• Title/Summary/Keyword: size of pier

Search Result 62, Processing Time 0.024 seconds

Seismic fragility analysis of corroded RC pier strengthened by engineered cementitious composites

  • Yan Liang;Jing-Xiao Shu;Cheng-Xin Zhao;Xi Dong Wang;Guang Yu Yang
    • Earthquakes and Structures
    • /
    • v.26 no.4
    • /
    • pp.269-283
    • /
    • 2024
  • When a reinforced concrete (RC) structure is exposed to a corrosive environment for an extended period of time, the material qualities deteriorate, resulting in a loss in seismic performance. Engineered Cementitious Composites (ECC) have been used to reinforce the corroded RC structure, which can achieve reinforcement effectiveness for a small change in cross-section size. In this work, finite element models of unjacketed RC pier and ECC jacketed pier were established and verified by experimental tests, with the buckling effect of longitudinal reinforcement considered. Compared with the unjacketed pier, the displacement of the pier top of the ECC jacketed pier was reduced by about 9.52% under earthquake action. In the case of moderate and major earthquakes, the probability of exceedance of ECC jacketed pier is significantly reduced. For the case of rare earthquake loading, with the ECC jacket, the e of the pier experiencing serious damage and complete damage states is reduced by 10.29% and 29.78%, respectively.

Test for the influence of socket connection structure on the seismic performance of RC prefabricated bridge piers

  • Yan Han;Shicong Ding;Yuxiang Qin;Shilong Zhang
    • Earthquakes and Structures
    • /
    • v.25 no.2
    • /
    • pp.89-97
    • /
    • 2023
  • In order to obtain the impact of socket connection interface forms and socket gap sizes on the seismic performance of reinforced concrete (RC) socket prefabricated bridge piers, quasi-static tests for three socket prefabricated piers with different column-foundation connection interface forms and reserved socket gap sizes, as well as to the corresponding cast-in-situ reinforced concrete piers, were carried out. The influence of socket connection structure on various seismic performance indexes of socket prefabricated piers was studied by comparing and analyzing the hysteresis curve and skeleton curve obtained through the experiment. Results showed that the ultimate failure mode of the socket prefabricated pier with circumferential corrugated treatment at the connection interface was the closest to that of the monolithic pier, the maximum bearing capacity was slightly less than that of the cast-in-situ pier but larger than that of the socket pier with roughened connection interface, and the displacement ductility and accumulated energy consumption capacity were smaller than those of socket piers with roughened connection interface. The connection interface treatment form had less influence on the residual deformation of socket prefabricated bridge piers. With the increase in the reserved socket gap size between the precast pier column and the precast foundation, the bearing capacity of the prefabricated socket bridge pier component, as well as the ductility and residual displacement of the component, would be reduced and had unfavorable effect on the energy dissipation property of the bridge pier component.

Review of appropriateness of existing formula for estimating the depth of scour and the experimental study on development of the formula to estimated the depth of scour (기존 세굴심 산정식의 적정성 검토 및 세굴심 산정식 개발에 대한 실험적 연구세요)

  • Choi, Han-Kuy;Lee, Yeong-Seop
    • Journal of Industrial Technology
    • /
    • v.29 no.A
    • /
    • pp.67-75
    • /
    • 2009
  • In this study, the investigation of hydraulic characteristics and the pier data for the rivers in Youngseo area of Gangwon Province was carried out and the evaluation and comparison between the values from existing formulas and the values from the model tests was conducted, along with the statistical sensitivity analysis of the elements influencing the scour. As a result, the deviation between the values calculated from the existing formulas and the model tests appeared to be 1.09%~63.98% as the piers were getting larger, which indicated that the existing formulas were not appropriate to estimate the scour in the rivers in Gangwon area. And the formula which estimates the scour with the size of the pier only, among the existing ones, was far behind in estimating the sensitivity because of insufficient incorporation of the hydraulic characteristics, though it is convenient to estimate the value. The sensitivity analysis of the value from the model tests and the depth of the scour proved the significant impact on scour by the size of the pier and water depth, indicating 64% and 36%, respectively. In this study, the formula developed through the regression analysis performed based on the values from the model tests, which appeared to be appropriate for the rivers in Gangwon Province, was proposed.

  • PDF

Parameter identification for nonlinear behavior of RC bridge piers using sequential modified extended Kalman filter

  • Lee, Kyoung Jae;Yun, Chung Bang
    • Smart Structures and Systems
    • /
    • v.4 no.3
    • /
    • pp.319-342
    • /
    • 2008
  • Identification of the nonlinear hysteretic behavior of a reinforced concrete (RC) bridge pier subjected to earthquake loads is carried out based on acceleration measurements of the earthquake motion and bridge responses. The modified Takeda model is used to describe the hysteretic behavior of the RC pier with a small number of parameters, in which the nonlinear behavior is described in logical forms rather than analytical expressions. Hence, the modified extended Kalman filter is employed to construct the state transition matrix using a finite difference scheme. The sequential modified extended Kalman filter algorithm is proposed to identify the unknown parameters and the state vector separately in two steps, so that the size of the problem for each identification procedure may be reduced and possible numerical problems may be avoided. Mode superposition with a modal sorting technique is also proposed to reduce the size of the identification problem for the nonlinear dynamic system with multi-degrees of freedom. Example analysis is carried out for a continuous bridge with a RC pier subjected to earthquake loads in the longitudinal and transverse directions.

Effect of the curved vane on the hydraulic response of the bridge pier

  • Qasim, Rafi M.;Jabbar, Tahseen A.;Faisa, Safaa H.
    • Ocean Systems Engineering
    • /
    • v.12 no.3
    • /
    • pp.335-358
    • /
    • 2022
  • Hydrodynamic field alteration around a cylindrical pier using a curved vane is numerically investigated. The curved vane with various angles ranged from 10 to 220 degree is placed at the upstream of the cylindrical pier. Laminar flow is adopted in order to perform the steady-state analysis. It is found that the flow separation leads to the formation of four bubbles depending on the value of the curved vane angle. Two bubbles are located in the region between the rear of the curved vane and the leading surface of the cylindrical pier, while the remaining two bubbles are located at the wake zone behind the cylindrical pier. Numerical analysis is performed to reveal the hydrodynamic field and influence of curved vane on the formation and evolution of the bubbles. It is found that the center and size of the bubble depend mainly on the value of the curved vane angle. It is observed that the flow velocity vector shows clearly the alteration in the flow velocity direction especially at the leading surface and rear surface of the curved vane owing to the occurrence of flow separation and flow dissipation along the circumference of the vane.

A Study on the Longitudinal Behavior of 2-Span Continuous Railway Bridge (2경간 연속 철도교의 종방향 거동에 관한 연구)

  • Im, Jung-Soon;Jo, Jae-Byung;Bahng, Yun-Suk
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.1 no.1 s.1
    • /
    • pp.81-90
    • /
    • 2001
  • This paper presents the results of the parametric study on the longitudinal behavior of 2-span continuous railway bridge. To perform the main objective of this paper, the effects of pier shaft stiffness, pier height, the size of pier foundation, and the bearing stiffness on the longitudinal behavior of the bridges are studied. Within the limits of this study, the research result has revealed that the variation of the fixed pier is more effective than that of the moved pier. In addition, the control of the hearing stiffness is much less expensive than that of any other parameters.

  • PDF

A Study on the River-Bed Scouring by the Pier (교각에 의한 하상선굴에 관한 실험적 연구)

  • 정준석;임국창
    • Water for future
    • /
    • v.6 no.1
    • /
    • pp.19-28
    • /
    • 1973
  • Presented is the results of a model study about scouring around a bridge pier. 24 different types of piers were inestigated for the depth and width of scouring. The grain size of sand used in the experiment ranges from 0.149 to 2, 380mm, The time required to reach the stable bed formation was about 30min, with the range of Froud number from 0.58 to 0.69. It has been found that the scouring is most severe at the frontal side of the pier and decreases with decreasing a contact angle (between the center line of the pier and tangent to the frontal face). For design purposes, it is recomanded that the contact angle at the frontal face is 25 degrees for a triangular type and 40 deyrees for a circular type respectively.

  • PDF

A Experimental Study on the Depth of Scour to Formula Estimated of the Pattern Pier (원형 교각의 세굴심 산정식 개발에 대한 실험적 연구)

  • Baek, Kyung-Won;Park, Soo-Jin;Lee, Yeong-Seop;Choi, Han-Kuy
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.10 no.2
    • /
    • pp.83-90
    • /
    • 2010
  • This study was intended to compare and evaluate the value obtained from the existing formula for calculating the depth of scour and the valey from experimental model through the investigation of hydraulic characteristics and pier data in the area of rivers at Gangwon Province, and the sensitivity analysis, which is a statistical method, of the elements affecting the scour of the pier was carried out. As a result, a deviation between the values of existing formulas and experimental model reached about 1.09%$^{\circ}$63.98%, indicating that existing formula was found not to be appropriate at the rivers in Gangwon Province. A sensitivity analysis was carried out based on value obtained from experimental model and consequently, the elements affecting the scour were size of pier accounting for 64% and water depth accounting for 36%. Finally, a formula for calculating the scour of the pattern piers at the rivers in Gangwon Province was developed using the regression analysis.

An Experimental Study on Reduction Effect of Scour Depth arounding Uniform Cylindrical Pier with Various Size of Circular Collar (원환 크기의 변화에 따른 균등원통교각 주위의 세굴심 감소효과에 관한 실험적 연구)

  • Sim, Ou-Bae;Song, Jai-Woo
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.3 no.2 s.9
    • /
    • pp.139-145
    • /
    • 2003
  • This study is to propose reduction effect of scour depth and a optimum size of circular collar through experimental analyses with various collar sizes. To do so, we carried out hydraulic model experiments. In the case of with considering the collar, the effect of reduction of scour depth increased according to the increase of collar size. When size of collar is 2 as the ratio of collar diameter(W) to pier diameter(D), scour depth is decreased about 67% and deposition height is increased about 70%. The optimal size of collar proposed in this study is W/D=2 by analyzing reduction effect of scour depth, size of scour hole, and deposition height.

Experimental Estimation of Shear Stresses at Pier-Front (교각전면부 하상재료의 입도분포에 따른 전단응력 산정에 관한 실험적 연구)

  • Park, Yoon Sung;Kang, Jun Ku;Yeo, Woon Kwang
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2004.05b
    • /
    • pp.429-433
    • /
    • 2004
  • According to researchers, the influential factors of scouring are generally divided into three factors: the flow conditions, the type and position of structures, and the characteristics of bed materials. In addition, scouring is affected by the 3-dimensional turbulent boundaries, the unsteady flow, the movement of sediment in the scour-hole area, the approach flow velocity and depth, the width of bridge foundation/pier, and the particle size of bed materials. However, it is difficult to estimate the scour depth near bridge piers when all conditions are factored in at once. Therefore, for reasonably accurate estimates of scour depth, it is essential to consider sufficiently the flow force and resisting force for scour. That is, to determine the shear stress concerning the bed material distribution is needed. In this study, the experiments were performed under the condition of a steady state of flow. As a result, scouring occurred at velocity ratios of 0.476,$(V/V_c=0.476)$, and the scour depth was increased linearly as the velocity ratio increased. in addition, the average values of shear stress ratio at zero scouring depth in both rectangular and circular piers were approximately 7$(\tau_c/\tau_{approach})$ and in the case for same size bed particle material. The results of this study can be used for the fundamental material for estimating the scour depth of bed materials.

  • PDF