• Title/Summary/Keyword: single pipe

Search Result 255, Processing Time 0.028 seconds

Field Survey on the Shading Structure and Environmental Management for Ginseng Cultivation (인삼재배시설의 구조 및 환경관리 실태조사)

  • Nam, Sang-Woon
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2002.10a
    • /
    • pp.65-68
    • /
    • 2002
  • This study was conducted to secure the structural safety and to build fundamental data for development of controlled environment facilities in ginseng cultivation. Shading structures of ginseng cultivation were classified with materials, structural forms, and detailed setups. They are wood or steel pipe, single or multi span, and frame or cable type. For structures having representative forms and dimensions, modeling for structural analysis was builded by SAP2000. And there was almost no farm carrying out the environmental management specially.

  • PDF

The Electric Generation by Solar Energy (태양에너지 발전에 관한 연구)

  • Kim, Geun-Hui;Yang, Jun-Muk;Jeon, Seong-Sik
    • Solar Energy
    • /
    • v.1 no.1
    • /
    • pp.1-11
    • /
    • 1981
  • The electric generation system by solar energy was built which is composed of $10m^2$ reflector, parabolic mirror and the absorbers. The absorber(I) is a single iron pipe and the absorber (II) contains seven small iron pipes. The ratio of the area of the reflectors to that of the absorber is around 99.4-440. The absorber(II) is more efficient in power than (II) by 5.6 percent. The steam power efficiency of the absorber (II) is 25 percent in this experiments and 20 percent efficiency would be expected for 80.000 Kilowatts.

  • PDF

Single and Two-Phase Flow Pressure Drop for CANFLEX Bundle

  • Park, Joo-Hwan;Jun, Ji-Sun;Suk, Ho-Chun;Dimmick, G.R.;Bullock, D.E.
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05a
    • /
    • pp.532-537
    • /
    • 1998
  • Friction factor and two-phase flow frictional multiplier for a CANFLEX bundle are newly developed and presented in this paper. CANFLEX as a 43-element fuel bundle has been developed jointly by AECL/KAERI to provide greater operational flexibility for CANDU reactor operators and designers. Friction factor and two-phase flow frictional multiplier have been developed by using the experimental data of pressure drops obtained from two series of Freon-l34a (R-134a) CHF tests with a string of simulated CANFLEX bundles in a single phase and a two-phase flow conditions. The friction factor for a CANFLRX bundle is found to be about 20 % higher than that of Blasius for a smooth circular pipe. The pressure drop predicted by using the new correlations of friction factor and two-phase frictional multiplier are well agreed with the experimental pressure drop data of CANFLEX bundle within ${\pm}\;5\;%$ error.

  • PDF

A Study of Interpolation Methods for the Water Hammer Analysis using the Method of Characteristics (특성선 방법을 이용한 관망 수격현상 해석의 보간방법연구)

  • Jung, Bong Seog;Kim, Chu In;Kim, Sang Hyun;Park, Nam Sik
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.2
    • /
    • pp.363-373
    • /
    • 2000
  • It is necessary to employ the interpolation technique to resolve problems, which are associated with the characteristic locus in time-distance space, in the unsteady analysis of pipe flow. Various interpolation methods such as linear timeline interpolation, linear spaceline interpolation, wave speed adjustment, cubic spaceline interpolation and cubic timeline interpolation have been suggested and tested to investigate the interpolation error. Performance of various interpolation techniques was evaluated both a single pipeline and a complex one. The range of error was calculated as the courant number varied between 0 and 1 in a single pipeline. Reorganization of computational element and proper selection of interpolation method are found to be prerequisites for the effective computation of unsteady analysis.

  • PDF

Physical Properties of High Performance Multilayered PVC Pipe (고성능 다층 PVC pipe의 물성)

  • Shin, Yong-Jin;Ryang, Kyung-Seung;Kim, Sung-Hyun
    • Applied Chemistry for Engineering
    • /
    • v.10 no.5
    • /
    • pp.711-717
    • /
    • 1999
  • A multilayer-structure material containing ductile and brittle layer simultaneously was examined and compared with a single layer material using fracture mechanical properties. We found that impact strength of multilayer structure material was considerably higher than single layer's and toughness was enhanced by about two times or higher in similar glass transition temperature($T_g$) region and the same dimension. The superposition principle of impact pulse was used for interpretation of kinetic stress wave as a high-velocity crack proceeds in the plastic. It was understood that the optimum condition of ductile/brittle thickness ratio could be designed in the final toughness enhancement of multilayer.

  • PDF

The control of poly-grain and internal cavities for high-quality $CaF_2$ single crystal growth of 6inch in diameter (고품질의 직경 6 inch 형석($CaF_2$)단결정 성장을 위한 poly-grain 및 내부 cavity제어)

  • Seo, Soo-Hyung;Joo, Kyoung;Auh, Keun-Ho
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.8 no.4
    • /
    • pp.550-554
    • /
    • 1998
  • We suggested the new method of thermal screen in Bridgman-Stockbarger method to control the polygrain, the internal cavities and solid-liquid (SL) interface. $CaF_2$ single crystal of 6 inch was grown perfectly when we adopted to use a graphite pipe and a ceramic warmer in the conditions of growth rate 2 mm/hr, vertical temperature of $14^{\circ}C$ for freezing and temperature of $1324^{\circ}C$ at conical tip of crucible. The light scattering phenomena occurred by internal cavities were controlled as decreasing the freezing rate to 2 mm/hr and/or as adopting the rotation of melt (7 rpm).

  • PDF

An Exprimental Study on the Heat Transfer Performance in a Fluidized Bed Double Pipe Heat Exchanger (수직이중관식(垂直二重管式) 유동층형(流動層形) 열교환기(熱交換器)의 전열성능(傳熱性能)에 관한 실험적(實驗的) 연구(硏究))

  • Yoo, Ji-Oh;Seo, Jeong-Yun
    • Solar Energy
    • /
    • v.14 no.2
    • /
    • pp.39-50
    • /
    • 1994
  • Experiments have been conducted to measure the heat transfer coefficient and pressure drop in fluidized bed double pope heat exchangers with smooth tube and longitudinal finned tube. The effect of particle size(alumina beads; do=0.41, 0.54, 0.65, 0.77 mm) and static bed height on the heat transfer coefficient has been evaluated in terms of pumping power. The heat transfer coefficient for the smooth tube and finned tube heat exchangers has been compared with single phase double pipe heat exchanger. Results show that the heat transfer coefficients for the finned tube in $2.96{\sim}3.45$ times higher than the smooth tube. The heat transfer coefficients for the fluidized bed heat exchanger is higher than the single phase heat exchanger for the most of pumping power range tested. The maximum increase in the heat transfer coefficient for fluidized bed is 91.3% for the smooth tube and 127.1% for the finned tube.

  • PDF

A study on the acoustic performance of a silencer according to the change of properties of absorbing material (흡음재 물성치 변화에 따른 소음기 음향성능 연구)

  • Lee, Yongbeom;Yang, Haesang
    • The Journal of the Acoustical Society of Korea
    • /
    • v.40 no.4
    • /
    • pp.278-289
    • /
    • 2021
  • In this study, the acoustic performance of a dissipative silencer used in the ship with excellent performance compared to its size was predicted and analyzed using a numerical analysis method to reduce the pipe noise. To this end, the performance of the single expansion chamber-shaped silencer was verified using experimental and numerical analysis methods. The acoustic performance of the silencer was expressed using the Transmission Loss (TL), an indicator of its own performance, and the result was derived using the two-load method, which measured by changing the impedance at the end of the pipe. For the numerical analysis method, a general-purpose finite element analysis program was used, and the Delany-Bazley-Miki model with the flow resistivity of the sound absorbing material as an input parameter was applied. Finally, we compared the experimental and simulated results for each of the acoustic performances of the single expansion type and the dissipative silencer to confirm the consistency of the results, and predicted and analyzed the simulation results for four cases according to the properties of the sound absorbing material.

Experimental Study on the Calibration of Bi-directional High Pressure Pile Load Test (양방향 고유압 말뚝재하시험장치의 보정에 관한 실험적 연구)

  • Choi, Yongkyu
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.5C
    • /
    • pp.303-311
    • /
    • 2008
  • In the case of bi-directional high pressure pile load test with double-acting jack, the shortcomings of bi-directional pile load test with single-acting jack could be solved, low-cost of test could be sure, the limits of loading capacity could be overcome and quality assurance of service plie could be confirmed. In this study, to confirm the stability, the reliability and the application of bi-directional high pressure pile load test with double-acting jack, the calibration test for high pressure oil jacks, the length of high pressure hose and tunable high pressure pipe system were performed. As a result, credibility was very high because the reliability of test results was approached at about 1.0.

A Study on the Drag Reduction with Polymer Additives (고분자물질(高分子物質) 첨가(添加)에 따른 마찰저항감소(摩擦抵抗減少)에 관한 연구(硏究))

  • Kim, J.G.;Cha, K.O.;Choi, H.J.;Kim, C.B.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.8 no.2
    • /
    • pp.198-207
    • /
    • 1996
  • It is well known that drag reduction in single phase liquid flow is affected by polymer material, molecular weight, polymer concentration, pipe diameter, and flow velocity. Drag reduction in two phase flow can be applied to the transport of crude oil, phase change system such as chemical reactor, pool and boiling flow, and to present cavitation which occurs in pump impellers. But the research of drag reduction in two phase flow is not sufficient. The purpose of the present work is to evaluate the drag reduction by measuring pressure drop, void fraction, mean liquid velocity, and turbulent intensity whether polymer is added in the horizontal two phase system or not. Experiment has been conducted in a test section with the inner diameter of 24mm and the length of 1,500mm. The polymer materials used are two kinds of polyacrylamide[PAAM] and co-polymer[A611P]. The polymer concentration was varied with 50, 100 and 200 ppm under the same experimental conditions. Experimental results showed that the drag reduction of co-polymer is higher than that of polyacrylamide. Mean liquid velocities increased as polymer was added, and turbulent intensity decreased inversely near the pipe wall.

  • PDF