    • /
    • 2007.04c
    • /
    • pp.43-45
    • /
    • 2007
  • This paper presents a analysis on the characteristics of induction motor under the efficiency & slip variance. An induction motor changes its characteristics parameters under the operation condition with the same capacity. In this paper, we analyzed that how the power and torque characteristics of induction motor would be changed according to the change of these parameters.

  • PDF

Mechanical Bar Anchorage of the PC Beam in Beam-Column Joint Using Plates and Bolts (지지대 및 제결볼트를 이용한 프리캐스트 콘크리트 골조구조의 보 하단 철근 정착공법 개발)

  • 유영찬;최근도;김긍환;이리형
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.04a
    • /
    • pp.539-544
    • /
    • 2000
  • The purpose of this study is to develop the mechanical anchorage, namely MAB-BOP (Mechanical Anchorage of 90$^{\circ}$ Hooked Bars with BOlt nad Plate) of the beam-column joint in precast concrete framed structures. Six specimens simulating typical interior beam-column joints were tested to investigate the mechanical characteristics of MAB-BOP. Of primary interest was the measurement of the slip of the anchored bar. Th load-slip curve obtained from this test were used to compare the mechanical performances of the different anchoring methods. Based on the test results, it was found that MAB-BOP showed sufficient anchoring strength capacity compared to 90$^{\circ}$ hooked bar method. So, MAB-BOP can be used as the anchoring methods of the reinforcing bars in PC beam-column joint.

  • PDF

The Hallym Slider: A New Arthroscopic Simple Sliding and One-Way Locking Knot (한림 Slider: 쉽게 미끄러지며 단 방향으로 잠김이 되는 새로운 관절경적 매듭)

  • Noh Kyu-Cheol;Chung Yung-Khee
    • Clinics in Shoulder and Elbow
    • /
    • v.8 no.2
    • /
    • pp.117-121
    • /
    • 2005
  • A secure slip knot is very important in the arthroscopic surgery of the shoulder joint. The new 'Hallym Slider', developed by the first author(KCN), has the properties of being a simple sliding and one-way locking knot. This technique can be performed alone without an assistant and has no accidental premature locking during the knot tying. The initial slip knot determines the adequacy of tissue approximation and consequent healing. The 'Hallym Slider' has excellent initial holding capacity, maintaining tension on soft tissue while additional half-hitches are being tied. It locks readily, it takes less time to tie than numerous square knots, and it is not as bulky as other knots. Therefore, we introduce this new sliding and one-way locking knot during the arthroscpic surgery of shoulder.

Development of a Rotational Torque Calibration System (회전 토크 교정장치 개발에 관한 연구)

  • 김갑순;권영하
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.10
    • /
    • pp.2646-2653
    • /
    • 1993
  • A rotational torque calibration system is developed to measure rotational torque of power generating systems and to calibrate non-contact rotational torque measurement systems. The maximum capacity of the developed system is 4.5 N-m. It is composed of a DC motor, a DC generator, a control system, a master torque cell, a slip ling/brush set, supporters, a bed etc. The control system is characterized by the closed-loop control with differential intergrator. Rotational torque measurement test and unit response test are conducted to estimate the accuracy of the developed system. It is found that system maintain high consistency and accuracy with the maximum error of 0.25%, Therefore the developed system can be used to measure the rotational torque of power generating systems and to calibrate non-contact rotational torque measurement systems.

A general method of analysis of composite beams with partial interaction

  • Ranzi, G.;Bradford, M.A.;Uy, B.
    • Steel and Composite Structures
    • /
    • v.3 no.3
    • /
    • pp.169-184
    • /
    • 2003
  • This paper presents a generic modelling of composite steel-concrete beams with elastic shear connection. It builds on the well-known seminal technique of Newmark, Siess and Viest, in order to formulate the partial interaction formulation for solution under a variety of end conditions, and lends itself well for modification to enable direct quantification of effects such as shrinkage, creep, and limited shear connection slip capacity. This application is possible because the governing differential equations are set up and solved in a fashion whereby inclusion of the kinematic and static end conditions merely requires a statement of the appropriate constants of integration that are generated in the solution of the linear differential equations. The method is applied in the paper for the solution of the well-studied behaviour of simply supported beams with partial interaction, as well as to provide solutions for a beam encastr$\acute{e}$ at its ends, and for a propped cantilever.

Solution of yielding steel arch supports used in mining

  • Lenka Koubova
    • Steel and Composite Structures
    • /
    • v.51 no.5
    • /
    • pp.575-586
    • /
    • 2024
  • Steel arch supports are used in mines and underground structures to provide stability. Most of the supports are made up of overlapping arches. They can behave either yieldingly or unyieldingly. If the normal force at any point of overlapping equals the slip resistance, the slide occurs. This paper presents a solution procedure for determining the load-carrying capacity of steel arch supports in the yielding implementation. This solution considers the effects of several significant elements, including differing materials and the number of clamps in yielding friction joints. The direct stiffness method is applied. The solution contains geometric, physical, and structural nonlinearity. The results obtained from numerical modeling using the provided procedure are compared to laboratory tests conducted at GIG Katowice in 2012. They show a good correlation with previously collected data from equivalent laboratory conditions.

Characteristics of a Coupled Gas Lubricated Bearing for a Scaled-Up Micro Gas Turbine

  • Lee, Yong Bok;Kwak, Hyunduck;Kim, Chang Ho;Jang, Gun Hee
    • KSTLE International Journal
    • /
    • v.1 no.2
    • /
    • pp.107-112
    • /
    • 2000
  • In case of the limitation of Deep RIE fabrication far Micro Gas Turbine, bearing aspect ratio is limited in very small value. The characteristics such as pressure distribution, load capacity and non-linearity of a short bearing of L/D=0.083 and a conventional bearing of L/D=1.0 with coupled boundary effects are investigated for Micro Gas Turbine bearings. The coupled effect was analyzed by mass conservation at coupled end area. The results, increasing load capacity and non-linearity due to the coupled effect of thrust and journal bearing, are obtained and the selection of journal bearing type is discussed.

  • PDF

Coupled Boundary Effects on a Gas Lubricated Bearing far a Scaled-Up Micro Gas Turbine

  • Hyunduck Kwak;Lee, Yong-Bok;Kim, Chang-Ho;Gunhee Jang
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.243-249
    • /
    • 2000
  • In case of the limitation of Deep RIE fabrication for Micro Gas Turbine, bearing aspect ratio is limited in very small value. The characteristics such as pressure distribution load capacity and non-linearity of a short bearing of L/D=0.083 and a conventional bearing of L/D=1.0 with coupled boundary effects are investigated far Micro Gas Tlubine bearings. The coupled efffect was analyzed by mass conservation at coupled end area. The results, increasing load capacity and non-linearity due to the coupled effect of thrust and journal bearing, are obtained and the selection of journal bearing type is discussed.

  • PDF

Investigation of shear transfer mechanisms in repaired damaged concrete columns strengthened with RC jackets

  • Achillopoulou, D.V;Karabinis, A.I
    • Structural Engineering and Mechanics
    • /
    • v.47 no.4
    • /
    • pp.575-598
    • /
    • 2013
  • The study presents the results of an experimental program concerning the shear force transfer between reinforced concrete (RC) jackets and existing columns with damages. In order to investigate the effectiveness of the repair method applied and the contribution of each shear transfer mechanism of the interface. It includes 22 concrete columns (core) (of 24,37MPa concrete strength) with square section (150mm side, 500 mm height and scale 1:2). Ten columns had initial construction damages and twelve were subjected to initial axial load. Sixteen columns have full jacketing at all four faces with 80mm thickness (of 31,7MPa concrete strength) and contain longitudinal bars (of 500MPa nominal strength) and closed stirrups spaced at 25mm, 50mm or 100mm (of 220MPa nominal strength). Fourteen of them contain dowels at the interface between old and new concrete. All columns were subjected to repeated (pseudo-seismic) axial compression with increasing deformation cycles up to failure with or without jacketing. Two load patterns were selected to examine the difference of the behavior of columns. The effects of the initial damages, of the reinforcement of the interface (dowels) and of the confinement generated by the stirrups are investigated through axial- deformation (slip) diagrams and the energy absorbed diagrams. The results indicate that the initial damages affect the total behavior of the column and the capacity of the interface to shear mechanisms and to slip: a) the maximum bearing load of old column is decreased affecting at the same time the loading capacity of the jacketed element, b) suitable repair of initially damaged specimens increases the capacity of the jacketed column to transfer load through the interface.

Analysis of the Load Carrying Behavior of Shear Connection at the Interface of Encased Composite Beams (매입형 합성보의 전단합성거동에 대한 비교분석)

  • Shin, Hyun Seop;Heo, Byung Wook;Bae, Kyu Woong;Kim, Keung Hwan
    • Journal of Korean Society of Steel Construction
    • /
    • v.20 no.1
    • /
    • pp.67-79
    • /
    • 2008
  • In this study, a bending test with three encased composite beams were carried out and analyzed using FEM in order to find how chemical adhesion, interface interlock, friction and composite action by shear studs contribute to stiffness, strength and composite action in the interface of encased compo site beams. The test and results of the FEM analysis showed that the difference in the ultimate moment capacity of the composite beams with and without studs is under 10%. The reason is that the effect of chemical adhesion, interface interlock, and friction in the interface on the composite action is so high that the encased beams have a moment capacity above some defined magnitude. Also, the increment of moment capacity up to plastic moment is not large and the increase of linearly proportioned.