• Title/Summary/Keyword: single laser

Search Result 1,037, Processing Time 0.021 seconds

Characteristics of fiber-optic current sensors using perpendicular coil formers (수직원형틀을 이용한 광섬유전류센서의 동작특성)

  • 이명래;이용희;김만식
    • Korean Journal of Optics and Photonics
    • /
    • v.7 no.4
    • /
    • pp.419-427
    • /
    • 1996
  • Thermally-stabilized fiber-optic current sensors are proposed and demonstrated. The sensor head is made of two coil formers combined perpendicularly. In this sensor head, bending-induced birefringences can be reduced to the level much smaller than those of the single former type because the eigen-axes of the two perpendicular coil formers are made orthogonal to each other. Moreover, thermal variation of the birefringence is also expected to be minimized by the orthogonality of the two polarization eigen-axes. We changed the temperature slowly in the range of 20~45$^{\circ}C$ during 100 minutes. The overall linearity of the sensor is better than 1.2% in the range of 0~1000A. The long-term fluctuation of the sensor is less than 1% when measured for 3 hours at 500A and room temperature. Two orthogonally-polarized laser diodes are combined together to make the incident beam unpolarized. In the signal processing, the signals are separated by two parts and normalized respectively, which minimize the efects of optical fluctuations coming from sources, connectors, etc.

  • PDF

Measurement of Target Objects Based on Recognition of Curvature and Plane Surfaces using a Single Slit Beam Projection (슬릿광 투영법을 이용한 곡면과 평면의 식별에 의한 대상물체의 계측)

  • Choi, Yong-Woon;Kim, Young-Bok
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.5 no.5
    • /
    • pp.568-576
    • /
    • 1999
  • Using a laser sheet beam projector combined with a CCD-Camera, an efficient technique to recognize complex surface of curvature and lane has been demonstrated for the purpose of mobile robot navigation. In general, obstacles of indoor environments in the field of SLIT-RAY plane are captured as segments of an elliptical arc and a line in the camera image. The robot has been capable of moving along around the obstacle in front of it, by recognizing the original shape of each segment with the differential coefficient by means of least squares method. In this technique, the imaged pixels of each segment, particularly elliptical arc, have been converted into a corresponding circular arc in the real-world coordinates so as to make more feasible the image processing for the position and radius measurement than conventional way based on direct elliptical are analyses. Advantages over direct elliptical cases include 1) higher measurement accuracy and shorter processing time because the circular arc process can reduce the shape-specifying parameters, 2) no complicated factor such as the tilt of elliptical arc axis in the image plane, which produces the capability to find column position and radiua regardless of the camera location . These are essentially required for a mobile robot application. This technique yields an accuracy less than 2cm for a 28.5cm radius column located in the range of 70-250cm distance from the robot. The accuracy obtained in this study is sufficient enough to navigate a cleaning robot which operates in indoor environments.

  • PDF

Ordering of manganese spins in photoconducting $Zn_{1-x}Mn_xTe$

  • Kajitani, T.;Kamiya, T.;Sato, K.;Shamoto, S.;Ono, Y.;Sato, T.;Oka, Y.
    • Proceedings of the Korea Association of Crystal Growth Conference
    • /
    • 1998.06a
    • /
    • pp.39-43
    • /
    • 1998
  • Single crystals of{{{{ { Zn}_{ 1-x} {Mn }_{x }{Te} }}}} with x=0.3-0.6 were prepared by the standard Bridgeman method. Diffuse neutron diffraction intensities due to the short range magnetic ordering is found in the vicinities of 1 1/2 0 reciprocal point and its equivalent point, indicating that the magnetic correlation of the clusters is the type III antiferromangetic one do the F-type Bravais class crystals, being identical with that of {{{{{ Cd}_{ 1-x} {Mn }_{x }Te }}}}. Neutron inelastic scattering measure-ment has been performed for {{{{{ Zn}_{ 0.6} { Mn}_{ 0.4}Te }}}} sample using the cold neutron spectrometer. AGNES. High resolution measurement with the energy resolution of {{{{ TRIANGLE E= +- .01meV}}}} was carried out in the temperature range from 10K to the ambient. Critical scattering, closely related with the spin glass transition, has been observed for the first time in this semimagnetic semi-conductor. The critical scattering is observed at temperatures in the vicinity of the spin glass transition temperature, 17K. The scattering is observed as a kind of quasielastic scattering in the reciprocal range where the elastic magnetic diffuse scattering has been observed, e.g., 11/20 reciprocal point, indicating the spin fluctuation has dynamic components in this material. Photoconductivity has been discovered below 150K in {{{{{ Zn}_{ 0.4} {Mn }_{0.6 } Te}}}}. The electric AC conductivity has been increased dramatically under the laser light with the wave lengths of {{{{ lambda =6328,5145 and4880 }}}}$\AA$ ,respectively. After the light was darkened, the conductivity was reduced to the original level after about 2000 seconds at 50K, being above the spin glass transition temperature. This phenomenon is the typical persistent photoconductivity; PPC which was similarly found in {{{{ { Zn}_{ 1-x} { Mn}_{x} Te}}}}.

  • PDF

Functional Integration of Serial Dilution and Capillary Electrophoresis on a PDMS Microchip

  • Chang, Jun-Keun;Heo, Yun-Seok;Hyunwoo Bang;Keunchang Cho;Seok Chung;Chanil Chung;Han, Dong-Chul
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.8 no.4
    • /
    • pp.233-239
    • /
    • 2003
  • For the quantitative analysis of an unknown sample a calibration curve should be obtained, as analytical instruments give relative, rather than absolute measurements. Therefore, researchers should make standard samples with various known concentrations, measure each standard and the unknown sample, and then determine the concentration of the unknown by comparing the measured value to those of the standards. These procedures are tedious and time-consuming. Therefore, we developed a polymer based microfluidic device from polydimethylsiloxane, which integrates serial dilution and capillary electrophoresis functions in a single device. The integrated microchip can provide a one-step analytical tool, and thus replace the complex experimental procedures. Two plastic syringes, one containing a buffer solution and the other a standard solution, were connected to two inlet holes on a microchip, and pushed by a hydrodynamic force. The standard sample is serially diluted to various concentrations through the microfluidic networks. The diluted samples are sequentially introduced through microchannels by electro-osmotic force, and their laser-induced fluorescence signals measured by capillary electrophoresis. We demonstrate the integrated microchip performance by measuring the fluorescence signals of fluorescein at various concentrations. The calibration curve obtained from the electropherograms showed the expected linearity.

A Study on the Comparison between an Optical Fiber and a Thermal Sensor Cable for Temperature Monitoring (온도 모니터링을 위한 광섬유 센서와 온도센서 배열 케이블의 비교 연구)

  • Kim, Jung-Yul;Kim, Yoo-Sung;Song, Yoon-Ho
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.03a
    • /
    • pp.1100-1109
    • /
    • 2006
  • In this study, two different technologies which can measure temperature simultaneously at many points are introduced. One is to use a thermal sensor cable that is comprised of addressable thermal sensors connected in parallel within a single cable. The other is to use an optic fiber with Distributed Temperature Sensing (DTS) system. The difference between two technologies can be summarized as follows. A thermal sensor cable has a concept of 'point sensing' that can measure temperature at accurate position of a thermal sensor. So the accuracy and resolution of temperature measurement are up to the ability of the thermal sensor. Whereas optic fiber sensor has a concept of 'distributed sensing' because temperature is measured by ratio of Stokes and anti-Stokes component intensities of Raman backscatter that is generated when laser pulse travels along an optic fiber. It's resolution is determined by measuring distance, measuring time and spatial resolution. The purpose of this study is that application targets of two temperature measurement techniques are checked in technical and economical phases by examining the strength and weakness of them. Considering the functions and characteristics of two techniques, the thermal sensor cable will be suitable to apply to the assessment of groundwater flow, geothermal distribution and grouting efficiency within 300m distance. It is expected that the optic fiber sensor can be widely utilized at various fields (for example: pipe line inspection, tunnel fire detection, power line monitoring etc.) which need an information of temperature distribution over relatively long distance.

  • PDF

Properties of Beta-Ga2O3 Film from the Furnace Oxidation of Freestanding GaN (FS-GaN을 열산화하여 제작된 Beta-Ga2O3 박막의 특성)

  • Son, Hoki;Lee, YoungJin;Lee, Mijai;Kim, Jin-Ho;Jeon, Dae-Woo;Hwang, Jonghee;Lee, Hae-Yong
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.30 no.7
    • /
    • pp.427-431
    • /
    • 2017
  • In this paper, we discuss ${\beta}-Ga_2O_3$ thin films that have been grown on freestanding GaN (FS-GaN) using furnace oxidation. A GaN template was grown by horizontalhydride vapor phase epitaxy (HVPE), and FS-GaN was fabricated using the laser lift off (LLO) system. To obtain ${\beta}-Ga_2O_3$ thin film, FS-GaN was oxidized at $900{\sim}1,100^{\circ}C$. Surface and cross-section of prepared ${\beta}-Ga_2O_3$ thin films were observed by field emission scanning electron microscopy (FE-SEM). The single crystal FS-GaNs were changed to poly-crystal ${\beta}-Ga_2O_3$. The oxidized ${\beta}-Ga_2O_3$ thin film at $1,100^{\circ}C$ was peel off from FS-GaN. Next, oxidation of FS-GaNwas investigated for 0.5~12 hours with variation of the oxidation time. The thicknesses of ${\beta}-Ga_2O_3$ thin films were measured from 100 nm to 1,200 nm. Moreover, the 2-theta XRD result indicated that (-201), (-402), and (-603) peaks were confirmed. The intensity of peaks was increased with increased oxidation time. The ${\beta}-Ga_2O_3$ thin film was generated to oxidize FS-GaN.

Assessment of Tissue Perfusion Following Conventional Liposuction of Perforator-Based Abdominal Flaps

  • Dogan, Zeynep Deniz Akdeniz;Sacak, Bulent;Yalcin, Dogus;Pilanci, Ozgur;Tuncer, Fatma Betul;Celebiler, Ozhan
    • Archives of Plastic Surgery
    • /
    • v.44 no.2
    • /
    • pp.109-116
    • /
    • 2017
  • Background The effect of liposuction on the perforators of the lower abdominal wall has been investigated in several studies. There are controversial results in the literature that have primarily demonstrated the number and patency of the perforators. The aim of this study was to determine the effect of liposuction on the perfusion of perforator-based abdominal flaps using a combined laser-Doppler spectrophotometer (O2C, Oxygen to See, LEA Medizintechnik). Methods Nine female patients undergoing classical abdominoplasty were included in the study. Perforators and the perfusion zones of the deep inferior epigastric artery flap were marked on the patient's abdominal wall. Flap perfusion was quantitatively assessed by measuring blood flow, velocity, capillary oxygen saturation, and relative amount of hemoglobin for each zone preoperatively, after tumescent solution infiltration, following elevation of the flap on a single perforator, and after deep and superficial liposuction, respectively. Results The measurements taken after elevation of the flap were not significantly different than measurements taken after the liposuction procedures. Conclusions The liposuction procedure does not significantly alter the perfusion of perforator-based abdominal flaps in the early period. The abdominal tissue discarded in a classic abdominoplasty operation can be raised as a perforator flap and has been demonstrated to be a unique model for clinical research.

Microstructure Characterization of Ternary ZnSSe/GaAs Epilayer Grown by MBE (MBE로 성장시킨 3원계 ZnSSe/GaAs 에피층의 미세구조 특성)

  • Lee, Hwack-Joo;Ryu, Hyun;Park, Hae-Sung;Kim, Tae-Il
    • Applied Microscopy
    • /
    • v.25 no.3
    • /
    • pp.75-81
    • /
    • 1995
  • The microstructural characterization of ternary $ZnS_{x}Se_{1-x}$(x=0.085) on GaAs(001) substrate grown up to $2{\mu}m\;at\;300^{\circ}C$ by molecular beam epitaxy(MBE) which has a single growth chamber was investigated by high resolution transmission electron microscope (HRTEM) working at 300 kV with point resolution of 0.18nm. The interface in the ZnSSe/GaAs specimen maintains a pseudomorphism with the substrate, but the epilayer has high density of stacking faults and moire fringes. The pits which had formed along <111> direction were found at the interface of ZnSSe/GaAs. The pits were responsible for producing defects in both epilayer and substrate. The wavy interface which has the difference of 15nm in height was found to maintain the pseudomorphism with the substrate and no stacking faults were found around the interface. However there exists faint and fine moire fringes in the epilayer near interface.

  • PDF

The black hole mass-stellar velocity relation of the present-day active galaxies

  • Woo, Jong-Hak
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.35 no.1
    • /
    • pp.79-79
    • /
    • 2010
  • To investigate whether the present-day active galaxies follow the same black hole mass vs. stellar velocity dispersion (MBH-$\sigma*$) relation as quiescent galaxies, we measured the velocity dispersions of a sample of local Seyfert 1 galaxies, for which black hole masses were measured via reverberation mapping. We measured stellar velocity dispersions from high S/N optical spectra centered on the Ca II triplet region (${\sim}8500^{\circ}A$), obtained at the Keck, Palomar, and Lick Observatories. For two objects, in which the Ca II triplet region was contaminated by nuclear emission, we used high-quality H-band spectra obtained with the OH-Suppressing Infrared Imaging Spectrograph and laser-guide star adaptive optics at the Keck-II Telescope. Combining our new measurements with data from the literature, we assemble a sample of 24 active galaxies with stellar velocity dispersions and reverberation MBH in the range of black hole mass 106< MBH /$M{\odot}$ < 109,toobtainthefirstreverberationmappingconstraintsontheslopeandintrinsicscatteroftheMBH- $\sigma*$ relation of active galaxies. Assuming a constant virial coefficient f for the reverberation MBH, we find a slope ${\beta}=3.55{\pm}0.60$ and the intrinsic scatter ${\sigma}int=0.43{\pm}0.08$ dex in the relation log (MBH/M${\odot}$)=$\alpha+\beta$ log(${\sigma}*$/200 km s-1), which are consistent with those found for quiescent galaxies. We derive an updated value of the virial coefficient f by finding the value which places the reverberation masses in best agreement with the MBH - $\sigma*$ relation of quiescent galaxies; using the quiescent MBH - $\sigma*$ relation determined by Gultekin et al. we find log f=0.72+0.09 (or $0.71{\pm}0.10$) with an intrinsic scatter of $0.44{\pm}0.07$ (or 0.46+0.07) dex. No correlations between f and parameters connected to the physics of accretion (such as the Eddington ratio or line-shape measurements) are found. The uncertainty of the virial coefficient remains one of the main sources of the uncertainty in black hole mass determination using reverberation mapping, and therefore also in single-epoch spectroscopic estimates of black hole masses in active galaxies.

  • PDF

Efficacy of Multiple Low-dose Photodynamic TMPYP4 Therapy on Cervical Cancer Tumour Growth in Nude Mice

  • Liu, Ai-Hong;Sun, Xuan;Wei, Xiao-Qiang;Zhang, You-Zhong
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.9
    • /
    • pp.5371-5374
    • /
    • 2013
  • Objective: Photodynamic therapy (PDT) is an emerging therapeutic procedure suitable for the treatment of cervical cancer. However, the side effects of PDT are severe, including skin ulceration, so we designed an experiment to examine the effects of multiple low-dose photodynamic therapy of 5, 10, 15, 20-tetrakis(1-methylpyridinium-4-yl) porphyrin (Tmpyp4) on tumour growth by utilizing a model in nude mice implanted with Hela cervical cancer cells. Materials and Methods: Female BALB/c nude mice (aged 5-6 weeks, weighing 18-20 g) were used. Hela cervical cancer cells were injected subcutaneously ($1{\times}10^7cells/200{\mu}L$). Ten days after injection, the mice were divided into three groups (n=6), the A group of controls without any treatment, the B group receiving a single-treatment with Tmpyp4 (10 mg/kg, intratumor injection) and irradiation (blue laser, $108J/cm^2$), and the C group given three-treatments with Tmpyp4 (10 mg/kg, intratumor injection) and irradiation at intervals of two days. After starting treatment, tumours were measured every two days, to assess growth. At 2 weeks after the last treatment of C group, tumour tissue and organs were collected from each mouse to evaluate tumor histology and organ damage. Results: Tumour growth in C group was significantly inhibited compared with A and B groups (P<0.05), without any injury to the skin and internal organs. Conclusion: Our novel findings demonstrated that multiple low-dose photodynamic therapy of Tmpyp4 could inhibit cervical cancer growth significantly with no apparent side effects.