• Title/Summary/Keyword: simultaneous quantification

Search Result 225, Processing Time 0.021 seconds

Development of a Simultaneous Analytical Method for Determination of Herbicide Fenquinotrione and KIH-3653-M-2 Residues in Agricultural Crops using LC-MS/MS (LC-MS/MS를 이용한 농산물 중 제초제 fenquinotrione 및 대사산물 KIH-3653-M-2 동시시험법 개발)

  • Park, Ji-Su;Do, Jung-Ah;Lee, Han Sol;Cho, Sung Min;Shin, Hye-Sun;Jang, Dong Eun;Jung, Yong-hyun;Lee, Kangbong
    • Journal of Food Hygiene and Safety
    • /
    • v.34 no.3
    • /
    • pp.242-250
    • /
    • 2019
  • An analytical method was developed for the determination of fenquinotrione, a triketone herbicide, in agricultural products. Fenquinotrione was metabolized to KIH-3653-M-2 in plants. Analyte extraction was conducted using 2% formic acid in acetonitrile and cleaned up using a hydrophillic-lipophillic balance (HLB) cartridge. The limits of detection (LOD) and quantification (LOQ) were 0.004 and 0.01 mg/kg, respectively. Matrix-matched calibration curves were linear over the calibration ranges ($0.001{\sim}0.1{\mu}g/mL$) into a blank extract with $r^2>0.99$. The recovery results for fenquinotrione and KIH-3653-M-2 ranged between 81.1 to 116.2% and 78.0 to 110.0% at different concentration levels (LOQ, $10{\times}LOQ$, $50{\times}LOQ$) with relative standard deviation (RSD) less than 4.6%. All values were corresponded with the criteria ranges requested in both the Codex (CAC/GL 40-1993, 2003) and MFDS guidelines (2016). Therefore, the proposed method can be used as an official analytical method for determination of fenquinotrione in the Republic of Korea.

Simultaneous Multicomponent Analysis of Preservatives in Cosmetics by Gas Chromatography (GC를 이용한 화장품 살균·보존제의 다성분 동시분석법)

  • Cho, Sang Hun;Jung, Hong Rae;Kim, Young Sug;Kim, Yang Hee;Park, Eun Mi;Shin, Sang Woon;Eum, Kyoung Suk;Hong, Se Ra;Kang, Hyo Jeong;Yoon, Mi Hye
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.45 no.1
    • /
    • pp.69-75
    • /
    • 2019
  • Preservatives of cosmetics is managed by positive list in Korea. Positive list requires a proper quantitative analysis method, but the analysis method is still insufficient. In this study, gas chromatography with flame ionization detector was used to simultaneously analyze 14 preservatives in cosmetics. As a result of method validation, the specificity was confirmed by the calibration curves of 14 preservatives showing good linearity correlation coefficient of above 0.9997 except dehydroacetic acid (0.9891). The limits of detection (LOD) and quantification (LOQ) of 14 preservatives were 0.0001 mg/mL ~ 0.0039 mg/mL and 0.0003 mg/mL ~ 0.0118 mg/mL, respectively, but they were 0.0204 mg/mL, 0.0617 mg/mL for dehydroacetic acid, respectively. The precision (Repeatability) of the values was less than 1.0%, but 7.1% for dehydroacetic acid. The Accuracy (% recovery) of 14 preservatives in cosmetics showed 96.9% ~ 109.2%. Finally, this method was applied to 50 cosmetics available in market. Results showed that the commonly used preservatives were chlorophene, phenoxyethanol, benzyl alcohol and parabens. However, the amount of the detected preservatives was within maximum allowed limits established by KFDA.

A Refined Method for Quantification of Myocardial Blood Flow using N-13 Ammonia and Dynamic PET (N-13 암모니아와 양전자방출단층촬영 동적영상을 이용하여 심근혈류량을 정량화하는 새로운 방법 개발에 관한 연구)

  • Kim, Joon-Young;Lee, Kyung-Han;Kim, Sang-Eun;Choe, Yearn-Seong;Ju, Hee-Kyung;Kim, Yong-Jin;Kim, Byung-Tae;Choi, Yong
    • The Korean Journal of Nuclear Medicine
    • /
    • v.31 no.1
    • /
    • pp.73-82
    • /
    • 1997
  • Regional myocardial blood flow (rMBF) can be noninvasively quantified using N-13 ammonia and dynamic positron emission tomography (PET). The quantitative accuracy of the rMBF values, however, is affected by the distortion of myocardial PET images caused by finite PET image resolution and cardiac motion. Although different methods have been developed to correct the distortion typically classified as partial volume effect and spillover, the methods are too complex to employ in a routine clinical environment. We have developed a refined method incorporating a geometric model of the volume representation of a region-of-interest (ROI) into the two-compartment N-13 ammonia model. In the refined model, partial volume effect and spillover are conveniently corrected by an additional parameter in the mathematical model. To examine the accuracy of this approach, studies were performed in 9 coronary artery disease patients. Dynamic transaxial images (16 frames) were acquired with a GE $Advance^{TM}$ PET scanner simultaneous with intravenous injection of 20 mCi N-13 ammonia. rMBF was examined at rest and during pharmacologically (dipyridamole) induced coronary hyperemia. Three sectorial myocardium (septum, anterior wall and lateral wall) and blood pool time-activity curves were generated using dynamic images from manually drawn ROIs. The accuracy of rMBF values estimated by the refined method was examined by comparing to the values estimated using the conventional two-compartment model without partial volume effect correction rMBF values obtained by the refined method linearly correlated with rMBF values obtained by the conventional method (108 myocardial segments, correlation coefficient (r)=0.88). Additionally, underestimated rMBF values by the conventional method due to partial volume effect were corrected by theoretically predicted amount in the refined method (slope(m)=1.57). Spillover fraction estimated by the two methods agreed well (r=1.00, m=0.98). In conclusion, accurate rMBF values can be efficiently quantified by the refined method incorporating myocardium geometric information into the two-compartment model using N-13 ammonia and PET.

  • PDF

Development of a Simultaneous Analytical Method for Determination of Insecticide Broflanilide and Its Metabolite Residues in Agricultural Products Using LC-MS/MS (LC-MS/MS를 이용한 농산물 중 살충제 Broflanilide 및 대사물질 동시시험법 개발)

  • Park, Ji-Su;Do, Jung-Ah;Lee, Han Sol;Park, Shin-min;Cho, Sung Min;Kim, Ji-Young;Shin, Hye-Sun;Jang, Dong Eun;Jung, Yong-hyun;Lee, Kangbong
    • Journal of Food Hygiene and Safety
    • /
    • v.34 no.2
    • /
    • pp.124-134
    • /
    • 2019
  • An analytical method was developed for the determination of broflanilide and its metabolites in agricultural products. Sample preparation was conducted using the QuEChERS (Quick, Easy, Cheap, Effective, Rugged and Safe) method and LC-MS/MS (liquid chromatograph-tandem mass spectrometer). The analytes were extracted with acetonitrile and cleaned up using d-SPE (dispersive solid phase extraction) sorbents such as anhydrous magnesium sulfate, primary secondary amine (PSA) and octadecyl ($C_{18}$). The limit of detection (LOD) and quantification (LOQ) were 0.004 and 0.01 mg/kg, respectively. The recovery results for broflanilide, DM-8007 and S(PFP-OH)-8007 ranged between 90.7 to 113.7%, 88.2 to 109.7% and 79.8 to 97.8% at different concentration levels (LOQ, 10LOQ, 50LOQ) with relative standard deviation (RSD) less than 8.8%. The inter-laboratory study recovery results for broflanilide and DM-8007 and S (PFP-OH)-8007 ranged between 86.3 to 109.1%, 87.8 to 109.7% and 78.8 to 102.1%, and RSD values were also below 21%. All values were consistent with the criteria ranges requested in the Codex guidelines (CAC/GL 40-1993, 2003) and the Food and Drug Safety Evaluation guidelines (2016). Therefore, the proposed analytical method was accurate, effective and sensitive for broflanilide determination in agricultural commodities.

Improvement and Validation of an Analytical Method for Quercetin-3-𝑜-gentiobioside and Isoquercitrin in Abelmoschus esculentus L. Moench (오크라 분말의 Quercetin-3-𝑜-Gentiobioside 및 Isoquercitrin의 분석법 개선 및 검증)

  • Han, Xionggao;Choi, Sun-Il;Men, Xiao;Lee, Se-jeong;Jin, Heegu;Oh, Hyun-Ji;Cho, Sehaeng;Lee, Boo-Yong;Lee, Ok-Hwan
    • Journal of Food Hygiene and Safety
    • /
    • v.37 no.2
    • /
    • pp.39-45
    • /
    • 2022
  • This study aimed to investigate the validation and modify the analytical method to determine quercetin-3-𝑜-gentiobioside and isoquercitrin in Abelmoschus esculentus L. Moench for the standardization of ingredients in development of functional health products. The analytical method was validated based on the ICH (International Conference for Harmonization) guidelines to verify the reliability and validity there of on the specificity, linearity, accuracy, precision, detection limit and quantification limit. For the HPLC analysis method, the peak retention time of the index component of the standard solution and the peak retention time of the index component of A. esculentus L. Moench powder sample were consistent with the spectra thereof, confirming the specificity. The calibration curves of quercetin-3-𝑜-gentiobioside and isoquercitrin showed a linearity with a near-one correlation coefficient (0.9999 and 0.9999), indicating the high suitability thereof for the analysis. A. esculentus L. Moench powder sample of a known concentration were prepared with low, medium, and high concentrations of standard substances and were calculated for the precision and accuracy. The precision of quercetin-3-𝑜-gentiobioside and isoquercitrin was confirmed for intra-day and daily. As a result, the intra-day precision was found to be 0.50-1.48% and 0.77-2.87%, and the daily precision to be 0.07-3.37% and 0.58-1.37%, implying an excellent precision at level below 5%. As a result of accuracy measurement, the intra-day accuracy of quercetin-3-𝑜-gentiobioside and isoquercitrin was found to be 104.87-109.64% and the daily accuracy thereof was found to be 106.85-109.06%, reflecting high level of accuracy. The detection limits of quercetin-3-𝑜-gentiobioside and isoquercitrin were 0.24 ㎍/mL and 0.16 ㎍/mL, respectively, whereas the quantitation limits were 0.71 ㎍/mL and 0.49 ㎍/mL, confirming that detection was valid at the low concentrations as well. From the analysis, the established analytical method was proven to be excellent with high level of results from the verification on the specificity, linearity, precision, accuracy, detection limit and quantitation limit thereof. In addition, as a result of analyzing the content of A. esculentus L. Moench powder samples using a validated analytical method, quercetin-3-𝑜-gentiobioside was analyzed to contain 1.49±0.01 mg/dry weight g, while isoquercitrin contained 1.39±0.01 mg/dry weight g. The study was conducted to verify that the simultaneous analysis on quercetin-3-𝑜-gentiobioside and isoquercitrin, the indicators of A. esculentus L. Moench, is a scientifically reliable and suitable analytical method.