• Title/Summary/Keyword: sinusoidal loads

Search Result 112, Processing Time 0.03 seconds

Unified Controller for 100kVA Emergency Generator (100kV급 비상발전기용 통합제어기)

  • Jeong, C.Y.;Cho, J.G.;Baek, J.W.;Lee, J.J.;Kim, Y.J.;Yoo, D.W.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07f
    • /
    • pp.2801-2803
    • /
    • 1999
  • An unified controller for emergency generator is presented to control AVR and Governor and l00kVA power conditioner. This controller is operated to compensate current harmonics and asymmetries caused by nonlinear load and unbalance loads. The power conditioner shapes the source current sinusoidal in phase with source voltage and allows the generator to maximum power even to the single phase load. Also this power conditioner allows that three phase generator synchronizes with single phase main source and load sharing. An l00kVA generator system was built and the unified controller is realized with DSP(TMS320C32PCMA). Experimental results for many load conditions are presented to verify the performance of the unified controller.

  • PDF

능동 제어를 이용한 공작기계용 정압베어링의 성능 향상에 관한 연구

  • 강선호;박준호;조형석
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1992.10a
    • /
    • pp.249-254
    • /
    • 1992
  • Hydrostatic Bearings have been applied to ultra high precision machine tools and precision instruments, because of their low friction characteristic, high load carrying capacity and high moving accuracy at all range of speed. In regard to realizing the Hydrostatic Bearing, various restrictors such as capillary, orifice, diaphram valve, spool valve, and etc can be used. However, their stiffness and flexibility are not sufficient in practical use for ultra precision machine tool elements. In this study dynamic equations were derived and the dynamic characteristics were simulated for both orifice and flow control servo valve. Simulation was carried out on the condition that static and sinusoidal dynamic loads were applied to the table of CNC jig Boring machine. The simulation results indicate the improvement of the performance of the Bearing system when flow control servo valve has been used as restrictor of Hydrostatic Bearing.

Analysis of 3 Phase utility interactive photovoltaic power generation system (3상 태양광발전시스템의 계통연계운전 해석)

  • Kim, Woo-Hyun;Kim, Chang-Il;Kim, Bong-Tae;Yu, In-Keun
    • Proceedings of the KIEE Conference
    • /
    • 1999.11b
    • /
    • pp.236-238
    • /
    • 1999
  • This paper presents a model and analysis results of 3 phase utility interactive photovoltaic power generation system. The control system is composed of feed forward, feedback and PID system. The voltage source inverter system provides sinusoidal PWM at current for the loads of utility system. A phase to ground fault and 3 phase fault are analyzed, and the results are discussed.

  • PDF

Development of the 300kVA Large Capacity IGBT UPS (IGBT를 적용한 300kVA급 대용량 무정전전원장치 개발)

  • Byun, Y.B.;Kim, T.J.;Joe, K.Y.;Park, S.J.;Kim, C.U.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07f
    • /
    • pp.2057-2059
    • /
    • 1998
  • In order to maintain a high quality output voltage, conventional UPS systems use complex filters with large passive components. To overcome this drawback, real time feedback control schemes have been invested. However, these techniques require a high inverter switching frequency to dynamically adapt to changing load conditions reduce harmonics of the output voltage, thereby rendering the system inadequate for high power applications. This paper presents real time digital signal processor(DSP) control of a large capacity UPS system feeding nonlinear loads to provide a sinusoidal inverter output voltage, unity input power factor, low bus voltage ripple, and excellent transient response.

  • PDF

A Study on the Nonlinear Dynamic Behaviors of Arches due to the Change of Shapes and Boundary conditions (형상과 단부조건에 따른 아치의 비선형 동적거동)

  • 여동훈;이상호
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1998.04a
    • /
    • pp.441-448
    • /
    • 1998
  • In this study, an explicit transient analysis program considering material and geometric nolinearities has been developed and used to analyze the dynamic behaviors of circular, parabolic, sinusoidal and catenary arches according to the change of shapes and boundary conditions. To understand dynamic behaviors of arches, first of all, the results of free vibration analysis for four kinds of arches are discussed. The results of transient analysis under impact loads we discussed in respect of boundary condition, change of height, and arch-shape. The dynamic behaviors of arches by nonlinear transient analysis considering both material and geometric nolinearities are also discussed.

  • PDF

Dynamic Voltage Restorer(DVR) with a Z-Source AC Converter Topology (Z-소스 교류 컨버터 토폴로지의 동적 전압 보상기)

  • Lim, Young-Cheol;Jung, Young-Gook
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.9
    • /
    • pp.36-43
    • /
    • 2010
  • This paper proposes a new type of voltage sag-swell compensator based on a Z-source AC-AC converter. The proposed topology employs a pulse width modulation (PWM) Z-source AC-AC converter along with a injection transformer. A safe commutation strategy is used to eliminate voltage spikes on switches without snubber circuit. During a voltage sag or swell, the proposed system controls the adding or missing voltage and maintains the rated voltage of sinusoidal waveform at the terminals of the critical loads. The proposed system is able to compensate 20[%] voltage swell and is also able to compensate 60[%] voltage sag. In order to control and detect the voltage sag and swell, the peak voltage detection method is applied. Also, the operating principles of the proposed system are described, and a circuit analysis is provided. Finally, PSIM simulation and experimental results are presented to verify the proposed concept and theoretical analysis.

Modulated Carrier Control for Single-Phase Active Power Filter

  • Son, Gibong;Kim, Hyejin;Cho, Bo-Hyung
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.218-219
    • /
    • 2013
  • In this paper, an improved modulated carrier control for a single-phase shunt active power filter(SAPF), which eliminates harmonic currents at the ac main drawn by nonlinear loads, is introduced. In contrast to conventional methods, since this control method does not need to generate a current reference for SAPF, only the ac main current is sensed instead of the load current and SAPF current. With the proposed control method, the ac main current is directly controlled to be sinusoidal and in phase with the supplied ac voltage by simply comparing the modulated carrier signal with the ac main current. The operation of the proposed SAPF is analyzed and simulation results verify its performance.

  • PDF

Analytical and experimental postbuckling of conditioned cables

  • Rivierre, L.;Polit, O.;Billoet, J.L.
    • Structural Engineering and Mechanics
    • /
    • v.12 no.6
    • /
    • pp.595-614
    • /
    • 2001
  • This paper studies the behaviour of a homogeneous cable in a horizontal rigid duct and loaded by an axial compressive force. This behaviour is characterized by spatial buckling modes, named sinusoidal and helical, due to friction and total or partial cable locking. The evaluation of critical buckling loads involved by drilling technology has been studied by many authors. This work presents a new formulation, taking the friction effects into account, for the transmission of the axial load during the postbuckling process. New analytical expressions of pitches in both buckling cases are also given. A life-sized bench is presented, which permits to study the laying of optical fiber cables by squeezing them into an underground duct. Finally, analytical solutions are compared with experimental tests and finite element simulations.

Control Characteristics of Three-Phase Utility Interactive Phovotovoltaic Power Generation System (3상 계통연계 태양광발전시스템의 운전특성)

  • Kim, Yeong-Cheol;Jeong, Myeong-Ung;Seo, Gi-Yeong;Lee, Hyeon-U;U, Jun-In
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.49 no.8
    • /
    • pp.536-543
    • /
    • 2000
  • The photovoltaic power generation system has a great future as clean energy instead of fossil fuel which has many environmental problems such as exhausted gas or air pollution. In a utility interactive photovoltaic generation system, a three-phase inverter is used for the connection between the photovoltaic array and the utility. This paper present a three phase inverter for photovoltaic power system with current controller, voltage controller, PLL Control system and the Phase detector of Interactive Voltage by using dq transformation. The proposed inverter system provides a sinusoidal ac current for domestic loads and the utility line with unity power factor.

  • PDF

The Construction and Operating Characteristics analysis of Utility interactive PV power generation system (계통연계형 태양광 발전시스템의 운전특성 해석과 문제점 분석)

  • Hong, D.S.;Koh, K.H.;Koh, H.S.;Lee, H.W.
    • Proceedings of the KIEE Conference
    • /
    • 2001.10a
    • /
    • pp.334-336
    • /
    • 2001
  • The photovoltaic power generation system has a great future as clean energy instead of fossil fuel which has many environmental problems such as exhausted gas or air pollution. In a utility interactive photovoltaic generation system, a three-phase inverter is used for the connection between the photovoltaic array and the utility. This paper presents a three phase inverter for photovoltaic power system with current controller, voltage controller PLL control system and the phase detector of interactive voltage by using do transformation. The proposed inverter system provides a sinusoidal are current for domestic loads and the utility line with unity power factor. The results of the operated from January to October show the system characteristics.

  • PDF