• Title/Summary/Keyword: skin health

Search Result 1,748, Processing Time 0.033 seconds

The Study on Clinical Conditions and Skin Dose of Upper-Gastrointestinal X-ray Fluoroscopy (위장 X선 투시검사에 따른 실태 및 선량에 관한 연구)

  • Kim, Sung-Chul;Ahn, Sung-Min;Jang, Sang-Sup
    • Journal of radiological science and technology
    • /
    • v.30 no.1
    • /
    • pp.7-12
    • /
    • 2007
  • This study examined present conditions of upper-gastrointestinal X-ray fluoroscopy and patient skin dose. The authors elected 21 equipments to check the X-ray equipment and exposure factor of fluoroscopy & spot exposure in university hospitals, hospitals, and clinics where perform upper-gastrointestinal X-ray fluoroscopy more than five times every day in Incheon areas. The amount of patient's skin dose during upper-gastrointestinal X-ray fluoroscopy was measured by ionization chamber.

  • PDF

Analysis of Optimal and Pleasant Driving Condition using Physiological Signals (생리신호 측정을 통한 심리적 적정 운전상태 분석)

  • 김정룡;황민철;박지수;윤상영
    • Science of Emotion and Sensibility
    • /
    • v.7 no.3
    • /
    • pp.27-35
    • /
    • 2004
  • This study has investigated a psychological status of optimal and pleasant driving condition by measuring various physiological signals using SCR(skin conductance response), PPG(peripheral plethysmograph), SKT(skin temperature) and HR(heart rate). The physiological response was measured during various simulated driving conditions. We developed a hardware and algorithm to measure and analyze the physiological response. The physiological signals has reflected the level of driver's tension or relaxation as well as the heart rate. The emotional responses of drivers were also measured and analyzed in this experiment. The result of the study can be used to design a system to enhance the driver's emotional satisfaction as well as to monitor the driver's safety and health condition.

  • PDF

The Problems in the Measurement of DC Potential on Meridian Skin Area (경락노선상 직류 전위 측정에서의 문제점)

  • Heo, Ik-Beom;Lee, Woo-Cheol;Lee, Yoo-Jeong;Yin, Chang-Shik
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.9 no.1
    • /
    • pp.131-135
    • /
    • 2005
  • Background and purpose: The measurement of direct current (DC) potential on skin area of meridian has recently been adopted to explore the electrophysiological characteristics of meridian system, But there exists two problems to be explained; the entity of the DC potential to be measured and the characteristics of electrode gel interface of measurement system, It is not clear whether the DC potential reflect, at least hypothetically, the entity of meridian, and if there exist any unstable factor in the DC potential measurement system. Methods: In this study, we designed an electronic circuit model of skin and applied known DC potential sources $({\pm}10.75mV,\;0mV)$ to the electrode interface of the skin model. Results: The result showed that the measured DC potential changed according to the time, and the same phenomenon was observed when the electrode gel was replaced with an electric condenser. It is suggested that the measurement of DC potential on electrode gel interface is very difficult and produces unstable values due to the capacity effect of electrode gel. Conclusion: Further studies on the DC potential evaluation in the context of meridian study should consider and bypass this problem.

  • PDF

The Effect of the Polygonum tinctoria Niram on Atopic Dermatitis in DNCB-Induced Hairless Mice (쪽 니람의 DNCB 유발 생쥐의 아토피 피부염에 미치는 효과)

  • Choo, Han-Na;Park, Eun-Hye;Jeong, Jong-Kil;Paek, Yun-Woong;Kim, Jeong-Sang
    • Herbal Formula Science
    • /
    • v.22 no.1
    • /
    • pp.141-150
    • /
    • 2014
  • Objectives : The purpose of this study was to investigate the effects of Polygonum tinctoria Niram(PTN) on atopic dermatitis(AD) in hairless mice induced by 2,4-dinitrochlorobenzene(DNCB). Method : They were divided into four group, Nor, Con, 1X and 5X, for evaluating the change of appearance of skin surface, skin hydration, thickness of epidermis and mast cell numbers during 30 days. Results : PTN suppressed symptoms of AD in appearance of skin and increased skin hydration for 1X and 5X. In histopathological examination, 1X and 5X significantly reduced the thickness of epidermis and number of mast cell in dermis. These results suggested that the PTN improved the AD-like symptoms of hairless Mice.

Evaluation of Irritating Potential of Newly Developed Toothpaste in the Hamster Oral Mucous Membrane

  • Kim, Bae-Hwan;Kim, Jin-Woo;Chang, Ih-Seop;Sim, Young-Chul;Lee, Yong-Soon
    • Toxicological Research
    • /
    • v.17 no.3
    • /
    • pp.167-171
    • /
    • 2001
  • Oral mucous membrane test using Syrian hamsters was performed to evaluate the reliability as a model system for the assessment of the potentially irritating substances intended for the mucous membranes, and to determine the irritating potential of a new emulsion-type formulated toothpaste. After test substances were implanted into the cheek pouches of hamsters with diluents (20 mg/kg) under pento-barbital sodium anesthesia, we made the comparison in irritation between emulsion-type and dispersion-type of triclosan (TCS) formulations in the range of 0.2% to 0.3%. The emulsion-type formulations using non-ionic surfactant showed less mucosal lesion than other commercial toothpastes with 0.3% TCS, or dispersion-type ones. However, no significant difference in irritation was detected between 0.2% and 0.3% TCS. We report that this hamster cheek pouch method could be a reliable approach for the evaluation slight difference in the irritating potentials of cosmetics and hygiene products intended for the lips or other mucous membranes, and this method showed that the new emulsion-type formulation significantly lowered the TCS-induced toxicity, compared with other commercial toothpastes.

  • PDF

Effect of a New Developed Physical Restraint to Reduce Skin Injury in Intensive Care Units (중환자실에서 피부손상을 감소시키기 위한 억제대 개발 및 적용효과)

  • Mun, Jung-Sook;Lee, Gyeong-Nam;Lee, Dong-Suk
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.18 no.1
    • /
    • pp.28-36
    • /
    • 2011
  • Purpose: The purpose of this study were to develop a new restraint for the intensive care units (ICU) and to investigate the application effect in comparison with a control group using existing restraints. Method: A non-equivalent control group non-synchronized quasi-experimental research design was used. The participants were 40 (control 20, experimental 20) patients who were recruited by convenience sampling the ICU of a university hospital. To avoid contamination of the experiment, data for the control group were collected prior to the experimental group. Measurement variables were edema and skin damage (redness and abrasion) at the application site, and nurses' perceived convenience in applying restraints. Results: Three days after applying the restraint, amount of edema at the application site was small and incidence of skin damage decreased in the experimental group in comparison with the control group. Also, score for application convenience measured by the nurses was higher in for the newly developed restraint than for existing restraints. Conclusion: Results indicate that the newly developed restraint has lower effects such as edema and skin damage and is more convenient compared with existing restraints, and is therefore recommended for patients in the ICU.

Physiological effects of formulation containing tannase-converted green tea extract on skin care: physical stability, collagenase, elastase, and tyrosinase activities

  • Hong, Yang-Hee;Jung, Eun Young;Noh, Dong Ouk;Suh, Hyung Joo
    • Integrative Medicine Research
    • /
    • v.3 no.1
    • /
    • pp.25-33
    • /
    • 2014
  • Background: Green tea contains numerous polyphenols, which have health-promoting effects. The purpose of this study was to evaluate the effect of tannase-converted green tea extract (TGE) formulation on the physical stability and activities of skin-related enzymes. Methods: Physical stability was evaluated by measuring the pH, precipitation, and colors at $25{\pm}2^{\circ}C$ /ambient humidity and at $40{\pm}2^{\circ}C$ \70%${\pm}$5% relative humidity for 4 months. Activities of collagenase, elastase, and tyrosinase as skin-related enzymes were assessed on TGE formulation. Results: The concentrations of epigallocatechin-3-gallate and epicatechin-3-gallate in green tea extract were greatly decreased to the extent of negligible level when treated with tannase. The formulation containing 5% tannase-converted green tea extract showed relatively stable pH, precipitation, and color features for 16 weeks. When TGE was added to the formulation, there was a significant increase in the inhibition of elastase and tyrosinase activities (p<0.05) compared with the formulation containing 5% normal green tea extract. Conclusion: The TGE could be used in cosmetics as skin antiwrinkling or depigmenting agent.

Imperceptible On-Skin Sensor Devices for Musculoskeletal Monitoring and Rehabilitation (상시 근골격 모니터링과 재활을 위한 온스킨 센서 디바이스 기술)

  • Park, C.W.;Koo, J.B.;Jin, H.;Kim, Y.;Lim, C.;Hong, C.H.;Kim, H.J.
    • Electronics and Telecommunications Trends
    • /
    • v.37 no.2
    • /
    • pp.30-41
    • /
    • 2022
  • As the society is superaging, the number of patients with movement disabilities due to musculoskeletal or nervous system illness is rapidly increasing. To improve public health and reduce medical expenses, it is essential to develop rehabilitation systems that allow patients to resume their daily-life activities. However, the existing musculoskeletal illness diagnosis and rehabilitation method is limited in terms of precision and efficiency because it is based on an empirical diagnosis and prescription without regard for individual characteristics. To overcome these limits, it is critical to design a novel concept of routine rehabilitation therapy device that is capable of inducing musculoskeletal balance by the precise analysis of musculoskeletal usage patterns via the motion and the muscle activity tracking of linked muscles. This study introduces the trend of on-skin sensor device technology for routine musculoskeletal monitoring and therapy. For on-skin rehabilitation systems, skin-adhesive and stretchable motion/posture, electromyography, pressure sensors, small-size and low-power wireless sensor interfaces, and user-friendly rehabilitation contents based on new algorithms are combined.

The role of rapid tissue expansion in separating xipho-omphalopagus conjoined twins in Vietnam

  • Tran, Thiet Son;Pham, Thi Viet Dung;Ta, Thi Hong Thuy;Vu, Duy Kien;Nguyen, Thanh Liem
    • Archives of Plastic Surgery
    • /
    • v.48 no.4
    • /
    • pp.378-383
    • /
    • 2021
  • Conjoined twins are rare, and each set of conjoined twins has a unique conjoined anatomy. It is necessary to perform separation to increase the chance of patient survival. Tissue expansion is an advanced technique for providing sufficient soft tissue and skin for wound closure. We report the successful application of rapid tissue expansion in 10-month-old xipho-omphalopagus conjoined twins in Vietnam. A tissue expander was placed on the anterior body between the sternum and umbilicus with a baseline of 70 mL sterile saline (0.9% NaCl). The first injection into the tissue expander began on the 6th day after expander insertion, and injections continued every 2 days with approximately 30-70 mL per injection according to the expansion of the skin. The expander reached 335 mL after six injections and within 10 days. In order to prepare for surgical separation, expansion was completed on the 15th day after insertion. The expanded skin area was estimated to be 180 cm2, which was sufficient to cover both patients' skin deficiencies. The twins presented for surgical separation 6 days following the completion of tissue expansion. Both babies were discharged in good health 1 month after separation.

Six Cases of Diabetic Foot Wounds with Concomitant Skin Malignancies (당뇨발 창상에 동반되는 피부 악성종양 6예)

  • Tae Hun Kwon;Taeseung Lee;Changsik John Park;Yoon Hyo Choi;Kyoung Min Lee
    • Journal of Korean Foot and Ankle Society
    • /
    • v.27 no.1
    • /
    • pp.30-34
    • /
    • 2023
  • Diabetic foot wounds have a significant effect on the health-related quality of life of patients. As diabetic foot wounds are usually chronic and recurrent, it is possible that they can lead to skin malignancies. Several factors can make it difficult to make an early and accurate diagnosis of skin malignancies of the foot in patients with diabetes mellitus. Even though the prevalence of diabetes mellitus and diabetic foot wounds is increasing, currently there are no guidelines for the biopsy of diabetic foot wounds. We have evolved a criterion for the above based on six cases of diabetic foot wounds with concomitant skin malignancies. We recommend that clinicians should broadly consider implementing this criterion when managing patients with diabetic foot wounds.