• Title/Summary/Keyword: simultaneous stabilization

Search Result 60, Processing Time 0.031 seconds

STABILITY OF SIMULTANEOUS MAXILLARY AND MANDIBULAR SURGERY;[Ⅰ]Wire osteosynthesis (상하악 동시 악교정술시 안정성에 관한 연구;[Ⅰ] 강선 고정에 의한 방법)

  • Kim, Yeo-Gab
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.12 no.2
    • /
    • pp.9-20
    • /
    • 1990
  • A series of 19 cases with maxillary hyperplasia and mandibular retrognathia were operated on by simultaneous superior repositioning of the maxilla after Le Fort I osteotomy and anterior repositioning of the mandible after bilateral sagittal split ramus osteotomies with or without osteotomy of the inferior border of the mandible. These were evaluated by retrospective cephalometric and computer analysis for the longitudinal skeletal and dental changes for an average of 17.1 months after surgery. For stabilization of the osteotomized segments, the authors used wire osteosynthesis by means of bilateral infraorbital and zygomatic buttress suspension wire at the maxilla, and direct interosseous wire at the split segments of the mandibular rami. Results show generally good stability after simultaneous maxillary and mandibular surgery with wire osteosynthesis, and a minimal to moderate tendency toward skeletal and dental relapse. This article is a preliminary study to defy the efficiency of the wire osteosynthesis (wo)compared with rigid internal fixation (RIF) for simultaneous maxillary and mandibular surgery. 1. The vertical relapse rate of the A point after superior repositioning of the maxilla is 2.2%. 2. The horizontal relapse rate of the B point after advancement of the mandible is 18.3%. 3. The condyle is distracted inferiorly and slightly posteriorly at the immediate postoperative period. 4. At the long term follow up examination, the condyle presents tendency of return to the preoperative position. 5. Condylar segment angle is decreased at the immediate postoperative period, and at the long term follow up evaluation, the angle is increased. 6. Gonial angle is increased at the immediate postoperative period, and then is decreased at the long term follow up evaluation. 7. The dentition is satisfactory with acceptable movement at the long term follow up evaluation. 8. At the mandibular free body analysis, genioplasty shows good stability. 9. Wire osteosynthesis provides excellent stabilization for the simultaneous maxillary and mandibular surgery.

  • PDF

Strong Stabilization Controller Design Using Advanced Unit Interpolation algorithm (개선된 Unit 보강 알고리즘을 이용한 강안정화 제어기 설계)

  • 윤한오;신창훈;박홍배
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.31B no.8
    • /
    • pp.31-38
    • /
    • 1994
  • This paper presents an improved interpolation algorithm which enables to find a unit function in $H^{\infty}$. From the proposed algorithm the interpolation problem on the infinity point with multiplicity can be solved. This is based on the DPL algorithm the acquired unit function has low order and can be directly applied to strong/simultaneous stabilization problem in control systems. Finally, we verify that poles of transfer function of closed-loop system exist in stable region while investgating internal stability.

  • PDF

The Effect of Proprioceptive Neuromuscular Facilitation and Traditional Trunk Stabilization Training on the Rectus Abdominis Muscle Contraction (고유수용성신경근촉진 기법을 이용한 체간부 안정화 운동이 복직근 수축력에 미치는 효과)

  • Lee, Nam-Yong;Kim, Su-Hyon;Kim, Tae-Youl
    • Journal of the Korean Academy of Clinical Electrophysiology
    • /
    • v.7 no.1
    • /
    • pp.43-48
    • /
    • 2009
  • Purpose : The purpose of this study was to study the effect of rectus abdominal muscle contraction by proprioceptive neuromuscular facilitation trunk stabilization training using extremity simultaneous pattern (PNF trunk stabilization training) and traditional trunk stabilization training methods. Methods : A group of 24 adults male and female, healthy, with no previous medical history nor disability in neuromuscular system and musculoskeletal system was chosen as subjects, and was divided into a control group, a PNF trunk stabilization training group and a traditional trunk stabilization training group. Experiments were performed on the last two groups, 3 times a week for 6 weeks, totaling 18 times. Using a dynamometer, muscle strength and endurance time on trunk flexion were measured before and after each experiment, and surface electromyography in left and right rectus abdominis were measured. Results : following results were obtained; 1. As for the change in the maximal voluntary isometric contraction (MVIC), all subjects in the trunk stabilization training group showed significant difference from those in the control group. 2. As for surface electromyography measurement and the changes in root mean square at the time of trunk flexion, in the left rectus abdominis, PNF trunk stabilization training group showed significant difference from the control group, while in the right rectus abdominis, traditional trunk stabilization training group showed significant difference. Conclusion : To sum up the results, both trunk stabilization training groups showed improvement in the MVIC of abdominal muscle, motor unit action potential activity, but the difference between two trunk stabilization training groups was not significant. Therefore, while trunk stabilization training significantly improved abdominal muscle contraction, but the difference attributable to training methods was found to be insignificant.

Effects of Gaze Stabilization Exercise and Cognitive Training on Balance and Gait in Subacute Stroke Patients: Randomized Controlled Trial

  • Hye-Ryeon Jang;Ye-Ji Kim;Myoung-Kwon Kim
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.19 no.1
    • /
    • pp.155-164
    • /
    • 2024
  • PURPOSE: The purpose of this study was to evaluate the effects of simultaneous application of gaze stabilization exercise and cognitive training on the balance and gait ability in subacute stroke patients. METHODS: Thirty-five patients diagnosed with stroke within 3-6 months were randomly assigned, and the experimental group (n = 18) to which both gaze stabilization exercise and cognitive training were applied and the control group (n = 17) to which only gaze stabilization exercise was applied were targeted. It was performed for 30 minutes at a time, three times a week, for a total of 4 weeks. Berg Balance Scale, Timed Up and Go test, 10Meter Walking Test, and Walking symmetry were evaluated. RESULTS: In the comparison of changes between Berg Balance Scale, Time Up and Go test, 10 Meter Walking Test, and Gait symmetry, both experimental and control groups showed significant differences before and after the intervention, and in the evaluation of Gait symmetry, significant differences between groups. CONCLUSION: As a result of this study, when gaze stabilization exercise and cognitive training were allied simultaneously, it was possible to improve the balance and gait ability of subacute stroke patients, and had a more significant effect on gait ability. In considered that training that simultaneously applies gaze stabilization exercise and cognitive training can be presented as a balance and gait rehabilitation for stroke patients on the future.

Rank-constrained LMI Approach to Simultaneous Linear Quadratic Optimal Control Design (계수조건부 LMI를 이용한 동시안정화 LQ 최적제어기 설계)

  • Kim, Seog-Joo;Cheon, Jong-Min;Kim, Jong-Moon;Kim, Chun-Kyung;Lee, Jong-Moo;Kwon, Soom-Nam
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.13 no.11
    • /
    • pp.1048-1052
    • /
    • 2007
  • This paper presents a rank-constrained linear matrix inequality(LMI) approach to simultaneous linear-quadratic(LQ) optimal control by static output feedback. Simultaneous LQ optimal control is formulated as an LMI optimization problem with a nonconvex rank condition. An iterative penalty method recently developed is applied to solve this rank-constrained LMI optimization problem. Numerical experiments are performed to illustrate the proposed method, and the results are compared with those of previous work.

Influence of changing Combustor Pressure on Flame Stabilization and Emission Charncteristics (연소실 압력변동이 화염안정화와 배출특성에 미치는 영향)

  • Kim, Jong-Ryul;Choi, Gyung-Min;Kim, Duck-Jool
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2354-2359
    • /
    • 2007
  • Influence of changing combustor pressure on flame stabilization and emission index in the swirl-stabilized flame was investigated. The combustor pressure was controlled by suction fan at combustor exit. Pressure index ($P^{\ast}$=Pabs/Patm), where Pabs and Patm indicated the absolute pressure and atmosphere pressure, respectively, was controlled in the range of 0.7${\sim}$1.3 for each equivalence ratio conditions. The flammable limits of swirl flames were largely influenced by changing combustor pressure and they showed similar tendency with laminar flames. NOx emission index decreased with decreasing pressure index for overall equivalence ratio conditions. R.m.s. of pressure fluctuations is increased with decreasing combustor pressure. This flame fluctuation caused incomplete combustion, hence CO emission index increased. These oscillating flames were measured by simultaneous $CH^{\ast}$ chemiluminescence time-series visualization and pressure fluctuation measurement.

  • PDF

Influence of changing combustor pressure and secondary fuel injection on flame stabilization and emission characteristic in swirl flame (연소실 압력변동과 2차 연료 분사가 스월 화염에서 화염안정화와 배출 특성에 미치는 영향)

  • Kim, Jong-Ryul;Choi, Gyung-Min;Kim, Duck-Jool
    • 한국연소학회:학술대회논문집
    • /
    • 2007.05a
    • /
    • pp.133-138
    • /
    • 2007
  • Influence of changing combustor pressure on flame stabilization and emission index in the swirl-stabilized flame was investigated The combustor pressure was controlled by suction fan at combustor exit. Pressure index ($P^{\ast}=P_{abs}/P_{atm}$), where $P_{abs}$ and $P_{atm}$ indicated the absolute pressure and atmosphere pressure, respectively, was controlled in the range of $0.7{\sim}1.3$ for each equivalence ratio conditions. The flammable limits of swirl flames were largely influenced by changing combustor pressure and they showed similar tendency with laminar flames. $NO_x$ emission index decreased with decreasing pressure index for overall equivalence ratio conditions. R.m.s. of pressure fluctuations is increased with decreasing combustor pressure. This flame fluctuation caused incomplete combustion , hence CO emission index increased. These oscillating flames were measured by simultaneous $CH{\ast}$ chemiluminescence time-series visualization and pressure fluctuation measurement.

  • PDF

A simultaneous wavelength tuning and stabilization scheme of a fiber-optic interferometer filter

  • Ahn, Joon-Tae;Lee, Hak-Kyu;Jeon, Min-Yong;Lim, Dong-Sung;Kim, Kyong-Hon
    • Journal of the Optical Society of Korea
    • /
    • v.3 no.1
    • /
    • pp.32-34
    • /
    • 1999
  • We successfully demonstrated a stabilized fiber-optic Mach­Zehnder interferometer filter with continuous tunability. The tunable scheme was achieved with fine wavelength control of an 1.3${\mu}{\textrm}{m}$ tunable laser diode used as a stabilization light source. The transmission wavelength of the tunable filter was shifted linearly with respect to the wavelength change of the stabilization light source.

Simultaneous operation of two group of Auxiliary Block for Korean High Speed Train (고속전철용 보조전력변환장치 1,2군 동시 기동)

  • Cho, Hyun-Wook;Kim, Yuen-Chung;Kim, Tae-Hwan;Jang, Kyung-Hyun;Choi, Jong-Mook
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.1626-1632
    • /
    • 2007
  • Power Car PC1 and PC2 of Korean high speed train have a auxiliary block which consists of two PWM converter respectively. If a auxiliary block happens a critical failure, the other supplies power to full load of train. In this case, a stability of auxiliary block reduces by a increasing load. For increasing a stability of auxiliary block and train system, a auxiliary block consists of two group four PWM converter which operates simultaneously. If a group of a auxiliary block happens a critical failure, the other supplies power to load of a auxiliary block. This paper describes a method for simultaneous movement of auxiliary block which consists of two group four PWM converter.