• Title/Summary/Keyword: simultaneous measurement

Search Result 486, Processing Time 0.032 seconds

A Study on the Development of Soil Moisture Measuring Unit (인공토조용(人工土槽用) 토양함수율(土壤含水率) 측정기(測程器) 개발(開發)에 관(關)한 연구(硏究))

  • Park, J.G.;Lee, S.K.;Rhee, J.Y.
    • Journal of Biosystems Engineering
    • /
    • v.11 no.2
    • /
    • pp.14-22
    • /
    • 1986
  • This study was carried out to find a method which can be used to measure the soil moisture content of the soil bin exactly and quickly. And gypsum block is used as an instrument in measuring soil moisture content in the field of green house farming, etc.. However the characteristics of gypsum block, or the guide line of making gypsum block is not well introduced in Korea. So the information about gypsum block such as the density of gypsum, type of electrode, dimension of electrode, distance between electrodes, density of surrounding soil were included in this study and their effects on the relationship between soil moisture content and electrical resistance were investigated. The results of this study are as follows; 1. The grid type electrode was quicker in accessing the equilibrium condition and showed more sensitive response to the change of soil moisture content than the plate type electrode. 2. The longer the distance between the electrodes, the larger the electrical resistance, and the distance of 3 to 5 mm was recommended. 3. The larger the width of the electrode, the smaller the electrical resistance. However, there was no significance between the levels designed in this study. Considering the size of the gypsum block itself, the adaptible range of width may be 4 to 8 mm. 4. The higher the density of gypsum, the smaller the electrical resistance. And the block of lower density was broken down in the soil of higy moisture content. The optimum ratio of gypsum to water was 7:5. 5. The measuring system used in this study allowed simultaneous, multi-data acquisition. So this system using A/D converter can be applied to the measurement of soil moisture content of soil bin.

  • PDF

Comparison between the Charcoal Tube Sampling Method and the Diffusive Sampler, and the Applicability of Diffusive Sampler in the Field (확산형포집기(3M OVM #3500)와 활성탄관의 유기용제 포집농도 비교 및 확산형포집기의 현장 적용 가능성)

  • Jang, Sung Ho;Kim, Hyoung-Ah
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.15 no.3
    • /
    • pp.261-269
    • /
    • 2005
  • To investigate the field applicability of a diffusive sampler (3M OVM #3500, passive sampling method) authors conducted a simultaneous measurement of personal organic solvents exposure in the air of the workplaces by charcoal tube with low volume sampler (active sampling method) and diffusive sampler. Samples were collected and analyzed by NIOSH method ($NMAM^{(R)}$) from thirty-eight workers in 12 factories who work in 6 different processes. Geometric mean (GM) and geometric standard deviation (GSD) were used to describe the result. To compare the results of the two methods, paired t-test was used. According to the manual of the exposure assessment of the mixed organic solvents (Ministry of Labor, Korea), Em was calculated. Simple linear regression was used to evaluate the relationship between the two methods. Results were as follows; 1. Eight different solvents (ethyl acetate, n-hexane, toluene, xylene, acetone, isopropyl alcohol, methyl ethyl ketone (MEK), and methyl isobutyl ketone) were detected simultaneously in the two methods and the concentrations of the personal exposure were lower than 0.5 TLV level. The concentration of the charcoal tube method was higher than that of a diffusive sampler in n-hexane and MEK (p<0.05). 2. Em of the charcoal tube method was higher than that of diffusive sampler method but not significantly different and was lower than the OEL (Occupational Exposure Limit) in all 6 processes. 3. There was a significant correlation between the two methods in low concentrations of the 8 organic solvents (p<0.05). In conclusion, there was no difference in charcoal tube method and diffusive sampler method in low concentrations of some organic solvents, diffusive sampler can be applied to assess the personal monitoring in low level exposure.

Utility of Toe-brachial Index for Diagnosis of Peripheral Artery Disease

  • Park, Seong-Chul;Choi, Chang-Yong;Ha, Young-In;Yang, Hyung-Eun
    • Archives of Plastic Surgery
    • /
    • v.39 no.3
    • /
    • pp.227-231
    • /
    • 2012
  • Background : The ankle brachial pressure index (ABI) is a simple, useful method for diagnosing peripheral artery disease (PAD). Although the ABI is an objective diagnostic method, it has limited reliability in certain scenarios. The aim of the present study was to determine the accuracy and reliability of the toe brachial index (TBI) as a diagnostic tool for detecting stenosis in PAD, associated with normal or low ABI values. Methods : ABI and TBI values were measured in 15 patients with diabetic gangrene who were suspected of having lower extremity arterial insufficiency. The ABI and TBI values were measured using a device that allowed the simultaneous measurement of systolic blood pressure in the upper and lower extremities. In addition, the ABI and TBI values were compared pre- and post-angiography. Results : Patients with an ABI of 0.9-1.3 showed almost no difference between the 2 measurements. The patients with TBI >0.6 had no arterial insufficiency. The patients with TBI <0.6 required vascular intervention with ballooning. After the angiography, the gangrenous wounds decreased in size more rapidly than they did prior to the intervention. Conclusions : Our findings suggest that TBI is the method of choice for evaluating lower limb perfusion disorders. This result requires further studies of TBI in a larger number of patients. Future long-term studies should therefore evaluate the utility of TBI as a means of screening for PAD and the present findings should be regarded as preliminary outcomes.

A Study of Optical Characteristics for Biodiesel and Diesel Smoke Particles and Measuring their Dimensionless Light Extinction Constants (바이오디젤과 디젤 연기입자의 광학특성 및 무차원 광소멸계수 측정에 관한 연구)

  • Choi, Seuk-Cheun;Jang, Yeong-Seok;Park, Seul-Hyun;Kim, Youn-Kyu
    • Fire Science and Engineering
    • /
    • v.30 no.1
    • /
    • pp.37-42
    • /
    • 2016
  • The dimensionless extinction constants of smoke particles produced from burning of soy methyl ester (B100) biodiesel and ultra low sulfur diesel (ULSD) fuels were measured. To this end, optical measurements of smoke volume fraction with the aid of a He-Ne laser at 633 nm were compared to the simultaneous gravimetric measurements. The average value of measured dimensionless extinction constants at 633 nm was 11.8 for biodiesel smoke particles and 11.1 for diesel smoke particles, respectively whose values are very comparable withing the range of measurement uncertainty (${\pm}10.1%$). The analysis of Raman spectroscopy revealed that overall characteristics of light extinction between particles produced from each fuel may differ from each other.

Passivation Effects of Excimer-Laser-Induced Fluorine using $SiO_{x}F_{y}$ Pad Layer on Electrical Characteristics and Stability of Poly-Si TFTs ($SiO_{x}F_{y}$/a-Si 구조에 엑시머 레이저 조사에 의해 불소화된 다결정 실리콘 박막 트랜지스터의 전기적 특성과 신뢰도 향상)

  • Kim, Cheon-Hong;Jeon, Jae-Hong;Yu, Jun-Seok;Han, Min-Gu
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.9
    • /
    • pp.623-627
    • /
    • 1999
  • We report a new in-situ fluorine passivation method without in implantation by employing excimer laser annealing of $SiO_{x}F_{y}$/a-Si structure and its effects on p-channel poly-Si TFTs. The proposed method doesn't require any additional annealing step and is a low temperature process because fluorine passivation is simultaneous with excimer-laser-induced crystallization. A in-situ fluorine passivation by the proposed method was verified form XPS analysis and conductivity measurement. From experimental results, it has been shown that the proposed method is effective to improve the electrical characteristics, specially field-effect mobility, and the electrical stability of p-channel poly-Si TFTs. The improvement id due to fluorine passivation, which reduces the trap state density and forms the strong Si-F bonds in poly-Si channel and $SiO_2/poly-Si$ interface. From these results, the high performance poly-Si TFTs canbe obtained by employing the excimer-laser-induced fluorine passivation method.

  • PDF

Multi-dimensional wind vibration coefficients under suction for ultra-large cooling towers considering ventilation rates of louvers

  • Ke, S.T.;Du, L.Y.;Ge, Y.J.;Tamura, Y.
    • Structural Engineering and Mechanics
    • /
    • v.66 no.2
    • /
    • pp.273-283
    • /
    • 2018
  • Currently, the dynamic amplification effect of suction is described using the wind vibration coefficient (WVC) of external loads. In other words, it is proposed that the fluctuating characteristics of suction are equivalent to external loads. This is, however, not generally valid. Meanwhile, the effects of the ventilation rate of louver on suction and its WV are considered. To systematically analyze the effects of the ventilation rate of louver on the multi-dimensional WVC of ultra-large cooling towers under suctions, the 210 m ultra-large cooling tower under construction was studied. First, simultaneous rigid pressure measurement wind tunnel tests were executed to obtain the time history of fluctuating wind loads on the external surface and the internal surface of the cooling tower at different ventilation rates (0%, 15%, 30%, and 100%). Based on that, the average values and distributions of fluctuating wind pressures on external and internal surfaces were obtained and compared with each other; a tower/pillar/circular foundation integrated simulation model was developed using the finite element method and complete transient time domain dynamics of external loads and four different suctions of this cooling tower were calculated. Moreover, 1D, 2D, and 3D distributions of WVCs under external loads and suctions at different ventilation rates were obtained and compared with each other. The WVCs of the cooling tower corresponding to four typical response targets (i.e., radial displacement, meridional force, Von Mises stress, and circumferential bending moment) were discussed. Value determination and 2D evaluation of the WVCs of external loads and suctions of this large cooling tower at different ventilation rates were proposed. This study provides references to precise prediction and value determination of WVC of ultra-large cooling towers.

Temperature Dependent Terahertz Generation at Periodically Poled Stoichiometric Lithium Tantalate Crystal Using Femtosecond Laser Pulses

  • Yu, N.E.;Kang, C.;Yoo, H.K.;Jung, C.;Lee, Y.L.;Kee, C.S.;Ko, D.K.;Lee, J.
    • Journal of the Optical Society of Korea
    • /
    • v.12 no.3
    • /
    • pp.200-204
    • /
    • 2008
  • Coherent tunable terahertz generation was demonstrated in periodically poled stoichiometric lithium tantalate crystal via difference frequency generation of femtosecond laser pulses. Simultaneous forward and backward terahertz radiations were obtained around 1.35 and 0.63 THz, respectively at low temperature. By cooling the crystal to reduce losses caused by phonon absorptions, the generated THz bandwidth was as narrow as 23GHz at the center frequency of 0.63 THz. The measurement result of temperature-dependent showed gradual intensity increase of the generated terahertz pulse and red shift of the center frequency as the temperature decrease from 291 to 143 K, but insignificant reduction of the spectral bandwidth. Furthermore, the stoichiometric crystal was very suitable for the suppression of THz loss at low temperature compared to the congruent $LiNbO_3$ crystal.

The Degradation Analysis of Characteristic Parameters by NBTI stress in p-MOS Transistor for High Speed (고속용 p-MOS 트랜지스터에서 NBTI 스트레스에 의한 특성 인자의 열화 분석)

  • Lee, Yong-Jae;Lee, Jong-Hyung;Han, Dae-Hyun
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.1A
    • /
    • pp.80-86
    • /
    • 2010
  • This work has been measured and analyzed the device degradation of NBTI (Negative Bias Temperature Instability) stress induced the increase of gate-induced-drain-leakage(GIDL) current for p-MOS transistors of gate channel length 0.13 [${\mu}m$]. From the relation between the variation of threshold voltage and subthreshold slop by NBTI stress, it has been found that the dominant mechanism for device degradation is the interface state generation. From the GIDL measurement results, we confined that the EHP generation in interface state due to NBTI stress led to the increase of GIDL current. As a results, one should take care of the increased GIDL current after NBTI stress in the ultra-thin gate oxide device. Also, the simultaneous consideration of reliability characteristics and dc device performance is highly necessary in the stress parameters of nanoscale CMOS communication circuit design.

Water Layer in Course of Corrosion of Copper in Humid Air Containing $SO_2$

  • Sasaki, Takeshi;Itoh, Jun;Ohtsuka, Toshiaki
    • Corrosion Science and Technology
    • /
    • v.2 no.2
    • /
    • pp.88-92
    • /
    • 2003
  • The technique for in situ simultaneous measurements of IR-RAS and QCM, which has been developed for investigation of corrosion in gaseous environments, was employed to study the effects of an extremely thin water layer on the corrosion rate. An evaporated copper film on a QCM element was exposed to air containing water vapor and $SO_2$, and time-resolved IR-RAS spectra were measured and mass gains were simultaneously followed with QCM. The tested ranges of relative humidity (RH) and concentration of $SO_2$ were 60% - 90% and 1 - 20 ppm, respectively. On the basis of 2D-IR analysis, the corrosion products were determined to be Chevreul's salt ($CuSO_3Cu_2SO_3{\cdot}2H_2O$) and $CuSO_4{\cdot}5H_2O$. By constructing curves of the relations between band intensities of IR spectra and mass gains of QCM for the corrosion products, the time variations in each product were determined from spectral experiments on copper plates. The thicknesses of physically adsorbed water layers in course of the corrosion process were also determined from water band intensities. The results showed that the thickness of the physically adsorbed water layer increased with increase in RH, and it also increased with increase in accumulation of corrosion products. The latter is probably due to the capillary effect of the corrosion products.

Large deflection behavior and stability of slender bars under self weight

  • Goncalves, Paulo B.;Jurjo, Daniel Leonardo B.R.;Magluta, Carlos;Roitman, Ney;Pamplona, Djenane
    • Structural Engineering and Mechanics
    • /
    • v.24 no.6
    • /
    • pp.709-725
    • /
    • 2006
  • In this paper the buckling and post-buckling behavior of slender bars under self-weight are studied. In order to study the post-buckling behavior of the bar, a geometrically exact formulation for the non-linear analysis of uni-directional structural elements is presented, considering arbitrary load distribution and boundary conditions. From this formulation one obtains a set of first-order coupled nonlinear equations which, together with the boundary conditions at the bar ends, form a two-point boundary value problem. This problem is solved by the simultaneous use of the Runge-Kutta integration scheme and the Newton-Raphson method. By virtue of a continuation algorithm, accurate solutions can be obtained for a variety of stability problems exhibiting either limit point or bifurcational-type buckling. Using this formulation, a detailed parametric analysis is conducted in order to study the buckling and post-buckling behavior of slender bars under self-weight, including the influence of boundary conditions on the stability and large deflection behavior of the bar. In order to evaluate the quality and accuracy of the results, an experimental analysis was conducted considering a clamped-free thin-walled metal bar. As this kind of structure presents a high index of slenderness, its answers could be affected by the introduction of conventional sensors. In this paper, an experimental methodology was developed, allowing the measurement of static or dynamic displacements without making contact with the structure, using digital image processing techniques. The proposed experimental procedure can be used to a wide class of problems involving large deflections and deformations. The experimental buckling and post-buckling behavior compared favorably with the theoretical and numerical results.