• 제목/요약/키워드: skin contact time

검색결과 66건 처리시간 0.023초

Study on Reusable Electrodes for Personal Electrocardiography

  • Kim, Jonghoon;Yoon, Gilwon
    • 센서학회지
    • /
    • 제27권5호
    • /
    • pp.340-344
    • /
    • 2018
  • Electrodes are an important part of electrocardiography (ECG); disposable electrodes have been extensively used. However, personal ECG monitoring devices for Internet of Things applications require reusable electrodes. As there have been no systematic studies on the characteristics of reusable electrodes to date, we conducted this study to assess the performance and feasibility of electrodes with different materials. We built reusable electrodes using twelve different metallic materials, including commonly used copper, silver, zinc, plating materials, chemically inert titanium, stainless steel, and aluminum. Each electrode was fabricated to a size of $5{\times}10mm$. Their characteristics such as offset, baseline drift, stabilization time, and chemical inertness were compared. A personal ECG monitoring system was used to test the manufactured electrodes. The performances of the Ag, Cu, and Zn electrodes were better than the performances of other electrodes. However, these materials may not be used owing to the chemical changes that occur when the electrodes are in contact with the skin, such as discoloration and corrosion, which deteriorate their electrical characteristics. Titanium, stainless steel, and aluminum are chemically stable. The titanium electrode showed the best performance among the three, and it is our recommendation as a material for manufacturing reusable electrodes.

어린이집 주요 바닥마감재의 경제성 및 LCCO2 분석에 관한 연구 (A study on the economic feasibility and the LCCO2 of Main floor covering materials in day care centers)

  • 김동필;조규만
    • 교육녹색환경연구
    • /
    • 제12권1호
    • /
    • pp.25-34
    • /
    • 2013
  • As the construction industry develops, environmental pollution gets increasingly serious, giving damage including the increase of incidence of respiratory diseases and skin diseases among children with weakened immune systems, rather than adults. In daycare centers, infants and children spending much of their time, have high frequency of contact with the interior floor finish material. However, the majority of the child care centers don not use eco-friendly flooring but ordinary monorium flooring, because the initial investment cost of the eco-friendly flooring is higher than ordinary monorium flooring. Therefore, in this study, life cycle costs including the initial investment cost of the eco-friendly flooring and ordinary monorium flooring were calculated, demonstrating that the eco-friendly flooring is more economical than ordinary monorium flooring in terms of life-cycle cost. In addition, the analysis of the environmental performance also showed the excellence of the eco-friendly floor finishes. It is expected that the use of the eco-friendly floor finishes will increase due to their excellence in the aspect of life cycle cost and eco-friendly performance, through this study.

Real Time ECG Monitoring Through a Wearable Smart T-shirt

  • Mathias, Dakurah Naangmenkpeong;Kim, Sung-Il;Park, Jae-Soon;Joung, Yeun-Ho
    • Transactions on Electrical and Electronic Materials
    • /
    • 제16권1호
    • /
    • pp.16-19
    • /
    • 2015
  • A wearable sensing ECG T-shirt for ubiquitous vital signs sensing is proposed. The sensor system consists of a signal processing board and capacitive sensing electrodes which together enable measurement of an electrocardiogram (ECG) on the human chest with minimal discomfort. The capacitive sensing method was employed to prevent direct ECG measurement on the skin and also to provide maximum convenience to the user. Also, low power integrated circuits (ICs) and passive electrodes were employed in this research to reduce the power consumption of the entire system. Small flexible electrodes were placed into cotton pockets and affixed to the interior of a worn tight NIKE Pro combat T-shirt. Appropriate signal conditioning and processing were implemented to remove motion artifacts. The entire system was portable and consumed low power compared to conventional ECG devices. The ECG signal obtained from a 24 yr. old male was comparable to that of an ECG simulator.

초음파 검사용 젤과 젤 용기의 세균증식 원인 (Causes of Bacterial Growth in Gels and Gel Containers Used for Ultrasonography)

  • 김아영;조평곤;송도영;김수정
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제43권5호
    • /
    • pp.359-365
    • /
    • 2020
  • This study aimed to investigate the causes of bacterial growth to prevent infection caused by ultrasound gel and gel containers in contact with patients during ultrasonography. To investigate bacterial contamination during manufacturing or storage, we cultured ultrasound gels originally supplied from three manufacturers. To analyze bacterial growth according to the lapse of time and frequency of use of the ultrasound gel container, the gel and container were cultured at regular intervals every week for 4 weeks. In addition, to determine the source of infection, the examiner's hand was inspected with hand plate and the degree of bacterial contamination was measured before the test. As a result of the study, bacteria were not detected in the gel provided at the initial supply, and in the gel and gel container used repeatedly for 4 weeks, the same bacteria residing on the skin were identified in the examiner's hand, such as Staphylococcus epidermidis, Micrococcus luteus, Leuconostoc mesenteroid spp cremoris, Kocuria rhizophila, and etc. Separated strains were classified as those of the low- or non-pathogenicity; however, most of these strains may render fatal consequences to patients of lower level of immunity due to acquired tolerance to antibiotics. At week 1, when the number of tests was the highest, 44 colonies were identified, and at week 4, when the number of tests was the lowest, 4 colonies were identified. As r=0.994, it was found that the number of colonies increased as the number of tests increased. In conclusion, it was confirmed that the cause of the infection was not the ultrasound gel, but the examiner's hand. The ultrasound gel or gel container may be contaminated by skin flora of examiner's hands, which can cause opportunistic infection in patients with low immunity. The ultrasound gel or gel container may be contaminated by skin flora of examiner's hands, which can cause opportunistic infection in patients with low immunity. Therefore, it was confirmed that thorough hand disinfection was necessary to block healthcare-associated infections.

Amino Acid-Based Material for the Complementary Therapy of Decubitus Ulcers

  • Nogueira, Frederico;Gouveia, Isabel C.
    • Journal of Microbiology and Biotechnology
    • /
    • 제27권4호
    • /
    • pp.747-758
    • /
    • 2017
  • Chronic wounds, pressure sores, lesions, and infections of microbial origin in bedridden, paralyzed, or malnutrition patients remain the object of study of many researchers. A variety of factors behind the development of these disorders are related to the patient's immune system, making it unable to respond effectively to the treatment of the wound. These factors can be properly controlled, giving particular importance to the ethiology and stage of the wound, as well as the time periods corresponding to the replacement of the dressings. The present research reports a novel foam/soft material, ${{\small}L}$-Cys-g-PCL, with an application for decubitus/pressure ulcers, especially for wounds with a difficult healing process due to infections and constant oxidation of the soft tissues. During this work, the interactions between S. aureus and ${{\small}L}$-Cys-g-PCL foam were studied under conditions that simulate decubitus ulcers; namely, pH and exudate. The effects of duration of grafting (1 or 8 h) and pH (7.0 and 8.9) on wettability, surface energy, swelling, and porosity were also evaluated. Results showed an effective microbicidal activity exhibiting an inhibition ratio of 99.73% against S. aureus. This new ${{\small}L}$-Cys-g-PCL soft material showed saftey to contact skin, ability to be shaped to fill in sunken holes (craters) - pressure ulcers stage III - and to act as a smart material responsive to pH, which can be tailored to develop better swelling properties at alkaline pH where exudates are normally higher, so as to address exudate self-cleaning and prevention of desiccation.

Brief, Intense TENS 자극이 신경전도, 통증역치의 변화에 미치는 효과 (The effects of Breif, Intense Transecutaneous Electrical Nerve Stimulation on Nerve conduction, Pain Threshold in Healthy subjects)

  • 김태열;황태연;허춘복
    • The Journal of Korean Physical Therapy
    • /
    • 제6권1호
    • /
    • pp.171-183
    • /
    • 1994
  • Purphose. This present study examines the effect of brief, intense transcutaneous electrical nerve stimulation(BTENS) on sensory nerve conduction, electrical pain threshold, and two-point discrimination measured at the superficial radial nevre distribution in 20 healthy subjects. Subjects. Twenty volunteercs, (10 females and 10 males(age range : 20-38 years : $mean{\pm}SD\;:\;27.00{\pm}5.12$), only subjects without prior traumatological and pathological were eligible to participated in this study. Methods. Nerve conduction were determined for the right superficial radial nerve. Electrical pain threshold were determined for the right wrist ipsilateral to the site of BTENS. Small disc electrodes were attached to the surface of the skin stradding the end of the radius. Square wave electrical pulses were delivered from an isolated stimulator through a constant current device at a frequency of 2 Hz(5 ms pulse width). Two-point discrimination, measured on the sensory distribution of superficial radial nerve. BTENS was delivered using a Max-SD( Medical design co.) portable battery powered stimulator. A cicular Ag/AgCl electrode in contact with hypertonic saline gel was attached to the lateral(radial side) surface of the forearm. Results. No significant effects were observed between stimulation methods in the prestimulation cycle(multi-way ANOVA repeated measures : distal latency ; F1.14=0.332. amplitude ; F 0.80=0.445, pain threshold ; F0.06=0.940.2 point discrimination ; F1.50=0.236). Highly significant effects were observed time with the pretreatment and 6 posttreatment cycles(p<0.01). Mighty significants differences in nerve conduction and pain threshold were found using un multi-way ANOVA repeated measures among stimulation methods for each cycles(p<0.01). Conclusion and Discussion The authors concludes that both nerve conduction and pain threshold changes are associated with therapy (stimulation) level of BTENS.

  • PDF

비접촉 방식의 생체 신호 측정을 위한 도플러 레이더 시스템 (Doppler Radar System for Noncontact Bio-signal measurement)

  • 신재연;조성필;장병준;박호동;이윤수;이경중
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2009년도 정보 및 제어 심포지움 논문집
    • /
    • pp.357-359
    • /
    • 2009
  • In this paper, the 2.4GHz doppler radar system consisting of the doppler radar module and a baseband module were designed to detect heartbeat and respiration signal without direct skin contact. A bio-radar system emits continuous RF signal of 2.4GHz toward human chest, and then detects the reflected signal so as to investigate cardiopulmonary activities. The heartbeat and respiration signals acquired from quadrature signal of the doppler radar system are applied to the pre-processing circuit, amplification circuit, and the offset circuit of the baseband module. ECG(electrocardiogram) and reference respiration signals are measured simultaneously to evaluate the doppler radar system. As a result, the respiration signal of doppler radar signal is detected to 1m without complex digital signal processing. The sensitivity and calculated from I/Q respiration signal were $98.29{\pm}1.79%$, $97.11{\pm}2.75%$, respectively, and positive predictivity were $98.11{\pm}1.45%$, $92.21{\pm}10.92%$, respectively. The sensitivity and positive predictivity calculated from phase and magnitude of the doppler radar were $95.17{\pm}5.33%$, $94.99{\pm}5.43%$, respectively. In this paper, we confirmed that noncontact real-time heartbeat and respiration detection using the doppler radar system has the possibility and limitation.

  • PDF

근전도와 안전도 기반의 인간-기계 인터페이스기술 (Development of Human-machine Interface based on EMG and EOG)

  • 강경우;김태선
    • 전자공학회논문지
    • /
    • 제50권12호
    • /
    • pp.129-137
    • /
    • 2013
  • 최근 다양한 컴퓨터기반 장치들의 사용 확대에 따라 장애인에게도 정보접근의 용이성 확보가 요구되고 있다. 특히 사지를 움직일 수 없는 중증 장애인들을 위한 새로운 입력 인터페이스 기술의 개발이 절실히 요구된다. 이를 위해 본 논문에서는 중증 장애인이 활용 가능한 눈동자 움직임 및 깨물기를 통한 안전도(EOG)와 근전도(EMG)신호를 이용하여 아홉 가지의 명령이 가능한 인터페이스 시스템을 개발하였다. 구현된 시스템은 하드웨어로 구성된 센서모듈과 특징추출 및 패턴분류를 포함하는 소프트웨어부로 구성된다. 개발된 기술은 사용자의 편의성을 극대화하기 위해 두 개의 전극만을 이마부위에 부착하여 안전도와 근전도를 동시에 측정하고, 이를 통해 아홉 가지의 명령전달이 가능하도록 하였다. 성능평가를 위한 java 기반 실시간 모니터링 프로그램의 실험결과 92.52%의 인식률을 보였다. 또한, 구현된 시스템의 실용성을 입증하기 위해 다섯 종류의 명령을 이용하여 ER1 로봇의 조종에 성공적으로 적용 가능함을 보임으로써 장애인을 위한 새로운 인터페이스로서의 가능성을 보였다.

영유아기 어머니의 양육행위에 관한 내용분석 (Content Analysis of Child Rearings of Mothers in Infant and Child Preschool)

  • 박선정
    • Child Health Nursing Research
    • /
    • 제20권1호
    • /
    • pp.39-48
    • /
    • 2014
  • 목적 영유아를 돌보는 어머니의 양육행위를 파악하여 양육행위 형태를 확인하고자 한다. 방법 본 연구는 60개월 이하의 영유아를 양육하는 어머니의 양육행위와 관련된 구체적인 경험이나 인식을 질적, 양적으로 파악하고자 내용분석을 실시한 연구이다. 결과 양육행위에 대한 내용을 긍정적 강화와 부정적 강화로 양육행위를 분류하여 내용 분석한 결과 총 55개의 의미 있는 진술문과 14개의 범주로 도출되었다. 첫째, 긍정적 강화영역으로는 "잦은 피부 접촉", "즐겁게 해줌", "자녀와의 많은 시간 가짐", "자녀의 자존감 향상", "자녀의 요구에 대한 민감", "올바른 훈육", "독립적 양육", "자녀의 의견 경청", "자녀의 감정 이해 및 존중" 9개의 범주로 나타났다. 둘째, 부정적 강화영역으로 범주화된 내용으로는 "과잉보호", "비 일관적인 태도", "방임", "부정적 훈육 행위", "권위적 순종 강조" 5개의 범주로 나타났다. 결론 어머니의 양육행위에 대한 내용을 확인하고 변화를 위해서는 교육을 좀 더 구체적이며 체계적으로 운영하며 개개인의 양육행위에 대한 방법을 고려하여 적합한 교육 프로그램의 개발을 통해 추후 효과를 높일 수 있을 것이라고 생각된다.

ALD 설비의 NH3(Ammonia)누출 시나리오에 대한 내부유동 및 제어 속도 해석 (Analysis of Internal Flow and Control Speed for NH3 (Ammonia) Leakage Scenario of ALD Facility)

  • 이성삼;안형환
    • 한국가스학회지
    • /
    • 제26권5호
    • /
    • pp.22-27
    • /
    • 2022
  • 반도체 생산 설비 중 ALD는 열이나 플라즈마로 분해한 Gas를 Wafer에 증착시켜 원자층을 형성시키는 설비로 주로 인화성 물질인 NH3와 SIH4이 사용된다. 이중 NH3는 연소·폭발 범위가 상한(UFL) 33.6%, 하한(LEL) 15%로 폭발 범위가 비교적 좁지만 많은 양이 갑자기 한곳에 모이면 폭발할 수 있고, 피부에 닿거나 흡입하면 치명적이다. NH3는 ALD Gas inlet의 배관과 전기·기계 기구를 통해 Chamber로 공급되는데 많은 누출 가능점이 존재하여 누출 시 화재·폭발 또는 중독 사고로 이어질 수 있어 NH3 누출 시나리오에 대한 내부 유동과 제어 속도를 이해하고 고환기가 가능한 배기장치를 설계하는 것이 필요하여 본 연구자는 NH3의 누출시나리오를 CFD에 적용하여 내부유동과 제어 속도를 수치 분석하여 설계 시 반영할 수 있도록 하였다.