• Title/Summary/Keyword: single point contact

Search Result 73, Processing Time 0.025 seconds

Contact Stress Analysis of a Pair of Mating Spur Gears (스퍼기어의 접촉응력 해석)

  • Lee, Jin-Hwan;Lee, Dong-Hyong;Lee, Kwon-Hee
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.9 no.4
    • /
    • pp.59-65
    • /
    • 2010
  • This paper presents the study on the contact stress analysis of a pair of mating spur gears during rotation. Contact stress analysis is performed between two spur gear teeth at different contact positions during rotation. An example is presented to investigate the variation of contact stress on a pair of mating gears with contact positions. The variation of contact stress during rotation is compared with the contact stress at lowest point of single tooth contact(LPSTC) and AGMA Equation for contact stress. The results show that contact stress varies along the contact position and gets maximum values in the beginning and end of the contact. In this study, the gear design considering the contact stress on a pair of mating gears is more severe than that of AGMA standard.

Contact Stress Analysis of Helical Gear for Turbo Blower (터보블로워용 헬리컬 기어의 접촉응력 해석)

  • Hwang, Seok-Cheol;Lee, Dong-Hyong;Park, Young-Chul;Lee, Kwon-Hee
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.10 no.2
    • /
    • pp.90-95
    • /
    • 2011
  • This paper presents the study on the contact stress analysis of a pair of mating helical gears for turbo blower during rotation. Turbo blowers need high speed rotation of impeller in structure and high rate gear ratio. The use of helical gear indicated that noise was an important problem when the application involves high speeds and large power transmission. An example is presented to investigate the variation of contact stress on a pair of mating gears with contact positions. The variation of contact stress during rotation is compared with the contact stress at the lowest point of single tooth contact(LPSTC) and AGMA Equation for contact stress. In this study, the gear design considering the contact stress on a pair of mating gear is more severe than that of AGMA standard.

Development of On-machine Measurement System utilizing a Capacitive-type Sensor (정전용량형 센서를 이용한 기상계측시스템의 개발)

  • 김건희;박순섭;박원규;원종호
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.391-395
    • /
    • 2002
  • This paper described about the ultra-precision profile measurement of aspheric surfaces using contact probing technique. A contact probe has been designed as a sensing device to obtain measuring resolutions in nanometer regime utilizing a leaf spring mechanism and a capacitive-type sensor. The contact probe is attached on the z-axis during measurement while aspheric objects are supported on the single point diamond turning machine(SPDTM). The machine xz-axis motions are monitored by a set of two orthogonal plane mirror type laser interferometers. Experimental results show that the contact probing technique developed of On-machine Measurement System in this investigation is capable of providing a repeatability of 20 nanometers with a $\pm$20 uncertainty of 300 nanometers.

  • PDF

Direct-contact heat transfer of single droplets in dispersed flow film boiling: Experiment and model assessment

  • Park, Junseok;Kim, Hyungdae
    • Nuclear Engineering and Technology
    • /
    • v.53 no.8
    • /
    • pp.2464-2476
    • /
    • 2021
  • Direct-contact heat transfer of a single saturated droplet upon colliding with a heated wall in the regime of film boiling was experimentally investigated using high-resolution infrared thermometry technique. This technique provides transient local wall heat flux distributions during the entire collision period. In addition, various physical parameters relevant to the mechanistic modelling of these phenomena can be measured. The obtained results show that when single droplets dynamically collide with a heated surface during film boiling above the Leidenfrost point temperature, typically determined by droplet collision dynamics without considering thermal interactions, small spots of high heat flux due to localized wetting during the collision appear as increasing Wen. A systematic comparison revealed that existing theoretical models do not consider these observed physical phenomena and have lacks in accurately predicting the amount of direct-contact heat transfer. The necessity of developing an improved model to account for the effects of local wetting during the direct-contact heat transfer process is emphasized.

Soft tissue reactions around implant-supported single-tooth replacements in the maxillary anterior region (상악 전치부 단일 임플란트 지지 수복금관의 주변 연조직반응의 단면적 연구)

  • Chang, Moon-Taek
    • Journal of Periodontal and Implant Science
    • /
    • v.28 no.2
    • /
    • pp.321-337
    • /
    • 1998
  • The aims of this study were firstly to investigate soft tissue reactions around single implant-supported crowns and secondly to compare soft tissue dimensions and conditions of the crowns in relation to interdental papillae, and lastly to investigate patients'esthetic satisfaction with their single implant-supported crowns according to the interdental papillae presence/absence. Twenty-nine patients (41 implants) whose single missing tooth in the maxillary anterior region had been replaced by single implant-supported crown participated for the study and various variables of soft tissue conditions, dimensions and crown dimensions were measured around the single implant-supported crowns at clinical examination and from study models and slides. The results showed that the soft tissue conditions around the single implantsupported crowns were similar to those around implants used for partially or totolly edentulous patients. Except for the high frequency of bleeding on probing, all other parameters revealed healthy conditions. The buccal sites of the crown had a shallow pocket comparing with other sites. At all sites of the crown, similar status of little inflammation was found. Mesial sites and central-incisor positioned implantsupported crowns had lower contact point position than distal sites and lateral-incisor positioned crowns, respectively. Mucositis index, probing depth and contact point position were significantly correlated with papillae index(p < 0.05). More inflammation and lower contact point position were found at the implant-supported crown with no interdental space than that with interdental space. Patients showed high esthetic satisfaction regardless of interdental space presence. The result indicated that, despite of their submucosal crown margins, single implantsupported crowns have soft tissue conditions as good as other implants used for the treatment of the different types of edentulism and a clinician can manipulate interdental papilla height by modifying crown shapes within the limits of not violating total esthetics.

  • PDF

A Study on the Phoneme Segmentation of Handwritten Korean Characters by Local Graph Patterns on Contacting Points (접촉점에서의 국소 그래프 패턴에 의한 필기체 한글의 자소분리에 관한 연구)

  • 최필웅;이기영;구하성;고형화
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.30B no.4
    • /
    • pp.1-10
    • /
    • 1993
  • In this paper, a new method of phoneme segmentation of handwritten Korean characters using the local graph pattern is proposed. At first, thinning was performed before extracting features. End-point, inflexion-point, branch-point and cross-point were extracted as features. Using these features and the angular relations between these features, local graph pattern was made. When local graph pattern is made, the of strokes is investigated on contacting point. From this process, pattern is simplified as contacting pattern of the basic form and the contacting form we must take into account can be restricted within fixed region, 4therefore phoneme segmentation not influenced by characters form and any other contact in a single character is performed as matching this local graph pattern with base patterns searched ahead. This experiments with 540 characters have been conducted. From the result of this experiment, it is shown that phoneme segmentation is independent of characters form and other contact in a single character to obtain a correct segmentation rate of 95%, manages it efficiently to reduce the time spent in lock operation when the lock.

  • PDF

Near Visual Performance of Multifocal Contact Lenses in University Students (대학생에서 멀티포컬 소프트콘택트렌즈의 근거리 시기능 유용성)

  • Jong, Woo-Cheol;Kim, Soo-Hyun;Kim, Jai-Min
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.1
    • /
    • pp.51-60
    • /
    • 2011
  • Purpose: This study was to investigate visual performance and subjective satisfaction with multifocal soft contact lenses at near works in university students. Methods: In a cross-over study design, 26 students (6 male, 20 female) who did not have any ocular disorder with at least 20/20(1.0) binocular vision were fitted with singlevision lenses (SofLens$^{TM}59$, Bausch + Lomb Co. USA) or multifocal lenses (SofLens Multifocal, Bausch + Lomb Co. USA). After 2 weeks, visual performance assessments included visual acuity, stereoacuity and contrast sensitivity function at distance and near. Near point of accommodation, accommodative facility, near point of convergence, vergence facility and near range of clear vision at near were examined. Students' satisfaction and preference were measured using survey questionaries. Results: Subjects maintained at least 20/20 binocular vision with multifocal and single-vision lenses at distance and near. There was no difference between multifocal and single-vision lenses in stereoacuity, contrast sensitivity function and vergence facility at far and near. The near point of accommodation, accommodative facility, near point of convergence and the near range of clear vision with multifocal lenses were better than single-vision lenses. On the survey questionaries, subjects reported that they preferred and satisfied with multifocal lenses with near works, and single-vision lenses with distance works. Conclusions: The majority of university students preferred multifocal to single vision lenses because multifocal lenses provided better visual performance at near works. This study suggests that multifocal lens is helpful for young adult in prolonged near works.