• Title/Summary/Keyword: slave

Search Result 696, Processing Time 0.032 seconds

A Haptic Master-slave Robot System : Experimental Performance Evaluation for Medical Application (의료용 햅틱 마스터-슬레이브 로봇 시스템 : 실험적 성능 평가)

  • Oh, Jong-Seok;Shin, Won-Ki;Nguyen, Phuong-Bac;Uhm, Chang-Ho;Choi, Seung-Bok
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.23 no.1
    • /
    • pp.41-48
    • /
    • 2013
  • In this work, 4-DOF ER haptic master is proposed and integrated with a slave robot for minimally invasive surgery(MIS). Using a controllable ER fluid, the haptic master can generate a repulsive force/torque with the 4-DOF motion. For realization of master-slave robot system, the motion command of the haptic master is realized by slave surgery robot. In order to follow the 4-DOF motion of the haptic master, novel mechanism of slave surgery robot with gimbal joint is devised. Accordingly, the haptic master-slave robot system is established by incorporating the slave robot with the haptic master device in which the desired repulsive force/torque and position are transferred to each other via wireless communications. In order to obtain the desired force/torque and position trajectories, tracking controllers for haptic master and slave robot are designed and implemented, respectively. It has been demonstrated that the desired effective torque tracking control performance is well achieved using the proposed haptic master-slave robot system.

A Haptic Master-Slave Robot System : Experimental Performance Evaluation for Medical Application (의료용 햅틱 마스터-슬레이브 로봇 시스템 : 실험적 성능 평가)

  • Oh, Jong-Seok;Shin, Won-Ki;Nguyen, Phuong-Bac;Uhm, Chang-Ho;Choi, Seung-Bok
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.10a
    • /
    • pp.421-427
    • /
    • 2012
  • In this work, 4 DOF ER haptic master is proposed and integrated with a slave robot for minimally invasive surgery (MIS). Using a controllable ER fluid, the haptic master can generate a repulsive force/torque with the 4-DOF motion. For realization of master-slave robot system, the motion command of the haptic master is realized by slave surgery robot. In order to follow the 4 DOF motion of the haptic master, novel mechanism of slave surgery robot with gimbal joint is devised. Accordingly, the haptic master-slave robot system is established by incorporating the slave robot with the haptic master device in which the desired repulsive force/torque and position are transferred to each other via wireless communications. In order to obtain the desired force/torque and position trajectories, tracking controllers for haptic master and slave robot are designed and implemented, respectively. It has been demonstrated that the desired effective torque tracking control performance is well achieved using the proposed haptic master-slave robot system.

  • PDF

Development of a Master-Slave System for Active Endoscope Using a Multi-DOF Ultrasonic Motor

  • Takemura, Kenjiro;Harada, Dai;Maeno, Takashi
    • Transactions on Control, Automation and Systems Engineering
    • /
    • v.4 no.1
    • /
    • pp.17-22
    • /
    • 2002
  • Endoscopes for industrial and medical fields are expected to have multi degree-of-freedom (DOF) motions. A multi-DOF ultrasonic motor we developed consists of a spherical rotor and a bar-shaped stator, and the rotor rotates around three perpendicular axes using three natural vibration modes of the stator. In this study, a multi-DOF unilateral master-slave system for active endoscope using the multi-DOF ultrasonic motor is developed. The configurations of master and slave arms for active endoscope are similar, so that an operator can easily handle the master-slave system. First, driving characteristics of the multi-DOF ultrasonic motor are measured in order to design the slave arm and its controller. Next, the master arm and the slave arm are designed. Then, the unilateral feedback controller for the master-slave system is developed. Finally, the motion control tests of rotor are conducted. As a result, the possibility of the endoscope is confirmed.

Design and Implementation of a Fast DIO(Digital I/O) System (고속 DIO(Digital I/O) 시스템의 설계와 제작)

  • Lee, Jong-Woon;Cho, Gyu-Sang
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.55 no.5
    • /
    • pp.229-235
    • /
    • 2006
  • High speed PC-based DIO(Digital I/O) system that consists of a master device and slave I/O devices is developed. The PCI interfaced master device controls all of serial communications, reducing the load on the CPU to a minimum. The slave device is connected from the master device and another slave device is connected to the slave device, it can repeated to maximum 64 slave devices. The slave device has 3 types I/O mode, such as 16 bits input-only, 16 bits output-only, and 8bits input-output. The master device has 2 rings which can take 64 slaves each. Therefore, total I/O points covered by the master is 2048 points. The slave features 3 types of input/output function interchangeability by DIP switch settings. Library, application, and device driver software for the DIO system that have a secure and a convenient functionality are developed.

Design of AMBA AX I Slave Unit for Pipelined Arithmetic Unit (파이프라인 구조 연산회로를 위한 AMBA AXI Slave 설계)

  • Choi, Byeong-Yoon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2011.05a
    • /
    • pp.712-713
    • /
    • 2011
  • In this paper, the AMBA AXI slave unit that can verify the pipelined arithmetic unit is proposed and the 2-stage 16-bit pipelined multiplier is introduced as design example. The proposed AXI slave unit consists of input buffer block memory, control registers, pipelined arithmetic unit, control unit, output buffer block memory, and AXI slave interface unit. The main operational procedures are divided into the following steps, such as burst-mode input data loading for the input buffer memory, programming of control registers, arithmetic operations for block data in the input buffer memory, and burst-mode output data unloading from output buffer memory to host processor. Because the proposed AXI slave unit is general structure, it can be efficiently applicable to AMBA AXI and AHB slave unit with pipelined arithmetic unit.

  • PDF

A development of a teleoperation system using an universal master arm (범용 매스터 암을 이용한 원격 조작 시스템의 개발)

  • 차동혁;조형석
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1992.10a
    • /
    • pp.343-347
    • /
    • 1992
  • In this paper, an unilateral teleoperation system using an universal master arm is developed. This system is composed of an universal master arm, a slave arm and a telerobot controller. The universal master arm has a vertically articulated type link structure, while an industrial robot is used as a slave arm. As the shapes of master arm and slave arm are different, the workspace mapping is needed, which maps the workspace of master arm to that of slave arm. Experimental results show that the slave arm of the developed system effectively follows the operator's motion.

  • PDF

Double-Frequency Jitter in Chain Master-Slave Clock Distribution Networks: Comparing Topologies

  • Piqueira Jose Roberto Castilho;Caligares Andrea Zaneti
    • Journal of Communications and Networks
    • /
    • v.8 no.1
    • /
    • pp.8-12
    • /
    • 2006
  • Master-slave (M-S) strategies implemented with chain circuits are the main option in order to distribute clock signals along synchronous networks in several telecommunication and control applications. Here, we study the two types of masterslave chains: Without clock feedback, i.e., one-way master-slave (OWMS) and with clock feedback, i.e., two-way master-slave (TWMS) considering the slave nodes as second-order phase-locked loops (PLL) for several types of loop low-pass filters.

Constrained Structured Sliding Mode Control for Position Tracking-Force Reflection Control of Master-Slave Manipulator (마스터-슬레이브 조작기의 위치추종-힘반영을 위한 제한 구조 슬라이딩모드 제어)

  • Kang, Min-Sig
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.12
    • /
    • pp.48-58
    • /
    • 2010
  • In this study, position tracking and force reflection control of a master-slave manipulator which will be used for handling objects contaminated by radioactivity has been addressed. Since available measurements concerning on dynamic motion of the master-slave manipulator are restricted, a simple constrained control structure was suggested. In the consideration of the uncertain dynamic behaviors of the slave manipulator which is dependent upon mass and shape of work pieces grasped and dynamic properties of the environment contacted, a simple structured sliding mode control was suggested to guarantee robustness with respect to parameter uncertainties and external disturbances. The proposed control was applied to a 1-DOF master-slave link system. The control performances were verified along with some computer simulation results.

A Study of a RealTime OS Based Motor Control System for Laparoscopic Surgery Robot (실시간 운영체제 기반의 복강경 수술 로봇의 모터제어 시스템에 관한 연구)

  • Song, Seung-Joon;Kim, Yong;Choi, Jae-Soon;Bae, Jin-Yong
    • Proceedings of the KIEE Conference
    • /
    • 2006.10d
    • /
    • pp.218-221
    • /
    • 2006
  • This paper reports on a Realtime OS based motor control system for laparoscopic surgery robot which enables telesurgery and overcomes shortcomings with conventional laparoscopic surgery. The system has a conventional master-slave robot configuration and the control system consists of joint controllers, host controllers, and power units. The robot features (1) a compact slave robot with 5 DOF (Degree Of Freedom) expanding the workspace of each tool and increasing the number of tools operating simultaneously, and (2) direct 1:1 correspondence in the joint of master and slave robot that simplifies control algorithm and enhances reliability. Each master, slave and GUI (Graphical User Interface) host has a dedicated RTOS (RealTime OS), RTLinux-Pro (FSMLabs Inc., U.S.A.) Each master and slave controller set pair has a dedicated CAN (Controller Area Network) channel for control and monitoring signal communication. Total 4 pairs of the master/slave manipulators as current are monitored by one host controller for operation monitoring and higher level motion control. The system showed acceptable performance in both position control precision and master-slave motion synchronization and is now under further development for better safety and control fidelity for clinically applicable prototype.

  • PDF

New slave-node constraints and element for adaptive analysis of C0 plates

  • Sze, K.Y.;Wu, D.
    • Structural Engineering and Mechanics
    • /
    • v.39 no.3
    • /
    • pp.339-360
    • /
    • 2011
  • In the h-type adaptive analysis, when an element is refined or subdivided, new nodes are added. Among them are the transition nodes which are the corner nodes of the new elements formed by subdivision and, simultaneously, the mid-side nodes of the adjacent non-subdivided elements. To secure displacement compatibility, the slave-node approach in which the DOFs of a transition node are constrained by those of the adjacent nodes had been used. Alternatively, transition elements which possess the transition nodes as active mid-side/-face nodes can be used. For C0 plate analyses, the conventional slave-node constraints and the previously derived ANS transition elements are implemented. In both implementations, the four-node element is the ANS element. With reference to the predictions of the transition elements, the slave-node approach not only delivers erroneous results but also fails the patch test. In this paper, the patch test failure is resolved by developing a set of new constraints with which the slave-node approach surpasses the transition-element approach. The accuracy of the slave-node approach is further improved by developing a hybrid four-node element in which the assumed moment and shear force modes are in strict equilibrium.