• 제목/요약/키워드: simultaneous switching

검색결과 113건 처리시간 0.022초

불순물 확산을 동시에 수행하는 수정된 직접접합방법으로 제작된 pn 접합 실리콘소자의 특성 (Characterization of Silicon Structures with pn-junctions Fabricated by Modified Direct Bonding Technique with Simultaneous Dopant Diffusion)

  • 김상철;김은동;김남균;방욱
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 하계학술대회 논문집
    • /
    • pp.828-831
    • /
    • 2001
  • A simple and versatile method of manufacturing semiconductor devices with pn-junctions used the silicon direct bonding technology with simultaneous impurity diffusion is suggested . Formation of p- or n- type layers was tried during the bonding procedure by attaching two wafers in the aqueous solutions of Al(NO$_3$)$_3$, Ga(NO$_3$)$_3$, HBO$_3$, or H$_3$PO$_4$. An essential improvement of bonding interface structural quality was detected and a model for the explanation is suggested. Diode, Dynistor, and BGGTO structures were fabricated and examined. Their switching characteristics are presented.

  • PDF

YBa2Cu3O7 박막을 이용한 하이브리드형 초전도 사고전류제한기의 특성 (Properties of a Hybrid Type Superconducting Fault Current Limiter using YBa2Cu3O7 Films)

  • 최효상;조용선
    • 한국전기전자재료학회논문지
    • /
    • 제19권4호
    • /
    • pp.391-397
    • /
    • 2006
  • We present investigations of a hybrid type superconducting fault current limiter (SFCL), which consists of transformers and resistive superconducting elements. The secondary windings of the transformer were separated into several electrically isolated circuits and linked inductively with each other by mutual flux, each of which has a superconducting current limiting element of $YBa_2Cu_3O_7$ (YBCO) stripes as a current limiting element. Simple connection in series of the SFCL elements tends to produce ill-timed quenching because of power dissipation unbalance between SFCL elements. Both electrical isolation and mutual flux linkage of the elements provides a solution to power dissipation unbalance, inducing simultaneous quench and current redistribution of the YBCO films. This design enables to increase the voltage rating of SFCL with given YBCO stripes.

단거리송전선에서 투입저항이 없는 차단기적용에 관한 연구 (The Study on Application of Circuit Breaker without Closing Resistor in Short Transmission Line)

  • 김정배;정영환;송원표
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제53권1호
    • /
    • pp.31-37
    • /
    • 2004
  • In this paper, the analysis result of the switching surge in substation including GIS(Gas Insulated Switchgear) has been described using the EMTP(Electro Magnetic Transient Program) program. After performing the modeling of the input data, we have reviewed the energization overvoltages of GCB(Gas Circuit Breaker) without closing resistor in 345kV network, according to the conditions of simultaneously operating switch and statistically operating switch. Firstly, it can be known that the energization overvoltage of single line is higher than that of parallel energized line. Secondly, the maximum energization overvoltage obtained in statistics switch is higher than one in simultaneous switch. From these results, it can be known that the phase-to-earth energization overvoltages of $\alpha$-$\beta$ section are less than 2.2 p.u when closing resistor is eliminated. Therefore, it is possible to consider the circuit breaker eliminated the closing resistor in $\alpha$-$\beta$ section.

An Experimental Study on Two Parameter Control for Radiant Floor Heating System

  • Cho, Sung-Hwan;Tae, Choon-Seob;Jang, Chel-Yong
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제6권
    • /
    • pp.136-147
    • /
    • 1998
  • An experimental facility consisting of two 3$\times$4.4$\times$2.8m rooms identical in construction is built. Each room has a control system and storage tank supplying hot water to the radiant floor heating system. The facility enables simultaneous comparison of two different control strategies each implemented in a separate room. The operating performance of three kinds of flow control scheme is tested and compared in this study: (ⅰ) conventional on-off control based on feedback from room air temperature (ⅱ) TPSC(two parameter switching control )(ⅲ) TPOC(two parameter on-off control). Results show that TPSC and TPOC using room air and surface temperature sequentially as feedback signal to control hot water supply is the better temperature regulation scheme than conventional control based on feedback from only room air temperature. They are good candidates for the room with radiant floor heating system under continuous and intermittent heating mode.

  • PDF

Simultaneous Burst and Burst Control Packet Transmission Protocol for Optical Burst Switching Ring Networks

  • Park, Joon-Pyo;Lee, Man-Seop
    • ETRI Journal
    • /
    • 제29권1호
    • /
    • pp.116-119
    • /
    • 2007
  • In this letter, we design a collision resolution protocol for optical burst switching ring networks to avoid burst collision. We define the offset time condition for no burst transmission collision and manage the free time list of nodes for no burst reception collision. In order to improve the throughput, we use a fiber delay line, void-filling, and void-compression. This protocol does not require any additional procedures for bandwidth reservation such as centralized assignment of bandwidth, lightpath setup of WDM ring networks, or token capturing for the burst transmission. The simulation results show that the proposed protocol can achieve high throughput while saving 70% of wavelengths when compared to round robin with random selection, round robin with persistent, and round robin with non-persistent with only destination delay.

  • PDF

Design of Power Plane for Suppressing Spurious Resonances in High Speed PCBs

  • Oh Seung-Seok;Kim Jung-Min;Yook Jong-Gwan
    • Journal of electromagnetic engineering and science
    • /
    • 제6권1호
    • /
    • pp.62-70
    • /
    • 2006
  • This paper presents a new power plane design method incorporating a single geometry derived from a unit cell of photonic bandgap(PBG) structure. This method yields constantly wide suppression of parallel plate resonances from 0.9 GHz to 4.2 GHz and is very efficient to eliminate PCB resonances in a specified frequency region to provide effective suppression of simultaneous switching noise(SSN). It is shown that with only two cells the propagation of unwanted high frequency signals is effectively suppressed, while it could provide continuous return signal path. The measured results agree very well with theoretically predicted ones, and confirm that proposed method is effective for reducing EMI, with measured near-field distribution. The proposed topology is suitable for design of high speed digital system.

Switching properties of multivariate Shewhart control charts

  • Kim, Bo-Jung;Cho, Gyo-Young
    • Journal of the Korean Data and Information Science Society
    • /
    • 제28권4호
    • /
    • pp.911-925
    • /
    • 2017
  • We investigate the properties of multivariate Shewart control charts with VSI procedure for monitoring simultaneous monitoring mean vector and covariance matrix in term of ANSW (average number of switches), probability of switch and ASI (average sampling interval), ATS (average time to signal). From examining the ANSW values, we know that it does not switch frequently. The VSI control charts are superior to the corresponding FSI control charts in terms of ATS. And, it can be also seen that the VSI procedures have substantially fewer switches for small or moderate shifts of the mean vector and variances.

Numerical Switching Performances of Cumulative Sum Chart for Dispersion Matrix

  • Chang, Duk-Joon
    • 통합자연과학논문집
    • /
    • 제12권3호
    • /
    • pp.78-84
    • /
    • 2019
  • In many cases, the quality of a product is determined by several correlated quality variables. Control charts have been used for a long time widely to control the production process and to quickly detect the assignable causes that may produce any deterioration in the quality of a product. Numerical switching performances of multivariate cumulative sum control chart for simultaneous monitoring all components in the dispersion matrix ${\Sigma}$ under multivariate normal process $N_p({\underline{\mu}},{\Sigma})$ are considered. Numerical performances were evaluated for various shifts of the values of variances and/or correlation coefficients in ${\Sigma}$. Our computational results show that if one wants to quick detect the small shifts in a process, CUSUM control chart with small reference value k is more efficient than large k in terms of average run length (ARL), average time to signal (ATS), average number of switches (ANSW).

바닥 난방공간의 다인자 제어에 관한 실험적 연구 (An experimental study on the multiple parameter switching control for floor heating system)

  • 조성환;태춘섭;장철용
    • 설비공학논문집
    • /
    • 제9권4호
    • /
    • pp.472-483
    • /
    • 1997
  • An experimental facility consisting of two $3{\times}4.4{\times}3.8m$ rooms identical in construction is built. Each room has a control system and storage tank supplying hot water to the radiant floor heating system. The facility enables simultaneous comparision of two different control stratigies each implemented in a separate room. The operating performance of three kinds of flow control scheme is tested and compared in this study : (i) conventional on-off control based on feedback from room air temperature (ii) TPSC(two parameter switching control) (iii) TPOC(two parameter on-off control). Results show that TPSC and TPOC using room air and surface temperature sequentially as feedback signal to control hot water supply is the better temperature regulation scheme than conventional control based on feedback from only room air temperature. They are good candidates for the room with radiant floor heating system under continuous and intermittent heating mode.

  • PDF

스텝 펄스파를 사용하는 캐스케이드 인버터에서 스위치의 간단한 도통각 계산법 (A Simple Method for Conducting Angle Calculation of Switching Devices in Cascaded Inverters Using Step Pulse Waves)

  • 김형창;김태진;강대욱;현동석
    • 전력전자학회논문지
    • /
    • 제8권6호
    • /
    • pp.488-495
    • /
    • 2003
  • 최근에 높은 전력과 전압의 적용을 위한 방법으로써 PWM 방법보다는 스텝 펄스파를 이용해 출력 전압 레벨을 조합하는 멀티레벨 인버터가 폭 넓게 사용되어지고 있다. 이 방식은 도통각을 통해 한주기에 한번만 온, 오프 하기 때문에 스위칭 손실 측면에서 유리한 특성을 갖는다. 본 논문에서는 도통각을 얻는 간단한 방법을 제안하며 이 방법은 출력 전압 레벨에 의해 나누어진 기준 전압 파형의 전압-시간 면적들을 통해 인버터의 출력 스텝 펄스파를 구성한다. 또한 제안한 방법은 근사법에 의한 연립방정식의 해를 구할 필요가 없기 때문에 기존의 방법과는 달리 계산량을 줄일 수 있고 온 라인에 의해 도통각을 얻을 수 있는 장점이 있다.