• Title/Summary/Keyword: simultaneous scanning

Search Result 90, Processing Time 0.036 seconds

Atom-by-Atom Creation and Evaluation of Composite Nanomaterials at RT based on AFM

  • Morita, Seizo
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.73-75
    • /
    • 2013
  • Atomic force microscopy (AFM) [1] can now not only image individual atoms but also construct atom letters using atom manipulation method [2]. Therefore, the AFM is the second generation atomic tool following the well-known scanning tunneling microscopy (STM). The AFM, however, has the advantages that it can image even insulating surfaces with atomic resolution and also measure the atomic force itself between the tip-apex outermost atom and the sample surface atom. Noting these advantages, we have been developing a novel bottom-up nanostructuring system, as shown in Fig. 1, based on the AFM. It can identify chemical species of individual atoms [3] and then manipulate selected atom species to the designed site one-by-one [2] to assemble complex nanostructures consisted of many atom species at room temperature (RT). In this invited talk, we will introduce our results toward atom-by-atom assembly of composite nanomaterials based on the AFM at RT. To identify chemical species, we developed the site-specific force spectroscopy at RT by compensating the thermal drift using the atom tracking. By converting the precise site-specific frequency shift curves, we obtained short-range force curves of selected Sn and Si atoms as shown in Fig. 2(a) and 2(b) [4]. Then using the atom-by-atom force spectroscopy at RT, we succeeded in chemical identification of intermixed three atom species in Pb/Sn/Si(111)-(${\surd}3$'${\surd}3$) surface as shown in Fig. 2(c) [3]. To create composite nanostructures, we found the lateral atom interchange phenomenon at RT, which enables us to exchange embedded heterogeneous atoms [2]. By combining this phenomenon with the modified vector scan, we constructed the atom letters "Sn" consisted of substitutional Sn adatoms embedded in Ge adatoms at RT as shown in Fig. 3(a)~(f) [2]. Besides, we found another kind of atom interchange phenomenon at RT that is the vertical atom interchange phenomenon, which directly interchanges the surface selected Sn atoms with the tip apex Si atoms [5]. This method is an advanced interchangeable single atom pen at RT. Then using this method, we created the atom letters "Si" consisted of substituted Si adatoms embedded in Sn adatoms at RT as shown in Fig. 4(a)~(f) [5]. In addition to the above results, we will introduce the simultaneous evaluation of the force and current at the atomic scale using the combined AFM/STM at RT.

  • PDF

Simultaneous Transfer and Patterning of CVD-Grown Graphene with No Polymeric Residues by Using a Metal Etch Mask

  • Jang, Mi;Jeong, Jin-Hyeok;Trung, T.Q.;Lee, Nae-Eung
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.642-642
    • /
    • 2013
  • Graphene, two dimensional single layer of carbon atoms, has tremendous attention due to its superior property such as high electron mobility, high thermal conductivity and optical transparency. Especially, chemical vapor deposition (CVD) grown graphene has been used as a promising material for high quality and large-scale graphene film. Unfortunately, although CVD-grown graphene has strong advantages, application of the CVD-grown graphene is limited due to ineffective transfer process that delivers the graphene onto a desired substrate by using polymer support layer such as PMMA(polymethyl methacrylate). The transferred CVD-grown graphene has serious drawback due to remaining polymeric residues generated during transfer process, which induces the poor physical and electrical characteristics by a p-doping effect and impurity scattering. To solve such issue incurred during polymer transfer process of CVD-grown graphene, various approaches including thermal annealing, chemical cleaning, mechanical cleaning have been tried but were not successful in getting rid of polymeric residues. On the other hand, lithographical patterning of graphene is an essential step in any form of microelectronic processing and most of conventional lithographic techniques employ photoresist for the definition of graphene patterns on substrates. But, application of photoresist is undesirable because of the presence of residual polymers that contaminate the graphene surface consistent with the effects generated during transfer process. Therefore, in order to fully utilize the excellent properties of CVD-grown graphene, new approach of transfer and patterning techniques which can avoid polymeric residue problem needs to be developed. In this work, we carried out transfer and patterning process simultaneously with no polymeric residue by using a metal etch mask. The patterned thin gold layer was deposited on CVD-grown graphene instead of photoresists in order to make much cleaner and smoother surface and then transferred onto a desired substrate with PMMA, which does not directly contact with graphene surface. We compare the surface properties and patterning morphology of graphene by scanning electron microscopy (SEM), atomic force microscopy(AFM) and Raman spectroscopy. Comparison with the effect of residual polymer and metal on performance of graphene FET will be discussed.

  • PDF

Hydrophobic Cyclodextrin Derivatives as a Sustained Release Carrier of Azidothymidine (아지도싸이미딘의 지속성방출형담체로서의 소수성시클로덱스트린유도체)

  • Seo, Bo-Youn;Park, Gee-Bae;Lee, Kwang-Pyo
    • Journal of Pharmaceutical Investigation
    • /
    • v.26 no.2
    • /
    • pp.71-82
    • /
    • 1996
  • This study has been undertaken to evaluate hydrophobic cyclodextrin(CD) derivatives as a sustained release carrier of azidothymidine(AZT), AZT, which has potent activity against AIDS and AIDS-related complex as thymidine analogue, has been reported that it has significant toxicity and short half life. Therefore, it is necessary to design sustained release oral dosage form to avoid undesirable side effects attributable to an excessive plasma concentration and to reduce the frequency of administration of AZT. Inclusion complexes of AZT with $acetyl-{\beta}-cyclodextrin\;(AC{\beta}CD)$ and $triacetyl-{\beta}-cyclodextrin(TA{\beta}CD)$ were prepared by solvent evaporation method. Interactions of AZT with CD were investigated by Differential Scanning Calorimetry(DSC) and Infrared Spectrophotometry(IR). The decreasing order of water solubilities of AZT and AZT-CD inclusion complexes were as follows; $AZT\;(27.873{\pm}0.015,mg/ml)\;>\;AZT-AC{\beta}CD\;(3.377{\pm}0.003)\;>\;AZT-TA{\beta}CD\;(2.528{\pm}0.001)$. Partition coefficients of $AZT-AC{\beta}CD\;and;\AZT-TA{\beta}CD$ inclusion complexes were increased by 1.27-fold, 1.54-fold in pH 1.2 and 1.32-fold, 1.47-fold in pH 6.8 in comparison with that of AZT. The mean dissolution time (MDT, min) which represents the rapidity of dissolution rate of AZT, $AZT-AC{\beta}CD,\;AZT-TA{\beta}CD$ were 5.12, 14.02 and 19.38 min in pH 1.2 and 2.52, 15.19 and 18.19 min in pH 6.8. AZT was very rapidly and completely dissolved in pH 1.2 and pH 6.8 within 5 minutes. But AZT-CD inclusion complexes showed the sustained release pattern in comparison with AZT alone. The simultaneous in situ nasal and jejunal recirculation study to compare the intrinsic absorptivity and the property of absorption sites revealed that the absorption of $AZT-TA{\beta}CD\;(N:35.35{\pm}1.08%,\;J:27.47{\pm}1.18%)$ was more than that of $AZT\;(N:16.89{\pm}2.25%,\;J:15.86{\pm}2.33%)$. The above results suggest that $TA{\beta}CD$ which is a hydrophobic cyclodextrin may serve as sustained release carrier with absorption enhancing effect.

  • PDF

Effects of Amino Acid-enriched Ruminally Protected Fatty Acids on Plasma Metabolites, Growth Performance and Carcass Characteristics of Hanwoo Steers

  • Park, Byung-Ki;Choi, Nag-Jin;Kim, Hyeong-Cheol;Kim, Tae-Il;Cho, Young-Moo;Oh, Young-Kyoon;Im, Seok-Ki;Kim, Young-Jun;Chang, Jong-Soo;Hwang, In-Ho;Jang, Hyun-Yong;Kim, Jong-Bok;Kwon, Eung-Gi
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.23 no.8
    • /
    • pp.1013-1021
    • /
    • 2010
  • This study was conducted to determine the effects of amino acid-enriched ruminally protected fatty acid (AARPFA) on plasma fatty acids and amino acids, growth performance and carcass characteristics of Korean native steers (Hanwoo) by simultaneous supply of fatty acids and limiting amino acids (methionine and lysine). Eighteen finishing Hanwoo steers, 18 months of age and weighing an average of $459.0{\pm}38.9\;kg$, were used for studies of the metabolism of plasma fatty acids and amino acids during supplementation of AARPFA. Also, 45 finishing Hanwoo steers, 16 months of age and weighing an average of $408.6{\pm}26.5\;kg$, were used for growth performance and carcass characteristics during supplemention of AARPFA. There were three treatments which comprised a basal diet supplemented with AARPFA at 0 g (T1), 50 g (T2) or 100 g (T3), respectively. Concentrations of saturated, unsaturated and total fatty acids in plasma were increased in T3 compared with other treatments (p<0.05). Concentrations of methionine and lysine in plasma were linearly increased with increasing levels of AARPFA (p<0.01). Average daily gain, dry matter intake and feed conversion ratio were not different among the treatments. Marbling score measured by ultra-sound scanning was higher in T3 than in T1 at 24 months of age (p<0.05). Rib eye area, back fat thickness, yield index and yield grade score were similar across the treatments. Marbling score and quality grade score were higher in T3 compared with other treatments (p<0.01). Thus, plasma fatty acids, methionine and lysine metabolism were affected by supplementing with 100 g of AARPFA which also had positive effects on marbling score and meat quality grade of finishing Hanwoo steers.

Screening of White Rot Fungi with Selective Delignification Capacity for Biopulping (백색목재부후균중 Biopulping에 이용가능한 선택적 리그닌분해균의 스크리닝)

  • Lee, Jong-Kyu;Oh, Eun-Sung
    • The Korean Journal of Mycology
    • /
    • v.26 no.2 s.85
    • /
    • pp.144-152
    • /
    • 1998
  • To obtain white rot fungi which have selective delignification capacity and can be used in biopulping processes, 94 different wood rotting fungi were screened and the capabilities of selected species were evaluated on deciduous and coniferous wood blocks. White rot fungi, first of all, were selected by simple enzyme tests, i.e., cellulase activity test; phenol oxidase activity test; laccase and peroxidase activity test. Most organisms that gave a positive Bavendamm gave a strongly positive laccase test with syringaldazine whereas most of those that gave a negative Bavendamm test also negative test for laccase and peroxidase, even if some exceptions were noted. Wood decay experiement were carried out to select fungal species with selective lignin-degrading ability by inoculating selected fungi to both wood blocks of Populus tomentiglandulosa and Larix leptolepis. After 12 weeks of incubation, weight losses, lignin losses, and morphological characteristics of the decayed wood were investigated. Almost all fungi tested caused 2 or more times of weight losses in P. tomentiglandulosa than in L. leptolepis, while no weight losses were detected from the un-inoculated wood blocks. Ceriporiopsis subvermispora and Phanerochaete chrysosporium were the best delignifiers for both hardwood and softwood. P. chrysosporium, however, was less effective than C. subvermispora. Bjerkandera adusta and two unidentified spp. caused delignification for only P. tomentiglandulosa. B. adusta caused simultaneous rot of all cell wall components, resulted in thinning of the secondary cell wall layers. Other fungi caused selective delignification resulting in the removal of lignin from middle lamella and separation of cells from each other.

  • PDF

DEVELOPMENT OF AN AMPHIBIOUS ROBOT FOR VISUAL INSPECTION OF APR1400 NPP IRWST STRAINER ASSEMBLY

  • Jang, You Hyun;Kim, Jong Seog
    • Nuclear Engineering and Technology
    • /
    • v.46 no.3
    • /
    • pp.439-446
    • /
    • 2014
  • An amphibious inspection robot system (hereafter AIROS) is being developed to visually inspect the in-containment refueling storage water tank (hereafter IRWST) strainer in APR1400 instead of a human diver. Four IRWST strainers are located in the IRWST, which is filled with boric acid water. Each strainer has 108 sub-assembly strainer fin modules that should be inspected with the VT-3 method according to Reg. guide 1.82 and the operation manual. AIROS has 6 thrusters for submarine voyage and 4 legs for walking on the top of the strainer. An inverse kinematic algorithm was implemented in the robot controller for exact walking on the top of the IRWST strainer. The IRWST strainer has several top cross braces that are extruded on the top of the strainer, which can be obstacles of walking on the strainer, to maintain the frame of the strainer. Therefore, a robot leg should arrive at the position beside the top cross brace. For this reason, we used an image processing technique to find the top cross brace in the sole camera image. The sole camera image is processed to find the existence of the top cross brace using the cross edge detection algorithm in real time. A 5-DOF robot arm that has multiple camera modules for simultaneous inspection of both sides can penetrate narrow gaps. For intuitive presentation of inspection results and for management of inspection data, inspection images are stored in the control PC with camera angles and positions to synthesize and merge the images. The synthesized images are then mapped in a 3D CAD model of the IRWST strainer with the location information. An IRWST strainer mock-up was fabricated to teach the robot arm scanning and gaiting. It is important to arrive at the designated position for inserting the robot arm into all of the gaps. Exact position control without anchor under the water is not easy. Therefore, we designed the multi leg robot for the role of anchoring and positioning. Quadruped robot design of installing sole cameras was a new approach for the exact and stable position control on the IRWST strainer, unlike a traditional robot for underwater facility inspection. The developed robot will be practically used to enhance the efficiency and reliability of the inspection of nuclear power plant components.

A Clinical Analysis of 24 cases of Cardiac Contusion and Cardiac Concussion (둔상에 의한 심타박상과 심좌상의 임상적 고찰)

  • 이계선;정진악;금동윤;안정태;이재원;신제균
    • Journal of Chest Surgery
    • /
    • v.32 no.3
    • /
    • pp.270-275
    • /
    • 1999
  • Background: In the patients with thoracic injury, we suspect simultaneous cardiac contusion or concussion. We analyzed the patients with possible cardiac injury by electrocardiography, serum creatine kinase (CK), creatine kinase isoenzyme fraction (CK-MB) screening, followed by two dimentional echocardiogram (2-DE) to access the severity of injury. Material and Method: From January 1997 to April 1998, 15-month retrospective study of suspicious myocardial injury was undertaken in including 24 patients admitted for suspected cardiac injury. All patients with history or signs of blunt chest injury were checked serially and the serial CK, CK-MB fraction, electrocardiography (EKG) analysis screening were followed by 2-DE. Result: The age range was between 20-40 years and were predominant male patients in(M:F=3:1). Most common causes of injury were traffic accidents, 15 patients(62.5%). Associated injuries involved multiple rib fractures, sternal fracture and such. EKG findings on the cardiac concussion were within normal limits, EKG findings on the cardiac contusion were nonspecific ST and T wave abnormality. In cardiac contusion patients, CK-MB fraction did not increase significantly on admission but on 2nd, 3rd, 4th hospital days, it increased significantly (p=0.0080, 0.0130, 0.0130). The average admission days were 9.22 in concussion and 26.18 in contusion patients(p=0.0075). Most common complication was the adult respiratory distress syndrome(7 cases), 5 out of the patients with ARDS were mechanically ventilated. There were no deaths. Conclusion: We believe the serial checks of CK-MB, EKG and subsquent two-dementional echocardiographic sector scanning are presently the most sensitive indicators available for structural and functional cardiac injury.

  • PDF

Effect of Drug Eluting Uniformity for Biodegradable Stent by Solid Freeform Fabrication (쾌속조형기법을 이용한 생분해성 스텐트용 메쉬필름의 약물방출거동 효과)

  • Cheong, Sin Young;Kim, Yang Eun;Koh, Young Joo;Shin, Wang Soo;Lee, Jun Hee;Kim, Wan Doo;Yoo, Young Eun;Park, Su A
    • Polymer(Korea)
    • /
    • v.38 no.1
    • /
    • pp.93-97
    • /
    • 2014
  • Biodegradable drug-eluting stent has dual functions of supporting the lumen and treating internal tumor preventing the restenosis by releasing drug. In this study, the polycaprolactone (PCL) based three dimensional (3D) mesh loaded with paclitaxel (PTX) was presented by rapid prototyping (RP) technique of solid freeform fabrication (SFF) for biodegradable drug-eluting stent application. PCL has many advantageous properties such as good biocompatibility, good mechanical properties, and good drug permeability. PTX is widely used in the cancer treatment by inhibiting tumor cell proliferation. Analytical methods of HPLC and NMR were used for simultaneous quantification of PTX. Scanning electron microscopy (SEM) was performed to observe the architecture and morphologies of 3D mesh. The cytotoxicity assay results indicated released PTX's biological activity. This study provided that PCL based 3D mesh loaded with PTX by RP technique has great potential for biodegradable drug-eluting stent application.

Development of a novel combination tablet containing silodosin and solifenacin succinate for the treatment of urination disorder (배뇨 장애 치료를 위한 실로도신과 솔리페나신 숙신산염 함유한 새로운 복합 정제 개발)

  • Choi, Hyung-Joo;Lee, Jeong-Gyun;Kim, Kyeong Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.3
    • /
    • pp.323-332
    • /
    • 2021
  • This study was undertaken to develop a new combination tablet containing silodosin and solifenacin succinate for treating urination disorders, for which a simultaneous analytical method of silodosin and solifenacin succinate was established. The aqueous solubility of silodosin and solifenacin succinate was determined to be higher than 1 mg/ml in various buffers, and dissolution of the silodosin and solifenacin succinate commercial products was accomplished within 30 minutes. The drug-excipients compatibility test was subsequently evaluated using differential scanning calorimetry. Excipients without compatibility were selected, and various combination formulations were prepared applying the wet granulation method. Of these, the formulation comprising silodosin, solifenacin succinate, lactose hydrate, MCC PH101, sodium lauryl sulfate (SLS), Povidone K30, crospovidone and magnesium stearate, having a weight ratio of 8/10/56/112/2/6/6/2, respectively, showed equivalence comparative to the dissolution achieved with the commercial products of silodosin (Thrupas tab) and solifenacin succinate (Vesicare tab). Thus, we propose that compared to the currently available commercial products, this novel combination tablet containing silodosin and solifenacin succinate is an effective alternative for the treatment of urination disorders.

An Assessment of Post-Injection Transmission Measurement for Attenuation Correction With Rotating Pin Sources in Positron Emission Tomography (양전자방출단층촬영(PET)에서 회전 핀선원과 투과 및 방출 동시 영상 방법을 이용한 감쇠보정 방법 특성에 관한 고찰)

  • Lee, J.R.;Choi, Y.;Lee, K.H.;Kim, S.E.;Chi, D.Y.;Shin, S.A.;Kim, B.T.
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.4
    • /
    • pp.533-540
    • /
    • 1995
  • Attenuation correction is important in producing quantitative positron emission tomography (PET) images. Conventionally, photon attenuation effects are corrected using transmission measurements performed before tracer administration. The pre-injection transmission measurement approach may require a time delay between transmission and emission scans for the tracer studies requiring a long uptake period, about 45 minutes for F-18 deoxyglucose study. The time delay will limit patient throughput and increase the likelihood of patient motion. A technique lot performing simultaneous transmission and emission scans (T+E method) after the tracer injection has been validated. The T+E method substracts the emission counts contaminating the transmission measurements to produce accurate attenuation correction coefficients. This method has been evaluated in experiments using a cylindrical phantom filled with background water (5750 cc) containing $0.4{\mu}Ci/cc$ of F-18 fluoride ion and one insert cylinder (276 cc) containing $4.3{\mu}Ci/cc$. GE $Advance^{TM}$ PET scanner and Ge-68 rotating pin sources for transmission scanning were used for this investigation. Post-injection transmission scan and emission scan were peformed alternatively over time. The error in emission images corrected using post-infection transmission scan to emission images corrected transmission scan was 2.6% at the concentration of $1.0{\mu}Ci/cc$. No obvious differences in image quality and noise were apparent between the two images. The attenuation correction can be accomplished with post-injection transmission measurement using rotating pin sources and this method can significantly shorten the time between transmission and omission scans and thereby reduce the likelihood of patient motion and increase scanning throughput in PET.

  • PDF