• Title/Summary/Keyword: size guide

Search Result 355, Processing Time 0.028 seconds

Comparison of accuracy between free-hand and surgical guide implant placement among experienced and non-experienced dental implant practitioners: an in vitro study

  • Dler Raouf Hama;Bayad Jaza Mahmood
    • Journal of Periodontal and Implant Science
    • /
    • v.53 no.5
    • /
    • pp.388-401
    • /
    • 2023
  • Purpose: This study investigated the accuracy of free-hand implant surgery performed by an experienced operator compared to static guided implant surgery performed by an inexperienced operator on an anterior maxillary dental model arch. Methods: A maxillary dental model with missing teeth (No. 11, 22, and 23) was used for this in vitro study. An intraoral scan was performed on the model, with the resulting digital impression exported as a stereolithography file. Next, a cone-beam computed tomography (CBCT) scan was performed, with the resulting image exported as a Digital Imaging and Communications in Medicine file. Both files were imported into the RealGUIDE 5.0 dental implant planning software. Active Bio implants were selected to place into the model. A single stereolithographic 3-dimensional surgical guide was printed for all cases. Ten clinicians, divided into 2 groups, placed a total of 60 implants in 20 acrylic resin maxillary models. Due to the small sample size, the Mann-Whitney test was used to analyze mean values in the 2 groups. Statistical analyses were performed using SAS version 9.4. Results: The accuracy of implant placement using a surgical guide was significantly higher than that of free-hand implantation. The mean difference between the planned and actual implant positions at the apex was 0.68 mm for the experienced group using the free-hand technique and 0.14 mm for the non-experienced group using the surgical guide technique (P=0.019). At the top of the implant, the mean difference was 1.04 mm for the experienced group using the free-hand technique and 0.52 mm for the non-experienced group using the surgical guide technique (P=0.044). Conclusions: The data from this study will provide valuable insights for future studies, since in vitro studies should be conducted extensively in advance of retrospective or prospective studies to avoid burdening patients unnecessarily.

PET Detector Design with a Small Number of Photo Sensors (적은 수의 광센서를 사용한 PET 검출기 설계)

  • Lee, Seung-Jae;Baek, Cheol-Ha
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.4
    • /
    • pp.525-531
    • /
    • 2021
  • The detector of the positron emission tomography (PET) is composed using a plurality of scintillation pixels and photo sensors. The use of multiple photo sensors increases cost and complicates signal processing. In this study, a detector with reduced cost and simple signal processing was designed using a small number of photo sensors. A scintillation pixel and a small number of photo sensors were used, and a optical guide was used to deliver light to all the photo sensors. A reflector is applied to the scintillation pixel and the optical guide to transmit the maximum amount of light to the photo sensor. A diffuse reflector and a specular reflector were used for the reflector, and a flood image was obtained by applying different thicknesses of the optical guide. An optimal combination was selected through comparative analysis of the acquired flood images. As a result, when specular reflectors were used for both the scintillation pixel and the optical guide, excellent flood images were obtained from optical guides of all thicknesses. For the optical guide, the optimal image was obtained when using a 3 mm thickness in consideration of the size of the image and the analysis of the point where the image of the scintillation pixel was formed.

Image Acquisition Study of Maximal Scintillation Pixel Array using Light Guide (광가이드를 사용한 최대 섬광 픽셀 배열의 영상 획득 연구)

  • Lee, Seung-Jae
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.3
    • /
    • pp.249-255
    • /
    • 2022
  • Positron emission tomography for small animals has very high spatial resolution for imaging very small organs. To achieve good spatial resolution, the system must be constructed using very small scintillation pixels. When a detector is constructed using very small scintillation pixels, the size of the applicable array varies depending on the photosensor pixel. In a previous study, a study was conducted to find the maximum scintillation pixel arrangement according to the size of the photosensor. In this study, a detector with a light guide was designed to configure the detector using a more extended array of scintillation pixels, and try to find the maximum arrangement in which all scintillation pixels are imaged. The detector was designed using DETECT2000, which can simulate a detector made of a scintillator. Simulations were performed by configuring the detectors from an 11 × 11 scintillation pixel array to a 16 × 16 array. After obtaining a flood image by collecting the light generated from the scintillation pixel with a photosensor, the largest arrangement without overlap was found through image analysis. As a result, the largest arrangement in which all scintillation pixels could be distinguished without overlapping was a 15 × 15 arrangement.

Secondary Flow Characteristics in a Liquid Ramjet Combustor Using Stereoscopic PIV (Stereoscopic PIV 속도장 측정기법을 이용한 액체 램제트 연소기에서의 2차 재순환 유동장 특성)

  • Kim S. J.;Sohn C. H.
    • Journal of the Korean Society of Visualization
    • /
    • v.3 no.1
    • /
    • pp.58-62
    • /
    • 2005
  • Flow characteristics at secondary recirculation zone in a liquid fuel ramjet combustor were investigated using CFD and Stereoscopic PIV method. The combustors have two rectangular inlets that form 90 degree each other. Three guide vanes were installed in each rectangular inlet to improve the flow stability. The tested angle of the air intakes was 60 degree. The experiments were performed in the water tunnel test with the same Reynolds number in the case of Mach 0.3 at inlet. The computational and experimental results showed that the secondary recirculation flow occurred at the front junction of inlet main stream and combustor chamber. The size of secondary recirculation regions are increased with approaching closer to the center of the combustor. Since the performance of combustor is closely dependent not only on the main recirculation in the dome region but also on the secondary recirculation flow in a junction region, the optimal angle of the air intakes should be considered the recirculation size as frame holder.

  • PDF

Flow Characteristics of secondary recirculation region for using Stereoscopic PIV in a Liquid Fuel Ramjet Combustor (Stereoscopic PIV 속도장 측정기법을 이용한 액체 램제트 연소기에서의 2차 재순환 유동장 측정)

  • Kim S. J.;Choi J. H.;Park C. W.;Sohn C. h.
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2003.11a
    • /
    • pp.115-120
    • /
    • 2003
  • Flow characteristics at secondary recirculation zone in a liquid fuel ramjet combustor are investigated using CFD and 3-D Stereoscopic PIV method. The combustors have two rectangular inlets that form 90 degree each other. Three guide vanes were installed in each rectangular inlet to improve the flow stability. The tested angle of the air intakes was 60 degree. The experiments were performed in the water tunnel test with the same Reynolds number in the case of Mach0.3 at inlet. Both computational and experimental results showed the secondary recirculation flow occurred at the front junction of inlet main stream and combustor chamber. The size of secondary recirculation region increased with upon closer center of axial combustor. Since the performance of combustor depends on not only the main recirculation in the dome region but also the secondary recirculation flow in a junction region, the optimal angle of the air intakes should consider the recirculation size as frame holder.

  • PDF

Evaluation of Correlation between Aggregate Gradation and Dynamic Modulus with Statistical Analysis (통계분석을 통한 골재입도와 동탄성계수 상관도 평가)

  • Lee, Kwan-Ho;Cho, Kyung-Rae;Lee, Byung-Sik
    • International Journal of Highway Engineering
    • /
    • v.10 no.3
    • /
    • pp.11-18
    • /
    • 2008
  • In recent, lots of researches for mechanical-empirical design concept for asphalt pavement are on going. AASHTO 2002 Design Guide in USA and KPRP(Korean Pavement Research Program) in Korea are under developing. In these programs, the mechanical properties of hot mix asphalt are a key role for design and analysis. Unfortunately, there is no proper database on the mechanical properties of hot mix asphalt, such as dynamic modulus. The use of dynamic modulus has couple of good advantages which is based on temperature, traffic loading and frequency on pavement. In this research, the verification of the relationship between maximum nominal aggregate size and dynamic modulus has been carried out. Also, test specimen size effect on dynamic modulus has been conducted. Considering the limitation of laboratory testing machine in Korea, test specimen with 100mm diameter and 150mm height is recommended for dynamic modulus test. Also, as the maximum nominal aggregate size increases, the dynamic modulus of hot mix asphalt increases.

  • PDF

LCD backlighting system with high luminance and good uniformity (LCD backlight unit의 고분자 산란형 도광판에 관한 연구)

  • Jung, Il-Yong;Park, Woo-Sang
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.04a
    • /
    • pp.173-176
    • /
    • 2000
  • we analyzed multiple ray tracing in the highly scattering optical transmission(HSOT) polymer plate by means of the Monte carlo simulation. Light transmission behavior in the light guide was simulated by a 3-dimensional ray tracing program considering scattering angle given by the Mie theory and mean free path. To improve the uniformity of the conventional HSOT backlight unit, We employed additionally dot patterns. For the proposed structure, we calculated the light transmission behavior and obtained a bright and uniform backlight unit for a large size LCD panel of more than 12 inch.

  • PDF

Clinical Study of Dysphagia in Stroke Patients (1) (Preliminary paper) (뇌졸중환자의 연하장애에 관한 임상적 연구 (1))

  • Ko, Seong-Gyu
    • The Journal of Internal Korean Medicine
    • /
    • v.18 no.1
    • /
    • pp.62-68
    • /
    • 1997
  • Dysphagia generally has a good prognosis after stroke involving cerebral hemisphere or braibstem, but it could have serious consquence with dehydration leading to haemoconcentration, renal failure and aspiration leading to pneumonia. This preliminary report was written for main report. The main report will be written to give an objective guide post of management and treatment in stroke patient with dysphagia. The objective guide posts were follows as, 1. Close examination for relationship between dysphagia in stroke patients and other neurological deficits 2. Influence on the prognosis of dysphagia in stroke patients by the grade of dysphagia at admission time. 3. The realtionship between the site and size of brain damage and the grade and prognosis of dysphagia 4. The frequency and prognosis of dysphagia in stroke patients according to sex and age. 5. The rate and speed of recovery with dysphagia after stroke. 6. Frequency and process of complications, aspiration pneumonia, weight loss, sore, in stroke patient group with dysphagia.

  • PDF

A Study on Cutting Mechanism and Wear Character for BTA Drill (BTA드릴의 절삭 기구와 마모 특성에 관한 연구)

  • 장성규;전언찬
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.105-108
    • /
    • 1995
  • So far,in deep drilling process there are several manufacturing problems such as hole deviation, hole over size, circularity,straightness and surface roughness. Whit regard to these problems, we atudied the abrasion process on carbided tip of BTA drill and got the follow test results through the abrasion characteristic test and analysis on cutting mechanism for the drill tooth and guide pad. 1) In SM55C drilling process, the most stable and reasonable drilling speed range for optmum abrasion characteristic of drill tooth was 60m.min. 2) The total drilling torque was about 60kg .deg.cm on condition drilling speed 60m/min and 0.15mm/rev. These results show that the theoretical burnising torque is well accord with the tested torque which is working on guide pad.

  • PDF

Novel Optical Design of Light-Guide Plates for Transflective Liquid Crystal Displays.

  • Park, Won-Sang;Park, Kwang-Il;Han, Kwan-Young;Yoon, Tae-Hoon;Kim, Jae-Chang
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2002.08a
    • /
    • pp.880-882
    • /
    • 2002
  • We have proposed a novel optical design technique of light-guide plates(LGPs) which can able to improve the optical efficiency of transflective LCDs. The basic concepts of our design technique are that we make the groove-pattern of LGP pixels resemble the pixel-array-pattern of transflective LCDs in shape and size and make the surface of the groove scatter (front scattering). In simulated and measured results, we ensure that our design of LGP in backlight unit for transflective LCDs can improve the optical efficiency of LCDs.

  • PDF