• 제목/요약/키워드: single implants

검색결과 193건 처리시간 0.022초

Masticatory function following implants replacing a second molar

  • Kim, Moon-Sun;Lee, Jae-Kwan;Chang, Beom-Seok;Um, Heung-Sik
    • Journal of Periodontal and Implant Science
    • /
    • 제41권2호
    • /
    • pp.79-85
    • /
    • 2011
  • Purpose: The aim of this study was to obtain objective and standardized information on masticatory function and patient atisfaction following second molar single implant therap. Methods: Twenty adult patient, who had restored second molar single implants more than 1 month before the study, were enrolled in this stud. All patients received a chewing test using peanuts before and after insertion of the implant prosthesi, with a questionnaire and visual analogue scale (VAS) to evaluate the effect of second molar single implant therap. Results: his study obtained standardized information on the masticatory function objectively (e.g., P, R, $X_{50}$) before (Pre-insertion) and after insertion (Post-insertion) of the implant prosthesis. Masticatory performance (P) after insertion of the implant prosthesis significantly increased from $67.8{\pm}9.9$ to $84.3{\pm}8.5$% (P<0.0001). With the implant prosthesis, the P value increased by 24%. The masticatory efficiency index (R) of Post-insertion is higher than that of Pre-insertion (P<0.0001). With the implant prosthesis, the R value increased by 29%. The median particle size ($X_{50}$) of Post-insertion is lower than that of Preinsertion (P<0.0001). More than 90% of the patients were satisfied with the second molar single implant therapy from a functional point of view. Conclusions: These findings indicate that a second molar single implant can increase masticatory function.

Risk indicators for mucositis and peri-implantitis: results from a practice-based cross-sectional study

  • Rinke, Sven;Nordlohne, Marc;Leha, Andreas;Renvert, Stefan;Schmalz, Gerhard;Ziebolz, Dirk
    • Journal of Periodontal and Implant Science
    • /
    • 제50권3호
    • /
    • pp.183-196
    • /
    • 2020
  • Purpose: This practice-based cross-sectional study aimed to investigate whether common risk indicators for peri-implant diseases were associated with peri-implant mucositis and peri-implantitis in patients undergoing supportive implant therapy (SIT) at least 5 years after implant restoration. Methods: Patients exclusively restored with a single implant type were included. Probing pocket depth (PPD), bleeding on probing (BOP), suppuration, and radiographic bone loss (RBL) were assessed around implants. The case definitions were as follows: peri-implant mucositis: PPD ≥4 mm, BOP, no RBL; and peri-implantitis: PPD ≥5 mm, BOP, RBL ≥3.5 mm. Possible risk indicators were compared between patients with and without mucositis and peri-implantitis using the Fisher exact test and the Wilcoxon rank-sum test, as well as a multiple logistic regression model for variables showing significance (P<0.05). Results: Eighty-four patients with 169 implants (observational period: 5.8±0.86 years) were included. A patient-based prevalence of 52% for peri-implant mucositis and 18% for peri-implantitis was detected. The presence of 3 or more implants (odds ratio [OR], 4.43; 95 confidence interval [CI], 1.36-15.05; P=0.0136) was significantly associated with an increased risk for mucositis. Smoking was significantly associated with an increased risk for peri-implantitis (OR, 5.89; 95% CI, 1.27-24.58; P=0.0231), while the presence of keratinized mucosa around implants was associated with a lower risk for peri-implantitis (OR, 0.05; 95% CI, 0.01-0.25; P<0.001). Conclusions: The number of implants should be considered in strategies to prevent mucositis. Furthermore, smoking and the absence of keratinized mucosa were the strongest risk indicators for peri-implantitis in patients undergoing SIT in the present study.

Effect of abutment screw length and cyclic loading on removal torque in external and internal hex implants

  • Mohammed, Hnd Hadi;Lee, Jin-Han;Bae, Ji-Myung;Cho, Hye-Won
    • The Journal of Advanced Prosthodontics
    • /
    • 제8권1호
    • /
    • pp.62-69
    • /
    • 2016
  • PURPOSE. The purpose of this study was to evaluate the effects of abutment screw length and cyclic loading on the removal torque (RTV) in external hex (EH) and internal hex (IH) implants. MATERIALS AND METHODS. Forty screw-retained single crowns were connected to external and internal hex implants. The prepared titanium abutment screws were classified into 8 groups based on the number of threads (n = 5 per group): EH 12.5, 6.5, 3.5, 2.5 and IH 6.5, 5, 3.5, 2.5 threads. The abutment screws were tightened with 20 Ncm torque twice with 10-minute intervals. After 5 minutes, the initial RTVs of the abutment screws were measured with a digital torque gauge (MGT12). A customized jig was constructed to apply a load along the implant long axis at the central fossa of the maxillary first molar. The post-loading RTVs were measured after 16,000 cycles of mechanical loading with 50 N at a 1-Hz frequency. Statistical analysis included one-way analysis of variance and paired t-tests. RESULTS. The post-loading RTVs were significantly lower than the initial RTVs in the EH 2.5 thread and IH 2.5 thread groups (P<.05). The initial RTVs exhibited no significant differences among the 8 groups, whereas the post-loading RTVs of the EH 6.5 and EH 3.5 thread groups were higher than those of the IH 3.5 thread group (P<.05). CONCLUSION. Within the limitations of this study, the external hex implants with short screw lengths were more advantageous than internal hex implants with short screw lengths in torque maintenance after cyclic loading.

DENTIS 내부연결형 서브머지드 임플란트에서 지대주 선택에 따른 성공률의 후향적 연구 (A retrospective randomized study of success rates according to abutment selection in DENTIS submerged implant with an internal hex connection)

  • 김은희;이정은;황희성;김철훈;김정한;김복주
    • 대한치과의사협회지
    • /
    • 제56권11호
    • /
    • pp.605-614
    • /
    • 2018
  • PURPOSE. The purpose of this study is to determine the efficacy of the DENTIS submerged-type implant with an internal hex connection and to build corresponding abutment-selection criteria. MATERIAL AND METHODS. A total of 204 patients received submerged implant fixtures with an internal hex connection at the Dong-A University Hospital Dental clinic in Busan from January 2013 and May 2016. Three specific abutments, UCLA abutments, customized abutments, ready-made abutments, were randomly selected. Implant success was defined as the basis of the International Congress of Oral Implantologists(ICOI, 2007) criteria. The relationship between the implant success rate and the abutment factor was analyzed using the Kruskal-Wallis test(P<.05). RESULTS. A total of 508 implants were placed in 204 patients. After a mean observation period of 38.6 months, 493 out of 508 implants were in normal function, yielding an overall success rate of 97.05%. A total of 15 implants failed: 10 in the maxillary molar area, 4 in the mandibular molar area, and 1 in the mandibular incisal area. All of the implant failures occurred in a single-implant prosthesis, especially high in the maxillary molar area. The Kruskal-Wallis analysis showed that abutment selection has no significant correlation with implant failure(P>.05). CONCLUSION. DENTIS submerged implants with an internal hex connection showed predictable results with a success rate of 97.05%. It is no influence on the success rate in the selection of submerged implant abutment with an internal hex connection.

  • PDF

지르코니아 및 티타늄 임플란트를 사용한 지지골 및 임플란트 유지 수복물의 응력 분포 비교: 3차원 유한 요소 분석 (Comparison of stress distribution in bone and implant-supported dental prosthesis with zirconia and titanium implants: a 3-dimensional finite element analysis)

  • 홍민호
    • 대한치과기공학회지
    • /
    • 제42권4호
    • /
    • pp.348-354
    • /
    • 2020
  • Purpose: Zirconia is differentiated from other ceramics because of its high resistance to corrosion and wear, excellent flexural strength (900~1400 MPa), and high hardness. Dental zirconia with proven mechanical/biological stability is suitable for the manufacture of implants. However, there are limited in vivo studies evaluating stress distribution in zirconia compared with that in titanium implants and studies analyzing finite elements. This study was conducted to evaluate the stress distribution of the supporting bone surrounding zirconia and titanium implants using the finite element analysis method. Methods: For finite element analysis, a single implant-supported restoration was designed. Using a universal analysis program, eight occlusal points were set in the direction of the occlusal long axis. The occlusal load was simulated at 700 N. Results: The zirconia implant (47.7 MPa) von Mises stress decreased by 5.3% in the upper cortical bone compared with the titanium implant (50.2 MPa) von Mises stress. Similarly, the zirconia implant (20.8 MPa) von Mises stress decreased by almost 4% in the cancellous bone compared with the titanium implant (21.7 MPa) von Mises stress. The principal stress in the cortical and cancellous bone exhibited a similar propensity to von Mises stress. Conclusion: In the supporting bone, the zirconia implant is able to reduce bone resorption caused by mechanically transferred stress. It is believed that the zirconia implant can be a potential substitute for the titanium implant by reinforcing aesthetic characteristics and improving stress distribution.

Hyaluronic acid reduces inflammation and crevicular fluid IL-1β concentrations in peri-implantitis: a randomized controlled clinical trial

  • Sanchez-Fernandez, Elena;Magan-Fernandez, Antonio;O'Valle, Francisco;Bravo, Manuel;Mesa, Francisco
    • Journal of Periodontal and Implant Science
    • /
    • 제51권1호
    • /
    • pp.63-74
    • /
    • 2021
  • Purpose: This study investigated the effects of hyaluronic acid (HA) on peri-implant clinical variables and crevicular concentrations of the proinflammatory biomarkers interleukin (IL)-1β and tumor necrosis factor (TNF)-α in patients with peri-implantitis. Methods: A randomized controlled trial was conducted in peri-implantitis patients. Patients were randomized to receive a 0.8% HA gel (test group), an excipient-based gel (control group 1), or no gel (control group 2). Clinical periodontal variables and marginal bone loss after 0, 45, and 90 days of treatment were assessed. IL-1β and TNF-α levels in crevicular fluid were measured by enzyme-linked immunosorbent assays at baseline and after 45 days of treatment. Clustering analysis was performed, considering the possibility of multiple implants in a single patient. Results: Sixty-one patients with 100 dental implants were assigned to the test group, control group 1, or control group 2. Probing pocket depth (PPD) was significantly lower in the test group than in both control groups at 45 days (control 1: 95% CI, -1.66, -0.40 mm; control 2: 95% CI, -1.07, -0.01 mm) and 90 days (control 1: 95% CI, -1.72, -0.54 mm; control 2: 95% CI, -1.13, -0.15 mm). There was a trend towards less bleeding on probing in the test group than in control group 2 at 90 days (P=0.07). Implants with a PPD ≥5 mm showed higher levels of IL-1β in the control group 2 at 45 days than in the test group (P=0.04). Conclusions: This study demonstrates for the first time that the topical application of a HA gel in the peri-implant pocket and around implants with peri-implantitis may reduce inflammation and crevicular fluid IL-1β levels.

전정감각 중심의 감각통합치료가 인공와우 수술 아동의 감각처리, 문제행동, 청각행동에 미치는 영향 (The Effect of Vestibular Sensory Integration on the Sensory Processing, Problem Behavior, and Auditory Behavior of Children With Cochlear Implants)

  • 박예현;김희
    • 대한감각통합치료학회지
    • /
    • 제19권1호
    • /
    • pp.13-23
    • /
    • 2021
  • 목적 : 본 연구는 전정감각 중심의 감각통합치료가 인공와우 수술 아동의 감각처리, 문제행동, 청각행동에 미치는 영향을 알아보고자 한다. 연구방법 : 본 연구는 대전시에 거주하는 인공와우 수술 후 보조기기를 착용한 아동3명을 대상자로 모집한 후에 2019년 8월부터 2019년 11월까지 총 11주간 전정감각 중심의 감각통합치료 프로그램을 실시하였다. 연구 설계는 단일 사례 실험 설계방법(single subject design)으로 A-B 설계를 사용하였으며, 기초선 기간 4회, 중재기 15회로 진행되었다. 기초선 기간에는 감각통합치료를 제공하지 않고, 중재기에는 40분간 치료사와 함께 자유놀이를 진행하였다. 중재기에는 대전시의 아동발달센터에서 1회기 당 40분으로 전정감각 중심의 감각통합치료를 제공하였다. 중재 시작 전과 중재기 15회 직후 참여 아동의 감각처리 능력과 청각행동을 평가했다. 문제 행동 관찰은 기초선 자유놀이 시간에, 중재기에는 치료가 실시되는 시간에 아동을 관찰하여 기록하였다. 결과 : 전정감각 중심의 감각통합치료를 중재하기 전보다 후에 A, B, C 세 명의 아동에게서 감각처리와 청각행동의 긍정적인 변화가 있었고, 문제행동에서도 2표준편차 밴드 그래프에서 긍정적인 변화를 확인할 수 있었다. 결론 : 본 연구의 결과는 전정감각 중심의 감각통합치료가 인공와우 수술 아동의 감각처리, 문제행동, 청각행동에 긍정적인 효과가 있음을 제시한다.

Early implant failure: a retrospective analysis of contributing factors

  • Kang, Dae-Young;Kim, Myeongjin;Lee, Sung-Jo;Cho, In-Woo;Shin, Hyun-Seung;Caballe-Serrano, Jordi;Park, Jung-Chul
    • Journal of Periodontal and Implant Science
    • /
    • 제49권5호
    • /
    • pp.287-298
    • /
    • 2019
  • Purpose: The aim of this retrospective study was to determine the prevalence of early implant failure using a single implant system and to identify the factors contributing to early implant failure. Methods: Patients who received implant treatment with a single implant system ($Luna^{(R)}$, Shinhung, Seoul, Korea) at Dankook University Dental Hospital from 2015 to 2017 were enrolled. The following data were collected for analysis: sex and age of the patient, seniority of the surgeon, diameter and length of the implant, position in the dental arch, access approach for sinus-floor elevation, and type of guided bone regeneration (GBR) procedure. The effect of each predictor was evaluated using the crude hazard ratio and the adjusted hazard ratio (aHR) in univariate and multivariate Cox regression analyses, respectively. Results: This study analyzed 1,031 implants in 409 patients, who comprised 169 females and 240 males with a median age of 54 years (interquartile range [IQR], 47-61 years) and were followed up for a median of 7.2 months (IQR, 5.6-9.9 months) after implant placement. Thirty-five implants were removed prior to final prosthesis delivery, and the cumulative survival rate in the early phase at the implant level was 95.6%. Multivariate regression analysis revealed that seniority of the surgeon (residents: aHR=2.86; 95% confidence interval [CI], 1.37-5.94) and the jaw in which the implant was placed (mandible: aHR=2.31; 95% CI, 1.12-4.76) exerted statistically significant effects on early implant failure after adjusting for sex, age, dimensions of the implant, and type of GBR procedure (preoperative and/or simultaneous) (P<0.05). Conclusions: Prospective studies are warranted to further elucidate the factors contributing to early implant failure. In the meantime, surgeons should receive appropriate training and carefully select the bone bed in order to minimize the risk of early implant failure.

치과용 임플란트에 대한 ISO 14971 기반의 리스크관리 (Application of Risk Management for Dental Implants Based on ISO 14971)

  • 윤지훈;김영진;전계록;정창모
    • 한국안전학회지
    • /
    • 제27권2호
    • /
    • pp.92-97
    • /
    • 2012
  • Risk management is the process that helps to identify hazards, analyze them, and then to create an action plan to avoid and mitigate these hazards. The main objective of risk management in product development and manufacturing is to provide safe and efficient products without spending too many resources. Medical device manufacturers also face enormous risks - regulatory, legal, and financial - based on their products and processes, and the concepts of risk management are particularly important because any single failure may result in serious damages to body or loss of life. In this regard, a set of guidelines for the application of risk management to medical devices has been issued by ISO and specified in the document ISO 14971 Medical devices - Application of risk management to medical devices. The main objective of this study is to investigate the application of risk management to dental implant development and manufacturing processes based on ISO 14971. A general risk management process is first introduced, and the application of ISO 14971 to dental implants is further investigated.