• Title/Summary/Keyword: single-mode operation

Search Result 294, Processing Time 0.049 seconds

Active Power Filter Type Single Phase Uninterruptible Power Supply(UPS) System (단상 전력용 능동필터형 무정전 전원장치)

  • Kim, Je-Hong;Son, Jae-Hyun
    • Journal of the Korean Institute of Telematics and Electronics T
    • /
    • v.36T no.4
    • /
    • pp.53-59
    • /
    • 1999
  • In this paper, a bi-directional UPS with the performance of active power filter has been proposed. The operation of the proposed system can be divided into two modes, such as the active power filter mode and the battery back-up power mode. To improve the transient response for the effective compensation of harmonics and reactive power in active power filter mode, a novel closed-loop control strategy is used to calculate the reference current instantaneously. Finally, the performance of proposed UPS is verified by the simulation and experimental results.

  • PDF

Fabrication and Characteristics of GaAs/AlGaAs GRIN-SCH Quantum Well Laser Diode by MOCVD (MOCVD를 이용한 GaAs/AlGaAs GRIN-SCH 양자 우물 레이저의 제작 및 특성)

  • 손정환
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 1991.06a
    • /
    • pp.139-143
    • /
    • 1991
  • GRIN-SCH quantum well structured Laser Diode were fabricated using MOCVD and operated as CW at room temperature. The threshold current density of the LD with 670${\mu}{\textrm}{m}$ cavity length was 530 A/$\textrm{cm}^2$. For the ridge waveguide type index guiding structured LD with 6${\mu}{\textrm}{m}$ stripe width and 240${\mu}{\textrm}{m}$ cavity length, the threshold current was 50㎃. The maximum differential quantum efficiency was 0.95W/A when the optical output was 60mW. The lasing wavelength of QW LD was 865nm. In the L-I measurement. TE mode was superior to TM mode. From the near field pattern, single lateral mode operation was observed.

  • PDF

A Study on the Mode Conversion of Control in the Single Phase Switched Reluctance Motor (단상 SRM의 제어 모드 변환에 관한 연구)

  • Go, Sung-Chul;Ahn, Joon-Seon;Kim, Sol;Lee, Ju
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.635-636
    • /
    • 2006
  • A pulse with modulation(PWM) that keeps a constant angle of dwell and adjust duty ratio is a good method to control a speed of SRM. And a method of one pulse control is proper a operation on range of high speed in SRM for a good energy efficiency. Because PWM method is more safety than one pulse method, conversion of those is best choice according the speed range. So, some algorithm is need for smooth conversion of the mode of control. This paper presents a factor of conversion that proper the conversion of control mode between PWM and one pulse method This factor is from estimation of torque and proper at the variable range of conversion and show the better conversion characteristic than constant factor of conversion.

  • PDF

Widely Tunable Coupled-ring Reflector Laser Diode Consisting of Square Ring Resonators

  • Kim, Su-Hyun;Byun, Young-Tae;Kim, Doo-Gun;Dagli, Nadir;Chung, Young-Chul
    • Journal of the Optical Society of Korea
    • /
    • v.14 no.1
    • /
    • pp.38-41
    • /
    • 2010
  • We design and fabricate a widely tunable laser diode made of InGaAsP-InP. The diode is monolithically integrated with a wavelength-selective coupled-ring reflector and semiconductor amplifiers. For realization of a compact size device, deeply etched multi-mode interference couplers and square ring resonators composed of total-internal-reflection mirrors are adopted and fabricated using a self-aligned process. It is demonstrated that the laser diode exhibits single mode operation and 16 nm tuning range with side-mode-suppression-ratio exceeding 20 dB.

Seamless Mode Transfer of Utility Interactive Inverters Based on Indirect Current Control

  • Lim, Kyungbae;Song, Injong;Choi, Jaeho;Yoo, Hyeong-Jun;Kim, Hak-Man
    • Journal of Power Electronics
    • /
    • v.19 no.1
    • /
    • pp.254-264
    • /
    • 2019
  • This paper proposes an indirect current control technique based on a proportional resonant (PR) approach for the seamless mode transfer of utility interactive inverters. Direct-current and voltage hybrid control methods have been used for inverter control under grid-connected and islanded modes. A large bandwidth can be selected due to the structure of single-loop control. However, this results in poor dynamic transients due to sudden changes of the controller during mode changes. Therefore, inverter control based on indirect current is proposed to improve the dynamic transients by consistently controlling the output voltage under all of the operation modes. A PR-based indirect current control topology is used in this study to maintain the load voltage quality under all of the modes. The design processes of the PR-based triple loop are analyzed in detail while considering the system stability and dynamic transients. The mode transfer techniques are described in detail for both sudden unintentional islanding and islanded mode voltage quality improvements. In addition, they are described using the proposed indirect control structure. The proposed method is verified by the PSiM simulations and laboratory-scale VDER-HILS experiments.

Resource Allocation for Performance Optimization of Interleaved Mode in Airborne AESA Radar (항공기탑재 AESA 레이다의 동시운용모드 성능 최적화를 위한 자원 할당)

  • Yong-min Kim;Ji-eun Roh;Jin-Ju Won
    • Journal of Advanced Navigation Technology
    • /
    • v.27 no.5
    • /
    • pp.540-545
    • /
    • 2023
  • AESA radar is able to instantaneously and adaptively position and control the beam, and this enables to have interleaved mode in modern airborne AESA radar which can maximize situational awareness capability. Interleaved mode provides two or more modes simultaneously, such as Air to Air mode and Sea Surface mode by time sharing technique. In this interleaved mode, performance degradation is inevitable, compared with single mode operation, and effective resource allocation is the key component for the success of interleaved mode. In this paper, we identified performance evaluation items for each mode to analyze interleaved mode performance and proposed effective resource allocation methodology to achieve graceful performance degradation of each mode, focusing on detection range. We also proposed beam scheduling techniques for interleaved mode.

Derivation of the Timing Constraints for Multi-Sampled Multitasks in a Real-Time Control System (다중샘플링 다중작업을 수행하는 실시간제어시스템의 시계수제한성 유도)

  • 이대현;김학배
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.5 no.2
    • /
    • pp.145-150
    • /
    • 1999
  • A real-time control system, composed of the controlled processor and the controller computer(s), may have a variety of task types, some of which have tight timing-constraints in generating the correct control input. The maximum period of those task failures tolerable by the system is called the hard deadline, which depends on not only fault characteristics but also task characteristics. In the paper, we extend a method deriving the hard deadline in LTI system executing single task. An algorithm to combine the deadlines of all the elementary tasks in the same operation-mode is proposed to derive the hard deadline of the entire system. For the end, we modify the state equation for the task to capture the effects of task failures (delays in producing correct values) and inter-correlation. We also classify the type of executing the tasks according to operation modes associated with relative importance of correlated levels among tasks, into series, parallel, and cascade modes. Some examples are presented to demonstrate the effectiveness of the proposed methods.

  • PDF

Load-Adaptive Address Energy Recovery Technique for Plasma Display Panel

  • Lee Jun-Yeong
    • Proceedings of the Korean Society Of Semiconductor Equipment Technology
    • /
    • 2005.05a
    • /
    • pp.192-200
    • /
    • 2005
  • A high speed address recovery technique for AC plasma display panel(PDP) is proposed. By removing the GND switching operation, the recovery speed can be increased and switching loss due to GND switch also becomes to be reduced. The proposed method is able to perform load-adaptive operation by controlling the voltage level of energy recovery capacitor, which prevents increasing inefficient power consumption caused by circuit loss during recovery operation. Thus, th e technique shows the minimum address power consumption according to various displayed images, different from prior methods operating in fixed mode regardless of images. Test results with 50' HD single- scan PDP(resolution : $1366{\times}768$) show that less than 350ns of recovery time is successfully accomplished and about $54\%$ of the maximum power consumption can be reduced, tracing minimum power consumption curves.

  • PDF

New CCM Single Stage PFC Full Bridge Converter (새로운 CCM 단일 전력단 역률보상 풀 브리지 컨버터)

  • Lim, Chang-Seob;Kwon, Soon-Kurl;Cho, Jung-Goo;Song, Doo-Ik
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.986-989
    • /
    • 2002
  • This paper proposes a new single stage power factor correction (PFC) full bridge converter which operates at continuous conduction mode(CCM). The proposed single stage PFC consists of typical zero voltage switching(ZVS) full bridge DC/DC converter, two transformer auxiliary windings, and two small inductors, and two diodes. Neither additional active switch nor any control circuit are added for PFC resulting in very low cost. The proposed converter provides input power factor correction with CCM control and tight output voltage regulation. All switching devices are operated under ZVS with minimum voltage stress. Operation principle and analysis are explained and verified with computer simulation and experimental results on a 1.2kW, 100kHz prototype.

  • PDF

Implementation of a High-Power-Factor Single-Stage Electronic Bal last for fluorescent lamps (전단일전력단을 갖는 고역율 형광등용 전자식 안정기 구현)

  • 서철식;박재욱;김해준;노채균;김동희
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.123-127
    • /
    • 2001
  • In this paper, prototype high-power-factor single-stage electronic ballast for fluorescent lamps is designed and implemented. A new low cost single stage high power factor electronic ballast for fluorescent lamps is based on integration of two-boost converter and LC type high frequency resonant converter. A ballast is obtained by simple construction, because full bridge rectifier diode is eliminated and simple control circuit is applied. Using two boost converter operating positive and negative half cycle respectively at line frequency (60Hz), operation in discontinuous conduction mode performs high power factor. The experimental results Show the good performance as PF 0.99, $A_{THD}$ 15.4%, and CF 1.65 at Output 63.5W.W.

  • PDF