• Title/Summary/Keyword: single-pass

Search Result 485, Processing Time 0.032 seconds

A study on the architecture and logic block design of FPGA (FPGA 구조 및 로직 블록의 설계에 관한 연구)

  • 윤여환;문중석;문병모;안성근;정덕균
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.33A no.11
    • /
    • pp.140-151
    • /
    • 1996
  • In this study, we designed the routing structure and logic block of a SRAM cell-based FPGA with symmetrical-array architecture. The designed routing structure is composed of switch matrices, routing channels and I/O blocks, and the routing channels can be subdivided into single length channels, double length channels and global length channels. The interconnection between wires is made through SRAM cell-controlled pass transistors. To reduce the signal delay in pass transistors, we proposed a scheme raising the gate-control voltage to 7V. The designed SRAM cells have built-in shift register capability, so there is no need for separate shift registers. We designed SRAM cells in the LUTs(look-up tables) to enable the wirte operations to be performed synchronously with the clock for ease of system application. Each logic block (LFU) has four 4-input LUTs, flip-flops and other gates, and the LUTs can be used a sSRAM memory. The LFU also has a dedicated carry logic, so a 4-bit adder can be implemented in one LFU. We designed our FPGA using 0.6.mu.m CMOS technology, and simulation shows proper operation of a 4 bit counter at 100MHz.

  • PDF

The Design Simulation for Manufacture of High Frequence Ceramic Filter (고주파용 세라믹 필터의 제작을 위한 디자인 해석)

  • Lee, S.H.;Seok, J.Y.;Ryu, G.H.;SaGong, G.;Yoon, K.H.;Yoo, J.H.;Park, C.Y.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11b
    • /
    • pp.418-421
    • /
    • 2001
  • The ceramic filters were developed using technology similar to that of quartz crystal and electromechanical filter. However, the key to this development involved the theoretical analysis of vibration modes and material improvements of piezoelectric ceramics. The primary application of ceramic filters has been for consumer-market use. Accordingly, a major emhpasis has involved mass production technology, leading to low-priced devices. A typical ceramic filter includes monolithic resonators and capacitors packaged in unique configurations. Nakazawa developed a double-mode resonator as two acoustically coupled single resonators. And he developed 10.7MHz crystal filters using multi-energy trapping mode of thickness shear vibration. He succeeded in realizing a two-pole band pass filter response without external inductance by splitting a dot electrode to creat coupled symmetric and antisymmetric vibration modes. Accordingly, the simulation for ceramic filter were important. So that, this paper were investigated the pass frequency of filter on the electrode length and thickness of ceramic.

  • PDF

Performance Analysis and Optimal Design of Heat Exchangers Used in High Temperature and High Pressure System

  • Kim, Yang-Gu;Choi, Byoung-Ik;Kim, Kui-Soon;Jeong, Ji-Hwan
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.11 no.1
    • /
    • pp.19-25
    • /
    • 2010
  • A computational study for the optimal design of heat exchangers (HX) used in a high temperature and high pressure system is presented. Two types of air to air HX are considered in this study. One is a single-pass cross-flow type with straight plain tubes and the other is a two-pass cross-counter flow type with plain U-tubes. These two types of HX have the staggered arrangement of tubes. The design models are formulated using the number of transfer units ($\varepsilon$-NTU method) and optimized using a genetic algorithm. In order to design compact light weight HX with the minimum pressure loss and the maximum heat exchange rate, the weight of HX core is chosen as the object function. Dimensions and tube pitch ratio of a HX are used as design variables. Demanded performance such as the pressure loss (${\Delta}P$) and the temperature drop (${\Delta}T$) are used as constraints. The performance of HX is discussed and their optimal designs are presented with an investigation of the effect of design variables and constraints.

Design and Fabrication of NRD Guide Filter using Inductive Iris (유도성 아이리스를 이용한 NRD 가이드 필터의 설계 및 제작)

  • 김영수;류원렬;최형동;유영근
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.13 no.8
    • /
    • pp.741-747
    • /
    • 2002
  • In this paper, NRD guide band pass filter with newly designed inductive iris structure is proposed and analyzed with its test results. In case of common NRD guide filter with air gap coupled structure, it was not easy to fabricate and process or each NRD guide dielectric resonator blocks using PTFE. However, in this our research, each dielectric resonator fabricated in a single NRD guide is coupled with inductive iris located on metal plates. The structure is suitable for mass production of a precise and reliable millimeter-wave filter applications. As a result of measurements, designed NRD guide inductive iris filter has superior performance. The pass band is 38.66~39.06 MHz with 400 MHz bandwidth, insertion loss is about 1.4 dB and return loss is below -18 dB.

A Study on the Development & Evaluation of Defense Quality Maturity Index (국방품질성숙도지수의 개발 및 평가에 관한 연구)

  • Jeong, Younggkwon;Cho, Hyunki;Yoo, Hanjoo
    • Journal of Korean Society for Quality Management
    • /
    • v.47 no.3
    • /
    • pp.479-496
    • /
    • 2019
  • Purpose: The purpose of this research is to develop defense quality evaluation model in order to improve the problem of private sector quality evaluation model and propose the total integrated defense quality management model which enables to evaluate not only large defense industry, but also small-medium industry. Methods: This paper consider the characteristics on ISO 9001 Quality Management System, single PPM, PASS and defense quality and develop defense quality maturity model and index which enables to measure the current quality management level and characteristics and to evaluate operational characteristics in each maturity level for domestic defense industry. Results: From 176 DQMS certified defense industry, the defense quality maturity level is 68,2, C grade. The large defense industry shows, 80.9, A grade; medium industry 69.7, C grade; small-medium industry shows 54.1, D grade. Through the classified types of industries, the current level of quality management of defense industries was diagnosed and the areas to be supplemented for the total quality management were identified. Conclusion: Developed DQMI can be used as the basic information for spreading quality management activities in the defense industry by diagnosing the overall quality management of existing defense industries and quantifying the ambiguity of non-metric measurements and measurement standard that were presented as the threshold of the defense quality management system certification process.

Effect of Na Substitution for the Ca Site in the Bi$_2$Sr$_2$Ca$_{1-x}$Na$_x$Cu$_2$O$_{8+y}$ Superconductors (Bi$_2$Sr$_2$Ca$_{1-x}$Na$_x$Cu$_2$O$_{8+y}$ 산화물 고온초전도체의 Ca 위치에 Na 치환 효과)

  • 이민수;송승용;이종용;송기영;최봉수
    • Journal of the Korean Ceramic Society
    • /
    • v.35 no.10
    • /
    • pp.1007-1013
    • /
    • 1998
  • The samples of Bi2Sr2Ca1-xNaxCu2O8+y with various carrier concentration were synthesized by substituting Na for Ca ion. The superconducting properties hall coefficients and X-ray powder diffraction were measur-ed the sampled. Single phase samples were obtained for 0$\leq$x<0.3 of Bi2Sr2Ca1-xNaxCu2O8+y In the single phase the critical temperature. {{{{ { T}_{c } }} and carrier concentration increase with the increase of Na concentration pass through a maximum and then decreases. In the range of x$\geq$0.7 to the Na doped samples however we observed the metal-semiconductor transition. The c-axis seemed to decrease and a and b-axes increase with increasing Na concentration in the single phase. Decreasing of c-axis while increasing x is due to the smaller size of {{{{ {Na}^{+1 } }} ions to the {{{{ { Ca}^{+2 } }} ions. In the range of x>0.3 however the trend becomes ambiguous due to the inclusion of the 10K phase and impurity phase.

  • PDF

Analysis of Active Islanding Dectetion Methods for a Single-phase Photovoltaic Power Conditioning Systems (단상 계통연계형 PCS의 단독운전 검출기법 비교 분석)

  • Jung Youngseok;So Jeonghun;Yu Gwonjong;Kang Gihwan;Choi Jaeho
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.1477-1479
    • /
    • 2004
  • Increasing numbers of photovoltaic arrays are being connected to the power utility through the power conditioning systems (PCS). This has raised potential problems of network protection. If, due to the action of the PCS, the local network voltage and frequency remain within regulatory limits when the utility is disconnected, then islanding is said to occur. In this paper, the representative methods to prevent the islanding are described and a PSIM-based model and analysis of the reactive power variation (RPV) method are presented. A novel phase detector using the all-pass filter and digital phase locked loop (DPLL) is proposed especially for the single-phase PCS. Finally, this paper provides the simulation and experimental results with a single-phase 3kW prototype PCS. Islanding test method of IEEE Std. 929-2000 was performed for verification.

  • PDF

Far-End Crosstalk Compensation for High-Speed Interface (고속 인터페이스를 위한 원단누화 보상 기술 동향)

  • Lee, Won-Byoung;Kong, Bai-Sun
    • Journal of IKEEE
    • /
    • v.23 no.3
    • /
    • pp.1046-1053
    • /
    • 2019
  • In a multi-channel single-ended system, the far-end crosstalk (FEXT) due to mutual inductance and mutual capacitance between two adjacent channels critically limit the bandwidth. FEXT causes crosstalk-induced jitter (CIJ) and crosstalk-induced glitch (CIG) which leads to timing margin and voltage margin degradations, respectively. Therefore, FEXT must be compensated in order to increase eye opening and achieve high data-rate. It can be compensated in transmitter by controlling the timing of the data or reshaping the waveform of the signal. Also, FEXT can be compensated in receiver by generating mimicked FEXT using high-pass filter. In this paper, recent techniques to compensate FEXT are investigated, with discussions of their pros and cons.

Realization on the Integrated System of Navigation Communication and Fish Finder for Safety Operation of Fishing Vessel (어선의 안전조업을 위한 항해통신 및 어탐기의 통합시스템 구현)

  • In-suk Kang;In-ung Ju;Jeong-yeon Kim;Jo-cheon Choi
    • Journal of Advanced Navigation Technology
    • /
    • v.25 no.6
    • /
    • pp.433-440
    • /
    • 2021
  • The problem of maritime accidents due to the carelessness of fishing vessels, which is affected by the aging of fishing vessel operators. And there is navigation, communication and fish finder that is installed inside the narrow bridge of a fishing vessel. Therefore these system are monitors as many as of each terminal, which is bad influence on obscuring view of front sea from a fishing vessel bridge. In addition a large problem, it is occurs to reduce of the information recognition ability due to the confusion, which is can not check the display information each of screen equipments. Therefore, there has been demand to simply integrated the equipment, and it has wanted the integrated support system of these equipment. The display must be provided on a fishing vessels such as electronic charts, communications equipments and fish detection into one case. In this paper, the integrated system will be installed the GPS plotter, AIS, VHF-DSC, V-pass, fish finder and power supply in the narrow wheelhouse on a fishing vessel, which is configured in one case and operated by multi function display (MFD). The MFD is integrated to simplify for several multi terminals and provided necessary information on a single screen. This integration fishery support system will has improved in sea safety operation and fishery environment of fishing vessels by this implementation.

Radiologic assessment of the optimal point for tube thoracostomy using the sternum as a landmark: a computed tomography-based analysis

  • Jaeik Jang;Jae-Hyug Woo;Mina Lee;Woo Sung Choi;Yong Su Lim;Jin Seong Cho;Jae Ho Jang;Jea Yeon Choi;Sung Youl Hyun
    • Journal of Trauma and Injury
    • /
    • v.37 no.1
    • /
    • pp.37-47
    • /
    • 2024
  • Purpose: This study aimed at developing a novel tube thoracostomy technique using the sternum, a fixed anatomical structure, as an indicator to reduce the possibility of incorrect chest tube positioning and complications in patients with chest trauma. Methods: This retrospective study analyzed the data of 184 patients with chest trauma who were aged ≥18 years, visited a single regional trauma center in Korea between April and June 2022, and underwent chest computed tomography (CT) with their arms down. The conventional gold standard, 5th intercostal space (ICS) method, was compared to the lower 1/2, 1/3, and 1/4 of the sternum method by analyzing CT images. Results: When virtual tube thoracostomy routes were drawn at the mid-axillary line at the 5th ICS level, 150 patients (81.5%) on the right side and 179 patients (97.3%) on the left did not pass the diaphragm. However, at the lower 1/2 of the sternum level, 171 patients (92.9%, P<0.001) on the right and 182 patients (98.9%, P= 0.250) on the left did not pass the diaphragm. At the 5th ICS level, 129 patients (70.1%) on the right and 156 patients (84.8%) on the left were located in the safety zone and did not pass the diaphragm. Alternatively, at the lower 1/2, 1/3, and 1/4 of the sternum level, 139 (75.5%, P=0.185), 49 (26.6%, P<0.001), and 10 (5.4%, P<0.001), respectively, on the right, and 146 (79.3%, P=0.041), 69 (37.5%, P<0.001), and 16 (8.7%, P<0.001) on the left were located in the safety zone and did not pass the diaphragm. Compared to the conventional 5th ICS method, the sternum 1/2 method had a safety zone prediction sensitivity of 90.0% to 90.7%, and 97.3% to 100% sensitivity for not passing the diaphragm. Conclusions: Using the sternum length as a tube thoracostomy indicator might be feasible.