• 제목/요약/키워드: size of dust

검색결과 472건 처리시간 0.024초

토공사 현장에서 발생하는 공기 중 석영의 노출 평가 (Exposure Assessment of Airborne Quartz from Earthwork Sites)

  • 성은창;배혜정;정종현;피영규
    • 한국산업보건학회지
    • /
    • 제25권4호
    • /
    • pp.584-590
    • /
    • 2015
  • Objectives: The purpose of this study was to evaluate quartz concentrations in airborne total and respirable dusts. Materials: Respirable dust samples were collected using a 10 mm aluminum cyclone equipped with a 37 mm$5{\mu}m$ pore size PVC filter. Total dust samples were collected with a three stage cassette from three work sections at earthwork sites located in the South Chungcheong-do Province area. Results: The geometric means of quartz concentrations were $0.008mg/m^3$ and $0.004mg/m^3$ in total dust and respirable dust, respectively. The geometric means of quartz contents analyzed by FTIR were 3.74% in total dust and 3.16% in respirable dust. The geometric mean of quartz concentrations and contents in secondary blasting operations were higher than those in other operations. Conclusions: Given that secondary blasting operations had higher quartz concentrations, there is a need to reduce respirable dust, such as through wet operations.

미세먼지(PM10)와 초미세먼지(PM2.1)의 농도와 폐포 침착율 조사 (Investigation of the Concentration of PM2.1 & PM10 and Alveolar Deposition Ratio)

  • 김성천
    • 한국환경보건학회지
    • /
    • 제45권2호
    • /
    • pp.126-133
    • /
    • 2019
  • Objectives: In this study, a nine-stage cascade impactor was used to collect dust, and the concentration of $PM_{2.1}$ & $PM_{10}$ and alveolar deposition ratio were investigated. Methods: This study was conducted at Kunsan National University from May to June 2016. A nine-stage Cascade Impactor was used to analyze the concentrations of fine and ultrafine dust and to estimate the alveolar deposition rate by particle size of atmospheric dust particles. The pore size of each stage of the collector used in this study gradually increased from F to 0, with the F-stage as the last stage. Results: The mass fraction of PM showed a bimodal distribution divided into $PM_{2.1}$ & $PM_{10}$ based on $2.1-3.1{\mu}m$. The average mass fraction of particulate matter in the range of $2.1-3.1{\mu}m$ was 44%, and the area occupied by $PM_{2.1}$ was similar. Therefore, the Gunsan area is considered to be a region where there are similar effects from anthropogenic and natural sources. Conclusion: Dust collecting efficiency increased with the stage of collecting fine dust, and the efficiency of collection was very low at the stage of collecting ultra-fine dust. The seasonal overall efficiency of the Cascade Impactor was 44% in spring and 37.4% in summer, and the average overall efficiency was 40.7%. The alveolar deposition rate of $PM_{2.1}/PM_{10}$ during the sampling period was estimated to be about 75% deposited in the alveoli.

광산란방식을 이용한 미세먼지 실시간 모니터링 장치 개발 및 성능평가 (Development and Performance Evaluation of a Real-time PM Monitor based on Optical Scattering Method)

  • 강두수;오정은;이상열;신희준;봉하경;김대성
    • 한국입자에어로졸학회지
    • /
    • 제14권4호
    • /
    • pp.107-119
    • /
    • 2018
  • In this study, we have developed a real-time monitoring device for measuring PM10 and PM2.5 of ambient aerosol particles. The real-time PM monitor (SENTRY Dust Monitor) uses the optical scattering method and has 16 channels in particle size. The laboratory and field tests were carried out to evaluate the developed SENTRY Dust Monitor. Arizona Test Dust particles were used as test particles in the laboratory test and the field test was carried out at the Jongno-gu Observatory in Seoul. The measurements of PM10 and PM2.5 concentrations obtained by SENTTRY Dust Monitor were compared with Grimm Dust Monitor (Model 1.108) and a beta ray gauge. It was shown that the PM10 and PM2.5 concentrations obtained by SENTRY Dust Monitor agree well with that of the reference devices. Based on the results obtained in this study, it could be concluded that the SENTRY Dust Monitor can be used as a PM monitoring device for real-time monitoring of the ambient aerosols.

Preparation of Spherical Granules of Dolomite Kiln Dust as Gas Adsorbent

  • Choi, Young-Hoon;Huh, Jae-Hoon;Lee, Shin-Haeng;Han, Choon;Ahn, Ji-Whan
    • 한국세라믹학회지
    • /
    • 제53권1호
    • /
    • pp.13-17
    • /
    • 2016
  • It is highlighted that increasing the adsorbent surface area on volumetric basis is very important in providing an easy access for gas molecules. Fine particles around $3{\mu}m$ of soft-burned dolomite kiln dust (SB-DKD) were hydrated to wet slurry samples by ball mill process and then placed in a chamber to use spray dryer method. Spherical granules with particle size distribution of $50{\sim}60{\mu}m$ were prepared under the experimental condition with or without addition of a pore-forming agent. The relationship between bead size of the pore-forming agent and size of SB-DKD particles is the most significant factor in preparation of spherical granules with a high porosity. Whereas addition of smaller beads than SB-DKD resulted in almost no change in the surface porosity of spherical granules, addition of larger beads than SB-DKD contributed to obtaining of the particles with both 15 times larger average pore volume and 1 order of magnitude larger porosity. It is considered that spherical granules with improved $N_2$ gas adsorption ability may also be utilized for other atmospheric gas adsorption.

발파해체현장에서 발생하는 순간분진의 입경분포 특성 (Characteristics of Particle Size Distributions Generated in the Vicinity of Building Blasting Demolition Sites)

  • 이경희;김효진;박찬규;고광백
    • 한국환경과학회지
    • /
    • 제18권1호
    • /
    • pp.41-47
    • /
    • 2009
  • In building demolition work, major dust-generating activities are blasting concrete and rock. The aim of this study was to find the characteristic of particle size of dusts which were generated during building demolition work using explosion. The DustMate of the Turnkey-Instruments Ltd. was used for particulate size-selective sampling of the four sites. TSP(Total Suspended Particle), PM10(Particle Matter $10{\mu}m$), PM2.5(Particle Matter $2.5{\mu}m$), and PM1.0(Particle Matter $1.0{\mu}m$) were measured during building demolition work using explosion. The large particulate (higher than the diameter $10{\mu}m$) showed to be higher than 50%. The particulate ranged from $10{\mu}m\;to\;2.5{\mu}m$ showed about 30-40%. PM2.5 was not scarcely detected in the samples collected for building demolition work using explosion. We conclude that the dust generated during building demolition work using explosion has not most respirable particulate.

회귀분석에 의한 공기중 인조광물 섬유 허용기준과 부합하는 총분진 농도의 추정 (Estimation of Total Dust Concentration Complying with the TLV of Airborne Man-made Mineral Fibers by Regression Analysis)

  • 신용철;이광용
    • 한국산업보건학회지
    • /
    • 제9권2호
    • /
    • pp.158-166
    • /
    • 1999
  • The purpose of this study was to investigate the correlation between airborne total dust and man-made mineral fibers (MMMF), and to estimate total dust concentration to maintain below the American Conference of Governmental Industrial Hygienists (ACGIH) Threshold Limit Value (TLV$^{(R)}$) for the MMMF. The regression coefficients between airborne total dust concentrations and fiber concentrations determined in the industries producing glass fibers, rock wool. refractory ceramic and continuous filament glass fibers products were 0.41, 0.42, 0.20 and 0.19, respectively. The size characteristics of fibers as well as the amounts of contaminated non-fibrous dusts could affect the correlation intensities. When total dust and fiber exposure data were compared with the occupational exposure limits, there was a large gap between two evaluation results. The regression coefficient between total dust and fiber data was increased ($r^2=0.88$) in the process of insulation installation generating in the higher levels of glass or rock wool fibers. In this case, an estimated total dust concentration of glass wool or rock wool fibers complying with the ACGIH TLV (1 f/cc) was $1.7mg/m^3$. In conclusion, the total dust and fibers concentrations was highly correlated at the higher exposure levels so that total dust-monitoring data could be used to control simply and economically and to estimate worker's exposure to fibers.

  • PDF

항공기 기내 청소노동자의 분진, 초미세먼지(PM2.5) 및 블랙카본 노출수준 평가 (Exposure Assessment of Dust, Ultra Fine Dust(Particulate Matter 2.5, PM2.5) and Black Carbon among Aircraft Cabin Cleaners)

  • 박현희;김세동;김성호;박승현
    • 한국산업보건학회지
    • /
    • 제33권2호
    • /
    • pp.171-187
    • /
    • 2023
  • Objectives: Aircraft cabin cleaning work is characterized by being performed within a limited time in a narrow and enclosed space. The objective of this study was to evaluate the exposure levels to dust, ultra fine dust(PM2.5) and black carbon(BC) among aircraft cabin cleaners. Methods: Active personal air sampling for respirable dust(n=73) and BC(n=47) was conducted during quick transit cleaning(cabin general and vacuum-specific) and seat cover replacement and total dust and PM2.5 were area-air-sampled as well. Also, size distribution of particle was identified with the cleaning workers targeted. Dusts were collected with PVC filters using gravimetric analysis. The concentration of PM2.5 and the particle size distribution were measured with real-time direct reading portable equipment using light scattering analysis. The concentration of BC was measured by aethalometer(filter-based real-time light absorption analysis instrument). Results: The geometric mean of respirable dust was the highest at vacuum cleaning as 74.4 ㎍/m3, following by replacing seat covers as 49.3 ㎍/m3 and cabin general cleaning as 47.8 ㎍/m3 . The arithmetic mean of PM2.5 was 4.83 ~ 9.89 ㎍/m3 inside the cabin, and 28.5~44.5 ㎍/m3 outside the cabin(from bus and outdoor waiting space). From size distribution, PM2.5/PM10 ratio was 0.54 at quick transit cleaning and 0.41 at replacing seat covers. The average concentration of BC was 2~7 ㎍/m3, showing a high correlation with the PM2.5 concentration. Conclusions: The hazards concentration levels of aircraft cabin cleaners were very similar to those of roadside outdoor workers. As the main source of pollution is estimated to be diesel vehicles operating at airports, and it is necessary to replace older vehicles, strengthen pollutant emission control regulations, and introduce electric vehicles. In addition, it is necessary to provide as part of airport-inftastructure a stable standby waiting space for aircraft cabin cleaners and introduce a systematic safety and health management system for all workers in the aviation industry.

직접필터법을 이용한 석영 분석시 고령석의 영향 및 보정방법 평가 (The evaluation of correction methods and effect of kaolinite on quantitative analysis of quartz in respirable dust by FTIR direct-on-filter method)

  • 피영규
    • 한국산업보건학회지
    • /
    • 제19권1호
    • /
    • pp.1-7
    • /
    • 2009
  • To establish the Fourier-Transform Infra-Red spectrophotometry(FTIR) Direct-On-Filter(DOF) technique as a useful analytical method for quartz in respirable dust samples, an influence of the kaolinite should be corrected. Respirable dust, created in a dust chamber containing the standard material of quartz and kaolinite were collected using a cyclone equipped with a 25 mm, $0.8\;{\mu}m$ pore size DM filter as a collection medium. This study was designed to compare three methods of correction for kaolinite when quantifying the content of quartz, including the least square, the optimum choice and the spectral subtraction methods. The content of quartz in the respirable dust samples was overestimated by 6.2% when mixed with kaolinite(35.5% by weight). The content of quartz containing kaolinite(72.8% by weight) were overestimated by 32%. The spectral subtraction method underestimated the quartz content by 1.5%, while the other two correction methods, the optimum choice and the least square method, overestimated the quartz content by 1.9% to 6.4% and 0.04 to 1.1%, respectively. The results of this study are suggested that, when correcting for effects of kaolinite on quantitative analysis of quartz in respirable dust by FTIR direct-on-filter method, the least square method produce the most unbiased results be compared with those of other correction methods.

식품분진의 폭발 특성과 발화온도에 관한 연구 (A study on the explosion properties and Autoignition Temperature of a food additive Dusts)

  • 안형환
    • 대한안전경영과학회:학술대회논문집
    • /
    • 대한안전경영과학회 2001년도 춘계학술대회
    • /
    • pp.301-310
    • /
    • 2001
  • A study for the dangerous properties measurment of dust explosion was attended by the various dust concentration on Anthraquinone, Sodiumbenzoic acid, Corn starch, soy sauce powder, and cheese powder. As the result, maximum explosion pressure, the maximum rate of pressure rise, autoigntion temperature, and the water content of dust on lower limit explosion concentration was obtained as follows 1. The lower limit explosion concentration on soy sauce powder with the humidity of 65 to 90% increased by increasing the con tent of moisture, and the effect of dry air and moisture air decreased better in make of dry air. 2. The effect of a various dust concentration on autoigntion temperatures is investigated, If the vessel of dust explosion is small size and the easiness of autoignition was controled by air within the vessel, because it was better decreased air with increasing of dust concentration 3. The maximum explosion pressures of Anthraguinone, sodiumbenzoic acid, com starch, soy sauce powder, and cheese powder were 1.0g/$\ell$, 1.0g/$\ell$, 1.5g/$\ell$, 1.5g/$\ell$, and 1.5g/$\ell$, respectively, and the maximum rate of pressure rise were 0.5g/$\ell$, 0.5g/$\ell$, 1.0g/$\ell$, 1.0g/$\ell$, and 1.0g/$\ell$, respectively.

  • PDF

난류형 클린룸내의 Layout 변화에 따른 분진제거 특성에 관한 연구 (A Study on the Phenomena of Dust Removal by the Layout Changes in the Turbulent Type Clean Room)

  • 김연희
    • 건설안전기술
    • /
    • 통권41호
    • /
    • pp.80-87
    • /
    • 2007
  • The purpose of this paper is to investigate the removal efficiency of fine dusts as the configuration condition of machinery and equipments in Clean Room and to analyze the flowing behaviors of fine dusts as the layout of Clean Room. The layout of the Clean Room was classified into side layout type, 2 center line type and center concentration type layout, and the flow rates used in this research were 0.22m/s, 0.44m/s and0.80m/s. Dust removal efficiency as layout change was decreased 37% for side layout type, 31% for 2 centerline type and 20% for center concentration type layout at the flow rate of 0.22m/s, compared with the state without machinery and equipments in Clean Room. The efficiency was decreased 42% for side layout type,22% for 2 center line type and 8% for center concentration type layout at the flow rate of 0.44m/s, and decreased 20% for side layout type, 18% for 2 center line type and 10% for center concentration type layout at the flow rate of 0.80m/s. According to the result of dust removal behavior, $0.3\mum$, $1\mum$and $3\mum$dust except for $5\mum$showed the higher change of the behavior in side layout type than in center concentration type layout due to the change of air flow. It was confirmed that removal behavior depends on the layout of machinery and equipments as the dust size decreases.

  • PDF