• Title/Summary/Keyword: simultaneous removal

Search Result 299, Processing Time 0.027 seconds

Simultaneous Nitrification and Dennrincation of Recirculating Aquaculture Water by Biofilter Reactor (생물막 여과 반응기를 이용한 양어장 순환수의 동시 질산화 및 탈질산화 반응)

  • Lee, Min-Gyu;Suh, Kuen-Hack;Oh, Yung-Hee
    • Journal of Environmental Science International
    • /
    • v.6 no.4
    • /
    • pp.409-415
    • /
    • 1997
  • In order to Investigate the possibility as a simple technique of wastewater treatment for recirculating aquaculture system, the experiment by a biofilter unfit was carried out. The high and stable removal efficiency of nitrogen could be obtained by selecting the optimum recycle ratio and DO concentration. It was found that the proper combination of nitrifacation and denitrfication step in the reactor would be required for increasing the removal efficiency. The extent of nitrogen removal gradually decreased UO the rise of re- cycle ratio since the depression of denitrificatlon by the lack of hydrogen donor. The depression of nitrogen removal was overcome by increasing the CIN ratio In the wastewater. The extent of phosphorus removal was increased slightly with the increase of DO concentration and recycle ratio, but high removal efficiency was not observed. However, the extent of COD removal was not affected by recycle ratio and DO concentration and showed the stable removal of above 90%.

  • PDF

Evaluation of SBBR Process Performance Focused on Nitrogen Removal with External Carbon Addition (외부탄소원을 사용한 SBBR의 공정 특성 및 질소제거)

  • Han, Hyejeong;Yun, Zuwhan
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.3
    • /
    • pp.566-571
    • /
    • 2006
  • A sequencing batch biofilm reactor (SBBR) operated with a cycle of anaerobic - aerobic - anoxic - aerobic has been evaluated for the nutrient removal characteristics. The sponge-like moving media was filled to about 10% of reactor volume. The sewage was the major substrate while external synthetic carbon substrate was added to the anoxic stage to enhance the nitrogen removal. The operational results indicated that maximum T-N and T-P removal efficiencies were 97% and 94%, respectively were achieved, while COD removal of 92%. The observations of significant nitrogen removal in the first aerobic stage indicated that nitrogen removal behaviour in this SBBR was different to conventional SBR. Although the reasons for aerobic nitrogen removal has speculated to either simultaneous nitrification and denitrification or anoxic denitrification inside of the media, further researches are required to confirm the observation. The specific oxygen uptake rate (SOUR) test with biofilm and suspended growth sludge indicated that biofilm in SBBR played a major role to remove substrates.

Evaluation of Affecting Factors on N and P removal in Biological SND (Simultaneous Nitrification and Denitrification) Process with NADH Sensor (NADH 센서를 이용한 생물학적 동시 탈질.질산화공정에서 질소, 인제거 영향인자 및 거동 평가)

  • Kim, Han-Lae;Lee, Si-Jin
    • Journal of Environmental Health Sciences
    • /
    • v.34 no.5
    • /
    • pp.374-381
    • /
    • 2008
  • In this study, the factors affecting biological N and P removal using SND (simultaneous nitrification and denitrification) process were investigated and evaluated to examine the possibility of treating N and P through SND with NADH by surveying N and P traces in an aeration tank. Variations of $NH_4^+$-N+$NO_3^-$-N concentration were used to estimate the degree of SND in each point (P2, P3, P4, P5) of the aeration tank and these variations showed that denitrification efficiency in P2 (front zone), nitrification and denitrification efficiencies in P4 (middle zone) were 67%, 86% and 39%, respectively. When $PO_4^{-3}$-P concentration was analyzed in each point of the aeration tank, it was shown that $PO_4^{-3}$-P concentration coming into P2 was 1.25 mg/L, which increased to 2.22 mg/L by P release in P2 zone and then decreased to 0.74 mg/L by P uptake in P4. Consequently, we were able to estimate which high P removal efficiency observed in this study was caused by biological phosphorus removal. To determine the operating factors affecting effluent T-N, we analyzed the correlation among FN/M ratio, C/N ratio, Temp., SRT etc and these results showed that the correlation among FN/M ratio, C/N ratio and Temp was not high. However, the relationship of SRT and other parameters (effluent $NH_4^+$-N and effluent BOD) and the short SRT could have an affect on effluent $NH_4^+$-N and so effluent BOD could be increased. Thus, SRT operation should be controlled over 10 days. The results for analyzing the correlation between SRT and influent $NO_3^-$-N in order to investigate the operating factors affecting effluent T-P showed that T-P or $PO_4^{-3}$-P was not highly correlation with SRT, whereas $PO_4^{-3}$-P concentration increased along with increasing $NO_3^-$-N concentration into P2. Based on these results, we concluded, using regression analysis (R2=0.97), that effluent $PO_4^{-3}$-P concentration depends on $NO_3^-$-N concentration into P2.

A Study on Nitrogen and Phosphorus Removal in FNR Process (FNR process를 이용한 하수처리장의 질소.인의 제거에 관한 연구)

  • Cho Il-Hyoung;Lee Nae-Hyun;Lee Seung-Mok;Kim Young-Kyu
    • Journal of Environmental Science International
    • /
    • v.15 no.6
    • /
    • pp.571-577
    • /
    • 2006
  • This study make a comparison between the phosphorus removal performance of FNR(Ferrous Nutrient Removal) process and A/O process by the laboratory experiments. For simultaneous removal of phosphorus, iron electrolysis was combined with oxic tank. Iron precipitation reactor on the electrochemical behaviors of phosphorus in the iron bed. The phosphorus removal in FNR process was more than A/O process. Iron salts produced by iron electrolysis might help to remove COD and nitrogen. And the demanded longer SRT is the more removes the removes COD, nitrogen, and phosphorus. Also, FNR process of sludge quantity more reduce than A/O process to input cohesive agents.

Effect of the Total Organic Carbon(TOC) on phosphorus removal by Stapylococcus auricularis (Stapylococcus auricularis에 의한 인 제거에서 총유기탄소의 영향)

  • 최석순
    • Journal of environmental and Sanitary engineering
    • /
    • v.15 no.3
    • /
    • pp.57-61
    • /
    • 2000
  • Stapylococcus auricularis was used for the simultaneous removal of phosphorus and Total Organic Carbon(TOC) in the wastewater from sewage and various industries. In this study, the characteristics of phosphorus removal was investigated with initial ratio of TOC phosphorus in the synthetic wastewater. When the synthetic wastewater containing 15mg/L of phosphorus was treated under anaerobic and conditions, phosphorus was removed completely within 6 hours of operation. And when the initial ratio of TOC to phosphorus was 30, as high as 10 times the removal rate of phosphorus by Acinetobacter calcoaceticus was achieved. These results implied that a long adaptation time, one of the chief problems in biological phosphorus removal process was overcome.

  • PDF

Removal of acetic acid from wastewater by esterification in the membrane reactor

  • Unlu, Derya;Hilmioglu, Nilufer Durmaz
    • Membrane and Water Treatment
    • /
    • v.7 no.2
    • /
    • pp.143-154
    • /
    • 2016
  • Acetic acid can be removed from wastewater by esterification in a membrane reactor. Pervaporation membrane reactor (PVMR) is an alternative process to conventional separation processes. It is an environmentally friendly process. The main advantages of the PVMR are simultaneous water removal and production of an ester economically. In this study, the synthetic wastewater has been used. Esterification reaction of acetic acid with isopropanol has been studied in the presence of tungstosilicic acid hydrate as a catalyst in a batch reactor and in a PVMR. The effects of important operating parameters such as reaction temperature, initial molar ratio of isopropanol to acetic acid and catalyst concentration has been examined. Removal of acetic acid (conversion of acetic acid) was obtained as 85% using a PVMR by removal of water from the reaction mixture.

Simultaneous Nitrification and Denitrification by Anaerobic-Aerobic Biological Packed Bed Process

  • Lee, Min-Gye;Ju, Chang-Sik;Lee, Byung-Hyun;Kim, Jung-Kyun;Tadashi Hano
    • Journal of Life Science
    • /
    • v.9 no.2
    • /
    • pp.40-43
    • /
    • 1999
  • In the wastewater treatment experiment by anaerobic-aerobic packed bed unit, it was found that the high and stable removal efficiency of nitrogen could be obtained. The extent of nitrogen removal gradually decreased with the rise of recycle ratio and DO concentration. On the other hand, the extent of phosphorus increased with the increase of DO concentration. COD showed high removal efficiency over the entire range tested. The simulation of T-N behavior was carried out satisfactorily by using the kinetic equations for biofilm and the reactor model which considered the packed bed as a plug flow reactor.

Simultaneous N-P Removal of Wastewater with Flow Variation by Anaerobic-Aerobic Activated Sludge Process(I) (혐기-호기 활성슬러지법에 의한 유량변동이 있는 폐수의 N-P 동시 제거에 관한 연구(I))

  • 이민규;서근학
    • Journal of Environmental Science International
    • /
    • v.4 no.5
    • /
    • pp.509-516
    • /
    • 1995
  • The treatment performances of anaerobic-aerobic activated sludge process were investigated under various operation conditions. The treatment system proposed in this study gave a relatively stable performance against hourly change of the flow rate and showed a satisfactory removal of nitrogen and phosphorus compounds under experimental conditions. The recycle ratio of mixed liquor from aerobic to anaerobic region and peak coefficient primarily controlled the extent of nitrogen removal. The recycle ratio had the optimum values which were determined by the microbial activities of nitrification and denitrification. The behavior of the treatment unit could be simulated by using the kinetic equations and reactor models which considered the treatment units as complete mixing tanks.

  • PDF

Simultaneous N-P Removal of Wastewater with Flow Variation by Anaerobic-Aerobic Activated Sludge Process(I) (혐기-호기 활성슬러지법에 의한 유량변동이 있는 폐수의 N-P 동시 제거에 관한 연구(I))

  • Lee, Min-Gyu;Suh, Kuen-Hack
    • Journal of Environmental Science International
    • /
    • v.4 no.5
    • /
    • pp.123-123
    • /
    • 1995
  • The treatment performances of anaerobic-aerobic activated sludge process were investigated under various operation conditions. The treatment system proposed in this study gave a relatively stable performance against hourly change of the flow rate and showed a satisfactory removal of nitrogen and phosphorus compounds under experimental conditions. The recycle ratio of mixed liquor from aerobic to anaerobic region and peak coefficient primarily controlled the extent of nitrogen removal. The recycle ratio had the optimum values which were determined by the microbial activities of nitrification and denitrification. The behavior of the treatment unit could be simulated by using the kinetic equations and reactor models which considered the treatment units as complete mixing tanks.

Simultaneous Biofiltration of H2S, NH3 and Toluene using an Inorganic/Polymeric Composite Carrier

  • Park, Byoung-Gi;Shin, Won-Sik;Chung, Jong-Shik
    • Environmental Engineering Research
    • /
    • v.13 no.1
    • /
    • pp.19-27
    • /
    • 2008
  • Simultaneous removal of ternary gases of $NH_3$, $H_2S$ and toluene in a contaminated air stream was investigated over 180 days in a biofilter. A commercially available inorganic/polymeric composite chip with a large void volume (bed porosity > 0.80) was used as a microbial support. Multiple microorganisms including Nitrosomonas and Nitrobactor for nitrogen removal, Thiobacillus thioparus (ATCC 23645) for $H_2S$ removal and Pseudomonas aeruginosa (ATCC 15692), Pseudomonas putida (ATCC 17484) and Pseudomonas putida (ATCC 23973) for toluene removal were used simultaneously. The empty bed residence time (EBRT) ranged from 60 - 120 seconds and the inlet feed concentration was $0.0325\;g/m^3-0.0651\;g/m^3$ for $NH_3$, $0.0636\;g/m^3-0.141\;g/m^3$ for $H_2S$, and $0.0918\;g/m^3-0.383\;g/m^3$ for toluene, respectively. The observed removal efficiency was 2% - 98% for $NH_3$, 2% - 100% for $H^2S$, and 2% - 80% for toluene, respectively. Maximum elimination capacity was about $2.7\;g/m^3$/hr for $NH_3$, > $6.4\;g/m^3$/hr for $H_2S$ and $4.0\;g/m^3$/hr for toluene, respectively. The inorganic/polymeric composite carrier required 40 - 80 days of wetting time for biofilm formation due to the hydrophobic nature of the carrier. Once the surface of the carrier was completely wetted, the microbial activity became stable. During the long-term operation, pressure drop was negligible because the void volume of the carrier was two times higher than the conventional packing materials.