• Title/Summary/Keyword: skin-depth

Search Result 373, Processing Time 0.023 seconds

The Effect of Load Direction and Pile Size on the Pile Bearing Capacity : Model Pile Tests (하중 방향(압축-인발)과 말뚝 직경이 말뚝의 지지력에 미치는 영향에 관한 연구 -실내모형시험-)

  • 이인모;백세환
    • Geotechnical Engineering
    • /
    • v.8 no.3
    • /
    • pp.13-22
    • /
    • 1992
  • Model pile tests using calibration chamber are performed in !his paper in order to clarify the effect of the fundamental differences between the newly developed SPLT(Simple Pile Loading Test)and the conventional pile loading test on the pile bearing capacity. They are : (1) the direction of the applied load to mobilize the skin friction ; and (2) the use of reduced sifted sliding core. The conclusions obtained from the model pile tests are as follows : (1) The skin friction in tension loading is found to be somewhat smaller than that in compression loading. The average ration is 0.73 with the coefficient of variation (COV) of 0.18. (2) The ratio of the tip resistance rosin연 the reduced sized sliding core to that using the whole shoe shows wide scattering ; its average is 0.99 and the COV is 0.28. The aver - age of 0.99 means that there is no considerable difference in the tip resistance whether the reduced sized sliding core or the whole shoe is used, on condition that penetration depth ratio is larger than 4 : if the boundary effect of the chamber test is considered, the resistance of the whole shoe might be even larger.

  • PDF

Fabrication and Electrical Evaluation of Al/Cu Composite Conductor (Al/Cu 복합도체 제조 및 전기적 특성 평가)

  • Sim, Ki-Deok;Cho, Jeon-Wook;Bae, Jun-Han;Jung, Won-Mo;Sin, Deok-Su
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.621-622
    • /
    • 2005
  • Copper is widely used in electric wire, cable, conductor in electric devices. As the demand for electric power is increasing rapidly, electric power devices are getting amazingly bigger and complicated. The using of light-weight conductor can reduce the size and making cost of the electric devices. In high-frequency application, Electric current the current in a conductor tends to shift to the surface of the conductor, resulting in an uneven current distribution in the inner conductor. In the extreme case the current may essentially concentrate in the "skin" of the inner conductor as a surface current. In high frequency application, therefore, inner area of copper conductor may replace with aluminum conductor, which reduces the weight of conductor. This paper describes the manufacture and evaluation of composite conductors made of copper and aluminum.

  • PDF

In Vitro and In Vivo Agreement of Microwave Radio-Thermometer and Needle Probe Thermometer During Therapeutic Ultrasound (초음파 가열 시 In Vitro 및 In Vivo에서 Microwave Radio-Thermometer와 탐침온도계의 일치도)

  • Lee, Su-Young;Cho, Sang-Hyun;Yi, Chung-Hwi;Kim, Jong-Man
    • Physical Therapy Korea
    • /
    • v.10 no.1
    • /
    • pp.15-27
    • /
    • 2003
  • Therapeutic ultrasound is commonly applied for deep heating in physical therapy setting. However, it is difficult to determine the exact application dosage and to confirm the immediate heating effect. Microwave Radio-Thermometer (MRT) can measure the temperature by the electromagnetic energy in the microwave region of the object that emits above absolute zero temperature. MRT was used for early diagnosis of breast cancer since it was not harmful, non-invasive, and non-ionizing to the human body. The purposes of this study were to investigate how accurately 1.1 GHz RTM (RES Ltd. Russia) measures the change of average temperature in the tissue, and to determine the depth of temperature change measurement. Therapeutic ultrasound was applied (continuous wave for 5 minutes, 1 MHz, intensity of 1.5 $W/cm^2$ [in vitro] and 1.0 $W/cm^2$ [in vivo]) in four different conditions: (1) 30 cases of in vitro specimen of pork, (2) 30 cases of in vitro specimen of pork ankle joint, (3) 10 cases of in vivo canine thigh, and (4) 30 cases of in vivo human body. Intraclass Correlation Coeffients (ICC[3,1]) between average needle probe thermometer below surface and MRT temperature was revealed as followed: (1) Before ultrasound application ICCs ranges above .8 in specimen of pork (15 mm underneath the skin) and above .82 in specimen of pork ankle joint (10~30 mm underneath the skin). (2) After ultrasound application ICCs ranges above .7 in both specimens of pork and pork ankle joint. (3) Before ultrasound application ICCs ranges above .8 in canine thigh (20 mm underneath the skin). (4) After ultrasound application ICCs ranges above .82 in canine thigh. The temperature of the human body increased significantly with the mean of $15^{\circ}C$ in muscle tissue and with the mean of $3.5^{\circ}C$ in joint (p<.00). It was revealed that the average depth of temperature measurement of the tissue by MRT was in between 10 and 35 mm, and determined that the proper temperature measurement band was $36.5{\sim}37.0^{\circ}C$.

  • PDF

Real-time Face Tracking Method using Improved CamShift (향상된 캠쉬프트를 사용한 실시간 얼굴추적 방법)

  • Lee, Jun-Hwan;Yoo, Jisang
    • Journal of Broadcast Engineering
    • /
    • v.21 no.6
    • /
    • pp.861-877
    • /
    • 2016
  • This paper first discusses the disadvantages of the existing CamShift Algorithm for real time face tracking, and then proposes a new Camshift Algorithm that performs better than the existing algorithm. The existing CamShift Algorithm shows unstable tracking when tracing similar colors in the background of objects. This drawback of the existing CamShift is resolved by using Kinect’s pixel-by-pixel depth information and the Skin Detection algorithm to extract candidate skin regions based on HSV color space. Additionally, even when the tracking object is not found, or when occlusion occurs, the feature point-based matching algorithm makes it robust to occlusion. By applying the improved CamShift algorithm to face tracking, the proposed real-time face tracking algorithm can be applied to various fields. The results from the experiment prove that the proposed algorithm is superior in tracking performance to that of existing TLD tracking algorithm, and offers faster processing speed. Also, while the proposed algorithm has a slower processing speed than CamShift, it overcomes all the existing shortfalls of the existing CamShift.

Controlled Partial Skin Thickness Burns: Rabbit Ear as a 2nd Degree Burn Wound Model for Studies of Topical Therapy

  • Cho, Lee Ae-Ri;Moon, Hee-Kyung
    • Journal of Pharmaceutical Investigation
    • /
    • v.36 no.5
    • /
    • pp.339-342
    • /
    • 2006
  • This study was designed to prepare an animal model for partial thickness bum wound which can be employed for testing topical therapy. We first evaluated whether rabbit ear and mouse back skin wound model could differentiate the wound healing process in terms of degree of re epithelialization, required days for complete wound closure, presence of scarring. $2^{nd}$ degree wet bum were prepared on mouse back skin and rabbit ear by applying 5 mL hot water($85{\pm}0.1^{\circ}C$) for 7 see followed by 5 mL ice-cold 0.5% acrynol solution for cooling and disinfecting the inflicted area. After removing the dead epidermis layer at 24 hr, tested dressings were applied for specified time and wound progression was investigated. In mouse model, wound contraction was the primary wound closing mechanism, which is quite different from human wound healing process. In rabbit ear model, epidermal regeneration was the major wound healing process rather than wound contraction and the difference in wound healing property among tested dressings could be clearly demonstrated. A rabbit ear model could differentiate the wound progression among open, occluded and epidermal growth factor(EGF) treated wound. Four sites of circular wound(diameter: 1 cm) on the anterior part of rabbit ear could be employed for the comparative wound healing study. For obtaining reproducible bum wound, degree of bum depth and bum sites should be carefully controlled in addition, employing rabbits of same strain and weight. The result suggests that rabbit ear could be employed as a reliable and human-resembled wound model.

The Clinical Outcome of Flap Coverage for the Treatment of Malignant Melanoma (악성 흑색종 치료를 위한 피판술의 임상적 결과)

  • Jeon, Woo-Joo;Kang, Jong-Woo;Kim, Il-Hwan;Son, Gil-Soo;Park, Jong-Woong
    • Archives of Reconstructive Microsurgery
    • /
    • v.19 no.2
    • /
    • pp.81-87
    • /
    • 2010
  • In surgical treatment of the malignant melanoma, radical resection and a sentinel lymph node biopsy are essential procedures to eradicate the tumor and to minimize the risk of local recurrence. For the reconstruction of skin defect after tumor resection, a skin graft has been generally performed procedure. However, if tendon or bone is exposed after tumor resection, simple skin graft is not enough for the coverage of the defect and additional procedure is mandatory. In this study, we reviewed the clinical results of 16 patients, who had been diagnosed with malignant melanoma of the limb and underwent surgical resection and reconstruction of the defect with various methods. The sentinel lymph node dissection was performed in all patients combined with radical excision of the tumor. In 11 cases of positive sentinel lymph nodes, further elective lymph node dissections were performed. The mean tumor invasion depth was 4.54 mm (2~10 mm), and AJCC stage II was most common (9 cases). The pedicled flaps were performed in 10 cases for the reconstruction of defects. All flaps were successfully survived without significant complications until the last follow up. In conclusion, a pedicled flap coverage is very useful reconstruction strategy for the soft tissue defects after radical resection of malignant melanoma.

  • PDF

Experimental Study on the End Bearing Capacity of the Pile in a Group Pile (무리말뚝을 구성하는 개별말뚝의 선단지지력에 대한 실험연구)

  • Na, Yong Soo;Lee, Sang Duk
    • Journal of the Korean Geotechnical Society
    • /
    • v.35 no.6
    • /
    • pp.27-38
    • /
    • 2019
  • Bearing capacity of a pile in homogeneous soil is the sum of end bearing and skin resistance, and the skin resistance is more prominent in sandy soil. Bearing capacity of a pile in pile groups especially in sandy ground should be designed under the consideration of the influence by the adjacent piles. In this study, the end bearing capacity of a pile in pile groups was experimentally investigated. For this purpose, piles were installed in sandy ground in a circular test box, and end bearing - settlement behavior of the pile was measured while the pile was loaded. As the results, end bearing - settlement relation curves of the piles showed a distinct limit value. Limit value of the end bearing was little affected by skin friction and pile diameter, and it became a constant value as pile penetrates deeper. End bearing was not affected by the adjacent piles in a group of piles, when their clearance was larger than the pile diameter.

Design and Evaluation of a Scalding Animal Model by the Boiling Water Method

  • Hua, Cheng;Lyu, Lele;Ryu, Hyun Seok;Park, So Young;Lim, Nam Kyu;Abueva, Celine;Chung, Phil-Sang
    • Medical Lasers
    • /
    • v.9 no.1
    • /
    • pp.51-57
    • /
    • 2020
  • Background and Objectives For experiments on simulated burn, the preparation of an animal model is a very important step. The purpose of the current experiment is to design a simple and controllable method for the preparation of third-degree scald in a mouse model using the boiling water method. Materials and Methods A total of 18 Swiss mice were used. After the anesthetization, the mice were scalded by boiling water (100℃) using a mold with a 1 cm2 circle area on the dorsum at contact times of 3s, 5s, and 8s. After confirming that 8 seconds of scald can cause a third-degree scald, the skin samples were collected at day 2, 4, 6, 8, 10, and 12, and analyzed by histopathological examinations. The wound retraction index (WRI) was also measured. Results Third-degree scald involving full-thickness skin was observed in the 8-second scald group, while a 3-second scald caused a superficial second-degree scald and a 5-second scald caused a deep second-degree scald. After third-degree scald, the burn wound continued to contract until day 14. Conclusion The scalding model of mice can be successfully established by the boiling water method. This method is easy to operate, it has a low cost, and it can control the scald depth by controlling the scald time. This is adequate to study skin thermal injury in the future. The scald model established by this method can last for 14 days.

Verification of Skin Dose in Tomotherapy Using the Developed Phantom for Image Based Radiation Treatment System (영상 기반 치료 장비용 팬톰을 이용한 토모테라피 피부 선량 검증)

  • Park, Ji-Yeon;Chang, Ji-Na;Oh, Seung-Jong;Kang, Dae-Gyu;Jung, Won-Gyun;Lee, Jeong-Woo;Jang, Hong-Suk;Kim, Hoi-Nam;Park, Hae-Jin;Kim, Sung-Hwan;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.20 no.2
    • /
    • pp.88-96
    • /
    • 2009
  • Radiation treatment for skin cancer has recently increased in tomotherapy. It was reported that required dose could be delivered with homogeneous dose distribution to the target without field matching using electron and photon beam. Therapeutic beam of tomotherapy, however, has several different physical characteristic and irradiation of helical beam is involved in the mechanically dynamic factors. Thus verification of skin dose is requisite using independent tools with additional verification method. Modified phantom for dose measurement was developed and skin dose verification was performed using inserted thermoluminescent dosimeters (TLDs) and GafChromic EBT films. As the homogeneous dose was delivered to the region including surface and 6 mm depth, measured dose using films showed about average 2% lower dose than calculated one in treatment planning system. Region indicating about 14% higher and lower absorbed dose was verified on measured dose distribution. Uniformity of dose distribution on films decreased as compared with that of calculated results. Dose variation affected by inhomogeneous material, Teflon, little showed. In regard to the measured dose and its distribution in tomotherapy, verification of skin dose through measurement is required before the radiation treatment for the target located at the curved surface or superficial depth.

  • PDF

The Consideration of Bolus Effects of Games Attached on Lesion area (환부 부착용 거즈의 Bolus Effect에 관할 고찰)

  • Park JuYoung;Ju SangKyu;Park YoungChul;Han YoungYi;Shin EunHyuk;Park YongHwan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.16 no.1
    • /
    • pp.51-56
    • /
    • 2004
  • The aim of this study is to evaluate the effect of skin dose and PDD by using wounds protecting gauzes or Vaselinespread gauzes. And it was studied that the possibility to substitute custom bolus into gauzes. 4MV photon (CL600C, varian, US), Polystyrene Phantom (30(W) X30(L) X 30(H)) with Markus chamber(PTW, US) were used for dose measurement. This study was distinguished natural gauzes and spread over Vaseline gauzes. We gave variety to the gauze thickness at 5, 10 and 15 sheets respectively. For comparison between using bolus and not that, we had used 1.0 cm thickness bolus so that analyzed surface dose and PDD at the same conditions above mentioned. When maximum point was defined as reference point, surface dose was measured as $35\%$ in open beam. When the gauzes were attached to surface as 5, 10 and 15 sheets, surface dose were increased as 69, 80 and $91\%$ respectively according to thickness of gauzes. When spread over Vaseline gauzes were attached to surface as 5, 10 and 15 sheets, surface dose were increased respectively as 98, 100 and $98\%$ according to thickness of gauzes. Also when 0.5 cm bolus and 5 sheets gauzes were composed, surface dose was measured as $98\%$. The gauzes that were attached to skin surface in radiation therapy had been scattering material and contributed increasing surface dose without variation of percentage depth dose. However, if we want to delivery much dose to skin surface then we have to apply many sheets of gauzes to skin surface. Although we get easy that result by bolus or spread over Vaseline gauzes, we have to revise percentage depth dose at calculation. Therefore, if we find pertinent conditions based on measured data that are considered skin dose and patient setup efficiency, to replace custom bolus with gauzes will be helpful to efficient treatment.

  • PDF