• Title/Summary/Keyword: single pulse

Search Result 828, Processing Time 0.026 seconds

Scintillation properties of CsSrCl3 single crystal (CsSrCl3 단결정의 섬광특성)

  • Doh, Sih-Hong;Kim, Sung-Hwan;Ra, Se-Jin;Kim, Hong-Joo;Kang, Hee-Dong;Oh, Moon-Young
    • Journal of Sensor Science and Technology
    • /
    • v.16 no.5
    • /
    • pp.337-341
    • /
    • 2007
  • $CsSrCl_{3}$ crystal was grown using Czochralski method from equimolar mixture of CsCl and $SrCl_{2}$. The spectrum range of the luminescence excited by 205 nm of wavelength was about $280{\sim}550$ nm, and its peak emission appeared at 343 nm. The luminescence decay curve of the $CsSrCl_{3}$ revealed two exponential components with time constants of 60 ns and 700 ns. The energy resolution for $^{137}Cs$ 662 keV ${\gamma}$-ray was 10.3 %. The pulse shape was linear at high energy, but some deviation existed in the low energy region.

Long Range Active Acoustic System for Fish Finding (장거리 능동 어탐의 연구)

  • Jang, Ji-Won;Park, Jong-Man;Lee, Un-Hui
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.24 no.1
    • /
    • pp.1-6
    • /
    • 1988
  • For the purpose of making the detection range of fish detection system more longer and computerizing the system a parametric sound source, a timer and a digitizing circuit for the Apple II computer have been studied. The parametric sound of 5 KHz generated by passing AND gate two signals from carrier signal generator of 200KHz with modulator of 5KHz. This parametric acoustic source of 5KHz difference frequency had more higher directional resolution of 10 degrees than single frequency sound of 200KHz. Peripheral interface adaptor MC 6821 was adopted for interfacing to the Apple II personal computer. The timer consisted of six decade binary coded decimal counters (74 LS 190), and the digitizing circuit consisted of a sample and hold (LF 398) and an A/D converter(ADC 0808). The timer with 10KHz clock pulse had the measuring time from 0.1msec to 100sec. This time measuring range was satisfactory for the aim of the fish finding acoustic system.

  • PDF

Research on Anti-Reader Collision Protocols for Integrated RFID-WSNs

  • Ko, Doo-Hyun;Kim, Bum-Jin;An, Sun-Shin
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.4 no.5
    • /
    • pp.776-796
    • /
    • 2010
  • Integrated RFID-WSNs (wireless sensor networks) have recently been researched to provide object identities, sensing information, mobile service, and network functionalities. In integrated RFID-WSNs, the reader collision is one of the critical problems. Above all, due to the absence of universally applicable anti-collision protocols and the channel capture phenomenon, the medium access control protocols in integrated RFID-WSNs suffer from reader collision and starvation problems. In this paper, we propose an efficient MAC protocol, called EMP, to avoid the above problems in integrated RFID-WSNs. EMP is a CSMA-based MAC protocol which is compatible with sensor networks operating on integrated nodes which consist of an RFID reader and a senor node. EMP resolves not only the reader collision problem, but also the starvation problem using a power control mechanism. To verify the performance of EMP, we compared it with other anti-reader collision MAC protocols using simulations. As a result, the performance of EMP showed improvements in throughput, system efficiency, and energy consumption compared to the single data channel protocols (CSMA/CA, Pulse, and DiCa) in dense deployment environments.

A Data Acquisition System based upon a Single-board Microcomputer (단일보드 마이크로 컴퓨터를 이용한 자료(資料) 수집장치(蒐集裝置))

  • Choi, C.H.
    • Journal of Biosystems Engineering
    • /
    • v.14 no.4
    • /
    • pp.221-228
    • /
    • 1989
  • A data acquisition system was designed to measure the forces on a rolling coulter in three coordinated directions, angular velocity of the coulter and travel speed of a soil bin. The data acquisition system consisted of a dynamometer, speed transducers, a signal conditioner, an inter-face board, an Aim-65 microcomputer and a digital data recorder. Strain gages were attached on the surface of the dynamometer and connected to form three Wheatstone bridges, which measure the draft force, the vertical force and the side force on the coulter. An interaction among three dimensional forces was found during the calibration. A matrix procedure was used to correct the forces for this interaction. Rotary shaft encoders were mounted on the coulter and on the soil bin drive to measure the angular velocity of the coulter and the travel speed of the soil bin. The angular velocity and the travel speed were computed by counting the number of pulse signals from the rotary shaft encoders every 0.2 second. The digital signals from the rotary shaft encoders were connected to counters and the analog signals from the dynamometer, after passing through the signal conditioner, were connected to the A/D converter. The microcomputer programs, written in assembly language, were developed to read signals from the transducers, convert them to actual unit, display them upon request and record them on a sigital tape every 0.2 second.

  • PDF

Ferroelectric and Magnetic Properties of BiFeO3 Thin Films Deposited on SrTiO3 Substrate (SrTiO3기판 위에 증착한 BiFeO3박막의 강유전 및 자기적 특성)

  • Lee, Eun-Gu;Kim, Sun-Jae;Lee, Jae-Gab
    • Journal of the Korean Ceramic Society
    • /
    • v.45 no.6
    • /
    • pp.358-362
    • /
    • 2008
  • $BiFeO_3$ films were hetero-epitaxially grown on $SrTiO_3$ substrate with a various orientation by pulse laser deposition. $BiFeO_3$ films grown on (111) $SrTiO_3$ substrate have a rhombohedral structure, identical to that of single crystals. On the other hand, films grown on (110) or (001) $SrTiO_3$ substrate are monoclinically distorted from the rhombohedral structure due to the epitaxial constraint. The easy axis of spontaneous polarization is close to [111] for the variously oriented films. Dramatically enhanced polarization and magnetization have been found for $BiFeO_3$ thin films grown on $SrTiO_3$ substrate comparing to that of $BiFeO_3$ crystals. The results are explained in terms of an epitaxially-induced transition between cycloidal and homogeneous spin states, via magneto-electric interactions.

A study on measurement apparatus for ferroelectricity in ferroelectrics (강유전특성 측정장치의 연구개발)

  • Lee, Chang-Hun;Kang, Dae-Ha
    • Proceedings of the KIEE Conference
    • /
    • 1997.07d
    • /
    • pp.1317-1319
    • /
    • 1997
  • This paper is to study and develope a measurement apparatus for ferroelectricity. The apparatus consists of wave generation part, high voltage amplifier part, measurement part, data acquisition part and the related controll circuits. Single or double excitation wave is digitalized and sent to the external RAM of wave generation part by personal computer. These datas saved in the RAM are converted to analog excitation wave through D/A converter. The frequency of excitation wave is depend on the read-out speed of the RAM by clock pulse. Such generated wave is applied to high voltage amplifier as a input voltage. The output of high voltage amplifier is applied to ferroelectrics and the response is obtained from the charge amplifier of measurement part. The response is sampled and converted to digital datas through AID converter. These digital datas are automatically saved in the external RAM of acquisition part. The computer takes the digital datas and calculates the electric displacement D, the electric field and the dielectric constant $\varepsilon$. We tested for PZT ceramic sample and could observed the D-E hysteresis lops and ${\varepsilon}_s$-E hysteresis loops with good forms.

  • PDF

A Novel Modulation Scheme and a DC-Link Voltage Balancing Control Strategy for T-Type H-Bridge Cascaded Multilevel Converters

  • Wang, Yue;Hu, Yaowei;Chen, Guozhu
    • Journal of Power Electronics
    • /
    • v.16 no.6
    • /
    • pp.2099-2108
    • /
    • 2016
  • The cascaded multilevel converter is widely adopted to medium/high voltage and high power electronic applications due to the small harmonic components of the output voltage and the facilitation of modularity. In this paper, the operation principle of a T-type H-bridge topology is investigated in detail, and a carrier phase shifted pulse width modulation (CPS-PWM) based control method is proposed for this topology. Taking a virtual five-level waveform achieved by a unipolar double frequency CPS-PWM as the output object, PWM signals of the T-type H-bridge can be obtained by reverse derivation according to its switching modes. In addition, a control method for the T-type H-bridge based cascaded multilevel converter is introduced. Then a single-phase T-type H-bridge cascaded multilevel static var generator (SVG) prototype is built, and a repetitive controller based compound current control strategy is designed with the DC-link voltage balancing control scheme analyzed. Finally, simulation and experimental results validate the correctness and feasibility of the proposed modulation method and control strategy for T-type H-bridge based cascaded multilevel converters.

Tc-To Method in Measurement of Concrete Crack (Tc-To법에 의한 콘크리트 균열측정)

  • 민정기
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.39 no.3
    • /
    • pp.108-114
    • /
    • 1997
  • Concrete is said to have a high degree of extensibility when it is subjected to large deformations without cracking. The cracking behavior of concrete in the field may even be more complex. For example, in mass concrete compressive stresses are developed during the very early period when temperatures are rising, and the tensile stresses do not develop until at a later age when the temperature begins to decline. Actual cracking and failure depend on the combination of factors and indeed it is rarely that a single adverse factor is responsible for cracking of concrete. The importance of cracking and the minimum width at which a crack is considered significant depend on the conditions of exposure of the concrete. The ultrasonic pulse measurements can be used to detect the development of cracks in structures such as dams, and to check deterioration due to frost or chemical action. An estimate of the depth of a crack visible at the surface can be obtained by measuring the transit times across the crack for two different arrangements of the transducers placed on the surface. In this paper, the concrete cracks that artificially introduced crack width is 1 and 2mm, crack depth is 2, 4, 6, 8cm were measured by Tc-To Method In consequence, the measured depth was increased with increase of measuring distance from concrete crack. The most reliable results were shown when the introduced crack width was 1mm, and the measuring distance was 10cm from concrete crack.

  • PDF

Development of a Patient Monitoring System Overall Architecture and Specifications (환자모니터링시스템의 개발 : 전체구조 및 기본사양)

  • 우응제;박승훈
    • Journal of Biomedical Engineering Research
    • /
    • v.18 no.1
    • /
    • pp.17-24
    • /
    • 1997
  • We have developed a patient monitoring system including module-based bedside monitors, interbed network, central stations, clinical workstations, and DB servers. A bedside monitor with a color LCD can accommodate up to 3 module cases and 21 different modules. Six different physiological parameters of ECG, respiration, invasive blood pressure, noninvasive blood pressure, body temperature, and arterial pulse oximetry with plethysmoyaph are provided as parameter modules. In a single bedside monitor, modules and a module controller communicate with IMbps data rate through an intrabed network based on RS-485 and HDU protocol. At the same time, it communicates with other bedside monitors and central stations through interbed network based on 1 OMbps Ethernet and TCP/IP protocol. Central stations using 20" color CRT monitors can be connected with many bedside monitors and they display 18 channels of waveforms simultaneously. Clinical workstations are used mainly for the review of patient datE In order to accommodate more advanced data management capabilities such as 24-hour full disclosure, we have developed a relational database server dedicated to the patient monitoring system. Software for bedside monitor, central station, and clinical workstation fully utilizes graphical user interface techniques and all functions are controlled by a rotate/push button on the bedside monitor arid a mouse on the central station and clinical workstation. The entire system satisfies the requirements of AAMI and ANSI standards in terms of electrical safety and performances.nces.

  • PDF

Pseudo Optical PAM-N Signal Using Externally Modulated Lasers

  • Huh, Joon Young;Lee, Joon Ki;Kang, Sae-Kyoung;Lee, Jyung Chan
    • ETRI Journal
    • /
    • v.37 no.6
    • /
    • pp.1120-1128
    • /
    • 2015
  • We propose a pseudo optical N-level pulse-amplitude modulation (PO PAM-N) signal using a few externally-modulated lasers (EMLs) operating at different wavelengths, which is suitable for upgrading the transmission speed over an optical link of < 10 km single-mode fiber with low-cost components. To compare a PO PAM-N signal with that of a standard optical PAM-N signal, we perform experiments for evaluating the performance of a 51.56-Gb/s PO PAM-4 signal and standard 51.56-Gb/s optical PAM-4 signal. The receiver sensitivity (at $BER=10^{-5}$) of the PO PAM-4 signal is 1.5 dB better than the receiver sensitivity of a standard optical PAM-4 signal. We also investigate the feasibility of PO PAM-N (N = 4, 8, and 16) signals operating at 103.12 Gb/s, considering relative intensity noise, timing jitter, extinction ratio (ER) of EMLs, and dispersion. From the results, a PO PAM-8 signal performs better than PO PAM-4 and PO PAM-16 signals at 103.12 Gb/s. Finally, we suggest a timing control method to suppress the effect of dispersion in a PO PAM-N signal. We show that the tolerance to dispersion of a 103.12-Gb/s PO PAM-8 signal can be improved to ${\pm}40ps/nm$ by applying a proposed scheme.