• Title/Summary/Keyword: simultaneous measurement

Search Result 482, Processing Time 0.029 seconds

Performance Characteristics of CA 19-9 Radioimmunoassay and Clinical Significance of Serum CA 19-9 Assay in Patients with Malignancy (CA 19-9 방사면역측정법의 기본적 검토 및 악성종양환자에서의 혈청 CA 19-9치의 임상적 의의에 관한 연구)

  • Kim, Sang-Eun;Shong, Young-Kee;Cho, Bo-Youn;Kim, Noe-Kyeong;Koh, Chang-Soon;Lee, Mun-Ho;Hong, Seong-Woon;Hong, Kee-Suk
    • The Korean Journal of Nuclear Medicine
    • /
    • v.19 no.1
    • /
    • pp.119-126
    • /
    • 1985
  • To evaluate the performance characteristics of CA 19-9 radioimmunoassay and the clinical significance of serum CA 19-9 assay in patients with malignancy, serum CA 19-9 levels were measured by radioimmunoassay using monoclonal antibody in 135 normal controls, 81 patients with various untreated malignancy, 9 patients of postoperative colon cancer without recurrence and 20 patients with benign gastrointestinal diseases, who visited Seoul National University Hospital from June, 1984 to March, 1985. The results were as follows; 1) The CA 19-9 radioimmunoassay was simple to perform and can be completed in one work day. And the between-assay reproducibility and the assay recovery were both excellent. 2) The mean serum CA 19-9 level in 135 normal controls was $8.4{\pm}4.2U/mL$. Normal upper limit of serum CA 19-9 was defined as 21.0 U/mL. 4 out of 135(3.0%) normal controls showed elevated CA 19-9 levels above the normal upper limit. 3) One out of 20(5.0%) patients with benign gastrointestinal diseases showed elevated serum CA 19-9 level above the normal upper limit. 4) In 81 patients with various' untreated malignancy, 41 patients(50.6%) showed elevated serum CA 19-9 levels. 66.7% of 18 patients with colorectal cancer, 100% of 2 patients with pancreatic cancer, 100% of 3 patients with common bile duct cancer, 47.1% of 17 patients with stomach cancer, 28.6% of 28 patients with hepatoma and 60.0% of 5 other gastrointestinal tract cancers showed elevated serum CA 19-9 levels. 5) The sensitivities of serum CA 19-9 related to resectability in colorectal and stomach cancer were 33.3% in resectable colorectal cancer, 83.3% in unresectable colorectal cancer, 41.7% in resectable stomach cancer, 60.0% in unresectable stomach cancer respectively. 6) The sensitivity of serum CA 19-9 in 9 patients of postoperative colorectal cancer without recurrence were 33.3% and significantly decreased compared with that of untreated colorectal cancer, 66.7% (p<0.05). 7) In patients with colorectal cancer, simultaneous measurement of serum CA 19-9 and serum CEA levels increased sensitivities. From above results, we concluded that serum CA 19-9 radioimmunoassay is simple to perform and reproducible, and is a useful indicator reflecting tumor extent and responses to the treatment in patients with malignancy.

  • PDF

Comparative Analysis of Obesity by $\beta$-II, III, Adrenergic Receptor Gene Polymorphism in Korean Young Females ($\beta$-II, III Adrenergic Receptor 유전자 다형성에 따른 20대 한국여성의 식이 섭취량, 비만도 및 체성분의 비교연구)

  • 홍정미;김중학;박윤신;최선미;윤유식;안홍석
    • Journal of Nutrition and Health
    • /
    • v.35 no.8
    • /
    • pp.870-879
    • /
    • 2002
  • The purpose of this study was to investigate the obesity and state of dietary intake of 216 young Korean females, and the influence of $\beta$-II, III Adrenergic receptor (AR) gene polymorphism upon obesity and dietary intake. The average weight, height and BMI of the subjects were 160 cm, 54 kg, and 20.9 kg/$m^2$, respectively. The average triceps skinfold thickness, waist circumference, hip circumference and WHR were 21.7mm, 73.1cm, 93.3cm and 0.78, respectively. The results of body composition measurement using bioimpedance method, average body fluid, body protein, mineral mass and body fat were 29.271, 7.22 kg, 6.79 kg and 19.16 kg, respectively. A dietary survey was conducted using 24-hour recall method. Average calorie intake was 1621 ㎉, which is 81% of Korean RDA. We detected 182 (84.3%) Gln27 (QQ) homozygotes and 34 (15.7%) Gln27Glu (QE) heterozygotes for $\beta$-II AR polymorphism. For $\beta$-III AR polymorphism, we detected 163 (75.5%) Trp64 (WW) and 53 (24.5%) Trp 64Arg (WR). The results of comparing of obesity by $\beta$-II AR gene polymorphism, obesity index and BMI of QE type were slightly higher than those of the QQ type. For $\beta$-III AR gene polymorphism, the mean BMI, obesity index, fat mass and percent body fat (%) of the WR type were significantly higher than those of the WW type (p < 0.05). These findings suggest that genetic variability in the human $\beta$-III AR is associated with obesity among young Korean females. We also evaluated the effect of the simultaneous presence of the $\beta$-II AR and $\beta$-III AR polymorphism on obesity. We found that the BMI and obesity index of the mutant type in both $\beta$-II AR and $\beta$-III AR were significantly higher than those of the type that has only one gene mutation or has no mutation (p < 0.05), indicating a synergistic effect of $\beta$-II AR and $\beta$-III AR polymorphism on obesity. No association was found between $\beta$-II Ad or $\beta$-III AR polymorphism and dietary intake.

SIMULTANEOUS OBSERVATIONS OF PI 2 PULSATIONS ON THE SATELLITE AND GROUND-BASED MEASUREMENTS (위성 및 지상자력계에서의 PI 2 파동 동시 관측)

  • 이성환;이동훈;김관혁
    • Journal of Astronomy and Space Sciences
    • /
    • v.14 no.2
    • /
    • pp.275-285
    • /
    • 1997
  • We have investigated Pi 2 pulsations which were observed both on ground magnetometer array and by satellites. On November 9th in 1994, Pi 2 pulsations appeared globally on the 190/210 magnetometer chain and Hermanus station when two satellites(EXOS-D and ETS-VI) were located near the magnetic meridian of the 210 array. The local time of measurements covers from morning(LT=8.47hr) to afternoon(LT=20.3hr) and the bandwidth of peak frequency is found relatively small. The signals of the electric field are highly coherent with ground-based observations with the out of phase oscillations. However, the magnetic field measurement on the ETS-VI in the outer magnetosphere(L=6.60) shows no signature of Pi 2 pulsations over the same time interval and the correlation with any of the ground-based stations is found to be very weak, even through both satellites and magnetometer chain are located close to each other in local time. We suggest that this event may be a direct evidence of Pi 2 pulsations as virtual resonant modes which are localized in the plasmasphere(Lee 1996). The results show that the cavity mode oscillations can occur in the inner magnetosphere with less spectral noise compared to the outer magnetospheric case.

  • PDF

Study of Optimized Simultaneous Extraction Conditions for Active Component of Ginseng Berry using Response Surface Methodology (반응표면분석을 이용한 진생베리의 활성 성분 최적 추출 조건에 관한 연구)

  • Go, Hee Kyoung;Park, Junseong
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.46 no.2
    • /
    • pp.185-194
    • /
    • 2020
  • This study was conducted to find out the optimal extraction conditions to obtain extracts with a high content of ginsenosides and antioxidant activity using the ginseng berry. After extraction by stirring, ultrasound and microwave method using 70% ethanol and distilled water as solvents, the results of considering the content of ginsenoside Re and Rb1, total polyphenol content, antioxidant activity, and whether it is an environmentally friendly manufacturing method, it was confirmed that the microwave method using distilled water is good method of extraction. The optimization of extraction conditions for microwave method were made by response surface methodology (RSM). Microwave power (50 ~ 200 W, X1), solvent and ginseng berry ratio (5 ~ 20 times, X2) and the extraction time (30 ~ 120 s, X3) were used as independent variables. The model showed a good fit having a determination coefficient of the regression equation of 0.9 or more and a p-value less than 0.05. Estimated conditions for the maximized extraction of ginsenoside contents and total polyphenols were 200 w in microwave power, 20 times in solvent and ginseng berry ratio, and 90 s in extraction time. Predicted values at the optimum conditions were total polyphenols of 6.23 mg GAE/g, ginsenoside Re of 17.69 mg/g, and ginsenoside Rb1 of 16.01 mg/g. In the verification of the actual measurement the obtained values showed 6.33 mg GAE/g, 17.79 mg/g, and 15.59 mg/g, respectively, in good agreement with predicted values.

Development of an Automated and Continuous Analysis System for PM2.5 and Chemical Characterization of the PM2.5 in the Atmosphere at Seoul (자동연속측정시스템 개발 및 이 시스템을 이용한 서울 대기 중 PM2.5의 화학적 조성과 특성에 관한 연구)

  • Lee Bo Kyoung;Kim Young Hoon;Ha Jae Yoon;Lee Dong Soo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.21 no.4
    • /
    • pp.439-458
    • /
    • 2005
  • An automated analysis system for water soluble constituents in $PM_{2.5}$ has been developed. The system consists of a high capacity multi tube diffusion scrubber (MTDS), a low temperature particle impactor (LTPI), and two ion (anion and cation) chromatography (IC) systems. Atmospheric particles have been collected by passing sample air through a thermostated MTDS followed by a LTPI. This system allows simultaneous measurements of soluble ions in $PM_{2.5}$ at 30 minutes interval. At the air sampling flow rate of 1.0L/min, the detection limits of the overall system are in the order of tens of $ng/m^3$. This system has been successfully used for the measurement of particulate components of Seoul air from April 2003 to January 2004. $SO_4^{2-},\;NO_3^-,\;NH_4^+,\;NO_2^-,\;Cl^-,\;Na^+,\;K^+,\;Ca^{2+},\;and\;Mg^{2+}$ are the major ionic species for $PM_{2.5}$ at Seoul. Among them, $SO_4^{2-},\;NO_3^-\;and\;NH_4^+$ are the most abundant ions, contributed up to $86\%$ of the total and the concentrations were higher than those in any other urban sites in the world except for Chinese cities. There are high pollutant episodes which contribute about $15\~20\%$ of annual average values of the major ions. During the episode, the all parcels were transported from the asian continent and $PM_{2.5}$ were significantly neutralized. This suggests that aged and long range transported pollutants caused the high pollutant episodes. They showed a distinct daily and seasonal variations:they showed a peak in the early morning caused by the night-time accumulation of particulate matters. Atmospheric reactions including gas-to-particle reactions and inter-particle reactions and meteorological parameters including relative humidity and ambient temperature were described with related to the $PM_{2.5}$ 5 concentrations. All of the ionic species showed higher concentrations during the spring than those for summer and winter.

A Study on Development of Power Analysing Device for PV Module (태양전지 모듈의 발전량 분석 장치 개발에 관한 연구)

  • Moon, Chae-Joo;Kwak, Seung-Hun;Jang, Yeong-Hak;Kim, Tae-Gon;Kim, Eui-Sun;Kim, Tae-Hyun
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.6
    • /
    • pp.73-80
    • /
    • 2010
  • This study was conducted to estimate the relative performance of modules with changed characteristics due to long term exposure to the outdoor environment, with a specially made test device for simultaneous measurement of real time power output from the photovoltaic array, taking into account the inclined panel, direct irradiation, power being generated, temperature as well as the optimal analysis timing. In terminology description, M is an abbreviation of module and Group A, Group B are 10 modules series connection (1~10 of M), (11~20 of M) for each of them respectively. The overall mean voltage difference of M-18 with the lowest power output and M-14 with the highest output is-2.13V and it was identifiable that voltage difference was more concentrated to Group B. In addition, in case of M-2 and M-7, M-8, when compared with M-14, the overall mean voltage difference was -0.92V, -1.56 and -0.91V respectively showing the more concentration to Group A. When the temperature of module went up by $1^{\circ}C$, the mean voltage was reduced by 0.35V. For current, Group A was lower than Group B by-0.022A and the ratio of each group was 49.68% and 50.32% respectively, presumably the module with deteriorated properties were more concentrated to Group A relatively. From the comparison of relations with the comprehensive accumulation, M-2, M-7, M-8, M-16 and M-18 were those with deterioration of performance to the worst, thereby requiring precision examination. In comparative efficiency, M-14 was the most excellent one as 12.19% while M-18 as 10.53% was identified that its efficiency was comparatively rapidly reduced.

Derivation and Evaluation of Surface Reflectance from UAV Multispectral Image for Monitoring Forest Vegetation (산림 식생 모니터링을 위한 무인기 다중분광영상의 반사율 산출 및 평가)

  • Lee, Hwa-Seon;Seo, Won-Woo;Woo, Choongshik;Lee, Kyu-Sung
    • Korean Journal of Remote Sensing
    • /
    • v.35 no.6_2
    • /
    • pp.1149-1160
    • /
    • 2019
  • In this study, two radiometric correction methods deriving reflectance from UAV multispectral image for monitoring forest vegetation were applied and evaluated. Multispectral images were obtained from a small multispectral camera having 5 spectral bands. Reflectance were derived by applying the two methods: (1) the direct method using downwelling irradiance measurement and (2) the empirical line correction method by linking a set of field reflectance measured simultaneous with the image capture. Field reflectance were obtained using a spectroradiometer during the flight and used for building the linear equation for the empirical method and for the validation of image reflectance derived. Although both methods provided the high correlations between field reflectance and image-derived reflectance, their distributions were somewhat different. While the direct method provided rather stable and consistent distribution of reflectance all over the entire image area, the empirical method showed very unstable and inconsistent reflectance distribution. The direct method would be more appropriate for relatively wide area that requires more time to acquire image and may vary in downwelling irradiance and atmospheric conditions.

The effect of flower decoration on customer's satisfaction and re-visit of a baby's first birthday (화훼장식이 돌잔치 고객의 만족도와 재방문 의도에 미치는 영향)

  • Kim, Joung Hee;Lim, Young Hee;Kim, Kiu Weon
    • FLOWER RESEARCH JOURNAL
    • /
    • v.19 no.1
    • /
    • pp.68-76
    • /
    • 2011
  • This study was conducted to investigate customer taste related to satisfaction of a baby's first birthday party and re-visit of venues. General characteristics of customers were similar in male and female or the married and the unmarried. Mainstream age of respondents was from in their 20's to 30's. Among them, the number of university graduates were the largest in education level. Theoretical model was composed with seven significant variables of design style and composition and design harmony and color sense for flower decoration, accessibility, facility, service and price, satisfaction, and intention of re-visit based on the result of analysis on these factors. Exploratory factor analysis was performed using SPSS 14.0K. Structural equation modeling(SEM) for simultaneous measure of path coefficient in all casualty of study model, measurement model of AMOS 7.0 for evaluation of validity, and reliability and factor analysis method using technical statistics, frequency analysis, and Cronbach's Alpha for data analysis were used. The result of hypothesis verification showed that design style and composition was the most significant item in satisfaction of parameter and it was followed by design harmony and color sense. While service and price had positive effect on satisfaction, accessibility and facility had no relation to it. It means that the most crucial variable was a flower decoration in planning and representation of the celebration of baby's first birthday. In conclusion, the finding of this study suggests that the effective utilization of these variables will contribute to the enhancement of satisfaction affecting improvement service and price or intention of re-visit.

Discrepancies and Validation of Ethanol Level Determination with Osmolar Gap Formula in Patients with Suspected Acute Poisoning (급성 중독환자에서 삼투압 계산식으로 추정된 에탄올 농도의 유효성 검증)

  • Jung, Haewon;Lee, Mi Jin;Cho, Jae Wan;Ahn, Jae Yun;Kim, Changho
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.17 no.2
    • /
    • pp.47-57
    • /
    • 2019
  • Purpose: Osmolar gap (OG) has been used for decades to screen for toxic alcohol levels. However, its reliability may vary due to several reasons. We validated the estimated ethanol concentration formula for patients with suspected poisoning and who visited the emergency department. We examined discrepancies in the ethanol level and patient characteristics by applying this formula when it was used to screen for intoxication due to toxic levels of alcohol. Methods: We retrospectively reviewed 153 emergency department cases to determine the measured levels of toxic ethanol ingestion and we calculated alcohol ingestion using a formula based on serum osmolality. Those patients who were subjected to simultaneous measurements of osmolality, sodium, urea, glucose, and ethanol were included in this study. Patients with exposure to other toxic alcohols (methanol, ethylene glycol, or isopropanol) or poisons that affect osmolality were excluded. OG (the measured-calculated serum osmolality) was used to determine the calculated ethanol concentration. Results: Among the 153 included cases, 114 had normal OGs (OG≤14 mOsm/kg), and 39 cases had elevated OGs (OG>14). The mean difference between the measured and estimated (calculated ethanol using OG) ethanol concentration was -9.8 mg/dL. The 95% limits of agreement were -121.1 and 101.5 mg/dL, and the correlation coefficient R was 0.7037. For the four subgroups stratified by comorbidities and poisoning, the correlation coefficients R were 0.692, 0.588, 0.835, and 0.412, respectively, and the mean differences in measurement between the measured and calculated ethanol levels were -2.4 mg/dL, -48.8 mg/dL, 9.4 mg/dL, and -4.7 mg/dL, respectively. The equation plots had wide limits of agreement. Conclusion: We found that there were some discrepancies between OGs and the calculated ethanol concentrations. Addition of a correction factor for unmeasured osmoles to the equation of the calculated serum osmolality would help mitigate these discrepancies.

CFD Analysis on the Internal Reaction in the SNCR System (SNCR 시스템 내부의 물질 반응에 관한 전산해석적 연구)

  • Koo, Seongmo;Yoo, Kyung-Seun;Chang, Hyuksang
    • Clean Technology
    • /
    • v.25 no.1
    • /
    • pp.63-73
    • /
    • 2019
  • Numerical analysis was done to evaluate the chemical reaction and the reduction rate inside of selective non-catalytic reduction to denitrification in combustion process. The $NO_X$ reduction in selective non-catalytic reduction is converted to not only nitrogen but also nitrous oxide. Simultaneous $NO_X$ reduction and nitrous oxide generation suppressing is required in selective non-catalytic reduction because nitrous oxide influences the global warming as a greenhouse gas. The current study was performed compare the computational analysis in the same temperature and amount of NaOH, and in comparison with the previous research experiments and confirmed the reliability of the computational fluid dynamics. Additionally, controlling the addition amount of NaOH to predict the $NO_X$ reduction efficiency and nitrous oxide production. Numerical analysis was done to check the mass fraction of each material in the measurement point at the end of selective non-catalytic reduction. Experimental Value and simulation value by numerical analysis showed an error of up to 18.9% was confirmed that a generally well predicted. and it was confirmed that the widened temperature range of more than 70% $NO_X$ removal rate is increased when the addition amount of NaOH. So, large and frequent changes of the reaction temperature waste incineration facilities are expected to be effective.