• Title/Summary/Keyword: skin reaction

Search Result 643, Processing Time 0.025 seconds

Anti-inflammatory Effect of Sabaek-san Extract through ECS Control in Atopic Dermatitis (아토피피부염에서 ECS 조절을 통한 사백산추출물의 염증 완화 효과)

  • Ahn, Sang Hyun;Jeong, A Ram;Kim, Ki Bong
    • The Journal of Pediatrics of Korean Medicine
    • /
    • v.36 no.3
    • /
    • pp.87-96
    • /
    • 2022
  • Objective The purpose of this study was to confirm the effect of Sabaek-san extract on skin damage recovery and inflammation relief in atopic dermatitis-induced mice through Endocannabinoid system (ECS) control. Methods In this study, we used 6-week-old NC/Nga mice were divided into 4 group: control group (Ctrl), lipid barrier elimination group (LBEG), palmitoylethanolamide (PEA) treated group after lipid barrier elimination (PEAG), and Sabaek-san extract treatment group after lipid barrier elimination (SBSG). Each group was assigned 10 animals. After drug administration of three weeks duration following lipid barrier elimination, cannabinoid receptor (CB) 1, CB2, CD (Cluster of Differentiation) 68, phosphorylated inhibitor kappa B (p-IκB), inducible nitric oxide synthase (iNOS), Fc ε receptor, substance P and serotonin were observed to confirm the regulation of the ECS, macrophage activity and mast cell activity. Results We found that 8-hydroxydeoxyguanosine (8-OXdG) positive reaction was significantly lower in the SBST group than in LBET and PEAT groups. Both CB1 and CB2 showed higher positive reactions in the SBST group than in the LBET and PEAT. CD68, p-IκB, iNOS, Fc ε receptor, Substance P and serotonin showed lower positive reaction in the SBST compared to the LBET and PEAT. Conclusion It was confirmed that the Sabaek-san extract can reduce the inflammation of atopic dermatitis by restoring the structural damage of the skin lipid barrier through ECS activity.

Basic Research of Non-Invasive Optical Transcutaneous pCo2 Gas Sensor & Analytic Equipment (비침습적 방법에 의한 광학식 Transcutaneous pCo2 가스센서 및 분석장치 개발을 위한 기초연구)

  • Kim, Do-Eok;Lee, Seung-Ha;Cho, Eun-Jong;Kang, Shin-Won
    • Journal of Sensor Science and Technology
    • /
    • v.13 no.4
    • /
    • pp.258-263
    • /
    • 2004
  • In this study, we carried out a basic study for the development of optical transcutaneous $pCO_{2}$ gas sensor and analyzer using non-invasive method. The basic principle of $pCO_{2}$ measurement is adapted Beer lambert's law and embodied the system using NDIR method. This measuring system was composed of a IR lamp, a optical filter, a optical reaction chamber, pyroelectric sensor and a signal process. We measured $EtCO_{2}'s$ concentration in basis step instead of $pCO_{2}$ gas that can collect by inflicting heat in outer skin. We minimize the size of optical reaction chamber which takes up the largest volume, to make the portable sensor. We made optical reaction chamber in Si wafer using MEMS technology and the optical reaction chamber was shortened to 2 mm and we carried out an experiment. When we injected the $EtCO_{2}$ to the inside of the optical reaction chamber, we could confirm change of 4.6 mV. The system response time was within 2 second that is fairly fast.

Fine Structure Effect of PdCo electrocatalyst for Oxygen Reduction Reaction Activity: Based on X-ray Absorption Spectroscopy Studies with Synchrotron Beam

  • Kim, Dae-Suk;Kim, Tae-Jun;Kim, Jun-Hyuk;Zeid, E. F. Abo;Kim, Yong-Tae
    • Journal of Electrochemical Science and Technology
    • /
    • v.1 no.1
    • /
    • pp.31-38
    • /
    • 2010
  • In this study, we have demonstrated the fine structure effect of PdCo electrocatalyst on oxygen reduction reaction activity with different alloy composition and heat-treatment time. In order to identify the intrinsic factors for the electrocatalytic activity, various X-ray analyses were used, including inductively coupled plasma-atomic emission spectrometer, transmission electron microscopy, X-ray diffractometer, and X-ray Absorption Spectroscopy technique. In particular, extended X-ray absorption fine structure was employed to extract the structural parameters required for understanding the atomic distribution and alloying extent, and to identify the corresponding simulated structures by using FEFF8 code and IFEFFIT software. The electrocatalytic activity of PdCo alloy nanoparticles for the oxygen reduction reaction was evaluated by using rotating disk electrode technique and correlated to the change in structural parameters. We have found that Pd-rich surface was formed on the Co core with increasing heating time over 5 hours. Such core shell structure of PdCo/C showed that a superior oxygen reduction reaction activity than pure Pd/C or alloy phase of PdCo/C electrocatalysts, because the adsorption energy of adsorbates was apparently reduced by lowering the dband center of the Pd skin due to a combination of the compressive strain effect and ligand effect.

THE CHANGE OF EXTRACELLUAR ALKALINE PHOSPHATASE EXPRESSION IN HYPERTROPHIC SCAR IN RABBITS (가토의 비후성 반흔에서 세포외 알칼리성 인산효소 발현의 변화)

  • Cho, Young-Ki;Ryu, Sun-Yul
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.21 no.1
    • /
    • pp.23-28
    • /
    • 1999
  • ALP (alkaline phosphatase) is a membrane-bound metalloenzyme that is expressed in osteoblasts, hepatocytes, lung, kidney, endothelial cells, leukocytes and other cells. Normal soft tissue and skin show little tissue nonspecific ALP (TN-AP), However, scar tissue contains high levels of TN-AP activity, and in fact, TN-AP is expressed intensely in regenerating connective tissue after the wounding. The purpose of this study was to evaluate the change of ALP expression in hypertrophic scar model in rabbits and the effect of triamcinonolone on ALP expression. Adult male New Zealand white rabbits, weighing about 2.5 kg, were used. After full-thickeness wounding over the ventral surface of each ear, either saline (control ear) or triamcinolone (contralateral ear) was injected on day 16. Rabbits were sacrificed on day 3, 7, 15, 17, 19, 23, and the specimens were retrieved en bloc. Histologic and immunohistochemical examinations of tissue samples were done. The results obtained were as follows: On day 3, ALP reaction was observed on fibroblasts and inflammatory cells in wound margin. On day 7, ALP reaction was more intense than day p in capillaries, inflammtory cells, and fibroblasts behind newly formed epithelium. On day 15, ALP reaction was lessened in both groups and appeared mainly in subepidermal capillary network, Since day 17, ALP reaction was lessened in both groups and weaker in triamcinolone-injected group than in saline-injected group. These results suggest that ALP reaction isn't increased in triamcinolone-injected scar and triamcinolone reduces scar not by increasing TN-AP expression but other mechanism.

  • PDF

Development of Gel Sheet Mask Based on Physical Properties Study of Tamarindus indica Seed Gum, Ethanol, Polyols, and Acid/Base Reaction (타마린드씨검과 에탄올, 폴리올 및 산·염기 반응의 물성 연구를 바탕으로 한 겔 시트 마스크의 개발)

  • Yeo, Hye Lim;Lee, Hyo Jin;Kang, Hae-Ran;Jung, So Young;Lee, So Min;Kim, Hyung Mook;Kwak, Byeong-Mun;Lee, Mi-Gi;Bin, Bum-Ho
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.47 no.4
    • /
    • pp.305-316
    • /
    • 2021
  • This study relates to the development of a new gel sheet mask that finally does not require support based on the reactivity and acid/base reaction experiments of Tamarindus indica seed gum (TG), ethanol, and polyols. When TG and a specific alcohol was mixed at a certain mixing ratio, a transparent gel is formed by reaction with each component, and thus a gel sheet mask without support might be obtained using the mixture. In order to maximize skin tone improvement, a carbonation system of acid and base reactions was introduced, and skin brightness and moisturizing power were evaluated using a spectrophotometer and a moisture measuring device. Through this study, it is expected that the gelation reaction by hydrogen bonding of TG, ethanol, and polyols can be developed into various types, and the gel sheet mask formulation introduced in this study is expected to help develop new products in the future.

The Effect of Percutaneous Multiple Puncture BCG Vaccination on PPD 1TU, 2TU and 5TU Tuberculin Skin Test (경피용 BCG 백신의 PPD 1TU, 2TU 및 5TU 결핵 피부반응 검사에 대한 영향)

  • Kim, Bo Sun;Hwang, Min Ho;Kim, Chang Hwi;Park, Jae Ok;Shin, Sang Man
    • Pediatric Infection and Vaccine
    • /
    • v.8 no.2
    • /
    • pp.175-180
    • /
    • 2001
  • Purpose : Recently in Korea since 1998, 2TU has been used instead of 5TU, which caused a confusion in interpreting tuberculin skin tests. We compared the tuberculin skin reaction to PPD(purified protein derivatives) 1TU, 2TU and 5TU. Methods : We studied tuberculin skin reaction to PPD 1TU, 2TU and 5TU on 92 infants who were vaccinated with percutaneous multiple puncture BCG vaccine(Tokyo 172 strain, Japan BCG Laboratory Co.) in neonatal period. Diameters of indurations were measured in millimeters 48~72 hours after the intradermal injection of PPD 1TU, 2TU and 5TU. Results : Among 92 infants(male : 56, female : 36), 1TU was used on 31 infants, 2TU on 31 infants and 5TU on 30 infants for tuberculin skin test. The mean diameter of induration for PPD 1TU, 2TU and 5TU were $5.7{\pm}4.2mm$, $7.1{\pm}3.7mm$, and $9.2{\pm}4.2mm$, respectively. There was no statistical difference in mean diameter of induration between 1TU and 2TU. However, when tested with 5TU, the diameter of induration was significantly larger than those of PPD 1TU and 2TU(P<0.05). Six subjects(19.4%) tested with 1TU, 9 subjects(29%) tested with 2TU and 16 subjects(53.3%) tested with 5TU had diameter of 10 mm or more. There was no statistical difference between 1TU and 2TU but for 5TU, number of subjects with diameter of 10 mm or more was significantly higher than PPD 1TU and 2TU(P<0.05). Number of subjects with induration diameter of 5 mm or more for 1TU, 2TU and 5TU was 19(61.3%), 22(71.0%) and 26(86.7%), respectively. However, there was no statistical difference. Conclusion : A new standard criteria for interpreting the tuberculin skin test with PPD 2TU should be established for clinical diagnosis of tuberculosis.

  • PDF

Safety Evaluation of Water-soluble Chromium in Makeup Products (메이크업 화장품에서 수용성 크롬의 안전성 평가)

  • Jeong Hye-Jin;Joo Kyung-Mi;Kim Young-So;Park Jeong-Eun;Park Jin-Hee
    • Toxicological Research
    • /
    • v.21 no.1
    • /
    • pp.15-21
    • /
    • 2005
  • There is now a growing concern about the possible toxicity of heavy metals in cosmetics. Heavy metals can be used as cosmetic ingredients or may be present as low level impurities in some of the raw materials. Chromium derivatives are used as pigments in cosmetics. Chromium is essential and toxic trace elements. Chromium may cause skin allergy. However, the regulations related to cosmetic products give no limit values for Chromium. Hexavalent chromium is significantly more toxic than trivalent chromium. Hexavalent chromium may present a carcinogenic risk at high concentrations. Therefore, it is important to consider oxidation state of chromium when analyze chromium. The purpose of this study is to determine the concentrations of water-soluble trivalent and hexavalent chromium in samples of makeup products, and to assess the safety of cosmetics on the basis of animal sensitization tests using guinea pig. The present study of chromium in 48 makeup products of 12 manufacturers provides a basis for assessing safety of makeup products. Water-soluble hexavalent chromium was not detected in any product. Water-soluble trivalent chromium was detected in only 9 eye shadows out of 48 makeup products, and could not be quantified 3 out of 9 eye shadows. The highest level of water-soluble trivalent chromium was about 10 mg/kg in spite of 90,000 mg/kg of total chromium. The results of animal sensitization tests show that 200 mg/kg of trivalent chromium and 5 mg/kg of hexavalent chromium have no harmful effect. No cross-reaction among these metals was found. Accordingly, the concentrations of water-soluble chromium in makeup products seemed to be safe. The overall results indicate that chromium in cosmetics probably have no significant toxicological effects. However, It is necessary to set guidelines on the maximum permissible concentration of water-soluble chromium in cosmetics.

Effects of Red Deer Antlers on Cutaneous Wound Healing in Full-thickness Rat Models

  • Gu, LiJuan;Mo, EunKyoung;Yang, ZhiHong;Fang, ZheMing;Sun, BaiShen;Wang, ChunYan;Zhu, XueMei;Bao, JianFeng;Sung, ChangKeun
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.21 no.2
    • /
    • pp.277-290
    • /
    • 2008
  • The process of wound repair involves an ordered sequence of events such as overlapping biochemical and cellular events that, in the best of circumstances, result in the restoration of both the structural and functional integrity of the damaged tissue. An important event during wound healing is the contraction of newly formed connective tissues by fibroblasts. The polypeptide growth factors, like transforming growth factor-${\beta}$(TGF-${\beta}$, insulin-like growth factor I (IGF- I) and epidermal growth factor (EGF), play very important mediator roles in the process of wound contraction. Deer antlers, as models of mammalian regeneration, are cranial appendages that develop after birth as extensions of a permanent protuberance (pedicle) on the frontal bone. Antlers contain various growth factors which stimulate dermal fibroblast growth. They are involved in digestion and respiration and are necessary for normal wound healing and skin health. In order to investigate and evaluate the effects of red deer antlers on skin wound site, the speed of full-thickness skin wound healing and the expression of IGF-I, TGF-${\beta}$ and EGF in skin wounds, three groups of skin full-thickness rat models with a high concentration of antler ointment, a low concentration of antler ointment and without antler ointment were compared. At post-injury days 0, 2, 4, 8, 16, 20, 32, 40 and 60, the skin wound area was measured, the expressions of IGF-I, TGF- ${\beta}$ and EGF mRNA were detected by reverse transcriptase polymerase chain reaction (RT-PCR) and collagen formation by sirius red dye and the localization of IGF-I, TGF-${\beta}$ and EGF peptides were inspected by histological immunohistochemical techniques. Wound healing was significantly more rapid in antler treated skins. In addition, the wound treated with a high concentration antler ointment, a low concentration antler ointment, and the control closed completely at post-injury day 40, day 44 and day 60, respectively. Via RT-PCR, the expressions of IGF-I (day 8 and day 16), TGF-${\beta}$(day 8, day 16 and day 20) and EGF (day 4, day 8, day 16, and day 32) were obviously up-regulated in high concentration antler-treated skins compared to control skins. Similar results could be seen in the histological detection of collagen dye and immunohistochemical methods using the corresponding polyclone antibodies of IGF-I, TGF-${\beta}$ and EGF. These results illustrate that antlers stimulate and accelerate the repair of cutaneous wounds.

Characterizations of Water-dispersed Biocellulose Nanofibers on the Skin Surface (피부 표면에서의 수분산 바이오셀룰로오스 미세섬유의 특성에 대한 연구)

  • Jun, Seung-Hyun;Kim, Seo Yeon;Park, Sun Gyoo;Lee, Cheon Koo;Lee, Seol-Hoon;Kang, Nae-Gyu
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.44 no.1
    • /
    • pp.89-94
    • /
    • 2018
  • In this study, water-dispersed biocellulose nanofibers (TC) were prepared via an oxidation reaction using 2,2,6,6-tetramethyl-1-piperidine-N-oxy radical (TEMPO) as a catalyst. The TC retained their unique structure in water as well as in emulsion. TC adhered to the skin surface while maintaining nanofibrous structures, providing inherent functions of biocellulose, such as high tensile strength and high water-holding capacity. When gelatin gels as model skin were coated with TC, the hardness representing the elasticity was increased by 20% compared to untreated gelatin gel because TC could tightly hold the gelatin structure. When porcine skin was treated with TC and TC-contained O/W emulsion, the initial water contact angles of TC were lower than other materials, and dramatically decreased over time as water penetrated the fibrous structure of the TC film. Characterization of TC on the skin surface offered insight into the function of nanofibers on the skin, which is important for their applications with respect to fiber-cosmetics.

Preparation and Properties of Phytosphingosine Ascorbate with Retaining Skin Development Effects (피부 활성을 갖는 Phytosphingosine Ascorbate의 합성)

  • Min, Seok-Kee;Jin, Yong-Hoon;Park, Woo-Jung;Eom, Sang-Yong;Kim, Jong-Heon
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.30 no.2
    • /
    • pp.167-172
    • /
    • 2004
  • In the human skin, vitamin C (L -ascorbic acid) that is well known as the activated materials has effects that is skin anti-aging and wrinkle repair by giving impetus to collagen biosynthesis and anti-oxidation, and that is the sun screen, a wound recovering, inhibition melanogenesis and so on. In spite of its effects, vitamin C has the defects of the skin stimulation and easily oxidized instability by water, air, heat and light. For solving their matters, many investigation is advanced and its results are synthesized the various vitamin C derivatives. And yet they have not solved the unstable property of vitamin C and were still insufficient for the comparing with the effect of the pure vitamin C itself. In this study, in order to prepare vitamin C derivative of being improved the stability and to apply vitamin C effect in the skin, we prepared new vitamin C derivative, phytosphingosine ascorbate, by using phytosphingosine, one of sphingolipids, which have a distinguished skin affinity. Phytosphingosine ascorbate can be prepared as the ionic bond between amine group (-NH$_2$) of phytosphingosine and hydroxy group (-OH) of vitamin C by way of the relatively simple reaction. So the structure and properties of the synthesized phytosphingosine ascorbate was confirmed the use of elemental analysis (C 58.3 : H 9.3 : N 2.8 : O 29.5), MALDI TOF-MS (Mw=492.58), Ultraviolet spectra (268.5nm), lH NMR, FT-IR spectra, thermal analysis (m.p=l54$^{\circ}C$), HPLC and so on. And we could confirm the anti-bacterial and anti-oxidation effects. Based on these results, we could confirm to prepare a new material that was expected of both effects of vitamin C and phytosphingosine and that is improved properties of vitamin C.