• Title/Summary/Keyword: simultaneous placement

Search Result 75, Processing Time 0.024 seconds

Design of a Low-order Pole Placement Power System Stabilizer Using Simultaneous Stabilization (동시안정화를 이용한 저차원 극배치 전력계통안정화장치 설계)

  • Kim, Seog-Joo;Lee, Jong-Moo;Kwon, Soon-Man
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.10
    • /
    • pp.1708-1712
    • /
    • 2008
  • This paper describes a linear matrix inequality (LMI) approach to the design of robust low-order power system stabilizers (PSSs), which are used to damp out local-mode oscillations of synchronous generators. The performance of a PSS is expressed as the location of the closed-loop poles, and a single fixed-gain pole-placement controller is synthesized for a wide range of operating conditions. The synthesis results in simultaneous regional pole-placement stabilization. and is formulated as an LMI feasibility problem with a rank condition. A penalty method is applied to solve the rank-constrained LMI problem. Numerical experiments with a single-machine connected to an infinite bus system were performed to demonstrate the proposed method.

Bone-added osteotome sinus floor elevation with simultaneous placement of non-submerged sand blasted with large grit and acid etched implants: a 5-year radiographic evaluation

  • Jung, Jee-Hee;Choi, Seong-Ho;Cho, Kyoo-Sung;Kim, Chang-Sung
    • Journal of Periodontal and Implant Science
    • /
    • v.40 no.2
    • /
    • pp.69-75
    • /
    • 2010
  • Purpose: Implant survival rates using a bone-added osteotome sinus floor elevation (BAOSFE) procedure with simultaneous placement of a non-submerged sand blasted with large grit and acid etched (SLA) implant are well documented at sites where native bone height is less than 5 mm. This study evaluated the clinical results of non-submerged SLA Straumann implants placed at the time of the BAOSFE procedure at sites where native bone height was less than 4 mm. Changes in graft height after the BAOSFE procedure were also assessed using radiographs for 5 years after the implant procedure. Methods: The BAOSFE procedure was performed on 4 patients with atrophic posterior maxillas with simultaneous placement of 7 non-submerged SLA implants. At least 7 standardized radiographs were obtained from each patient as follows: before surgery, immediately after implant placement, 6 months after surgery, every year for the next 3 years, and after more than 5 years had passed. Clinical and radiographic examinations were performed at every visit. Radiographic changes in graft height were calculated with respect to the implant's known length and the original sinus height. Results : All implants were stable functionally, as well as clinically and radiographically, during the follow-up. Most of the radiographic reduction in the grafted bone height occurred in the first 2 years; reduction after 2 years was slight. Conclusions: The simultaneous placement of non-submerged SLA implants using the BAOSFE procedure is a feasible treatment option for patients with severe atrophic posterior maxillas. However, the grafted bone height is reduced during the healing period, and patients must be selected with care.

Simultaneous Hard Tissue and Soft Tissue Graft with Dental Implant Placement and Provisionalization: A Case Report

  • Hyunjae Kim;Young-Dan Cho;Sungtae Kim
    • Journal of Korean Dental Science
    • /
    • v.17 no.2
    • /
    • pp.84-91
    • /
    • 2024
  • Achieving both esthetic and functional implant rehabilitation is crucial for the successful treatment of the anterior maxilla. Adequate peri-implant alveolar bone and soft tissue are essential for optimal rehabilitation of the esthetic area, and there is a direct association between the implant position and prosthetic outcomes. Immediate provisionalization may also be advantageous when combined with augmentation. This case report described the implant placement in a 25-year-old female patient who had lost her right maxillary lateral incisor (#12) due to trauma-induced avulsion. The treatment involved simultaneous grafting and collagenated, deproteinized bovine bone mineral, along with subepithelial connective tissue taken from the right maxillary tuberosity. A polyetheretherketone abutment and non-functional immediate provisionalization were performed by removing both the proximal and occlusal contacts on the composite resin crown. Clinical and radiographic evaluations revealed maintenance of stable ridge contour aspects for six months following surgical treatment. In summary, implant rehabilitation in the esthetic zone can be successful using simultaneous soft and hard tissue grafts. Moreover, soft tissue stabilization post-subepithelial connective tissue grafting can be achieved through early or immediate visualization, along with immediate implant placement.

Percutaneous Enteral Stent Placement Using a Transhepatic Access for Palliation of Malignant Bowel Obstruction after Surgery

  • Won Seok Choi;Chang Jin Yoon;Jae Hwan Lee
    • Korean Journal of Radiology
    • /
    • v.22 no.5
    • /
    • pp.742-750
    • /
    • 2021
  • Objective: To assess the safety and clinical efficacy of percutaneous transhepatic enteral stent placement for recurrent malignant obstruction in patients with surgically altered bowel anatomy. Materials and Methods: Between July 2009 and May 2019, 36 patients (27 men and 9 women; mean age, 62.7 ± 12.0 years) underwent percutaneous transhepatic stent placement for recurrent malignant bowel obstruction after surgery. In all patients, conventional endoscopic peroral stent placement failed due to altered bowel anatomy. The stent was placed with a transhepatic approach for an afferent loop obstruction (n = 27) with a combined transhepatic and peroral approach for simultaneous stent placement in afferent and efferent loop obstruction (n = 9). Technical and clinical success, complications, stent patency, and patient survival were retrospectively evaluated. Results: The stent placement was technically successful in all patients. Clinical success was achieved in 30 patients (83.3%). Three patients required re-intervention (balloon dilatation [n = 1] and additional stent placement [n = 2] for insufficient stent expansion). Major complications included transhepatic access-related perihepatic biloma (n = 2), hepatic artery bleeding (n = 2), bowel perforation (n = 1), and sepsis (n = 1). The 3- and 12-months stent patency and patient survival rates were 91.2%, 66.5% and 78.9%, 47.9%, respectively. Conclusion: Percutaneous enteral stent placement using transhepatic access for recurrent malignant obstruction in patients with surgically altered bowel anatomy is safe and clinically efficacious. Transhepatic access is a good alternative route for afferent loop obstruction and can be combined with a peroral approach for simultaneous afferent and efferent loop obstruction.

Sinus floor elevation and simultaneous implant placement in fresh extraction sockets: a systematic review of clinical data

  • Ekhlasmandkermani, Mehdi;Amid, Reza;Kadkhodazadeh, Mahdi;Hajizadeh, Farhad;Abed, Pooria Fallah;Kheiri, Lida;Kheiri, Aida
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.47 no.6
    • /
    • pp.411-426
    • /
    • 2021
  • Combining different procedures to reduce the number of surgical sessions and patient discomfort in implant placement and sinus floor elevation has been recommended, and evidence supports good outcomes. The aim of this study was to review the results of clinical studies on sinus floor elevation through extraction sockets and simultaneous immediate posterior implant placement. An electronic search was carried out in PubMed, Scopus, and Web of Science to find English articles published in or before August 2020. A manual search was also performed. Titles, abstracts, and the full-text of the retrieved articles were studied. Thirteen studies met our eligibility criteria: 6 retrospective case series, 3 case reports, 2 prospective cohort case-series, 1 prospective case series, and 1 randomized controlled trial. Overall, 306 implants were placed; 2 studies reported implant survival rates of 91.7% and 98.57%. The others either did not report the survival rate or reported 100% survival. Sinus floor elevation through a fresh extraction socket and simultaneous immediate implant placement appears to be a predictable modality with a high success rate. However, proper case selection and the expertise of the clinician play fundamental roles in the success of such complex procedures.

Simultaneous placement of an interpositional free gingival graft with nonsubmerged implant placement

  • Sohn, Joo-Yeon;Park, Jung-Chul;Cho, Kyoo-Sung;Kim, Chang-Sung
    • Journal of Periodontal and Implant Science
    • /
    • v.44 no.2
    • /
    • pp.94-99
    • /
    • 2014
  • Purpose: Various surgical techniques target achieving adequate keratinized tissue around dental implants; however, these techniques are usually performed before implant placement or upon the exposure of submerged implants. The aim of this case report is to describe a simultaneous placement of an interpositional free gingival graft (iFGG) with that of nonsubmerged implants in a patient lacking keratinized tissue and to assess the longterm outcome of this grafted gingiva. Methods: A wedge-shaped free gingnival graft (FGG), including an epithelium-connective tissue (E-C) portion and a connective-tissue-only (CT) portion, was harvested from the palate. The CT portion was inserted under the buccal flap, and the E-C portion was secured tightly around the implants and to the lingual flap. Results: At the 8-year follow-up, the gingival graft remained firmly attached and was well maintained, with no conspicuous shrinkage or reported discomfort during oral hygiene procedures. The use of an iFGG at a nonsubmerged implant placement minimizes the required number of surgical steps and patient discomfort while providing adequate buccal keratinized tissue. Conclusions: Therefore, the technique could be considered an alternative method in increasing the keratinized tissue for cases that have a minimal amount of keratinized tissue.

MAXILLARY SINUS ELEVATION PROCEDURES: A Report of Six Cases (상악동거상술 및 임플란트매식에 의한 상악 구치부 수복에 관한 임상적 연구)

  • Lee, Dong-Han
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.33 no.2
    • /
    • pp.300-316
    • /
    • 1995
  • Methods for restoring the posterior portion of the maxilla with delayed and simultaneous sinus lift, composite graft and placement of TPS cylinder and screw type implants are presented. Sinus grafting is needed because of minimal remaining alveolar bone and supporting posterior maxillary portion, The composite graft material uses a combination of autogeneous bone from tuberosity, dimeneralized freeze dried allogenic bone and hydroxylapatite with saline. Since 1991, feb, 1 sinus graft with delayed implantation of 3 cylinder implants and 5 sinus grafts with simultaneous placement of 4HA coated screw typed, 8 TPS cylinder typed implants have been performed for 6 patients. None of the 15 restored implants have been lost, Temporization of prosthesis was done about 2-5 months before final prosthetic work, None of them shows any severe complication.

  • PDF

Delayed Occurrence of Maxillary Sinusitis after Simultaneous Maxillary Sinus Augmentation and Implant: A Case Report and Literature Review (상악동 거상술을 동반한 임플란트 식립 후 지연성으로 발생한 상악동염에 대한 고찰)

  • Lee, Jae-Hoon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.35 no.1
    • /
    • pp.60-65
    • /
    • 2013
  • The maxillary floor sinus augmentation is considered as a safe and predictable procedure to ensure optimal implant placement. However, this procedure may have a variety of intra-surgical or post-surgical complications, also the major drawback of the procedure is deemed maxillary sinusitis. This case is a very unusual delayed occurrence of acute maxillary sinusitis after simultaneous maxillary sinus augmentation, using xenograft and implant placement. This report describes a serious complication of the maxillary sinus augmentation.

Simultaneous implant placement with sinus augmentation using a modified lateral approach in the pneumatized posterior maxilla: A Case Report (함기화된 상악 구치부에서 변형 측방 접근법을 이용한 상악동 거상술과 임플란트 동시식립에 대한 증례보고)

  • Sun, Yoo-Kyung;Cha, Jae-Kook;Lee, Jung-Seok;Jung, Ui-Won
    • The Journal of the Korean dental association
    • /
    • v.56 no.3
    • /
    • pp.142-150
    • /
    • 2018
  • In the posterior maxillary area, due to resorption of the ridge after extraction and pneumatization of the maxillary sinus, the height of the alveolar ridge may not be sufficient for placement of implants. To solve this problem, sinus augmentation using both crestal and lateral approaches have been widely used. Jung et al. (2010) introduced the modified lateral approach technique, which is a simplified technique that combines the advantages of crestal and lateral approaches. The purpose of this case report is to report two cases in the posterior maxilla in which simultaneous implant placement with maxillary sinus augmentation has been performed using the modified lateral approach technique. In two female patients, 67 and 74 years old, respectively, simultaneous implant placement was performed using the modified lateral approach technique on the left maxillary second premolar and the first molar. In both patients, the residual bone height on the distal side of the maxillary second premolar was measured to be approximately 5 mm, and the residual bone height of the first molar was measured to be 2-3 mm. After flap elevation, osteotomy of the lateral window was performed in the form of a mesiodistally extended slot above the sinus floor and the Schneiderian membrane was elevated. Sequenced drilling was performed while protecting the membrane with a periosteal elevator. Bone graft and implant placement was performed after preparation of the implant site. Sufficient primary stability was achieved for each implant and sinus membrane was not perforated. After four and five months respectively, implant second surgery was performed. Clinically, the implants were observed to be stable. Implants and surrounding peri-implant mucosa were well maintained after prosthodontic treatment. In conclusion, the modified lateral approach could be a predictable and efficient technique for implant placement in the atrophied posterior maxilla.

  • PDF

Multi-type, multi-sensor placement optimization for structural health monitoring of long span bridges

  • Soman, Rohan N.;Onoufrioua, Toula;Kyriakidesb, Marios A.;Votsisc, Renos A.;Chrysostomou, Christis Z.
    • Smart Structures and Systems
    • /
    • v.14 no.1
    • /
    • pp.55-70
    • /
    • 2014
  • The paper presents a multi-objective optimization strategy for a multi-type sensor placement for Structural Health Monitoring (SHM) of long span bridges. The problem is formulated for simultaneous placement of strain sensors and accelerometers (heterogeneous network) based on application demands for SHM system. Modal Identification (MI) and Accurate Mode Shape Expansion (AMSE) were chosen as the application demands for SHM. The optimization problem is solved through the use of integer Genetic Algorithm (GA) to maximize a common metric to ensure adequate MI and AMSE. The performance of the joint optimization problem solved by GA is compared with other established methods for homogenous sensor placement. The results indicate that the use of a multi-type sensor system can improve the quality of SHM. It has also been demonstrated that use of GA improves the overall quality of the sensor placement compared to other methods for optimization of sensor placement.