• Title/Summary/Keyword: sinking pulse

Search Result 24, Processing Time 0.028 seconds

Characteristics of Die Sinking Electical Discharge Machining for Pulse Duration (펄스지속시간에 따른 형상방전가공 특성)

  • 우정윤;왕덕현;윤존도
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.827-831
    • /
    • 1997
  • Conductive veramic matrix composite(CMC) workpiece of TiC 33%/Al /sab 2/O /sab 3/ 66% Y /sab 2/ O /sab 3/ was machined by die sinking electrical discharge machining(EDM) according to different pulse duration and suty factor for reverse polarity of electrode. Material removal rate(MRR) was examined by process under various operating conditions. The surface morphology was evaluated by surface roughness values and scanning electron microscopy(SEM) research. The more MRR was obtained according to increase pulse duration and duty factor. Also the maximum surface roughness(Rmax) of EDMed surface was slightly changed with increased pulse duration and duty factor. The SEM photographs of EDMed surface showed wide recast wide recast distribution region of melting materials in purse duration 0.130(ms) than 0.048(ms).

  • PDF

Clinical Study on the Sasang Constitutional Pulse Using Array Piezoresistive Sensor (어레이 압저항 센서를 활용한 체질맥 임상연구)

  • Lee, Si-Woo;Joo, Jong-Cheon;Kim, Kyung-Yo;Kim, Jong-Yeol
    • Journal of Sasang Constitutional Medicine
    • /
    • v.18 no.1
    • /
    • pp.118-131
    • /
    • 2006
  • 1. Objective Pulse diagnosis is generally applied to Traditional Oriental Medicine but not to Sasang Constitution diagnosis. Recently new pulse analyzer using array piezoresistive sensor and multi-channel robot arm developed. It reflects Oriental Medical Doctors' diagnostic processes, and its reproducibility test was done at Korea Institute of Oriental Medicine. We performed this study to set parameters diagnosing Sasang Constitution. 2. Methods One hundred thirty three subjects participated in this study. They are healty and approved this study. Before being tested with pulse analyzer, they had interview with Sasang Constitution Specialist to diagnose their Sasang Constitution. We established some useful parameters from parameters of pulse analyzer according to the Original Texts of Oriental Medicine and clinical experiences to analyze with clinical data of this study. 3. Results (I) There is a significant difference in pre-dicrotic notch time among all parameters of pulse analyzer in Sasang Constitution groups(P=0.047). (2) There is a significant difference in maximum pulse pressure in 33 to 48 year Sasang Constitution groups(P=0.010). (3) There is a significant difference in frequency width in 17 to 32 year Sasang Constitution groups(P=0.002). (4) There is a significant difference in CFS value in groups which OMD diagnoses; Floating & Sinking pulse(P=0.020). (5) There is a significant difference in pulse rate in groups which OMD diagnoses; Rapid & Slow pulse(P=0.000). (6) There is a significant difference in maximum pulse pressure in groups which OMD diagnoses; Deficient & Solid pulse(P=0.000). 4. Conclusions Analyzing parameters in each Sasang Constitution group, we found it shows significant difference in maximum pulse pressure and corresponding tendency in coefficient of floating & sinking pulse with theories of Sasang Consti-tutional Medicine. As we accumulate more clinical data, we will establish algorithm to diagnose Sasang Constitution using a pulse analyzer.

  • PDF

The literature study on the individual characteristic factor by the interrogation of history taking and palpation (소증(素證)과 맥진(脈診)에서의 개체성(個體性) 관찰(觀察)에 대한 문헌적(文獻的) 고찰(考察))

  • Kim, Gyeong Cheol;Lee, Hae Woong
    • Journal of Korean Medical classics
    • /
    • v.27 no.3
    • /
    • pp.1-10
    • /
    • 2014
  • Objectives : For the excellent differentiation of syndromes, we study on the individual characteristic factor by the interrogation of history taking and palpation. Methods : To the subject of diagnosis special books and diagnostics textbook of korean medicine, we arrange the individual characteristic factor by the interrogation of history taking and palpation. Results : The interrogation of history taking on the individual characteristic factor was arranged dispositional symptoms and individual characteristic of syndromes. And the pulse taking and palpation on the individual characteristic factor was arranged the moderate person's pulse condition ; floating pulse, deep and sinking pulse, replete and forceful pulse, intermittent pulse, long pulse, slippery or smooth pulse, relaxed or loose pulse (浮沈實大長滑緩脈), six Yin and six Yang pulse (六陽脈, 六陰脈). Conclusions : As the results, the individual characteristic factor is very important item of the four methods of diagnosis and the differentiation of syndromes. And therefore, we have to divide the signs of individual characteristic factor and the signs of disease in the process on four methods of diagnosis and differentiation of syndromes.

A Study on the Sasang Constitutional Differences in the Pulse Wave of Korean Healthy Adult Men (한국인 성인 남성의 체질별 맥상 특성에 관한 연구)

  • Kim, Ho-Seok;Ryu, Hyun-Hee;Lee, Si-Woo
    • Korean Journal of Oriental Medicine
    • /
    • v.13 no.2 s.20
    • /
    • pp.71-74
    • /
    • 2007
  • Background : Sasang Constitutional Medicine (SCM) is the field of traditional Korean medicine that emphasize four constitutional types for diagnosis and treatment. Appearance, personalities and pathological characteristics are main factors of Sasang constitutional classification. Previous studies carried out by the pulse analyzer showed that the pulse wave can discriminate these types. In addition, It was reported that the pulse wave are affected by age and sexuality. In this study, we investigated the pulse wave characteristics related Sasang constitution types in control group regarding their age and sexuality. Subjects and Method : Two hudred and eighteen volunteers participated in this study: healthy men in $20{\sim}49$ years old. Participants were interviewed and examined to evaluate their health condition and Sasang constitution type. Then they were tested with pulse analyzer when they ere stabilized. The pulse at the radial artery just beside styloid process was measured, because this area is landmark for pulse diagnosis in oriental medicine. 3-D Mac pulse analyzer (Daeyo Medi Co. Ansan. Korea) was used in this study. We analyzed main features of pulse waves with the Sasang condtitution types by the SPSS for Windows (ver 12.0). Results : There was significant difference between Taeum and other types in contact pressure as weil as in coefficient of floating and sinking pulse. Conclusion : By analyzing pulse waves of healthy adult men. we found significant differences exist between Taeum and other types. These pulse differences may characterize Taeum type, and it will be helpful for the evaluation of Taeum type.

  • PDF

Effect of Laser Acupuncture on Arterial Pulse

  • Cho, Jaekyong;Kang, Dong Hwan
    • Journal of Biomedical Engineering Research
    • /
    • v.36 no.5
    • /
    • pp.191-197
    • /
    • 2015
  • Laser acupuncture is defined as the stimulation of traditional acupuncture points with low-intensity, nonthermal laser irradiation. Possible advantages in using laser acupuncture are the noninvasive, painless and low risks of infection treatment. The purpose of this study is to assess the effect of laser acupuncture on the quality and waveform of arterial pulses. Ten acupuncture points were stimulated repeatedly three times in 30 individuals by laser with emission in the near infrared spectral region (808 nm) using an out power and power density of 45 mW and $143W/cm^2$. The analysis of pulse quality and waveform was performed based on the measurement of arterial pressure of the left and right wrist, using a 3-dimensional blood pressure pulse analyzer. Excess-like pulse quality of subjects before laser acupuncture changed significantly to balanced pulse quality after 10, 20, and 30 minutes of laser acupuncture; coefficient of deficient or excess, $C_{DE}$, decreased significantly from 0.68 before acupuncture to 0.61, 0.55, and 0.55 after 10, 20, 30 minutes of laser acupuncture ($$p{\leq_-}0.006$$), respectively. Other pulse qualities, floating or sinking, slow or rapid, choppy or slippery did not change significantly by laser acupuncture (p > 0.05). Pulse waveform analysis showed that amplitude of main peak (systolic function or aortic compliance, $h_1$) of left and right artery pulse waves decreased significantly after 10, 20, and 30 minutes of laser acupuncture (p < 0.05). Other parameters, duration of one cardiac cycle (T), duration of rapid systolic ejection ($T_1$), duration of the systolic phase ($T_4$), and duration of the diastolic phase ($T_5$) of left and right artery pulses did not change significantly after laser acupuncture (p > 0.05).

The thermal analysis of te-based media for the optical recording (광기록에 이용되는 Te-based media에 대한 열적 해석)

  • 이성준;천석표;이현용;정홍배
    • Electrical & Electronic Materials
    • /
    • v.8 no.1
    • /
    • pp.64-70
    • /
    • 1995
  • We discussed the thermal analysis for a recording media with the variation of the laser pulse duration, the laser power and the temperature distribution in order to optimize the Te-based antireflection structure from the computer calculations. In the case that the radial heat diffusion is negligible, we can calculate the maximum temperature of the recording layer at the center of the spot by the Simple Model. The temperature profile of the recording layer is obtained from the Numerical Model by considering the total specific heat and the latent heat. As a result, the effect of the heat sinking acting as a thermal loss for the hole formation could be minimized by introducing the pulse with the hole formation duration(.tau.) below the thermal time constant(.tau.$_{D}$) of a dielectric layer. These requirments can be satisfied by using the dielectric thickness of the 2nd ART(Anti-Reflection Trilayer) condition or the dielectric materials with a low thermal diffusivity.y.

  • PDF

The Thermal Analysis of Te-based media for Optica1 Recording (광기록에 이용되는 Te-based Mediao에 대한 열적 해석)

  • 천석표;이성준;이현용;정홍배
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1994.05a
    • /
    • pp.123-126
    • /
    • 1994
  • We discussed the thermal analysis for recording media with the variation of the laser pulse duration and the power and the temperature distribution for the optimized Te-based antireflection structure by using the computer calculations. If the radial diffusion of heat is negligible, we can calculate the maximum temperature at the spot center in recording layer by Simple Method, and the temperature profile considering the specific heat and the latent heat by Numerical Method. As a result, the effect of the heat sinking which acted as a loss for the hole formation can be minimized by introducing the pulse of the hole formation duration( $\tau$ ) shorter than the thermal time constant( $\tau$$\sub$D/) of dielectric layer. This requirments can be satisfied as using the dielectric thickness of the 7nd ART condition or the dielectric materials with low thermal diffusivity.

  • PDF

Considerations on an Oriental Medical Doctor like Indentation System (한의사 맥진 가압력 재현에 대한 고찰)

  • Lee, Jeon;Woo, Young-Jae;Jeon, Young-Ju;Lee, Yu-Jung;Ryu, Hyun-Hee;Kim, Jong-Yeol
    • Korean Journal of Oriental Medicine
    • /
    • v.14 no.3
    • /
    • pp.113-119
    • /
    • 2008
  • In pulse diagnosis, the indentation pressure is one of the most important factors as well as the change of pulse shape and the distribution of pressure via time. But, on the oriental medical doctor's indentation pressure control, the understandings of the neurophysiological meanings and mechanisms have been lacked. So, in this paper, we considered on these issues and then proposed a proper system which can imitate the OMD's indentation pressure control mechanisms. As a result, both tactile information and kinesthetic information were found to be essential to the indentation pressure control so that a system, which can measure both the physical indent pressure and the displacement of an indentation arm, has been proposed. With this proposed system, while the indentation was being controlled through the moving step number of the step motor, the physical indentation pres sure and displacement of the indentation arm were measured. From these measured data, the relationships between the moving step number and both physical indentation pressure and displacement were revealed to have linear characteristics in early phase and to have nonlinear characteristics in latter phase. Additionally, three types of graph were generated whose X axis means the moving step number, the physical indentation pressure and the displacement respectively and Y axis means the pulse pressure. By comparing these graphs, we come to conclude that different concepts on indentation pressure control cause different diagnostic results on floating/sinking degrees for the same subject. Consequently, an indentation system for the pulse diagnosis should be able to provide both the tactile information and kinesthetic information, that is, the physical indentation pressure and the displacement of the indentation arm. In future, the proposed system should be optimized to the pulse diagnosis environment and how to combine the both information for more reliable diagnosis should be studied.

  • PDF

Electron Discharge Machining (EDM) and Hole EDM of Cold Heat-treated Tool Steel Molds (STD11) by using Cu Electrodes (냉간 금형용 공구강의 Cu 전극을 이용한 방전 홀에 관한 연구)

  • Park, In-Soo;Lee, Eun-Ju;Kim, Hwa-Jeong;Wang, Deok-Hyun
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.17 no.4
    • /
    • pp.76-82
    • /
    • 2018
  • 3D formed Electrical Discharge Machining (EDM) and hole EDM were conducted for die and mold manufacturing with electrodes which were made by mechanical machining and wire EDM. It is difficult to machine the hardened material after heat treatment and quenching with traditional machining. The only method of machining hardened material is die-sinking EDM. In this research, hole EDM was conducted for heat-treated cold-worked tool steel (SKD11) for use as a die material. The EDM surfaces were analyzed by pulse-on time and peak current of EDM current, according to the machining conditions of EDM. The EDM surface profiles were affected by the peak current. The contribution of each factor is peak current (91.63%) and pulse-on time (0.93%). The best surface roughness was obtained with a $130{\mu}s$ pulse-on time and a 14.2 A peak current. With uniform EDM processing, the surface deteriorated with increasing pulse-on time and peak current. The thickness of the solidified layer induced by EDM was increased as the peak current, crater shapes, and erupted shapes of EDM surfaces were increased. Therefore, microcracking gaps induced by surface tension were increased.

Survey Study about Sasangin's Characteristics of Face, Voice, Skin and Pulse Diagnosis (사상인(四象人)의 안면, 음성, 피부 및 맥진 특성에 관한 설문조사 연구)

  • Lee, Jun-Hee;Kim, Yun-Hee;Hwang, Min-Woo;Kim, Jong-Yeol;Lee, Eui-Ju;Song, Il-Byung;Koh, Byung-Hee
    • Journal of Sasang Constitutional Medicine
    • /
    • v.19 no.3
    • /
    • pp.126-143
    • /
    • 2007
  • 1. Objectives The purpose of this study is to find out the grade of practical use, the important element and the significant characteristics of Sasangin' s face, voice, skin and pulse diagnostic impression, in Sasang constitutional clinical diagnosis. 2. Methods We analysed the survey data about Sasangin' s face, voice, skin and pulse diagnostic impression, drawn up by specialist in Sasang constitutional medicine. 3. Results and Conclusions (1) In the application degree of face feature, the case which it was applied with 20-40% and 40-60% were 16 people(43.2%) respectively. In voice, the case applied with 0-20% was 19 people(51.4%), in skin, 0-20% and 20-40% were 14 people(37.8%) respectively and in pulse diagnosis, 0-20% were 25 people(73.0%). (2) In constitutional diagnosis, the important element of face were 'frontal whole shape', 'whole impression' and 'size and shape of eye, ear, mose and mouth', the important element of voice 'speed of speech', 'purity and impurity' and 'pitch', the important element of skin 'thickness', 'feel of touch' and 'size of skin pores' and the important element of pulse diagnosis 'speed of pulse', 'sinking and floating' and 'weakness and firmness'. (3) The important face characteristics of Taeyangin were 'bright eye', 'broad forehead' and 'strong impression', Soyangin 'protruding forehead', 'thin and small lips', 'narrowing and sharp chin', Taeumin 'thick lips', 'flat face', 'large eye, nose, ear and mouth' and Soeumin 'long and slender face', 'downward slanting eyes' and 'small eye, nose, ear and mouth', The important voice characteristics of Taeyangin were 'loud' and 'clear', Soyangin 'rapid' and 'high-pitched tone', Taeumin 'chick', 'slow' and 'low-pitched tone' and Soeumin 'small and feeble' and 'slow'. The important skin characteristics of Taeyangin were 'thin' and 'white', Soyangin 'thin', 'smooth' and 'elastic', Taeumin 'thick', 'large skin-pore', 'coarse' and Soeumin 'soft', 'thin' and 'subtle skin-pore'. The important pulse characteristics of Taeyangin were 'rapid' and 'large', Soyangin 'rapid' and 'floating', Taeumin 'tense', 'long' and 'solid' and Soeumin 'fine', 'weak' and 'slow'.

  • PDF