• Title/Summary/Keyword: siphon

Search Result 87, Processing Time 0.024 seconds

Water Quality Improvement Using Inverted Siphon Curved Channel System of Serial Contact Materials (연속접촉재 역사이폰 만곡수로 시스템의 수질개선)

  • Lee, Jong-Seok;Lee, Seung-Young
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.6B
    • /
    • pp.541-550
    • /
    • 2011
  • This study sets the goal to improve effectively water quality of stream by complementing the weak points of the gravel contact oxidation process to use the inverted siphon curved channel system in free overfall of serial contact materials. The size of the current system can be diminished by expanding contact time, and the materials' replacement can be made easier when their gap are closed through the filtering boxes of contact materials. This system also has been developed into a construction method in which mixed and serial contact materials can be employed by using just the conventional single contact materials. It was verified the improvement ability of water quality of this system, during the simulation test at Tandong stream in Daejeon. The results of the verification of water quality improvement through several experiments in field were measured as follows : it showed to reduce about the averaged 55~83% higher than 60~75%, the internal planned goal of water quality improvement facilities.

Analysis on Flood Control Effect of Siphon Spillway by Reservoir Routing (저수지 추적을 통한 사이펀 여수로의 홍수조절 효과 분석)

  • Ko, Suhyeon;Kim, Jaeyoung;Lee, Giha
    • Journal of the Korean GEO-environmental Society
    • /
    • v.14 no.11
    • /
    • pp.55-63
    • /
    • 2013
  • Agricultural small dam reservoirs in Korea are vulnerable to flooding because of insufficient flood control capacity and deterioration such that reservoir water level is likely to rise rapidly and a large amount of water release quickly to downstream without flood warning. In this study, we performed hydrologic analysis to estimate design flood(200 years return period ${\times}1.2$) and also evaluated the effect of siphon spillway as a structural countermeasure for flood control and mitigation by applying reservoir routing to the Jipyeong reservoir, located in Sangju, Korea. The results show that the design flood was calculated at $284.3m^3/s$, and water level and water release decreased by 40cm and $91m^3/s$, respectively.

Experimental Characteristic of Drain Control to Cherepnov Water Lifter (Cherepnov 송수기에 대한 배수제어방식의 실험적 특성)

  • 박성천;이강일
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.39 no.6
    • /
    • pp.67-79
    • /
    • 1997
  • The perpose of this study was to suggest the experimental characteristic of the Cherepnov Water Lifter following the drain mode. The Cherepnov Water Lifter(CWL), which is powered by the potential energy of water, can be set to operate automatically when the water m a tank is drained. In this study, a CWL is constructed in the valve drain controlling mode(VCM) and the siphon drain controlling mode(SCM), and a pressure transducer is installed. It was found that, in the VCM, intake flow volume is proportional to both delivery flow volume and drain flow volume. In the SCM, intake flow volume is proportional to drain flow volume, and the average delivery rate is proportional to both efficiency and the water utilization ratio. Also, in the VCM, the water utilization ratio is 35~49%, efficiency is 62~9O%, average delivery rate is 12.8~81.2$cm^3$/s, and the average drain rate is 14.O~91.5c$cm^3$/s. On the contrary in the SCM, the water utilization ratio is 1.7~38%, efficiency is 3~58%, average delivery rate is 3.1 ~69.2$cm^3$/s, and the average drain rate is shown as 114.5~ 183$cm^3$/s. As a result of the water utilization ratio, efficiency, average delivery rate, and average drain rate are compared, the VCM is found to be superior and the more economical mode. However, the VCM requires manpower and electricity to operate the electronic machinery involved, while the SCM requires no manpower or electricity at all. An economic evaluation of these differences will be necessary in the future. Also, in the SCM, studies to improve water utilization ratio and efficiency, to find the optimum height of the siphon for decreasing the average drain rate, and to determine the radius of curvature of throat have to be conducted in advance, since a large flow rate is drained during the priming action of the siphon.

  • PDF

Performance Evaluation of a Thermo Siphon Type Radiator for LED Lighting System by using an Inverse Heat Transfer Method (역열전달해석기법에 의한 LED 조명용 무동력 냉각사이클링 방열기 성능평가)

  • Kim, E.H.;Kim, H.K.;Seo, K.S.;Lee, M.K.;Cho, C.D.
    • Transactions of Materials Processing
    • /
    • v.20 no.7
    • /
    • pp.473-478
    • /
    • 2011
  • In this study, the performance of a thermo siphon type radiator made of copper for LED lighting system was evaluated by using an inverse heat transfer method. Heating experiments and finite element heat transfer analysis were conducted for three different cases. The data obtained from experiments were compared with the analysis results. Based on the data obtained from experiments, the inverse heat transfer method was used in order to evaluate the heat transfer coefficient. First, the heat transfer analysis was conducted for non-vacuum state, without the refrigerant. The evaluated heat transfer coefficient on the radiator surface was 40W/$m^2^{\circ}C$. Second, the heat transfer analysis was conducted for non-vacuum state, with the refrigerant, resulting in the heat transfer coefficient of 95W/$m^2^{\circ}C$. Third, the heat transfer analysis was conducted for vacuum state, with refrigerant. For the third case, the evaluated heat transfer coefficients were 140W/$m^2^{\circ}C$. Third, the heat transfer analysis was conducted for vacuum state, with refrigerant. For the third case, the evaluated heat transfer coefficients were 140W/$m^2^{\circ}C$ for the radiator body, 5W/$m^2^{\circ}C$. Third, the heat transfer analysis was conducted for vacuum state, with refrigerant for the rising position of radiator pipe, 35W/$m^2^{\circ}C$. Third, the heat transfer analysis was conducted for vacuum state, with refrigerant. For the highest position of radiator pipe, and 120W/$m^2^{\circ}C$ for the downturn position of radiator pipe. As a result of inverse heat transfer analysis, it was confirmed that the thermal performance of the current radiator was best in the case of the vacuum state using the refrigerant.

Effects of Protease Treatment and Animal Behavior on the Dissociative Culture of Aplysia Neurons

  • Lee, Nuribalhae;Rim, Young-Soo;Kaang, Bong-Kiun
    • Animal cells and systems
    • /
    • v.13 no.3
    • /
    • pp.267-274
    • /
    • 2009
  • The dissociative culture technique of Aplysia neuron is one of the key methods that have been used for studies of cellular and molecular mechanisms of neuronal functioning. However, despite the advantages this method offers as an experimental model, its technical efficiency has had room for improvement. In this study, we examined certain putative factors that might affect the culture quality. The effects of neuronal damage induced by physical injuries, heat shock, and surface protein degradation were evaluated along with the correlation between the culture quality and animal behavior. As a result, we found that physical injury can be a critical factor that affects culture quality, whereas the heat shock and surface protein degradation had negligible effect on it. In addition, we discovered that siphon retraction time was not a good measurement for healthy neurons. Based on these findings, we suggest here an improved method in which the degree of physical injury is reduced by means of multiple protease treatment.

The Clinical Study on Bell's Palsy Patients with TCD Measurement (TCD를 이용한 말초성(末梢性) 구안괘사환자에 대(對)한 임상적(臨床的) 고찰(考察))

  • Lee, Byung-Ryul;Ann, Taek-Won;Lee, Hyun
    • Journal of Pharmacopuncture
    • /
    • v.6 no.2
    • /
    • pp.91-104
    • /
    • 2003
  • Objective : This study was carried to make out the connection between cerebral artery blood flow velocity and ischemic theory that presumed the cause of Bell's palsy. Method : We measured cerebral artery blood flow velocity each external carotid artery, internal carotid artery, common carotid artery, siphon, superficial temporal artery by TCD to 20 patients who diagnosed as facial nerve palsy from march 2001 to July 2001 and all objectives devided two groups as palsy side. A group is right side facial nerve palsy and B group is left facial nerve palsy. Results : 1. There is no effective change of blood flow in external carotid artery either A, B group. 2. There is no effective change of blood flow in internal carotid artery either A, B group. 3. There is no effective change of blood flow in common carotid artery either A, B group. 4. There is no effective change of blood flow in siphon artery either A, B group. 5. There is no effective change of blood flow in superficial temporal artery either A, B group.