• Title/Summary/Keyword: single-electrode sensor

Search Result 52, Processing Time 0.031 seconds

Development of Single-layer-structured Glucose Biosensor

  • Lee, Young-Tae;Kwon, Min Su
    • Journal of Sensor Science and Technology
    • /
    • v.24 no.2
    • /
    • pp.83-87
    • /
    • 2015
  • In this paper, we fabricated a low-cost glucose sensor with a simpler structure and fabrication process than the existing glucose sensor. The currently used glucose sensor has a three-layer structure with upper, middle, and bottom plates; here, we fabricated a single-layer glucose sensor using only a printing and dispensing process. We successfully fabricated the glucose sensor using a simple method involving the formation of an electrode and insulator layer through a 2- or 3-step printing process on plastic or paper film, followed by the dispensing of glucose oxidase solution on the electrode. Cyclic voltammetry (CV) and cyclic amperometry (CA) measurements were used to evaluate the characteristics of the fabricated single-layer glucose sensor. Also, its sensitivity was analyzed through glucose-controlled blood measurements. Hence, a low-cost single-layer glucose sensor was fabricated with evaluation of its characteristics demonstrating that it has useful application in medicine.

Development of Surface Myoelectric Sensor for Myoelectric Hand Prosthesis

  • Choi, Gi-Won;Moon, In-Hyuk;Sung, So-Young;Lee, Mynug-Joon;Chu, Jun-Uk;Mun, Mu-Seong
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.1268-1271
    • /
    • 2005
  • This paper proposes a compact-sized surface myoelectric sensor for myoelectric hand prosthesis. To fit the surface myoelectric sensor in the socket of the myoelectric hand prosthesis, the sensor should be a compact size. The surface myoelectric sensor is composed of a skin interface and a single processing circuit that are mounted on a single package. Since the skin interface has one reference and two input electrodes, and the reference electrode is located in middle of two input electrodes, we propose two types of sensors with the circle- and bar-shaped reference electrode, but all input electrodes are the bar-shaped. The metal material used for the electrodes is the stainless steel (SUS440) that endures sweat and wet conditions. Considering conduction velocity and median frequency of the myoelectric signal, we select the inter-electrode distance (IED) between two input electrodes as 18mm, 20mm, and 22 mm. The signal processing circuit consists of a differential amplifier with band pass filter, a band rejection filter for rejecting 60Hz power-line noise, amplifiers, and a mean absolute value circuit. We evaluate the proposed sensor from the output characteristics according to the IED and the shape of the reference electrode. From the experimental results we show the surface myoelectric sensor with the 18mm IED and the bar-shaped reference electrode is suitable for the myoelectric hand prosthesis.

  • PDF

The Incremental Delta-Sigma ADC for A Single-Electrode Capacitive Touch Sensor (단일-극 커패시터 방식의 터치센서를 위한 Incremental 델타-시그마 아날로그-디지털 변환기 설계)

  • Jung, Young-Jae;Roh, Jeong-Jin
    • Journal of IKEEE
    • /
    • v.17 no.3
    • /
    • pp.234-240
    • /
    • 2013
  • This paper presents an incremental delta-sigma analog-to-digital converter (ADC) for a single-electrode capacitive touch sensor. The second-order cascade of integrators with distributed feedback (CIFB) delta-sigma modulator with 1-bit quantization was fabricated by a $0.18-{\mu}m$ CMOS process. In order to achieve a wide input range in this incremental delta-sigma analog-to-digital converter, the shielding signal and the digitally controlled offset capacitors are used in front of a converter. This circuit operated at a supply voltage of 2.6 V to 3.7 V, and is suitable for single-electrode capacitive touch sensor for ${\pm}10-pF$ input range with sub-fF resolution.

Simultaneous measurement of oxygen permeability by using of multi-functional oxygen electrode (다기능 산소전극에 의한 산소투과특성 동시측정)

  • 이동희;정진휘;유형풍;김태진
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.532-535
    • /
    • 2000
  • We have fabricated a sensor system for on-line monitoring the oxygen permeability and diffusivity of six different polymer films using the miniaturized 6 cathode(Ag)-single anode(Ag/AgCl) type hexagonal oxygen electrode. This system consists of multiple input front-end electronics, signal conditioning circuit using the embedded microcontroller 80C196KC, PC interface circuit and PC with the OS for microcontroller and the operating program for this system. The digital low-[ass filter was programmed and the simulated filter characteristics were enough to eliminate the noise from sensor signal. According to the experimental results, the linearity coefficients of the output voltage to oxygen partial pressure for each sensor electrode of six cathode type oxygen sensor are 0.998, 0.997, 0.998, 0.997, 0.997, 0.997 respectively, and the response times are all within 4 minutes.

  • PDF

A Study on the Reference Electrode for Al Concentration Sensor in Zinc Galvanizing Melt (용융아연 도금욕중 Al농도 센서의 기준전극에 대한 연구)

  • Jung, W.G.;Jung, S.H.
    • Korean Journal of Materials Research
    • /
    • v.16 no.2
    • /
    • pp.129-136
    • /
    • 2006
  • In order to get basic information on the reference electrode material for the long life Al concentration sensor in zinc galvanizing melt, the workability and stability of fluorine potential cell with $CaF_2$ single crystal electrolyte were examined carefully at constant temperature for six kinds of reference materials (Zn, Sn, Cd, Bi, Pb, Al-Sn alloy + fluorides). Good workability and stability of the sensor were found in sensor with $Bi+BiF_3$ reference electrode. The Al sensor with $Bi+BiF_3$ reference electrode was assembled and was tested in Zn-Al melt with different Al concentration. The EMF was changed rapidly with the change of Al concentration and was stabilized in a short time. Thus the response of EMF was satisfactory for $CaF_2$ sensor. The correlationship between EMF from the sensor and logarithm of Al concentration has been derived from the least square regression method. E/mV=57.515log[wt% Al]+1883.3 R=0.9717 ($0.013{\leq}[wt% Al]{\leq}0.984$) The EMF from Al sensor was increased linearly against logarithm of [wt% Al]. The fluorine potential of Zn-Al melt was also calculated to be in the range of $10^{-60}{\sim}10^{-61}$ Pa for the present experiemental condition.

Development of low power type sensor for the DO concentration measurement by clark electrode (Clark전극에 의한 DO 농도측정을 위한 절전형 센서개발에 관한 연구)

  • 이동희
    • Electrical & Electronic Materials
    • /
    • v.8 no.3
    • /
    • pp.254-260
    • /
    • 1995
  • A method is described for the design and fabrication of the sensor interface circuits on the Clark electrodes for the dissolved oxygen(DO). The discussion includes a method for the +5 V single-supply driving for the sensor circuits, which has low power comsumption for the front-end electronics. DO probe under test is composed of the Clark electrode with silver anode, gold cathode and the electrolyte of half saturated KCI solution and the FEP teflon memtrance for the oxygen penetration. Typical polarograms for the DO probes by using this sensor circuit reveals high accuracy over 99% of the I to V conversion. Partial pressure of oxygen obtained from the polarograms are well suited to the results calculated. It is expected that the proposed sensor circuits can be utilized into the customized IC for the battery-driven small-size DO meters.

  • PDF

Characteristics and Fabrication of Micro Gas Sensor with Single Electrode (단일전극을 가진 마이크로 가스센서의 제작 및 특성)

  • Song, Kap-Duk;Bang, Yeung-Il;Lee, Sang-Mun;Lee, Yun-Su;Choi, Nak-Jin;Joo, Byung-Su;Seo, Moo-Gyo;Huh, Jeung-Soo;Lee, Duk-Dong
    • Journal of Sensor Science and Technology
    • /
    • v.11 no.6
    • /
    • pp.350-357
    • /
    • 2002
  • Micro gas sensor with single electrode was proposed for improving stability and sensitivity. Generally, metal oxide gas sensors have two electrodes for heating and sensing. This fabricated new type sensor have only a single electrode by forming a sensing material onto heating electrode. Pt as a heating and sensing electrode was sputtered on glass substrate and a $SnO_2$ sensing material was thermally evaporated on Pt electrode. $SnO_2$ was patterned by lift-off process and then thermally oxidized in $O_2$ condition for 1 hr., $600^{\circ}C$. The size of fabricated sensor was $1.9{\times}2.1\;mm^2$. As a result of CO gas sensing characteristics, this sensor showed 100 mV change for 1,000 ppm and linearity for wide range($0{\sim}10,000\;ppm$) of gas concentrations. And the sensor shows a good recovery characteristics of 1% deviation compared to initial resistance.

Development of Surface Myoelectric Sensor for Myoelectric Hand Prosthesis (근전의수용 소형 표면 근전위 센서의 개발)

  • Choi, Gi-Won;Sung, So-Young;Moon, Inhyuk
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.42 no.6
    • /
    • pp.67-76
    • /
    • 2005
  • This paper proposes a compact-sized surface myoelectric sensor for the myoelectric hand prosthesis. To fit the surface myoelectric sensor in the socket for the myoelectric hand prosthesis, the sensor should be a compact size. The surface myoelectric sensor is. composed of a skin interface and a single processing circuit that are mounted on a single package. The skin interface has one reference and two input electrodes, and the reference electrode is located in the center of two input electrodes. In this paper we propose two types of sensors with the circle- and bar-shaped reference electrode, but all input electrodes are the bar-shaped. The metal material of the electrodes is the stainless steel (SUS440) that endures sweat and wet conditions. Considering the conduction velocity and the median frequency of the myoelectric signal, we select the inter-electrode distance (IED) between two input electrodes as 18mm, 20mm, and 22 mm. The signal processing circuit consists of a differential amplifier with a band pass filter, a band rejection filter for rejecting 60Hz power-line noise, amplifiers, and a mean absolute value circuit. We evaluate the proposed sensor from the output characteristics according to the IED and the shape of the reference electrode. From the experimental results we show the surface myoelectric sensor with the 18mm IED and the bar-shaped reference electrode is suitable for the myoelectric hand prosthesis.

Enhancement of Electrocatalytic Activity upon the Addition of Single Wall Carbon Nanotube to the Redox-hydrogel-based Glucose Sensor

  • Kim, Suk-Joon;Quan, Yuzhong;Ha, Eunhyeon;Shin, Woonsup
    • Journal of Electrochemical Science and Technology
    • /
    • v.12 no.1
    • /
    • pp.33-37
    • /
    • 2021
  • In electrochemical glucose sensing, the enhancement of the sensitivity and the response time is essential in developing stable and reliable sensors, especially for continuous glucose monitoring. We developed a method to increase the sensitivity and to shorten the response time for the sensing upon the appropriate addition of single wall carbon nanotube onto the osmium polymer-based hydrogel electrode. Also, the background stabilization is dramatically enhanced.

Capacitive Touch Sensor Pixel Circuit with Single a-InGaZnO Thin Film Transistor (단일 a-InGaZnO 박막 트랜지스터를 이용한 정전용량 터치 화소 센서 회로)

  • Kang, In Hye;Hwang, Sang Ho;Baek, Yeong Jo;Moon, Seung Jae;Bae, Byung Seong
    • Journal of Sensor Science and Technology
    • /
    • v.28 no.2
    • /
    • pp.133-138
    • /
    • 2019
  • The a-InGaZnO (a-IGZO) thin film transistor (TFT) has the advantages of larger mobility than that of amorphous silicon TFTs, acceptable reliability and uniformity over a large area, and low process cost. A capacitive-type touch sensor was studied with an a-IGZO TFT that can be used on the front side of a display due to its transparency. A capacitive sensor detects changes of capacitance between the surface of the finger and the sensor electrode. The capacitance varies according to the distance between the sensor plate and the touching or non-touching of the sensing electrode. A capacitive touch sensor using only one a-IGZO TFT was developed with the reduction of two bus lines, which made it easy to reduce the pixel pitch. The proposed sensor circuit maintained the amplification performance, which was investigated for various drive conditions.