• 제목/요약/키워드: slip capacity

검색결과 206건 처리시간 0.024초

Mechanical behavior of stud shear connectors embedded in HFRC

  • He, Yu-Liang;Wu, Xu-Dong;Xiang, Yi-Qiang;Wang, Yu-Hang;Liu, Li-Si;He, Zhi-Hai
    • Steel and Composite Structures
    • /
    • 제24권2호
    • /
    • pp.177-189
    • /
    • 2017
  • Hybrid-fiber reinforced concrete (HFRC) may provide much higher tensile and flexural strengths, tensile ductility, and flexural toughness than normal concrete (NC). HFRC slab has outstanding advantages for use as a composite bridge potential deck slab owing to higher tensile strength, ductility and crack resistance. However, there is little information on shear connector associated with HFRC slabs. To investigate the mechanical behavior of the stud shear connectors embedded in HFRC slab, 14 push-out tests (five batches) in HFRC and NC were conducted. It was found that the stud shear connector embedded in HFRC had a better ductility, higher stiffness and a slightly larger shear bearing capacity than those in NC. The experimentally obtained ultimate resistances of the stud shear connectors were also compared against the equations provided by GB50017 2003, ACI 318-112011, AISC 2011, AASHTO LRFD 2010, PCI 2004, and EN 1994-1-1 (2004), and an empirical equation to predict the ultimate shear connector resistance considering the effect of the HFRC slabs was proposed and validated by the experimental data. Curve fitting was performed to find fitting parameters for all tested specimens and idealized load-slip models were obtained for the specimens with HFRC slabs.

데크플레이트 단면형상에 따른 합성슬래브의 합성능력에 관한 연구 (Study on the Composite Capacity of Composite Slabs by Deckplate Section Shapes)

  • 주기수;박성무
    • 한국강구조학회 논문집
    • /
    • 제12권6호
    • /
    • pp.671-680
    • /
    • 2000
  • 이 논문은 합성슬래브의 구조적 거동에 관한 것으로, 개방형 형상인 사다리꼴 데크플레이트와 폐쇄형인 역삼각형 상단플랜지 데크플레이트를 사용한 합성슬래브의 실험에 의한 것이다. 그 결과 합성슬래브의 합성거동을 위해서는 데크플레이트의 형상적인 요소가 매우 중요한 변수로 나타났다. 즉 폐쇄형 형상인 역삼각형 데크플레이트가 사다리꼴 형상보다 전단슬립과 처짐에 더 효과적으로 나타났다. 그러므로 합성데크슬래브 용도로 사용되는 데크플레이트의 개발과 사용에 있어 형상적인 요소가 매우 중요하게 취급되어야 하며, 이에 대한 이론적인 평가도 이루어 졌다.

  • PDF

FRP로 보강된 RC보의 휨거동 예측을 위한 해석모델 (Analysis Model for Predicting the Flexural Behavior of RC Beam Strengthened with FRP)

  • 홍기남;이봉노;한상훈
    • 한국안전학회지
    • /
    • 제26권2호
    • /
    • pp.62-69
    • /
    • 2011
  • This paper presents a new simple two-dimensional frame finite element able to accurately estimate the load-carrying capacity of reinforced concrete beams flexurally strengthened externally bonded fiber reinforced polymer (FRP) strips and plates. The proposed analysis model considers distributed plasticity with layer-discretization of the cross-sections and the bond-slip behavior of epoxy layer. The proposed model is used to predict the load-carrying capacity and the applied load-midspan deflection response of RC beams subjected to bending loading. Numerical simulations and experimental measurements are compared based on numerous tests available in the literature and published by different authors. The numerically simulated response agree remarkably well with the corresponding experimental results. Thus, the proposed model is suitable for efficient and accurate modeling and analysis of flexural strengthening of RC beams with externally bonded FRP sheets/plates and for practical use in design-oriented parametric studies.

Finite element micro-modelling of RC frames with variant configurations of infill masonry

  • Mohammad, Aslam F.;Khalid, Fatima;Khan, Rashid A.
    • Structural Engineering and Mechanics
    • /
    • 제81권4호
    • /
    • pp.395-409
    • /
    • 2022
  • The presence of infill generally neglected in design despite the fact that infill contribution significantly increase the lateral stiffness and strength of the reinforced concrete frame structure. Several experimental studies and computational models have been proposed to capture the rational response of infill-frame interaction at global level. However, limited studies are available on explicit finite element modelling to study the local behavior due to high computation and convergence issues in numerical modelling. In the current study, the computational modelling of RC frames is done with various configurations of infill masonry in terms of types of blocks, lateral loading and reinforcement detailing employed with material nonlinearities, interface contact issues and bond-slip phenomenon particularly near the beam-column joints. To this end, extensive computational modelling of five variant characteristics test specimens extracted from the detailed experimental program available in literature and process through nonlinear static analysis in FEM code, ATENA generally used to capture the nonlinear response of reinforced concrete structures. Results are presented in terms of damage patterns and capacity curves by employing the finest possible detail provided in the experimental program. Comparative analysis shows that good correlation amongst the experimental and numerical simulated results both in terms of capacity and crack patterns.

대직경 스터드 전단연결재의 정적거동 (Static Behavior of Large Stud Shear Connectors)

  • 이필구;심창수;윤태양
    • 한국강구조학회 논문집
    • /
    • 제15권6호통권67호
    • /
    • pp.611-620
    • /
    • 2003
  • 강합성교량에서 19mm 또는 22mm 직경을 갖는 전단연결재가 일반적으로 사용되고 있다. 강교 상세의 단순화와 향후 바닥판 제거의 용이성 및 프리캐스트 바닥판 전단포켓의 효율적인 배치를 위해서는 대직경 스터드 전단연결재가 필요하다. 현재의 전단연결재 설계범위를 넘어서는 대직경 스터드 전단연결재에 대한 push-out 실험을 통해서 정적거동에 관한 항목들을 검토하고 기존 설계식과의 비교를 수행하였다. 25, 27, 30mm 직경의 스터드에 대한 전단실험을 통해서 탄성영역에서의 전단강성을 평가하고 세 개의 직선으로 구성된 하중-상대변위 곡선을 제안하였다. 파괴시의 극한상대변위를 평가하고 극한강도를 유로코드-4의 설계식과 비교하여 설계의 안전율을 평가하였다. 또한 30mm 스터드의 경우는 용접과 콘크리트 지압능력의 개선이 필요한 것으로 나타났다.

Effect of stud corrosion on stiffness in negative bending moment region of steel-concrete composite beams

  • Yulin Zhan;Wenfeng Huang;Shuoshuo Zhao;Junhu Shao;Dong Shen;Guoqiang Jin
    • Steel and Composite Structures
    • /
    • 제48권1호
    • /
    • pp.59-71
    • /
    • 2023
  • Corrosion of the headed studs shear connectors is an important factor in the reduction of the durability and mechanical properties of the steel-concrete composite structure. In order to study the effect of stud corrosion on the mechanical properties in the negative moment region of steel-concrete composite beams, the corrosion of stud was carried out by accelerating corrosion method with constant current. Static monotonic loading was adopted to evaluate the cracking load, interface slip, mid-span deflection, and ultimate bearing capacity of four composite beams with varying corrosion rates of headed studs. The effect of stud corrosion on the stiffness of the composite beam's hogging moment zone during normal service stage was thoroughly examined. The results indicate that the cracking load decreased by 50% as the corrosion rate of headed studs increase to 10%. Meanwhile, due to the increase of interface slip and mid-span deflection, the bending stiffness dropped significantly with the same load. In comparison to uncorroded specimens, the secant stiffness of specimens with 0.5 times ultimate load was reduced by 25.9%. However, corrosion of shear studs had no obvious effect on ultimate bending capacity. Based on the experimental results and the theory of steel-concrete interface slip, a method was developed to calculate the bending stiffness in the negative bending moment region of composite beams during normal service stage while taking corrosion of headed studs into account. The validity of the calculation method was demonstrated by data analysis.

콘크리트와 이형철근의 계면 부착성능 : 상단철근 및 에폭시도막철근 효과 (A Study on Interfacial Bond Capacity of Deformed Bars to Concrete : Top Bars and Epoxy-Coated Bars)

  • 강석원;홍건호;정일영
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1995년도 가을 학술발표회 논문집
    • /
    • pp.204-209
    • /
    • 1995
  • The influence of the interfacial properties on the bond capacity of reinforcing bars to concrete is studied in this paper. In this study, the deterioration of the interfacial bond capacity when top-cast bars or epoxy-coated bars are used is examined. The effect of such variables on bond capacity in reinforced concrete is studied by experiment which use beam-end specimens. The main objective of this study is that comparing the test results and the requirements in ACI 318-89 code. the verification of the factor in ACI code is also presented in this paper. The results of the test show that "top bar effect" is considerably affected by the slump of fresh concrete, so the influence of slump shoud be taken into account for top bar effect factor in code. Test results also shows that the bond-slip curve of the epoxy-caoted bars is similiar to that of the uncoated and bond strength is reduced about 15% and that coating thickness seems to influence the bond strength deterioration.rioration.

  • PDF

Slip-line법을 이용한 V형 암석 노치의 파괴하중 계산 (Calculation of Failure Load of V-shaped Rock Notch Using Slip-line Method)

  • 이연규
    • 터널과지하공간
    • /
    • 제30권4호
    • /
    • pp.404-416
    • /
    • 2020
  • 2차원 응력조건에서 V형 암석노치의 파괴하중을 계산하는 해석적 절차를 slip-line 소성해석법 기반으로 개발하였다. 노치 주변의 암석이 소성상태에 있을 때 slip-line 중 하나인 α선이 암석 노치 면과 노치 외부 수평면을 연결한다는 사실과 α선을 따라서 변하지 않는 불변량이 존재한다는 이론적 사실이 해석적 절차 개발과정에서 핵심 아이디어로 활용되었다. 암석 노치 외부 수평면의 응력 경계조건을 알고 있으므로 불변량 방정식을 풀면 암석 노치 면에 작용하는 수직응력과 전단응력을 계산하는 것이 가능해진다. 노치 면에 작용하는 응력성분 값을 이용하여 쐐기에 의해 노치에 가해지는 파괴하중을 계산하였다. 개발된 해석적 절차를 적용하여 암석 노치파괴 해석을 수행하였다. 암석 노치의 파괴하중은 노치의 각도 및 노치 면의 마찰이 증가함에 따라 지수함수적 비선형성을 가지고 증가하는 특성이 있음을 해석결과는 보여주었다. 이 연구에서 개발한 해석적 절차는 쐐기형 노치 형성을 통한 암석균열 개시조건 연구, 암반 기초 지지력 계산, 암반사면 및 원형터널의 안전성 해석 등에 응용될 수 있을 것으로 기대된다.

An analytical analysis of the pullout behaviour of reinforcements of MSE structures

  • Ren, Feifan;Wang, Guan;Ye, Bin
    • Geomechanics and Engineering
    • /
    • 제14권3호
    • /
    • pp.233-240
    • /
    • 2018
  • Pullout tests are usually employed to determine the ultimate bearing capacity of reinforced soil, and the load-displacement curve can be obtained easily. This paper presents an analytical solution for predicting the full-range mechanical behavior of a buried planar reinforcement subjected to pullout based on a bi-linear bond-slip model. The full-range behavior consists of three consecutive stages: elastic stage, elastic-plastic stage and debonding stage. For each stage, closed-form solutions for the load-displacement relationship, the interfacial slip distribution, the interfacial shear stress distribution and the axial stress distribution along the planar reinforcement were derived. The ultimate load and the effective bond length were also obtained. Then the analytical model was calibrated and validated against three pullout experimental tests. The predicted load-displacement curves as well as the internal displacement distribution are in closed agreement with test results. Moreover, a parametric study on the effect of anchorage length, reinforcement axial stiffness, interfacial shear stiffness and interfacial shear strength is also presented, providing insights into the pullout behaviour of planar reinforcements of MSE structures.

토오크 변환기의 특성에 대한 연구 (A study on the characteristics of torque transducer)

  • 최만용;임동규;한응교
    • 오토저널
    • /
    • 제4권3호
    • /
    • pp.48-55
    • /
    • 1982
  • In the present the strain gauge type torque transducers consist of solid shaft as sensor, slip ring, brush and bridge circuit as detecting circuit. So in the case of measuring the low-capacity torque, the error caused by technical mistake in mounting stain gauge on the small sensor and especially by contact resistance between slip ring and brush takes place more than the large sensor. Therefore in this study constant voltage in order to have no effect of contact resistance is supplied to the hollow shaft and Schrobron Bridge Circuit. Through the experiment good results were obtained as follows; linearity, hysterisis and zero drift as static characteristics is within 1% F.S respectively. Also when loading, zero drift is about 2% F.S.

  • PDF