• Title/Summary/Keyword: skin-depth

Search Result 374, Processing Time 0.03 seconds

The Size and Structural factors of The Korean Elementary School Girls' Hands (학령기 여아의 손 치수 및 구조요인 분석)

  • Jeon, Eun-Kyung;Suk, Eun-Young;Park, Soon-Jee
    • Korean Journal of Human Ecology
    • /
    • v.13 no.6
    • /
    • pp.1023-1029
    • /
    • 2004
  • In the current study, we measured the hands and other representative body items of 223 elementary school girls using Martin Anthropometer and a digital camera so that we would be able to provide information on both size and shape of hands for design of hand-related products. As time goes on, hands get bigger, yet they get thinner at the same time. The data implies that the frame of hands grows, but the skin fat lessens, which could be a determinant factor in the size system of hand-related products. According to the results of a factor analysis on 26 hand items, 5 factors including hand laterality and linearity, fingertip shape, finger breadth, and hand depth, have been extracted. Pearson's correlation showed that most of hand-related factors were strongly associated with other body items. Finger breadth and hand depth, however, were found less related to other body items. The ANOVA test used in testing the difference of hand factors showed, in most items, a difference by ages, but there was no significant differences in fingertip breadth, the third factor, Interestingly, in hand depth, the fifth factor, lower grade girls' hands were thicker than higher grade girls'. This research suggests that the size system of uniformly increasing the size of all hand parts by age groups should be reconsidered and leaves much for improvement.

  • PDF

A Fast and Accurate Face Tracking Scheme by using Depth Information in Addition to Texture Information

  • Kim, Dong-Wook;Kim, Woo-Youl;Yoo, Jisang;Seo, Young-Ho
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.2
    • /
    • pp.707-720
    • /
    • 2014
  • This paper proposes a face tracking scheme that is a combination of a face detection algorithm and a face tracking algorithm. The proposed face detection algorithm basically uses the Adaboost algorithm, but the amount of search area is dramatically reduced, by using skin color and motion information in the depth map. Also, we propose a face tracking algorithm that uses a template matching method with depth information only. It also includes an early termination scheme, by a spiral search for template matching, which reduces the operation time with small loss in accuracy. It also incorporates an additional simple refinement process to make the loss in accuracy smaller. When the face tracking scheme fails to track the face, it automatically goes back to the face detection scheme, to find a new face to track. The two schemes are experimented with some home-made test sequences, and some in public. The experimental results are compared to show that they outperform the existing methods in accuracy and speed. Also we show some trade-offs between the tracking accuracy and the execution time for broader application.

A Study on High Speed Face Tracking using the GPGPU-based Depth Information (GPGPU 기반의 깊이 정보를 이용한 고속 얼굴 추적에 대한 연구)

  • Kim, Woo-Youl;Seo, Young-Ho;Kim, Dong-Wook
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.5
    • /
    • pp.1119-1128
    • /
    • 2013
  • In this paper, we propose an algorithm to detect and track the human face with a GPU-based high speed. Basically the detection algorithm uses the existing Adaboost algorithm but the search area is dramatically reduced by detecting movement and skin color region. Differently from detection process, tracking algorithm uses only depth information. Basically it uses a template matching method such that it searches a matched block to the template. Also, In order to fast track the face, it was computed in parallel using GPU about the template matching. Experimental results show that the GPU speed when compared with the CPU has been increased to up to 49 times.

The Physical Penumbra of the 6MV X-ray (6MV 방사선의 물리학적 Penumbra)

  • Cho Moon-June;Kang Wee-Saing
    • Radiation Oncology Journal
    • /
    • v.9 no.2
    • /
    • pp.333-336
    • /
    • 1991
  • High energy Photon beam has a sharp beam margin due to a less side scatter and the other things. But there still remains a penumbra where the dose changes rapidly in the region near the edge of a radiation beam, although it is short in width. It is suggested that the width of the penumbra depends on the source size, distance from source to diaphragm, source to skin distance, and depth in tissue. However, it is also supposed that the other factors influence the penumbra width. In this paper, we investigate changes of the physical penumbra widths according to various field sizes and depths, by using the three dimensional dosimetry system. As a result, we found that as field size and depth increase, the physical penumbra width also increases.

  • PDF

Evaluation of Skin Friction on Large Drilled Shaft (대구경 현장타설말뚝의 주면 마찰력 평가)

  • Hong Won-Pyo;Yea Geu-Guwen;Lee Jae-Ho
    • Journal of the Korean Geotechnical Society
    • /
    • v.21 no.1
    • /
    • pp.93-103
    • /
    • 2005
  • Both static pile load test with load transfer measuring system and the pile dynamic load test are performed to estimate the skin friction and behavior characteristics of a large drilled shaft. And the numerical modeling of large drilled shaft is performed by applying the FDM program. Since the magnitude of friction resistance depends on the relative displacement between soil and shaft, load and displacement at the arbitrary depth along the large drilled shaft are estimated to analyze the correlation. According to the measuring results of load transfer, unit skin friction along the large drilled shaft was fully mobilized at gravel layer in the middle of shaft and the frictional resistance transmitted to bedrock was relatively small. Also, even for the same drilled shaft, the results of PDA and static load test are different with each other and the difference is discussed.

Analysis of the Bioheat Equation Considering Tissue Layers with Sinusoidal Temperature Oscillation on the Skin (사인 주기의 온도 변화가 가해지는 피부 조직의 생체열 방정식에 대한 해석)

  • Choi, Woo-Lim;Moon, Sang-Don;Youn, Suk-Bum;Im, Ik-Tae
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.8
    • /
    • pp.757-762
    • /
    • 2011
  • We investigate the transient temperature response in biological tissue whose surface is exposed to alternately varying sinusoidal oscillation. Based on the Pennes bio-heat equation, we apply numerical analysis using a finite element method to find the effects of the physical properties of the skin layers. Three layers of tissue-epidermis, dermis, and subcutaneous-are considered as the solution region. We investigate the effects of different properties of the skin layers on the temperature profile. We also investigate the effects of the perfusion rate for the dermis, which is the most sensitive layer. The results show that the temperature profile of tissue depth has a discontinuous point when different physical properties are used.

Optimum Design of Radial Gate (회전식 수문의 최적 설계)

  • 권영두;권순범;박창규;윤영중
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.14 no.3
    • /
    • pp.267-276
    • /
    • 2001
  • On the basis of structural analysis of the radial gate(that is, Tainter gate), this paper focuses on the optimization of the moment distribution according to the location of the arm of the radial gate. In spite of its importance from economical view point, we could hardly find the study on the optimum design of radial gate. Accordingly, the present study identifies the optimum section modulus for a radial arm along with the optimum position for 2 of 3 radial arms with a convex cylindrical skin plate relative to a given radius of the skin plate curvature, pivot point, water depth, ice pressure, etc. These optimum measurements are then compared with previously constructed radial gates. The results indicate that the optimum section modulus vague for a radial arm was appreciably smaller than the previously constructed examples.

  • PDF

Development of a Pulse Light System for Treating Skin Pigmentation (피부의 색소치료를 위한 펄스 광 시스템의 개발)

  • Jeun, Jong-Baeg;Tack, Han-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.25 no.1
    • /
    • pp.81-87
    • /
    • 2021
  • In this study the skin care system was designed and tested by introducing V-IPL(Variable-Intense Pulse Light) methods that allow various skin treatments. The discharge method, a new method of switching on the flash lamp sequentially according to the lesions, was used. Pulse shape control is implemented in the system using the conventional LC variable method and the switching method control method of the switching element. As a result, the pulse width could be varied up to 1[㎛] by using a microprocessor, and by turning on the flash lamp sequentially along the lesions the depth and width, the pulse shape and pulse shape could be more diverse. We could also make long pulses of up to 1~100[ms] in various pulse width. And the special differences between the existing system and the proposed system in this study are as follow. Existing system is one pulse(pulse width : 1~40ms) and proposed system is three pulse(pulse width : 1~100ms).

Superficial Dosimetry for Helical Tomotherapy (토모테라피를 이용한 표면 치료 계획과 선량 분석)

  • Kim, Song-Yih;You, Sei-Hwan;Song, Tae-Soo;Kim, Yong-Nam;Keum, Ki-Chang;Cho, Jae-Ho;Lee, Chang-Geol;Seong, Jin-Sil
    • Radiation Oncology Journal
    • /
    • v.27 no.2
    • /
    • pp.103-110
    • /
    • 2009
  • Purpose: To investigate the feasibility of helical tomotherapy on a wide curved area of the skin, and its accuracy in calculating the absorbed dose in the superficial region. Materials and Methods: Two types of treatment plans were made with the cylinder-shaped 'cheese phantom'. In the first trial, 2 Gy was prescribed to a 1-cm depth from the surface. For the other trial, 2 Gy was prescribed to a 1-cm depth from the external side of the surface by 5 mm. The inner part of the phantom was completely blocked. To measure the surface dose and the depth dose profile, an EDR2 film was inserted into the phantom, while 6 TLD chips were attached to the surface. Results: The film indicated that the surface dose of the former case was 118.7 cGy and the latter case was 130.9 cGy. The TLD chips indicated that the surface dose was higher than these, but it was due to the finite thickness of the TLD chips. In the former case, 95% of the prescribed dose was obtained at a 2.1 mm depth, while the prescribed does was at 2.2 mm in the latter case. The maximum dose was about 110% of the prescribed dose. As the depth became deeper, the dose decreased rapidly. Accordingly, at a 2-cm depth, the dose was 20 % of the prescribed dose. Conclusion: Helical tomotherapy could be a useful application in the treatment of a wide area of the skin with curvature. However, for depths up to 2 mm, the planning system overestimated the superficial dose. For shallower targets, the use of a compensator such as a bolus is required.

An in-depth interview for use of moxibustion therapy in Korea (국내 뜸 요법 임상 실태 파악을 위한 면접조사)

  • Han, Chang-Hyun;Shin, Mi-Suk;Kang, Kyung-Won;Kang, Byoung-Kab;Park, Sun-Hee;Choi, Sun-Mi
    • Korean Journal of Acupuncture
    • /
    • v.25 no.1
    • /
    • pp.85-97
    • /
    • 2008
  • Objectives : Moxibustion therapy is one of the most popular oriental treatments in Korea. In this study, we operate the in-depth interview for use of moxibustion therapy in Korea. Methods : Survey questions were developed based on consensus of acupuncture professors. The list of the Korean medical doctors with experiences more than 10 years is provided by the Association of the Korean Oriental Medicine. The in-depth interview was conducted in 30 Korean medical doctors who answered in the previous telephone survey that they use moxibustion therapy for more than 30 % of patients everyday. Interview survey with them were conducted by the well-trained interviewers of Korea Institute of Oriental Medicine in medical researcher from 22th May to 28th June 2007. Results : Korean medical doctors prefer to use the moxibustion with moxa stick (83.9%). The most common treatment disease was musculo-skeletal disorder (28.9%), gynecology (14.1%), digestive disorder (28.6%). The most common treatment area was the abdomen (35.3%), back (22.5%), lower extremity (15.8%) and upper extremity (16.9%). Indirect moxibustion’s was as frequent as 73.5% of moxibustion method. The most common instrument for treating was mini-moxa of manufactured goods (39.3%). Most Korean medical doctors (48.8%) took up the position that bring symptom relief following good treatment area. 'High preferences of patients' (32.7%) was one of moxibustion strong points but 'Lots of smell and smoke' (54.7%)' was a weak points. The most common side effects was the 'slight burn' (34.9%), 'skin rash' (22.5%), 'skin pruritus' (23.8%) Conclusions : This survey provides unique insight into the perception of the Korea medical doctor at moxibustion therapy. Future research needs to provide more in-depth insight into doctor views of the experience.

  • PDF