• 제목/요약/키워드: slice depth

검색결과 27건 처리시간 0.026초

Ceramic Stereolithography: Additive Manufacturing for 3D Complex Ceramic Structures

  • Bae, Chang-Jun;Ramachandran, Arathi;Chung, Kyeongwoon;Park, Sujin
    • 한국세라믹학회지
    • /
    • 제54권6호
    • /
    • pp.470-477
    • /
    • 2017
  • Ceramic processing to fabricate 3D complex ceramic structures is crucial for structural, energy, environmental, and biomedical applications. A unique process is ceramic stereolithography, which builds ceramic green objects from CAD files from many thin liquid layers of powder in monomer, which are solidified by polymerization with a UV laser, thereby "writing" the design for each slice. This approach directly writes layers in liquid ceramic suspension and allows one to fabricate ceramic parts and products having more accurate, complex geometries and smooth surfaces. In this paper, both UV curable materials and processes are presented. We focus on the basic material principles associated with free radical polymerization and rheological behavior, cure depth and broadening of cured lines, scattering at ceramic interface and their corresponding simulation. The immediate potentials for ceramic AM to change industry fabrication are also highlighted.

GOCAD를 이용한 저류층 속성정보의 3차원 시각화 연구 (3-D Visualization of Reservoir Characteristics through GOCAD)

  • 곽상환;이두성
    • 지구물리와물리탐사
    • /
    • 제4권3호
    • /
    • pp.80-83
    • /
    • 2001
  • 미국 텍사스 북부 분스빌 친연가스전에서 취득한 3차원 탄성파자료로부터 4개의 탄성파 반사면과, 탄성파 event 들의 coherence를 도출하여 38개의 검층 자료와 3차원으로 통합 시각화하였다. 시간면은 반사면을 따라 시간을 취득해서 얻었으며 반사면 상에서의 속도는 탄성파 자료와 해석된 38개 검층 자료로부터 산출하였다. 38개 지점의 속도로부터 속도면을 내삽하고 속도면을 이용하여 시간면에서 깊이면으로 변환하였다. Coherence는 탄성파 자료로부터 semblence 방법을 통하여 도출하였으며 입방체로 만든 후 역시 속도면을 이용하여 깊이면으로 변환하였다. 3차원 통합시각화를 통하여 관찰할 때, coherence의 공간적 분포 양상이 잘 파악되었으며, 시간단면등 종래의 3차원 탄성파 분석법과 비교할 때 3차원 시각화 도면에서 선형의 층서적 양상이 더욱 정확함을 알 수 있었다.

  • PDF

한국산(韓國産) 재배고본(栽培藁本)과 야생고본(野生藁本)에 대한 비교(比較) 연구(硏究) (A Comparative Study of between Cultivar and Wild type of Angelica tenuissima in korea)

  • 한신희;이정훈;길기정
    • 대한본초학회지
    • /
    • 제22권3호
    • /
    • pp.1-7
    • /
    • 2007
  • Objectives : This research was observed by examining the external and internal parts and the quantity of the surface components of the wild type and cultivar of Angelica tenuissima in korea. Methods : The slice of the tested material made by paraffin section technique was colored with Safranine Malachite Green contrast methods, and then observed and photographed by the microscope and examined the quantity of the surface components. Results : 1. The cultivar has comparatively many thick roots while the wild type has many radicles, with its root and stem constituting the major part, and the size of its root is small. 2. In case of ferulic acid, the wild type contains 0.066% of it, while the cultivar, 0.031%, The wild type contains 4.258% of z-ligustilide and the cultivar, 1.956%. Conclusions : It was thought that there might be also some differences in their genetic characteristics, etc. On this, however, further in-depth study is needed.

  • PDF

Implementation of Real-Time Post-Processing for High-Quality Stereo Vision

  • Choi, Seungmin;Jeong, Jae-Chan;Chang, Jiho;Shin, Hochul;Lim, Eul-Gyoon;Cho, Jae Il;Hwang, Daehwan
    • ETRI Journal
    • /
    • 제37권4호
    • /
    • pp.752-765
    • /
    • 2015
  • We propose a novel post-processing algorithm and its very-large-scale integration architecture that simultaneously uses the passive and active stereo vision information to improve the reliability of the three-dimensional disparity in a hybrid stereo vision system. The proposed architecture consists of four steps - left-right consistency checking, semi-2D hole filling, a tiny adaptive variance checking, and a 2D weighted median filter. The experimental results show that the error rate of the proposed algorithm (5.77%) is less than that of a raw disparity (10.12%) for a real-world camera image having a $1,280{\times}720$ resolution and maximum disparity of 256. Moreover, for the famous Middlebury stereo image sets, the proposed algorithm's error rate (8.30%) is also less than that of the raw disparity (13.7%). The proposed architecture is implemented on a single commercial field-programmable gate array using only 13.01% of slice resources, which achieves a rate of 60 fps for $1,280{\times}720$ stereo images with a disparity range of 256.

가톨릭대학교 의과대학 진로지도 교육체제 (Career Path Education System at the College of Medicine, The Catholic University of Korea)

  • 유동미;강화선
    • 의학교육논단
    • /
    • 제26권1호
    • /
    • pp.19-26
    • /
    • 2024
  • This study examines a systematic and effective approach to career guidance in medical education, with a particular focus on the 6-year integrated career guidance education framework implemented at the College of Medicine, The Catholic University of Korea. Based on the "New SLICE" educational development principles, this framework comprehensively addresses the needs of medical students in career planning and development. It is structured into three phases: understanding yourself, exploring options, and choosing a specialty. The first phase, understanding yourself, helps students to recognize their strengths, weaknesses, aptitudes, and potentials, thereby setting the direction for future career choices. This phase includes various psychological tests and Self-Development and Portfolio courses. The second phase, exploring options, enables students to engage in related activities such as research and practical training, providing direct and indirect experiences across various fields. This phase offers courses including Medical Field Experience, Career Guidance through the Learning Community & Advisory Professors, and Student Participation in Professor Research Projects. The final phase, choosing a specialty, involves students making decisions based on in-depth self-assessment and exploration of majors, with a capstone project being a significant component. Maximizing the efficiency of career decision-making requires integration between the basic medical curriculum and postgraduate education. Including the period up to residency entrance in the framework is necessary for effective career guidance education.

전뇌 방사선 치료 시 갑상선 차폐체의 주변선량 차폐효과에 대한 유용성 평가 (Evaluation of usability of the shielding effect for thyroid shield for peripheral dose during whole brain radiation therapy)

  • 양명식;차석용;박주경;이승훈;김양수;이선영
    • 대한방사선치료학회지
    • /
    • 제26권2호
    • /
    • pp.265-272
    • /
    • 2014
  • 목 적 : 전뇌 방사선 치료 시 산란선으로 인하여 영향을 받는 갑상선의 피폭선량을 감소시키기 위해 차폐체를 사용하여 갑상선의 차폐 효과를 평가하고자 한다. 대상 및 방법 : 갑상선의 피폭선량을 측정하기 위해 선형가속기(Clinac iX. VARIAN, USA)를 이용하여 6 MV X선, 300 cGy를 인체모형팬텀에 대향 2문 조사하였다. 갑상선의 입사표면선량을 측정하기 위해 인체모형팬텀의 10번째 슬라이스 표면에 유리선량계 다섯 개를 1.5 cm 간격으로 위치시킨 후 차폐체 미사용, bismuth 차폐체 사용, 0.5 mmPb 차폐체 사용, 자체 제작한 1.0 mmPb 차폐체를 사용하여 각각 5회씩 측정하여 평균값을 산출하였다. 또한, 같은 위치에서 갑상선 심부선량을 측정하기 위해서 인체모형팬텀의 10번째 슬라이스 2.5 cm 깊이에서 유리선량계 다섯 개를 1.5 cm 간격으로 위치시킨 후 차폐체 미사용, bismuth 차폐체 사용, 0.5 mmPb 차폐체 사용, 자체 제작한 1.0 mmPb 차폐체를 사용하여 각각 5회씩 측정하여 평균값을 산출하였다. 결 과 : 갑상선의 입사표면선량은 차폐체 미사용 시 44.89 mGy로 측정되었고, bismuth 차폐체는 36.03 mGy, 0.5 mmPb 차폐체는 31.03 mGy, 자체 제작한 1.0 mmPb 차폐체는 23.21 mGy로 측정되었다. 또한, 갑상선의 심부선량은 차폐체 미사용 시 36.10 mGy로 측정되었고, bismuth 차폐체는 34.52 mGy, 0.5 mmPb 차폐체는 32.28 mGy, 자체 제작한 1.0 mmPb 차폐체는 25.50 mGy로 측정되었다. 결 론 : 전뇌 방사선 치료 시 방사선 조사면 밖의 영역에서 발생하는 이차 산란 및 누출 선량에 의해 영향을 받는 갑상선에 대하여 차폐체를 사용했을 때 갑상선 심부는 약 11~30%, 갑상선 표면은 약 20~48% 정도의 피폭선량 감소 효과가 나타났다. 따라서 전뇌 방사선 치료 시 갑상선 차폐체를 사용함으로써 갑상선을 효과적으로 보호하며 치료를 시행할 수 있을 것으로 사료된다.

얼굴뼈 골절의 진단과 치료에 64채널 3D VCT와 Conventional 3D CT의 비교 (Comparison of 64 Channel 3 Dimensional Volume CT with Conventional 3D CT in the Diagnosis and Treatment of Facial Bone Fractures)

  • 정종명;김종환;홍인표;최치훈
    • Archives of Plastic Surgery
    • /
    • 제34권5호
    • /
    • pp.605-610
    • /
    • 2007
  • Purpose: Facial trauma is increasing along with increasing popularity in sports, and increasing exposure to crimes or traffic accidents. Compared to the 3D CT of 1990s, the latest CT has made significant improvement thus resulting in higher accuracy of diagnosis. The objective of this study is to compare 64 channel 3 dimensional volume CT(3D VCT) with conventional 3D CT in the diagnosis and treatment of facial bone fractures. Methods: 45 patients with facial trauma were examined by 3D VCT from Jan. 2006 to Feb. 2007. 64 channel 3D VCT which consists of 64 detectors produce axial images of 0.625 mm slice and it scans 175 mm per second. These images are transformed into 3 dimensional image using software Rapidia 2.8. The axial image is reconstructed into 3 dimensional image by volume rendering method. The image is also reconstructed into coronal or sagittal image by multiplanar reformatting method. Results: Contrasting to the previous 3D CT which formulates 3D images by taking axial images of 1-2 mm, 64 channel 3D VCT takes 0.625 mm thin axial images to obtain full images without definite step ladder appearance. 64 channel 3D VCT is effective in diagnosis of thin linear bone fracture, depth and degree of fracture deviation. Conclusion: In its expense and speed, 3D VCT is superior to conventional 3D CT. Owing to its ability to reconstruct full images regardless of the direction using 2 times higher resolution power and 4 times higher speed of the previous 3D CT, 3D VCT allows for accurate evaluation of the exact site and deviation of fine fractures.

Classification of Upper Body Somatotypes according to the Age Group : Using 3D-Body Scan Data

  • Na, Hyun-Shin
    • International Journal of Costume and Fashion
    • /
    • 제5권1호
    • /
    • pp.1-13
    • /
    • 2005
  • Two hundreds of female aged 19 years old and up were recruited to evaluate the postural changes and bilateral variation of asymmetry over age. To find out the differences among the age group, subjects were classified into 5 groups, early young age(19-29), late young age(30-39), early middle age(40-49), late middle age(50-59), and old age(60-). 35 body measurements were taken by the 3-D body scanner which allowed us to take measurements which cannot be measured using traditional methods, including the shape of a cross section, slice area surface are, and volume. Bilateral variations were observed as a function of age; Depth of scapular point level, scapular point to center back, and blade angle. Postural change of anterior cervical angle, upper anterior thoracic angle, upper posterior thoracic angle, posterior cervical angle, and center back/center front ratio were also exhibited. In each measurements, subjects were classified into normal, and abnormal group. Percentiles of abnormal in shoulder line angle, blade angle, neck point $\∼$ acromial point $\∼$ scapular point, posterior cervical angle, and upper posterior thoracic angle were increased over age group. The upper body of lateral view was classified into 3 types of posture based on the previous research; straight, erect(leaning back), and stooped(bent forward). The percentiles of subjects who have straight postures were decreased as a function of age, but those of stooped postures were increased. Subjects who have erect postures did not so. The stooped posture group shows the big cervical fossa angle, anterior cervical angle, posterior cervical angle, upper posterior thoracic angle, and the small upper anterior thoracic angle comparing to the straight and erect posture group. These results could be apply for clothing construction reflecting the changes in back, shoulder, neck, and the bilateral asymmetry according to the target age group.

Development of seismic fragility curves for high-speed railway system using earthquake case histories

  • Yang, Seunghoon;Kwak, Dongyoup;Kishida, Tadahiro
    • Geomechanics and Engineering
    • /
    • 제21권2호
    • /
    • pp.179-186
    • /
    • 2020
  • Investigating damage potential of the railway infrastructure requires either large amount of case histories or in-depth numerical analyses, or both for which large amounts of effort and time are necessary to accomplish thoroughly. Rather than performing comprehensive studies for each damage case, in this study we collect and analyze a case history of the high-speed railway system damaged by the 2004 M6.6 Niigata Chuetsu earthquake for the development of the seismic fragility curve. The development processes are: 1) slice the railway system as 200 m segments and assigned damage levels and intensity measures (IMs) to each segment; 2) calculate probability of damage for a given IM; 3) estimate fragility curves using the maximum likelihood estimation regression method. Among IMs considered for fragility curves, spectral acceleration at 3 second period has the most prediction power for the probability of damage occurrence. Also, viaduct-type structure provides less scattered probability data points resulting in the best-fitted fragility curve, but for the tunnel-type structure data are poorly scattered for which fragility curve fitted is not meaningful. For validation purpose fragility curves developed are applied to the 2016 M7.0 Kumamoto earthquake case history by which another high-speed railway system was damaged. The number of actual damaged segments by the 2016 event is 25, and the number of equivalent damaged segments predicted using fragility curve is 22.21. Both numbers are very similar indicating that the developed fragility curve fits well to the Kumamoto region. Comparing with railway fragility curves from HAZUS, we found that HAZUS fragility curves are more conservative.

Push-out bond strength and dentinal tubule penetration of different root canal sealers used with coated core materials

  • Sungur, Derya Deniz;Purali, Nuhan;Cosgun, Erdal;Calt, Semra
    • Restorative Dentistry and Endodontics
    • /
    • 제41권2호
    • /
    • pp.114-120
    • /
    • 2016
  • Objectives: The aim of this study was to compare the push-out bond strength and dentinal tubule penetration of root canal sealers used with coated core materials and conventional gutta-percha. Materials and Methods: A total of 72 single-rooted human mandibular incisors were instrumented with NiTi rotary files with irrigation of 2.5% NaOCl. The smear layer was removed with 17% ethylenediaminetetraacetic acid (EDTA). Specimens were assigned into four groups according to the obturation system: Group 1, EndoRez (Ultradent Product Inc.); Group 2, Activ GP (Brasseler); Group 3, SmartSeal (DFRP Ltd. Villa Farm); Group 4, AH 26 (Dentsply de Trey)/gutta-percha (GP). For push-out bond strength measurement, two horizontal slices were obtained from each specimen (n = 20). To compare dentinal tubule penetration, remaining 32 roots assigned to 4 groups as above were obturated with 0.1% Rhodamine B labeled sealers. One horizontal slice was obtained from the middle third of each specimen (n = 8) and scanned under confocal laser scanning electron microscope. Tubule penetration area, depth, and percentage were measured. Kruskall-Wallis test was used for statistical analysis. Results: EndoRez showed significantly lower push-out bond strength than the others (p < 0.05). No significant difference was found amongst the groups in terms of percentage of sealer penetration. SmartSeal showed the least penetration than the others (p < 0.05). Conclusions: The bond strength and sealer penetration of resin-and glass ionomer-based sealers used with coated core was not superior to resin-based sealer used with conventional GP. Dentinal tubule penetration has limited effect on bond strength. The use of conventional GP with sealer seems to be sufficient in terms of push-out bond strength.