• 제목/요약/키워드: skin blood flow

검색결과 146건 처리시간 0.027초

The effect of coenzyme Q10 on endothelial function in a young population

  • Petrofsky, Jerrold;Laymon, M.;Lee, H.;Hernandez, E.;Dequine, D.;Thorsen, L.;Lovell, R.;Andrade, J.
    • Physical Therapy Rehabilitation Science
    • /
    • 제1권1호
    • /
    • pp.6-12
    • /
    • 2012
  • Objective: Coenzyme (CoQ10) is an enzymatic co factor used in normal cellular metabolism. Recent evidence shows that in people with heart disease it can reverse endothelial cell damage in the blood vessels. It is also a potent antioxidant. Design: One group pretest-posttest design. Methods: In the present study, endothelial function was evaluated using the response to occlusion and heat before and 2 weeks after administration of CoQ10, 300 mg/day. Thirty Eight subjects, who are physical therapy students, participated in a series of experiments to see if taking 300 mg of CoQ10 daily for 2 weeks would impact resting blood flow in the forearm skin and the blood flow response to 4 minutes of vascular occlusion and the response to local heat ($42^{\circ}C$) for 6 minutes. Results: The results showed that, for this population, there was no difference in the response to heat. However, the response to occlusion was improved after administration of CoQ10. Conclusions: It would appear that in a young population CoQ10 has no effect on the nitric oxide vasodilator pathway in skin but does influence other vasodilator pathways.

  • PDF

Injury and inflammation detection by the application of microcurrent through the skin

  • Hui, Timothy;Petrofsky, Jerrold
    • Physical Therapy Rehabilitation Science
    • /
    • 제2권1호
    • /
    • pp.31-38
    • /
    • 2013
  • Objective: To determine the efficacy and reliability of measuring direct current microcurrent applied through the skin to determine injury in the underlying tissues. Design: Case control study. Methods: First, microcurrent was measured as decreased blood flow induced hypoxia in healthy subjects. Next, reliability was assessed by measuring over ten days with set variations in pressure and distance between the electrodes. Finally, measurements over sprained ankle were compared to measurements over comparable uninjured areas on the same injured subject. Results: For the blood flow test phase, microcurrent significantly decreased an average of 17% after 5 minutes (p<0.05), remained decreased for 30 seconds, and returned to non-occlusive levels after 2 minutes of normal circulation. The results indicate that the microcurrent decrease was not due to blood flow, and most likely from hypoxic cellular damage. For the reliability phase, the coefficients of variation averaged 10.3% for the shoulder, 14.8% for the low back, and 29.1% for the knee. Changing distance 2.5 cm between the electrodes resulted in insignificant changes. Changes in pressure had some significant effect after an increase in force of 2.6 N, affirming the need for consistent pressure for measurement. For the injury test phase, a significant 69% decrease occurred comparing injured areas to the same area on the uninjured side, and a significant 74% occurred comparing injured and non-injured areas on the same limb. Conclusions: Microcurrent through the skin shows promise as an objective method of assessing a soft tissue injury by detecting damage likely due to hypoxia.

  • PDF

체열진단을 통한 펄스자기장 자극기의 혈류개선효과 고찰 (Effect of Pulse Magnetic Field Stimulus on Blood Flow using Digital Infrared Thermal Imaging)

  • 이현숙
    • 한국자기학회지
    • /
    • 제21권5호
    • /
    • pp.180-184
    • /
    • 2011
  • 자기장 자극시스템을 통하여 순간펄스 고자기장을 손바닥과 발바닥 그리고 무릎에 인가한 후 체열진단시스템을 통하여 모세혈관을 포함한 인체의 혈관 자극에 의한 혈류개선 효과를 연구하였다. 연령별, 성별 구분을 통하여 자극 후 체열진단을 통해 공통적으로 자극부위에 온도가 상승하는 결과를 얻었으며, 자기장 자극기 코일에서 발생하는 자체 발열량을 제거하기 위해 플라스틱 재질의 성형물로 신체와의 직접적인 접촉을 차단시켰으며 일정거리를 유지하여 실험하였다. 그 결과 비접촉을 통하여 순수하게 자기장의 펄스파형이 피부에 가까운 혈관을 자극하여 내부 전자기 에너지가 피부에 온도상승을 가져온 것으로 고찰된다.

흉추에 적용한 척추교정이 피부온도와 주관적 피로에 미치는 영향 (The Changes of Skin Temperature and Subjective Fatigue of the Thoracic Vertebrae by the Chiropractic Adjustments)

  • 윤정규;이건철
    • 대한물리치료과학회지
    • /
    • 제10권1호
    • /
    • pp.102-108
    • /
    • 2003
  • The purpose of this study was to determine the changes of skin temperature and subjective fatigue of the thoracic vertebrae by the chiropractic adjustments. Stimulation of the sympathetic nervous system will cause the changes in the skin blood flow which can be detected by measuring the skin surface temperature. This study was to see whether chiropractic adjustments could affect the activity of the sympathetic nervous system as reflected by changes in skin temperature of the thoracic. Skin temperature and subjective fatigue on 16 subjects was measured before, within 10 sec, 10min, 20min and 30 min after a thoracic adjustment with Digital Infrared Thermal Imaging(DITI) and Visual Analogue Scale(VAS). The adjustments consisted of a straight posterior-to-anterior high-speed, low-amplitude thrust to the transverse process of T3-T10 using a reinforced hypothenar contact. The average temperature and fatigue changed when the spine was considered as an entire unit. These results illustrate that the blood flow through the soft tissue can be affected by specific adjustments to the spine. This study might be served as an useful baseline data for the changes of the circulation and fatigue after the chiropractic adjustments.

  • PDF

Effect of UV Irradiation and Rebamipide on the Blood Flow and Viability of Rabbit Skin Flap

  • Suh, Eung-Joo;Choi, Hyoung-Chul;Sohn, Uy-Dong;Ha, Jeoung-Hee;Lee, Kwang-Youn;Kim, Won-Joon
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제1권5호
    • /
    • pp.581-589
    • /
    • 1997
  • This study was undertaken to examine the effects of ultraviolet light (UVL) and rebamipide on the cutaneous blood flow and tissue survival on rabbit skin flap. In a random bipedicle flap, Laser Doppler Flowmetry (LDF) was employed to measure the blood flow of flap (BFF). Wound Margin Strength (WMS) measured by force transducer and Light microscophy were used for evaluation of tissue viability. Single exposure to UVL increased the BFF gradually for more than 15 hours, and decreased the vasoconstrictor effect of intravenous phenylephrine. The UVL-induced increase in BFF regressed after 18 hours of irradiation, and this regression was tended to be enhanced by intradermal injection of L-NAME, a nitric oxide synthase (NOS) inhibitor, but the regression was significantly reversed by acetylcholine, an endothelial constitutive NOS (cNOS) activator and L-arginine, an NO precusor. Rebamipide, a novel antiulcer agent known to scavenge the hydroxyl radical, abruptly reversed the spontaneous regression of the UVL- induced increase in BFF by the same manner as L-arginine. In ischemic skin flap, rebamipide increased the BFF abruptly by the same manner as sodium nitroprusside (SNP), an NO doner, while N-acetylcystein (NAC), a free radical scavenger, gradually increase the BFF. The rebamipide-induced increase in BFF was sustained at the level of the SNP-induced increase in BFF during the late period of experiment. Rebamipide increased the WMS of skin flaps and prevented the tissue necrosis in comparison with L-NAME. Based on these results, it is concluded that in rabbit skin, UVL irradiation increases the BFF by NO release, and rebamipide exerts a protective effect on the viability of ischemic skin flaps by either or both the increase in BFF by NO release and free radical scavenger effect.

  • PDF

Change in Autonomic Nerve Responses after Low-frequency Transcutaneous Electrical Nerve Stimulation

  • Lee, Jeong-Woo;Park, Ah-Rong;Hwang, Tae-Yeon
    • The Journal of Korean Physical Therapy
    • /
    • 제22권6호
    • /
    • pp.71-76
    • /
    • 2010
  • Purpose: The purpose of this study was to examine changes in autonomic nerve responses after low-frequency transcutaneous electrical nerve stimulation (TENS). Methods: Research subjects were 24 students who attend University. Subjects were divided into two groups: 1 = a low intensity group; 2 = a high intensity group. Electrodes were attached to the forearm of the dominant arm and electrical stimuli were administered for 15 minutes. Outcome measures were skin conduction velocity, skin temperature, blood flow, and pulse frequency, each of which was measured a total of 4 times. The data were analyzed using a repeated measures ANOVA. Results: In changes in conduction velocity, the main effect of time variation (in black) was statistically significant. The interaction between time and group main effects was not statistically significant; nor was the difference between the groups. Results showed that skin conduction velocity changed without any relation to group. Conclusions: Low frequency TENS selectively increases skin conduction velocity, which may be helpful for activating sudomotor function regardless of intensity.

저주파 펄스 전자기장 자극에 의한 피부 조직괴사 완화 효과 (Effect of Skin Tissue Necrosis Relaxation by Low Frequency Pulsed Electromagnetic Fields (LF-PEMF) Stimulation)

  • 이자우;김준영;이용흠
    • 대한의용생체공학회:의공학회지
    • /
    • 제42권1호
    • /
    • pp.25-30
    • /
    • 2021
  • Objective: The aim of this study is to consider the effect of skin tissue necrosis by improving blood flow in animal skin models for low frequency pulsed electromagnetic fields (LF_PEMF) stimulation. Methods: Twenty rats (Wistar EPM-1 male, 280-320 g) were randomly divided into control groups (n=10) and the PEMF groups (n=10). To induce necrosis of the skin tissue, skin flap was treated in the back of the rat, followed by isolation film and skin flap suturing. Subsequently, the degree of necrosis of the skin tissue was observed for 7 days. The control group did not perform any stimulation after the procedure. For the PEMF group, LF_PEMF (1 Hz, 10 mT) was stimulated in the skin flap area, for 30 minutes a day and 7 days. Cross-polarization images were acquired at the site and skin tissue necrosis patterns were analyzed. Results: In the control group, skin tissue necrosis progressed rapidly over time. In the PEMF group, skin tissue necrosis was slower than the control group. In particular, no further skin tissue necrosis progress on the day 6. Over time, a statistically significant difference from the continuous necrosis progression pattern in the control group was identified (p<0.05). Conclusions: It was confirmed that low frequency pulsed electromagnetic fields (LF_PEMF) stimulation can induce relaxation of skin tissue necrosis.

자기혼합형 반도체 레이저를 이용한 혈류측정 시스템 설계 및 평가 (Design and Evaluation of Blood flow Measurement Using Self-mixing type Semiconductor Laser)

  • 김덕영;이진;김세동;고한우;김성환
    • 대한의용생체공학회:의공학회지
    • /
    • 제17권4호
    • /
    • pp.499-506
    • /
    • 1996
  • Blood flow velocimeter is an essential device to measure the blood flow in skin tissue. In this study, we developed a high-speed LDV(laser Doppler Velocimeter) that has real time processing capability using a DSP(digital signal processing) chip and is able to continuously measure information about blood-flow based on a noninvasive method using self-mixing type laser diode. This LDV system has a simpler structure than any other typical blood flow velocimeter and is composed of new self-mixing probe, stabilizer circuits DSP board, and interf'ace boule We measured velocity of speaker-unit by operational frequencies to identify Doppler effect of this system, performed clinical experiment on bare finger tip and compared it with a commercial euipment BPM403A(USA).

  • PDF

인체의 자세가 체온조절에 미치는 영향 (The effect of posture on the human thermoregulatory response)

  • 심현섭;최정화
    • 한국의류학회지
    • /
    • 제17권3호
    • /
    • pp.415-427
    • /
    • 1993
  • The purpose of this study was to evaluate the thermoregulatory responses to postures under different environmental conditions and to obtain the basal information for standard clothing weight, indoor climates, and working condition. Two adult female (22.5yrs, 46kg) were participated in this study. The experimental conditions were divided into three groups ; 1) comfort($27{\pm}1^{\circ}C$, $60{\pm}10%$), 2) hot($34{\pm}1^{\circ}C$, $60{\pm}10%$), and 3) cold($21{\pm}1^{\circ}C$, $50{\pm}10%$) condition. The postures performed were as follows; standing, sitting on the chair, sitting on the floor, and supine on the floor. At each condition, subjective sensations, 12 points skin temperature, rectal temperature, total and local sweat rate, pulse rates, blood pressure, skin blood flow rate were measured. The results were as follows : 1. Rectal temperature was high significant among groups in order of supine, sitting on the floor, sitting on the chair, standing posture(p<0.01). 2. Skin temperature was high in part of contact with the surface of the floor or wall and the effect of posture was greater in peripheral temperature than torso temperature. Sitting on the chair and sitting on the floor posture showed higher peripheral temperature than standing and supine posture. And peripheral temperature was lower in supine posture than any other postures. 3. Total and local sweat rate were decreased in order of standing, sitting on the chair, sitting on the floor, supine posture. 4. Pulse rate and disastolic blood pressure were higher in standing posture than supine posture, and there was significant difference between two postures(p<0.001). 5. Blood flow rate of thigh was high in sitting on the chair and sitting on the floor posture and low in standing posture. Blood flow rate of leg was low in standing posture significantly(p<0.01). 6. In comfort and hot condition, temperature sensation and comfort sensation were higher in standing posture and lower in supine posture than any other postures. In cold condition, temperature sensation was lower and comfort sensation was higher in standing and supine posture than any other postures. And supine posture was appeared positive in hot condition and negative in cold condition. From this study, we confirmed the effects of posture on human thermoregulatory responses. Results indicate that even under same conditions and clothing weight, the insulation of clothing will be different to postures.

  • PDF

원적외선 방사 기능 실내복 착용이 인체 피부혈류량, 온열 심리 및 온열 생리 기능에 미치는 영향 (Influences of Wearing Far-infrared Indoor Clothing on Skin Blood Flow, Perceptual and Thermal Responses)

  • 백윤정;서원지;김형찬;이주영
    • 한국의류학회지
    • /
    • 제44권2호
    • /
    • pp.342-353
    • /
    • 2020
  • The purpose of this study was to evaluate far-infrared clothing (FIR condition) with non-far-infrared clothing (Control condition) to assess the effects of FIR on thermo-physiological responses. Eight young healthy males (23.0±2.3 yr, 176.5±3.7 cm, and 69.0±4.3 kg) participated in this experimental trial, which consisted of a 20 min rest followed by a 40 min walk (4.0 km·hr-1) and a 20 min recovery at 20℃ with 50%RH. The results showed that finger skin blood flow and mean skin temperature were significantly higher for the FIR condition than the control during exercise and recovery (p<.001). Clothing microclimate temperature of the FIR condition was 0.5℃ higher on the back (p=.001) and 0.4℃ higher on the thigh (p=.015) during recovery. Clothing microclimate relative humidity of the FIR condition was 13% higher on the chest (p=.006) and 19% higher on the back (p<.001) during exercise than control. Subjects felt warmer and more comfortable in the FIR condition than in the control (p<.05). Perceived skin wettedness (%BSA) was less in the FIR condition than in the control (p=.001). These results indicate that ceramic-embedded clothing had significant effects on thermoregulatory responses for light activity in an indoor environment.