• 제목/요약/키워드: skin temperature

검색결과 1,295건 처리시간 0.029초

더운 환경에서 산업용 각반 착용 시 인체생리반응 (Physiological Responses of Wearing Industrial Gaiters in a Hot Environment)

  • 최정화;박준회
    • 한국의류학회지
    • /
    • 제32권7호
    • /
    • pp.1129-1136
    • /
    • 2008
  • The gaiter is one of the personal protective equipments worn in various industrial sites. This study was performed on humans to investigate the physiological strain of wearing gaiters and to compare control gaiters that are currently on the market and new gaiters that are developed for alleviating heat stress. Experiments were conducted in a climatic chamber of WBGT $30.0\pm0.7^{\circ}C$ under five differed experimental conditions: None, Control A, Control B, New A, New B. The results were as follows. The temperature inside gaiters was significantly lower in both New A and New B than in both Control A and Control B and the difference between news and controls was 1$^{\circ}C$ (p<.01). The humidity inside gaiters in both New A and New B were higher than that in Control A, and lower than that in Control B (p<.01). The outermost surface temperature of the gaiter was the lowest in None and it increased in the following order: New B < New A < Control A < Control B. Mean skin temperature was higher by 0.14$^{\circ}C$ in wearing gaiters than in no gaiters. Skin temperatures in lower body were lower in Control than in New and skin temperature in upper body were higher in Control than in New (p<.01). Local sweat rate, total weight loss and subjective sensations did not show a significant difference according to the gaiters. It was concluded that wearing gaiters affected distribution of skin temperature and local sweat rate.

백서에서 경피적 고주파 자극에 따른 온도 변화 및 조직 변화 (Effect of Transcutaneous High Frequency Wave on the Change of Tissue Temperature and Histology in Sprague-Dawley Rat)

  • 김경아;문창원;송다현;김상준
    • Clinical Pain
    • /
    • 제15권2호
    • /
    • pp.92-96
    • /
    • 2016
  • Objective: High frequency wave has been used in cancer treatment and cosmetic area but not in musculoskeletal pain yet. The purpose of this study is to evaluate temperature distribution according to depth and confirm safety of high frequency wave through animal study. Method: High frequency wave was applied to the posterior limb of 9 Sprague-Dawley rats for 20 minutes (experimental group) and no wave was used in the same number of rats for control group. Tissue temperature was measured from skin surface to 1 cm depth (surface, 1 mm, 5 mm, and 1 cm) for 5 seconds. Results: In the experimental group, temperature was elevated 3.2℃ at skin surface, 2.87℃ at 1 mm, 2.25℃ in 5 mm, and 1.74℃ in 1 cm depth. These were significantly different from those in the control group (p<0.001). There was no bulla or redness in the skin after high frequency wave stimulation and neither change of myocytes nor collagen degeneration was found in the tissue histology. There was no apoptosis in the skin surface and muscle layer in TUNEL assay. Conclusion: High frequency wave elevated tissue temperature from the skin to muscle layer without both histologic change and apoptosis.

건축외부공간에 있어서 인체의 일사열부하(日射熱負荷) 및 열적(熱的) 쾌적성(快適性)에 관한 실험적 연구 (Human Solar Heat Load and Thermal Comfort in an Outdoor Environment)

  • 정창원;윤인
    • 한국산업융합학회 논문집
    • /
    • 제1권2호
    • /
    • pp.65-74
    • /
    • 1998
  • The purpose of this paper is to investigate the mount of relief of human solar heat load and thermal comfort in outdoor environment in summer, Six different types of sites, T garden and its neighboring area in Japan, were selected as the experiment sites. The experiments were conducted from 22 to 29 August, 1994 to find the relationship between climatic conditions and human responses, Climatic conditions, subjects's thermal sensation and skin temperature were measured. Radiant heat exchange on the human body was estimated on the basis of the measured air and surface temperature and solar radiation. Thermal index Operative Temperature and New Effective Temperature was modified with the effect of the radiant heat exchange. Human thermal comfort and skin temperature is affected by the solar radiation and the sky factor in an outdoor environment. The effect of tree shade was verified on thermal comfort, The mount of relief of human solar heat load is relation to the existence of shade a solar radiation and the sky factor. The urban garden is one of the effective design element in an urban environmental planning.

  • PDF

PRESERVATION OF QUALITY AFTER BROWN RICE DRYING

  • Goto, Kiyokazu;Miwa, Yoshihiro
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 1996년도 International Conference on Agricultural Machinery Engineering Proceedings
    • /
    • pp.878-885
    • /
    • 1996
  • The brown rice drying is effective for energy saving and cost reduction. However, deterioration after drying is one problem, because the skin damage occurs during the drying. So, the measures to preserve the quality has been investigated. One of major quality deteriorations is the oxidation of fat which is contained in the bran layer. So, milling should be carried out to remove the fat as soon as possible after brown rice drying. And the low temperature storage is also worth to be examined for prevention of oxidation. The effect of skin damage on the increase of fat oxidation was clarified. For the grain of skin damage, the increased of fatty acid vaule was remarkable after 70 days elapsed from occurrence of skin damage even in $15\;^{\circ}C$ condition. Therefore it is impossible to keep grain as brown rice form after brown rice drying. For the clean rice and excessively milled rice, the quality can be preserved even in high temperature of $30\;^{\circ}C$. Therefore the brown rice drying can b applied practically using the clean rice technique.

  • PDF

Girdle 착용이 인체생리반응과 의복기후에 미치는 영향 (A Study on the Physiological Responses and the Microclimate in Girdle)

  • 김현식;최정화
    • 한국의류학회지
    • /
    • 제11권2호
    • /
    • pp.57-67
    • /
    • 1987
  • The purpose of this study was to confirm the effects of girdle on the physiological responses and the microclimate in summer. The measuring points were rectal temperature, skin temperature, pulse rate and sweat volume as physiological responses and the inside clothing temperature, relative humidity as microclimate when the subjects wore girdle (girdle A; polyurethan+nylon, girdle B; polyurethan+cotton) for the period of rest and exercise in climate chamber. The enviromental conditions were at $25^{\circ}C$ ($65{\pm}5\%$ RH) and $30^{\circ}C$ ($75{\pm}5\%$ RR). The results were as followings. 1. Mean skin temperature increased in girdle during the exercise at $30^{\circ}C$. 2. The pulse rate decreased in girdle during the rest at $25^{\circ}C$. In the case of girdle A, it was remarkably decreased. Rectal temperature increased in girdle A and B during the exercise at $25^{\circ}C$. But the kinds of girdle didn't affect the pulse rate and rectal temperature. 3. The total sweat volume in girdle was larger than in control. 4. The difference between skin temperature and inside clothing temperature of abdomen had a tendency to increase at all experiment condition. 5. The relative humidity of inside ($RH_1$) and outside ($RH_2$) of girdle increased in girdle during the rest at $25^{\circ}C$ and $30^{\circ}C$. And the relative humidity of wearing girdle B was hig-her than girdle A during the rest at $25^{\circ}C$ and $30^{\circ}C$. The $RH_1$ after stepping at $30^{\circ}C$ was the highest in girdle A and the lowest in control. From this point of view, we concluded that physiological responses and the microclimate were affected by wearing girdle. And mean skin temperature and relative humidity of inside clothing were affected by the materials of girdle.

  • PDF

한랭환경하에서 운동발한시 인체의 체온조절반응에 대한 내의소재의 생리학적 의의 (Physiological Effects of Different Underwear Materials Thermoregulatory Response during Exercise with Sweating at Cold Environments)

  • 권오경;김태규;손부헌;박승한
    • 한국의류산업학회지
    • /
    • 제1권1호
    • /
    • pp.43-49
    • /
    • 1999
  • This study conducted 4 different kinds of underwear materials, which were A (Cotton 100%), B (Wool 100%), C (Cotton/Wool, 50/50%) and D (Acrylic/Cotton, 50/50%) and were done in a climate chamber under cold ambient $10{\pm}1^{\circ}C$, $40{\pm}5%RH$ by 6 male subjects who were in good health. Physiological parameters such as rectal and local skin temperature(forehead, forearm, hand, trunk, thigh, leg, foot, back and chest), heart rate, body weight loss, clothing microclimate, blood lactic acid concentration, and wearing sensation were measured. Started with a 15-min rest period, 15-min of exercise 1 (the condition of 4.5 mile/hr walking speed equivalent to with 8.5 Kcal energy consumption on the treadmill) period, 15-min rest period, exercise 2 (after 3minutes warming-up at 3.0. 3.7, 4.5. 5.2. 6.0, 6.7 mile/hr) until exhaustion period, and final 15-min of recovery period were performed. The results were as follows: The lowest mean skin temperature was acrylic/cotton in order of wool > cotton/wool > cotton > acrylic/cotton (F=13. 79. p<0.00l). Most of all skin temperature by parts of body had turned out in sequence of temperature wool > cotton/wool > acrylic/cotton > cotton. Fore arm part showed highest temperature about $32.43^{\circ}C$ on wool and had a tendency approximately $1.8^{\circ}C$ higher than cotton which had the lowest temperature, and had the biggest difference among garments in terms of skin temperature. The back temperature within clothing showed about $2^{\circ}C$ higher than the chest temperature within clothing. but the back humidity within clothing showed about 4~12% higher than the chest humidity within clothing. Body weight loss by each garment was this sequence; cotton > acrylic/cotton > wool > cotton/wool.

  • PDF

Effect of Far-Infrared Finishing on Brassiere Pad

  • Shin Jung-Sook
    • The International Journal of Costume Culture
    • /
    • 제8권2호
    • /
    • pp.124-131
    • /
    • 2005
  • This study focused on the change of skin temperature by the emissivity and emission power of far-infrared for conformant far infrared effect to naked eyes. The study method is to manufacture the bra pad by each concentration on far-infrared materials of illite powder $(K,H_3O)AI_2(Si,Al)_4O_{10}(H_2O,OH)_2)$, liquid alumina ($Al_2O_3$), the extracted liquid from 29 kind of medical plants, then, measured change of skin temperature. Result are as follows. Far-infrared were emitted each $90.2\%,\;90.1\%,\;89.7\%$ from the illite powder, liquid alumina, extracted liquid from medical plants. When the testee weared the bra pad, the temperature of coated bra pad was $0.5^{\circ}C$ higher than the non finished bra pad. Washing fastness on far-infrared finishing was better dope addition method than coating method.

  • PDF

기미론의 연구(I) - 부제 : 체온과 사기의 관계 - (A study on KIMI-Theory (I) - The relationship between 'KI' and changes in body temperature -)

  • 이한구;이미영;이제현
    • 한국한의학연구원논문집
    • /
    • 제1권1호
    • /
    • pp.419-431
    • /
    • 1995
  • The common KIMI-Theory of Oriental medicine has evaluated clinical effects of herbal-drug based on KI, nature of berbs, and tastes. The KI in the theory consists of hotness, warm, cool and coldnes and also the Mi does five tastes such as sour, bitterness, sweet, spicy hotness and saltiness. However the KI does not mean thermal effect only. Thus we tried to determine skin and rectal temperatures at the same time for evaluating the relationship between KI and berbs. Male, adult Sprage-Dawly rat was chosen and berbal extract, 10g/Kg, was given orally once at 9:00 A.M. changes in rectal and skin temperatures were measured at 10, 30, 60, and 90 mins after the drug administratin. The changes in body temperatures are in greate deal of agreement of KI written in Herbology literatures.

  • PDF

비닐하우스용 작업복의 자외선 차단 성능과 착용감 연구 (UV ray protective function and wear sensation of garment for plastichouse worker)

  • 최정화;백윤정
    • 한국농촌생활과학회지
    • /
    • 제6권1호
    • /
    • pp.25-30
    • /
    • 1995
  • This study was designed to obtain the basic data developing the UV ray protective garments for the plastichouse workers. Two subjects were volunteered for 1hr. wear test in plastic house, and the ensembles was composed of one of three kinds blouse (UV blocking blouse, polyester/cotton 47/53 blouse, and polyester blouse), shorts, sleeveless undershirts, pants and socks. The measurements were rectal temperature, skin temperature, microclimate inside clothing, subjective sensation, and the colour difference of UV sensor. The results were as follows: 1. Microclimate especially, temperature inside clothing of polyester blouse was the highest among the garments. And UV-proof polyester blouse showed the lower mean skin temperature and microclimate than others. Showing the highest sweat volume. 2. No significant difference on UV ray blocking function among 3 kinds of garment was shown. 3. We could conform that in spring for the plastic house wぉw s garment low thermal insulating value and wide covering area were more important factors than UV blocking function of fabric.

  • PDF

Wireless health monitoring of stay cable using piezoelectric strain response and smart skin technique

  • Kim, Jeong-Tae;Nguyen, Khac-Duy;Huynh, Thanh-Canh
    • Smart Structures and Systems
    • /
    • 제12권3_4호
    • /
    • pp.381-397
    • /
    • 2013
  • In this paper, wireless health monitoring of stay cables using piezoelectric strain sensors and a smart skin technique is presented. For the cables, tension forces are estimated to examine their health status from vibration features with consideration of temperature effects. The following approaches are implemented to achieve the objective. Firstly, the tension force estimation utilizing the piezoelectric sensor-embedded smart skin is presented. A temperature correlation model to recalculate the tension force at a temperature of interest is designed by correlating the change in cable's dynamic features and temperature variation. Secondly, the wireless health monitoring system for stay cables is described. A piezoelectric strain sensor node and a tension force monitoring software which is embedded in the sensor are designed. Finally, the feasibility of the proposed monitoring technique is evaluated on stay cables of the Hwamyung Grand Bridge in Busan, Korea.