• 제목/요약/키워드: skin temperature difference

검색결과 235건 처리시간 0.028초

인조유방의 감촉에 대한 주관적 평가와 인체 생리적 반응 연구 (A Study Measuring the Subjective Sensation and Objective Physiological Responses of Breast Prostheses)

  • 오희경;오희선;김주용
    • 한국의류학회지
    • /
    • 제44권4호
    • /
    • pp.610-625
    • /
    • 2020
  • This study suggests an alternative breast-prosthesis-making process for female breast cancer patients. From June 2018 to July 2018, we conducted a study using nine females between the ages 40-50 who never had breast cancer. We recorded the reported subjective sensations and objective physiological responses to different types of artificial breast materials: Trulife silicon breast prostheses (TS) and hand-made silk breast prostheses (HS). Considering the materials used in TS and HS individually, we studied the subjective sensation with regards to how each material functioned in a photo (VP), movement (VM) and the visual tactility (VT) sense. The results showed that comparing VP and VT led to more significant differences than those comparing VM and VT. In addition, there was a significant difference in terms of tactile sensation when comparing TS and HS with respect to subjective responses to texture. Subjects reported that HS felt more comfortable and gave a better cooling sensation. However, the measured objective physiological responses indicated that skin temperature was higher with HS than TS when touched. This research contributes to scholarship around alternative and new materials to build breast prostheses for women with breast cancer.

체온 이용이 가능한 나노입자 박막 열전소자의 플랫폼 개발연구 (Design of the Platform for a Nanoparticle thin Film Thermoelectric Device transforming Body Heat into Electricity)

  • 양승건;조경아;최진용;김상식
    • 전기전자학회논문지
    • /
    • 제20권2호
    • /
    • pp.174-176
    • /
    • 2016
  • 본 연구에서는 HgTe 나노입자 박막 수평열전 플랫폼에 via를 형성하여 나노입자 박막 양단의 온도 차이를 극대화하였다. HgTe 나노입자 박막은 p-type의 열전 특성을 보였으며, HgTe 나노입자 박막 수평열전소자에서 제백계수는 $290{\mu}V/K$이였다. 또한 피부 위의 via 열전 플랫폼을 통해서 향후 차세대 웨어러블 전자 소자의 구현 가능성을 확인하였다.

A Study on Thermal Comfort Comparison between Tencel and Polyester Indoor Cothing

  • Chung, Sham-Ho;Yoo, Eun-Ok;Hwang, Soo-Kyung;Lee, Han-Seop
    • International Journal of Costume and Fashion
    • /
    • 제9권1호
    • /
    • pp.34-43
    • /
    • 2009
  • This study compared the thermal comfort of indoor clothing from Tencel material that is getting higher in demand due to being eco-friendly with superior wettability, with that from Polyester material that despite being most widely used for indoor clothing, rapidly discharges body sweat due to low wettability. The experiments were performed in the two manners, objective evaluation under the conditions of an artificial climate chamber and subjective evaluation of wearing the given clothes at home followed by filling in the questionnaire. Subjects were 8 healthy elderly women in their 60's who spend majority of their time at home rather than in social activities, and comparison was made on skin temperature and humidity inside clothing at exercise and relaxation states under early summer environment. Based on these results, wearing Tencel material clothing maintained cooler temperatures under warm environment rather than when wearing Polyester material clothing, thus enabling activities under more comfortable state. Regarding humidity inside clothing, parts with twofold clothing did not show difference between Tencel and Polyester, but the onefold arm showed lower when wearing Tencel. With this results, Tencel is regarded as more comfortable and nicer than Polyester.

기 손 반사요법이 입원환자의 자율신경계 활성도와 스트레스 저항도에 미치는 영향 (Effects of Qi Hand Reflexology on Autonomic Nervous System Activity and Physical Resistance to Stress in Inpatients)

  • 오세영;박옥순;우명이
    • 기본간호학회지
    • /
    • 제17권4호
    • /
    • pp.531-538
    • /
    • 2010
  • Purpose: This study was done to identify the effects of Qi hand reflexology on autonomic nerve activity in patients admitted to hospital. Method: A non-equivalent control group and quasi-experimental research with pre/post test design were used and 59 patients on a medical ward were assigned to either the experimental group (32) or the control group (27). The study variables included vital signs, autonomic nerve activities (ALF (absolute low frequency), AHF (absolute high frequency), nLF (normalized low frequency), nHF (normalized high frequency), SDNN (standard deviation of all normal-normal intervals)) and were evaluated using the QECG-3 system. The experimental group was treated with Qi hand reflexology for 10 minutes per day, for 3days. Results: Skin temperature and systolic blood pressure in the experimental decreased with treatment. ALF, AHF and SDNN for the experimental group increased with regulating proportion (nLF: nHF=6:4) and a significant difference between the groups was observed. Conclusion: The results indicated that application of Qi hand reflexology for patients in the hospital is effective in regulating the autonomic nervous system activation. Implication of finding should be useful for future research.

Effect of Housing on Physiological Responses and Energy Expenditure of Sheep in a Semi-arid Region of India

  • Bhatta, Raghavendra;Swain, N.;Verma, D.L.;Singh, N.P.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제18권8호
    • /
    • pp.1188-1193
    • /
    • 2005
  • An investigation was carried out to study the effect of two housing systems on physiological responses and energy expenditure of sheep in a semi-arid region of India. Two types of housing management were adopted. First was a shed- $6{\times}3\;m^2$ structure with all the four sides of 1.8 m chain link fencing with a central height of 3 m. The roof was covered with asbestos sheets and with mud floorings. Second was an open corral- $6{\times}3\;m^2$ open space with all the four sides covered with 1.8 m chain link fencing. Thirty-four (32 ewes and 2 rams) sheep of native Malpura breed aged about 18 months (body weight 28 kg ewes; 35 kg rams) were grazed together on a 35 ha plot of native range. All the sheep were grazed as a flock from 08.00 to 17.00 h during a yearlong study. The flock was divided into two groups (16 ewes+1 ram) in the evening and housed as per the systems (Shed and Open Corral). Dry and wet temperatures were recorded at 06.00 h and 21.00 h using a wet and dry bulb-thermometer both inside the shed and in the open corral and temperature humidity index (THI) was calculated. There was significant (p<0.05) difference in the THI between shed and open corral in all the seasons, indicating that shed was always warmer compared to open corral. Rectal temperature (RT) of both the groups of sheep was similar during morning as well as evening throughout the seasons. There were significant (p<0.05) differences in the skin temperature (ST) and respiration rate (RR) between the two groups at both the measurements in all the seasons. Highest energy expenditure (EE) was recorded inside the shed at 21.00 h (224 kJ/h) during monsoon and lowest at 6.00 h during winter (119 kJ/h). There was a significant (p<0.05) difference between the EE inside the shed and that in the open corral. It was concluded that housing had significant effects on the physiological responses and EE of sheep. Provision of housing at night was stressful during monsoon (with less rainfall) and summer, whereas it was protecting the sheep from acute cold during winter in a semi-arid region of India.

요척주관 협착증 환자의 요부 교감신경 차단술의 효과 및 조영 양상에 따른 피부 체온의 변화 (The Effects of Lumbar Sympathetic Ganglion Block in the Patients with Spinal Stenosis and the Skin Temperature Changes according to the Contrast Spread Patterns)

  • 홍지희;김진모;김애라;이용철;김세영;권승호;오민주
    • The Korean Journal of Pain
    • /
    • 제22권2호
    • /
    • pp.151-157
    • /
    • 2009
  • Background: We hypothesized that if a fluoroscopic image of the lumbar sympathetic ganglion block (LSGB) showed the spread patterns of contrast at both the L2/3 and L4/5 disc areas, then this would demonstrate a more profound blockade effect because the spread patterns are close to sympathetic ganglia. In addition, we compared the effects of LSGB and transforaminal epidural steroid injection (TFESI) for the patients suffering with spinal stenosis. Methods: Eighty patients were divided into two groups (Group S: the patients treated with TFESI, Group L: the patients treated with LSGB). The patients of group L were classified into three groups (groups A, B and, C) according to their contrast spread pattern. The preblock and postblock temperature difference between the ipsilateral and contralateral great toe ($DT^{pre}$, $DT^{post}$, $^{\circ}C$), and the DTnet were calculated as follows. $DT^{net}$ = $DT^{post}$ - $DT^{pre}$. Results: Both group showed a significant reduction of the visual analogue score (VAS) and the Oswestry disability index (ODI) score. Only the patients of group L showed a significant increase of their walking distance (WD). Group A showed the most significant changes in the $DT^{post}$ ($6.1{\pm}1.2^{\circ}C$, P = 0.021), and the DTnet ($6.0{\pm}1.0^{\circ}C$, p = 0.023), as compared to group C. Conclusions: LSGB showed a similar effect on the VAS, and ODI, and a significant effect, on WD, compared with TFESI. Group A showed a significant sympatholytic effect, as compared to group C.

Phase Change Material (PCM) 소재 적용 소방보호복의 화상발생 억제효과에 관한 연구 (Inhibitory Effect of adding Phase Change Material (PCM) to Fire Fighter Protective Clothing on Burn Injuries)

  • 이준경
    • 한국화재소방학회논문지
    • /
    • 제30권3호
    • /
    • pp.16-22
    • /
    • 2016
  • 소방공무원의 화상방지를 위해 소방보호복의 개발이 이루어지고 있으나, 보호 성능을 높이기 위해서 소재의 두께가 증가하고, 그럼으로 경량화 달성이 어려워지는 단점이 존재한다. 이를 극복하기 위한 여러 가지 방법 중 Phase Change Material(PCM, 상변화 물질)을 적용한 섬유를 소방보호복 안감에 적용하는 연구가 진행되고 있다. 기존 연구의 경우, 고온노출시 PCM 적용 섬유의 온도 특성에 대한 연구가 일부 있었으나, 화상 발생과의 직접적인 연관성을 살펴볼 수가 없다는 큰 단점이 존재한다. 본 연구에서는 짧은 시간 고열유속 상태의 돌발화염조건에 대해 현재 사용되고 있는 소방보호복 안감에 대한 PCM 적용 여부에 따라 2도 화상 발생 억제 효과를 수치계산을 통해 살펴보았다. 피부의 화상 해석을 위해 생체 열전달 방정식(Bio-heat transfer)을 이용하여 지배방정식을 유도하였으며, 유한차분법(Finite Difference Method)을 활용하여 화상에 대한 예측을 수행하는 수치해석 접근법을 사용하였다. 시간에 따른 온도 및 손상함수 결과 분석을 통해 PCM 소재의 열흡수가 열전달을 지연시키는 효과가 큼을 확인할 수 있었고, 그에 의해 화상발생을 방지하는 매우 유효한 방법임을 확인할 수 있었다.

Classification of Three Different Emotion by Physiological Parameters

  • Jang, Eun-Hye;Park, Byoung-Jun;Kim, Sang-Hyeob;Sohn, Jin-Hun
    • 대한인간공학회지
    • /
    • 제31권2호
    • /
    • pp.271-279
    • /
    • 2012
  • Objective: This study classified three different emotional states(boredom, pain, and surprise) using physiological signals. Background: Emotion recognition studies have tried to recognize human emotion by using physiological signals. It is important for emotion recognition to apply on human-computer interaction system for emotion detection. Method: 122 college students participated in this experiment. Three different emotional stimuli were presented to participants and physiological signals, i.e., EDA(Electrodermal Activity), SKT(Skin Temperature), PPG(Photoplethysmogram), and ECG (Electrocardiogram) were measured for 1 minute as baseline and for 1~1.5 minutes during emotional state. The obtained signals were analyzed for 30 seconds from the baseline and the emotional state and 27 features were extracted from these signals. Statistical analysis for emotion classification were done by DFA(discriminant function analysis) (SPSS 15.0) by using the difference values subtracting baseline values from the emotional state. Results: The result showed that physiological responses during emotional states were significantly differed as compared to during baseline. Also, an accuracy rate of emotion classification was 84.7%. Conclusion: Our study have identified that emotions were classified by various physiological signals. However, future study is needed to obtain additional signals from other modalities such as facial expression, face temperature, or voice to improve classification rate and to examine the stability and reliability of this result compare with accuracy of emotion classification using other algorithms. Application: This could help emotion recognition studies lead to better chance to recognize various human emotions by using physiological signals as well as is able to be applied on human-computer interaction system for emotion recognition. Also, it can be useful in developing an emotion theory, or profiling emotion-specific physiological responses as well as establishing the basis for emotion recognition system in human-computer interaction.

갈옷과 흰옷 및 그 의복형태의 차가 착용감에 미치는 영향 (The Effect of Differences between Gal-Ot and Undyed Clothing and clothing Types on Wear Sensation)

  • 박순자;손원교
    • 한국의류학회지
    • /
    • 제23권1호
    • /
    • pp.30-41
    • /
    • 1999
  • This study was conducted to verify the advantages of Gal-Ot. Gal-Ot is defined the clothings dyed with persimmon juice. Firstly the physical properties of fabrics were examined. Secondly the wear tests were conducted. The wear tests were performed in climatic chamber controlled 3$0^{\circ}C$ air temperature 50$\pm$5% R.H and 0.2m/s air movement. Four women subjects participated in this experiment and 4 times experiments were performed per one subject. The expeimental schedule was planned following 4 steps that is sedentary posture during 30 minutes-walking the 5。slope treadmill by 70m/min during 20 minutes-sedentary posture during 20 minutes-standing posture on toward the blowing wind during 10 minutes. The results obtained is as folows : The insulation of fabric was increased with dyeing with persimmon juice. The air permeability of fabric was remarkably increased with dyeing with persimmon juice. The mean skin temperatures of subjects were apt to be higher in wearing Gal-Ot than undyed clothing. The clothing micro temperature of subjects were slightly inclined to become lower in wearing Gal-Ot than undyed clothing, The clothing micro humidity was decreasee when: the subjects were gal-Ot than wore undyed clothing, And then it brought about more comfortable on wear sensation. The differences of physiological reactions were not consistent between clothing types except for sweat rate on the back. This result may be attributed the to complex experimental schdules consisted of four steps and to a little difference between open type and close type. However I consider that the clothing type of Gal-Ot is suitable for open type because Gal-Ot is summer wear for blocking the sultry heat.

  • PDF

인삼 식물체의 부위별 호흡량 (Respiration Rate in Each Organ of Ginseng Plant)

  • 이종철;이종율;박훈
    • 한국작물학회지
    • /
    • 제30권2호
    • /
    • pp.154-157
    • /
    • 1985
  • 본 시험은 6월 14 일에 4년생 인삼 식물체의 각 기관별, 10월 1 일에 6년생을 근상태별로 구분하여 호흡량을 측정하였던 바 그 결과는 다음과 같다. 1. 기관별 호흡량은 유과≒엽>화경>경≒근의 순이었다. 2. 15$^{\circ}C$~3$0^{\circ}C$ 사이에서의 기관별 호흡계수는 유과 2.39, 엽 1.75, 근 1.57, 경 1.17, 화경 1.16이었다. 3. 채굴 당시 대편삼(117$\pm$8.8g)과 소편삼(54$\pm$4.0g)간에 호흡량의 차이는 인정되지 않았다. 4. 근내 수분함량이 감소할수록 호흡량은 저하되었으며 그 정도는 소편삼에서 현저하였다. 5 . 건전삼에 비해 근적변삼에서 근호흡량이 현저히 많았다.

  • PDF