• Title/Summary/Keyword: skin cancer

Search Result 873, Processing Time 0.032 seconds

8MHz RF Capacitive Heating on Rabbit Lung (가토의 정상폐의 고주파 유전형 가온에 관한 연구)

  • Jang, Hong, Seok;Kim, Jong-Woo
    • Radiation Oncology Journal
    • /
    • v.10 no.1
    • /
    • pp.1-6
    • /
    • 1992
  • The usefulness of hyperthermia for cancer therapy has been established. The purpose of the present investigation was to access feasibility of heating normal lung and the temperature and power requirement were compared with that for liver as solid organ in rabbits by using radiofrequent heating machine. In this study, 20 rabbits were divided into 2 groups according to the heating site and the method of temperature measurement; in group I : lung heating and temperature measuring in skin, esophagus and lung parenchyme; in group II : liver heating and temperature measuring in skin and liver parenchyme. The results were as follows; 1) When the maximum temperature was almost same in lung heating group and liver heating group, the power for liver heating was lesser required than the power for lung heating (p<0.05). 2) The temperature of esophagus for the measurement of mediastinum temperature was $1.1{\pm}0.9^{\circ}C$ higher than the temperature of lung parenchyme (p<0.05). Therefore the above findings suggest lung, air containing organ, is well heated as same as liver, solid organ. So more active trials of lung heating in the lung cancer must be likely considered. But when the lung is heated, the esophageal temperature is higher than lung parenchyme, so the mediastinum damage must be considered seriously.

  • PDF

Evaluation of Difference between Skin Motion and Tumor Motion for Respiration Gated Radiotherapy (호흡조절방사선치료를 위한 피부움직임과 종양움직임 차이 평가)

  • Kwon, Kyung-Tae;Lim, Sang-Wook;Park, Sung-Ho;Kwon, Soo-Il;Shin, Sung-Soo;Lee, Sang-Wook;Ahn, Seung-Do;Kim, Jong-Hoon;Choi, Eun-Kyung
    • Progress in Medical Physics
    • /
    • v.19 no.1
    • /
    • pp.14-20
    • /
    • 2008
  • Accounting for tumor motion in treatment planning and delivery is one of the most recent and significant challenges facing radiotherapy. The purpose of this study was to investigate the correlation and clarified the relationship between the motion of an external marker using the Real-Time Position Management (RPM) System and an internal organ motion signal obtained fluoroscope. We enrolled 10 patients with locally advanced lung cancer and liver cancer, retrospectively. The external marker was a plastic box, which is part of the RPM used to track the patient's respiration. We investigated the quantitatively correlation between the motions of an external marker with RPM and internal motion with fluoroscope. The internal fiducial motion is predominant in the caraniocaudal direction, with a range of $1.3{\sim}3.5cm$ with fluoroscopic unit. The external fiducial motion is predominant in the caraniocaudal direction, with a range of $0.43{\sim}2.19cm$ with RPM gating. The two measurements ratio is from 1.31 to 5.56. When the regularization guided standard deviation is from 0.08 to 0.87, mean 0.204 cm, except only for patients #3 separated by a mean 0.13 cm, maximum of 0.23 cm. This result is a good correlation between internal tumor motion imaged by fluoroscopic unit and external marker motion with RPM during expiration within 0.23 cm. We have demonstrated that gating may be best performed but special attention should be paid to gating for patients whose fiducials do not move in synchrony, because targeting on the correct phase difference alone would not guarantee that the entire tumor volume is within the treatment field.

  • PDF

Radiotherapy Results for Recurrent Uterine Cervical Cancer after Surgery (수술 후 국소재발한 자궁경부암에서의 방사선치료 성적)

  • Ryu Mi Ryeong;Kay Chul Seung;Kang Ki Moon;Kim Yeon Shil;Chung Su Mi;Namkoong Sung Eun;Yoon Sei Chul
    • Radiation Oncology Journal
    • /
    • v.17 no.3
    • /
    • pp.217-222
    • /
    • 1999
  • Purpose : To evaluate prognostic factors and survival rates of the patients who received radiation therapy for locally recurrent uterine cervical cancer after curative surgery. Materials and Methods : Between October 1983 and July 1990, fifty three patients who received radiation therapy for locally recurrent cervical cancer after curative surgery at the Department of Therapeutic Radiology, Kangnam St. Mary's Hospital, The Catholic University of Korea were analysed retrospectively. Age at diagnosis ranged from 33 to 69 years (median 53 years). Pathological analysis showed that forty five ($84.9\%$) patients had squamous cell carcinoma, seven ($13.2\%$) patients had adenocarcinoma, and one (1.9%) patient had adenosquamous cell carcinoma. The interval between hysterectomy and tumor recurrence ranged from 2 months to 25 years (mean 34.4 months). The recurrent sites were vaginal stump in 41 patients ($77.4\%$) and pelvic side wall in 12 patients ($22.6\%$). Recurrent tumor size was devided into two groups : less than 3 cm in 43 patients ($81.1\%$) and more than 3 cm in 10 patients ($18.9\%$). External beam irradiation of whole pelvis was done first up to 46.8 Gy to 50.4 Gy in 5 weeks to 6 weeks, followed by either external beam boost to the recurrent site in 18 patients ($34\%$) or intracavitary irradiation in 24 patients ($45.3\%$). Total dose of radiation ranged from 46.8 Gy to 111 Gy (median 70.2 Gy). Follow up period ranged from 2 to 153 months with a median of 35 months. Results : Overall response rate was $66\%$ (35/53). Among them, six patients ($17.1\%$) relapsed between 7 months and 116 months after radiation therapy (mean 47.7 months), Therefore overall recurrence rate was $45.3\%$. Overall five-year actuarial survival rate was $78.9\%$ and distant failure rate was $10\%$ (5/50). The significant prognostic factors affecting survival rate were interval between primary surgery and tumor recurrence (p=0.0055), recurrent tumor size (p=0.0039), and initial response to radiation therapy (p=0.0428). Complications were observed in 10 ($20/%$) patients, which included mild to moderate lower gastrointestinal, genitourinary, or skin manifestations. One patient died of pulmonary embolism just after intracavitary irradiation. Conclustion : Radiation therapy is the effective treatment for the patients with locally recurrent cervical cancer after curative surgery. These results suggest that interval between primary surgery and tumor recurrence, recurrent tumor size, and initial response to radiation therapy were significant prognostic factors for recurrent cervical cancer.

  • PDF

A Study on the Establishment of Management Methods about Occupational Dermatoses (직업성 피부질환에 대한 현황 파악 및 관리 대책 수립을 위한 연구)

  • Lim, Hyun-Sul;Cheong, Hae-Kwan;Choi, Byung-Soon;Kim, Ji-Yong;Sung, Yeol-Oh;Kim, Yang-Ho
    • Journal of Preventive Medicine and Public Health
    • /
    • v.29 no.3 s.54
    • /
    • pp.617-637
    • /
    • 1996
  • Occupational dermatosis is one of the most prevalent occupational disorders. However, the extent of the occupational dermatoses including incidences and prevalencies of each disease entity, and etiologic materials are not yet welt stated in Korea. Authors reviewed the literatures on the statistic data and reports on the occupational dermatoses, and surveyed on the occupational dermatoses in two factories, and surveyed the physicians responsible to the occupational dermatoses with formed questionnaire. The results are as follows; 1. Among medical journals published since 1964, there were 31 articles on the occupational dermatoses. Of 31 articles, 18 were case reports and all others were review articles. Of 18 case reports, 9 were epidemiologic survey. The Workers' Periodic Health Examinations revealed that prevalence of the occupational dermatoses was highest(4.36 per 10,000 workers) in 1974, but number of the cases reported were decreased sharply since 1978 with some tendency to increase since 1981. There were 2,240 reported cases of occupational dermatoses between 1966 and 1992, which is 1.90% of all the reported occupational diseases. Skin infection and injuries due to chemicals were most frequent and there were 6 cases of skin cancer. 2. In an epidemiological survey on the dermatoses among 995 workers in a metal product manufacturing factory and 225 workers in a coal chemical factory, there were 794 with dermatomycosis, 296 workers with acne, 130 workers with scar, 123 workers with deformity of toe nails. Scars, photosensitivity dermatitis, deformity of finger and toe nails, and acne were more prevalent in the metal product manufacturing factory(p<0.05). In the metal prouct manufacturing factory, workers treating organic solvents and oils had more dermatoses than those without treating the materials(p<0.05). On the skin patch performed on 16 workers in the metal product manufacturing factory, there were 8 cases of irritation dermatitis and 5 cases of contact dermatitis. Prevalence of contact dermatitis in the metal product manufacturing factory was 1.3%. 3. On the questionnaire survey, 34 dermatologists, 29 doctors of preventive medicine, and 22 family physician replied. The proportion of occupational etiology among all dermatoses assumed by the physicians were below 9%, and the most important occupational dermatosis in Korea was contact dermatitis. Main etiologic materials related to the occupational dermatosis were organic solvent, acid and alkali, and metals. The reason for the scarcity of report of occupational dermatoses were difficulty in diagnosis and physician's ignorance of the occupational etiology. They replied that to prevent the occupational dermatoses in the workplace, the use of protective devices was most important, and development of diagnostic criteria on the occupational dermatoses is urgent. Above results shows us that there is many workers with occupational dermatoses, but they are mostly unreported. Measures to prevent and manage the occupational dermatoses are not satisfactory at present. Hence, authors suggest measures for the precise diagnosis, report and prevention of the occupational dermatoses. a. Dermatologist, preventive physician, and industrial hygienist should work as a team to examine the high risk group and establish the preventive measures. b. Disease entities, diagnostic criteria of occupational dermatoses should be listed, criteria for the compensation and job fitting at recruitment should be established, and manual for the proper treatment and effective prevention of each occupational dermatosis should be developed. c. Patch test antigens against each occupational category should be developed and it should be available to any physicians responsible. d. To facilitate the diagnosis of occupational dermatoses by the doctors responsible for the Workersr Periodic Health Examination, development of standardized questionnaire, education on the techniques of the patch test, and cooperation with the dermatologist in diagnosis of occupational dermatoses is essential.

  • PDF

The evaluation of dose of TSEI with TLD and diode dector of the uterine cervix cancer (열형광선량계와 반도체검출기를 이용한 전신피부전자선조사의 선량평가)

  • Je Young Wan;Na Keyung Su;Yoon IL Kyu;Park Heung Deuk
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.17 no.1
    • /
    • pp.57-71
    • /
    • 2005
  • Purpose : To evaluate radiation dose and accuracy with TLD and diode detector when treat total skin with electron beam. Materials and Methods : Using Stanford Technique, we treated patient with Mycosis Fungoides. 6 MeV electron beam of LINAC was used and the SSD was 300 cm. Also, acrylic speller(0.8 cm) was used. The patient position was 6 types and the gantry angle was 64, 90 and $116^{\circ}$. The patient's skin dose and the output were detected 5 to 6 times with TLD and diode. Result : The deviations of dose detected with TLD from tumor dose were CA $+\;6\%$, thigh $+\;8\%$, umbilicus $+\;4\%$, calf $-\;8\%$, vertex $-\;74.4\%$, deep axillae $-\;10.2\%$, anus and testis $-\;87\%$, sole $-\;86\%$ and nails shielded with 4mm lead $+4\%$. The deviations of dose detected with diode were $-4.5\%{\sim}+5\%$ at the patient center and $-1.1\%{\sim}+1\%$ at the speller. Conclusion : The deviation of total skin dose was $+\;8\%{\sim}-\;8\%$ and that deviation was within the acceptable range(${\pm}\;10\%$). The boost dose was irradiated for the low dose areas(vertex, anus, sole). The electron beam output detected at the sootier was stable. It is thought that the deviation of dose at patient center detected with diode was induced by detection point and patient position.

  • PDF

Protective Effects of an Ethanol Extract of Elaeagnus umbellata Leaves on α-MSH-induced Melanin Production in B16-F0 Cells and UVB-induced Damage in CCD-986sk Cells (보리수나무 잎 에탄올 추출물이 α-MSH 유도 B16-F0 세포의 멜라닌 생성 및 UVB 유도성 CCD-986sk 세포 손상에 미치는 효과)

  • Park, Se-Ho;Jhee, Kwang-Hwan;Yang, Seun-Ah
    • Journal of Life Science
    • /
    • v.29 no.5
    • /
    • pp.555-563
    • /
    • 2019
  • This study was undertaken to investigate the effect of an ethanol extract of Elaeagnus umbellata leaves (EUL-EE) on skin-related biological activities. Previously, we have reported that gallic acid was the major phenolic compound in EUL-EE through quantitative analysis and that EUL-EE had an inhibitory effect against the proliferation of liver cancer HepG2 cells. In the present study, the inhibitory effects of EUL-EE on melanin production and tyrosinase activity in ${\alpha}$-melanocyte-stimulated hormone-stimulated B16-F0 cells were determined to assess the effects of EUL-EE on skin whitening. The anti-wrinkle effect using UVB-irradiated CCD-986sk cells was examined by the expression of type I procollagen and metalloproteinase (MMP)-1 release. The EUL-EE significantly decreased intracellular melanin production (33.0% inhibition at $100{\mu}g/ml$) when compared with untreated B16-F0 cells. Tyrosinase activities in the stimulated B16-F0 cells were also decreased by EUL-EE (47.8% inhibition at $100{\mu}g/ml$). The EUL-EE also dose-dependently increased the production of type I procollagen (up to 1.74-fold at $250{\mu}g/ml$) in CCD-986sk cells when compared with UVB-irradiated controls. EUL-EE showed no cytotoxicity at concentrations up to $500{\mu}g/ml$. In addition, EUL-EE at $10-500{\mu}g/ml$ inhibited the release of MMP-1 to the medium from UVB-irradiated CCD-986sk cells. Taken together, these observations indicate that EUL-EE has high potential for use as inner beauty and cosmetic materials due to its whitening and anti-wrinkle effects.

Evaluation of compensator to reduce thermal sensation in oncological hyperthermia (고주파 온열암 치료 시 열감감소를 위해 자체 제작한 보상체의 유효성 평가)

  • Lee, Yeong Cheol;Kim, Sun Myung;Jeong, Deok Yang;Kim, Young Bum
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.2
    • /
    • pp.27-32
    • /
    • 2017
  • Objectives: Oncological hyperthermia is a treatment to selectively kill cancer cells by directly applying heat to cancer cells or indirectly demage cancer cells. One of the most side effects of treatment is burn that can appear on the skin. In areas with irregularities such as the umbilicus, the patient feels a sense of hot and treatment may be discontinued. Therefore, in order to eliminate the irregularities of these areas, compensators are manufactured and measured to decrease in temperature. Materials and Methods: The temperature of the four sites (umbilicus, near the umbilicus, 5 cm below the umbilicus, back) was measured five times around the umbilicus in patients who were treated at oncological hyperthermia treatment device(EHY-2000, Oncotherm Kft, Hungary). The temperature sensor (TM-100, Oncotherm Kft, Hungary) was attached to four sites and the changes were observed at 5, 15, 25, 35, and 50 minutes after treatment. Compensators of three materials were used(Vaseline, Bolus, Dental resin). The data measured five times were compared for each compensator. Results: The temperature change when the compensator was not used increase from 34.65 degrees to 42.9 degrees on average. The near umbilicus was changed from 32.20 degrees to 37.00 degrees, and the 5 cm below the umbilicus was changed from 31.90 to 34.41 degrees. When the compensator material was inserted into the umbilicus, the temperature change was measured as 5.42 degrees for bolus, 6.55 degrees for vaseline, and 6.83 degrees for resin. Conclusion: Using the compensator in the region where the irregularities such as the umbilicus, the heat sensation could be reduced. the use of a resin that can be customized not only lowers the temperature but also significantly reduces the feeling of the patient. It will be possible to reduce the heat sensation in the treatment and to treat it in a more comfortable condition.

  • PDF

Research of 6 MeV Electron Dose Distribution (6 MeV Electron Therapy에서의 Electron Dose Distribution에 관한 연구)

  • Je Jae-Yong;Park Chul-Woo;Jin Sung-Jin;Park Eun-Tae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.17 no.2
    • /
    • pp.161-166
    • /
    • 2005
  • Purpose : Electron is used for the treatment of skin cancer, breast cancer, and head and neck cancer in clinic. Our study is performed to check the isodose distribution in source surface distance(SSD)and source bolus distance(SBD)setup, nipple influence to isodose distribution of electron, junctional area isodose variation of photon and electron field. Materials and Methods : The electron dose distribution measures the diameter for 20 cm hemisphere paraffin phantom 2 made. It inserted the film between 2 paraffin phantom and it investigated it got radiation and dose distribution curve. Results : The 8% of isodose difference is with the surface distance(SSD)and source bolus distance(SBD)setup. The electon when the nipple exists inside the field, as nipple size it cuts the bolus and when it puts out and there is a possibility of getting the dose distribution which is homogeneous. When in the junction of electron and photon it uses the bolus it uses in the electron field whole, there is a possibility of getting the dose distribution which is homogeneous. Conclusion : The dose distribution decrease from the SBD setup. To reduce the influence of nipple, corresponding volume of bolus should be removed. And bolus covering all the electron field reduced hot and cold spot of junctional area of photon. In the future becomes the research which sees an effective electron therapy.

  • PDF

Comparison and evaluation between 3D-bolus and step-bolus, the assistive radiotherapy devices for the patients who had undergone modified radical mastectomy surgery (변형 근치적 유방절제술 시행 환자의 방사선 치료 시 3D-bolus와 step-bolus의 비교 평가)

  • Jang, Wonseok;Park, Kwangwoo;Shin, Dongbong;Kim, Jongdae;Kim, Seijoon;Ha, Jinsook;Jeon, Mijin;Cho, Yoonjin;Jung, Inho
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.1
    • /
    • pp.7-16
    • /
    • 2016
  • Purpose : This study aimed to compare and evaluate between the efficiency of two respective devices, 3D-bolus and step-bolus when the devices were used for the treatment of patients whose chest walls were required to undergo the electron beam therapy after the surgical procedure of modified radical mastectomy, MRM. Materials and Methods : The treatment plan of reverse hockey stick method, using the photon beam and electron beam, had been set for six breast cancer patients and these 6 breast cancer patients were selected to be the subjects for this study. The prescribed dose of electron beam for anterior chest wall was set to be 180 cGy per treatment and both the 3D-bolus, produced using 3D printer(CubeX, 3D systems, USA) and the self-made conventional step-bolus were used respectively. The surface dose under 3D-bolus and step-bolus was measured at 5 measurement spots of iso-center, lateral, medial, superior and inferior point, using GAFCHROMIC EBT3 film (International specialty products, USA) and the measured value of dose at 5 spots was compared and analyzed. Also the respective treatment plan was devised, considering the adoption of 3D-bolus and stepbolus and the separate treatment results were compared to each other. Results : The average surface dose was 179.17 cGy when the device of 3D-bolus was adopted and 172.02 cGy when step-bolus was adopted. The average error rate against the prescribed dose of 180 cGy was -(minus) 0.47% when the device of 3D-bolus was adopted and it was -(minus) 4.43% when step-bolus was adopted. It was turned out that the maximum error rate at the point of iso-center was 2.69%, in case of 3D-bolus adoption and it was 5,54% in case of step-bolus adoption. The maximum discrepancy in terms of treatment accuracy was revealed to be about 6% when step-bolus was adopted and to be about 3% when 3D-bolus was adopted. The difference in average target dose on chest wall between 3D-bolus treatment plan and step-bolus treatment plan was shown to be insignificant as the difference was only 0.3%. However, to mention the average prescribed dose for the part of lung and heart, that of 3D-bolus was decreased by 11% for lung and by 8% for heart, compared to that of step-bolus. Conclusion : It was confirmed through this research that the dose uniformity could be improved better through the device of 3D-bolus than through the device of step-bolus, as the device of 3D-bolus, produced in consideration of the contact condition of skin surface of chest wall, could be attached to patients' skin more nicely and the thickness of chest wall can be guaranteed more accurately by the device of 3D-bolus. It is considered that 3D-bolus device can be highly appreciated clinically because 3D-bolus reduces the dose on the adjacent organs and make the normal tissues protected, while that gives no reduction of dose on chest wall.

  • PDF

Golfers' Intention to Adopt UV Specialized Clothing as Innovation: Based on Rogers Theory (골퍼의 자외선 차단의복의 수용 의도: Rogers의 혁신확산이론을 중심으로)

  • Sung Heewon;Slocum Ann C.
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.28 no.12 s.138
    • /
    • pp.1554-1561
    • /
    • 2004
  • In the U.S., outdoor enthusiasts such as golfers have been focused on skin cancer prevention practices since their outdoor activities lead to extensive sun exposure during peak sun hours. The purposes of this study were to investigate golfers current sun protection behaviors and five attributes and their impacts on the intention to adopt UV specialized clothing based on Rogers' theory. UV specialized clothing as a preventive innovation is related to sun protection behaviors. However, there has been little effort to explain the intention to adopt a preventive innovation regarding health-related practices. With a convenience sampling method, a total of 158 useful questionnaires were collected. Ninety one percent were male golfers, and their age ranged from 16 to 80 years old(mean age=30 years). About $25\%$ reported to practice sun protection behaviors. About $70\%$ disagreed on the relative advantage, compatibility, observability, and triability of UV specialized shirts and reported the low intention to purchase it. Current sun protection behaviors and five attribute variables were entered in the multiple regression equation to explain the dependent variable of intention to adopt the innovation. Triability was the best predictor of the intention to adopt UV specialized shirts, followed by current sun protection behaviors, compatibility, and relative advantage. With four predictors, $45\%$ of the variance of intention to adopt was explained. The present study provides how the golfers current sun protection behaviors play important roles in explaining the intention to adopt the preventive innovation. Physical and functional features of UV specialized clothing were also significantly associated with their intentions to adopt it.