• Title/Summary/Keyword: simultaneous measurement

Search Result 489, Processing Time 0.027 seconds

Measurement of Complex Permittivity and Permeability for Powder-type Materials (분말재료의 복소 유전율 및 투자율 측정)

  • Park, Sang-Bok;Lee, Jang-Soo;Chong, Young-Seek;Cheon, Chang-Yul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.12
    • /
    • pp.2196-2201
    • /
    • 2007
  • Materials used at microwave are usually used as a dielectric with a manufacturing purpose of printed circuit boards, etc. Complex permittivity of them can be measured from attenuation constant or propagation constant of a transmission line using a microstrip line with bulk type. But as the technique recently which can manufacture to have complex permittivity and permeability demanded using nonferrous metals for powder-type grows up, we need sensors and methods which can measure characteristics of powder-type materials. So far measuring methods of permittivity and permeability with waveguide or coaxial cable are used but they have faults which have a complex measurement method and are difficult to simultaneously measure permittivity and permeability. In this paper, a simultaneous measuring method of permittivity and permeability with 2-port coaxial cable and a new proposed calculation. The proposed 2-port coaxial cable is designed to be easy to insert materials and to have a wideband. We measure permittivity and permeability of magnetic powder(Ni-Fe-Mo, Ni-Fe) which reveal its characteristic at $0.3{\sim}1.3GHz$ to identify the proposed sensor.

Exposure to Fine Particle along Different Commuting Routes in Urban Area of Fukuoka, Japan

  • Ma, Chang-Jin
    • Asian Journal of Atmospheric Environment
    • /
    • v.9 no.3
    • /
    • pp.205-213
    • /
    • 2015
  • The objective of the current study was to assess the comparative risk associated with exposure to particulate matter (PM) while commuting via different public transport modes in Fukuoka, Japan. For the given routes and measuring days, a trip-maker carried a lightweight portable bag loaded the real-time measurement devices which take simultaneous measurement for size-fractioned particle number concentration, $PM_{2.5}$ mass concentration, and total suspended particle (TSP) collection. The results of the present study have shown significant differences between public transports as commuting modes in Fukuoka. The PM exposure levels on subway platform and inside subway train were overwhelmingly higher than those of other points on commuting route. The relative ratio between modes (i.e., the ratio of $PM_{2.5}$ inside subway to that inside bus) provides an idea for choosing a right commuting mode for our health. This study clearly provided evidence of the extremely high levels of iron exposure by subway uses compared to bus uses. The result of theoretically reconstructed mass concentration of $PM_{2.0-0.3}$ collected on subway platform suggests that the PM of underground subway will be associated with PM both generated in subway system and inleakaged from outdoor environment.

A Simple Enzymatic Method for Quantitation of 2'-Fucosyllactose

  • Seydametova, Emine;Shin, Jonghyeok;Yu, Jiwon;Kweon, Dae-Hyuk
    • Journal of Microbiology and Biotechnology
    • /
    • v.28 no.7
    • /
    • pp.1141-1146
    • /
    • 2018
  • 2'-Fucosyllactose (2'-FL) is one of the most important human milk oligosaccharides and has several health benefits for infants. The levels of 2'-FL in breast milk or samples from other sources can be quantified by high-performance liquid chromatography. However, this method cannot be used for simultaneous detection of the target compound in numerous samples. Here, we developed a simple method for quantifying 2'-FL in a microplate format. The method involves two steps: (i) release of $\text\tiny{L}$-fucose from 2'-FL by ${\alpha}$-(1-2,3,4,6)-$\text\tiny{L}$-fucosidase and (ii) measurement of NADPH formed during the oxidation of $\text\tiny{L}$-fucose by $\text\tiny{L}$-fucose dehydrogenase. This method enables measurement of up to 5 g/l 2'-FL in 50 min using a 96-well microplate. The efficiency and simplicity of the proposed method make it suitable for the analyses of a large number of samples simultaneously.

Study on the Simultaneous Control of the Seam tracking and Leg Length in a Horizontal Fillet Welding Part 1: Analysis and Measurement of the Weld Bend Geometry

  • Moon, H.S.;Na, S.J.
    • International Journal of Korean Welding Society
    • /
    • v.1 no.1
    • /
    • pp.23-30
    • /
    • 2001
  • Among the various welding conditions, the welding current that is inversely proportional to the tip-to-work-piece distance is an essential parameter as to monitor the GMAW process and to implement the welding automation. Considering the weld pool surface geometry including weld defects, it should modify the signal processing method for automatic seam tracking in horizontal fillet welding. To meet the above necessities, a mathematical model related with the weld pool geometry was proposed as in a conjunction with the two-dimensional heat flow analysis of the horizontal fillet welding. The signal processing method based on the artificial neural network (Adaptive Resonance Theory) was proposed for discriminating the sound weld pool surface from that with the weld defects. The reliability of the numerical model and the signal processing method proposed were evaluated through the experiments of which showed that they are effective for predicting the weld bead shape with or without the weld defects in a horizontal fillet welding.

  • PDF

A Study on the Fluid Flow with Ultrasonic Forcing by PIV Measurement - On the Incident Angle and Reflector - (초음파가 가진된 유체유동의 PIV계측에 의한 연구 - 입사각과 반사재료를 중심으로 -)

  • Ju, E.S.;Lee, Y.H.;La, W.J.;Park, Y.H.
    • Journal of Power System Engineering
    • /
    • v.4 no.4
    • /
    • pp.32-40
    • /
    • 2000
  • A study on the fluid flow with ultrasonic forcing was carried out to get the enhancement of turbulence by laying emphasis on the ultrasonic incidence angles and reflectors. A large water tank was made of the transparent acrylic plates and city water of $25^{\circ}C$ was used as working fluid. 7 angles ($30^{\circ},\;45^{\circ},\;60^{\circ},\;90^{\circ},\;120^{\circ},\;135^{\circ},\;150^{\circ}$) as the ultrasonic incidence angle and 4 materials (wood, acryl, glass, iron) as the reflector were selected arid experiments for the above were made. The velocity vector distribution, kinetic energy and turbulence intensity of the turbulence flow fields enhanced by ultrasonic forcing were measured, compared and discussed by using the PIV measurement which was possible to measure the velocities of simultaneous multipoints. In results, it was cleared that the incidence angle of ultrasonic and material of reflector influenced the enhancement of turbulence.

  • PDF

A Method to Estimate Peripheral Systolic Blood Pressure using Pulse Transit Time during Bicycle Ergometer Exercise of Healthy Korean Subjects in their Twenties

  • Lee Jeong-Chan;Eo Yun-Hye;Park Kyung-Mo;Park Seung-Hun
    • Journal of Biomedical Engineering Research
    • /
    • v.27 no.3
    • /
    • pp.89-93
    • /
    • 2006
  • A simple algorithm that can be used to estimate a healthy person's blood pressure using pulse transit time is proposed in this paper. Fifty healthy students participated in the experiment that was conducted in line with the study. The subjects were asked to exercise on several exercise levels using a bicycle ergometer. Their blood pressures during the succeeding rest period were measured. A simple method was proposed to illustrate the relationship between blood pressure and pulse transit time. The systolic blood pressures as well as the heights and weights of the subjects were regarded as the proper parameters, and a second-order regression curve was produced to estimate the subjects' blood pressures. The mean error of estimation was less than 10 mmHg, which was the mean error of manual measurement. Although our estimation model is so simple, it can be used to estimate continuous blood pressure measurement for bicycle ergometer exercise. The electrocardiograms, photoplethysmograms, and blood pressures, however, could not be measured simultaneously As such, their estimation may be slightly different from the results taken from simultaneous measurements.

Analysis of Facial Coloration in Accordance with the Type of Personal Color System of Female University Students (여대생의 퍼스널 컬러 시스템 유형에 따른 얼굴색 분석)

  • Lee, Eun-Young;Park, Kil-Soon
    • The Research Journal of the Costume Culture
    • /
    • v.20 no.2
    • /
    • pp.144-153
    • /
    • 2012
  • This study performed a simultaneous sensory evaluation and color measurement, targeting 136 female university students who live in the Dae-Jeon region. the study measured participants'facial coloration under the condition of available light between 11 AM and 3 PM from Spring (May) to Autumn (October) in 2009. For statistical analysis, descriptive statistics, a member variate analysis, and discriminant analysis were executed using SPSS version 18.0 of the statistics program. The results of this study are as follows. First, as a result of the sensory evaluation, the blue undertone well matched to face type was dominantly distributed among the female university student participants. Second, the forehead showed a type of yellowish coloration and was relatively dark to cheeks. However the cheek displayed a reddish coloration and was relatively bright compared to the forehead from an evaluation of a cheek and forehead color measurement. Third, due to the investigation the of facial coloration variable, a yellowish and reddish chromaticity on the cheek were evident as a variable of facial coloration, which has an influence on the classification of the types of facial color. As a result of the induced discriminant through these two color variables, the yellowish chromaticity appeared as a color variable to have a greater influence than the reddish chromaticity on the cheek.

Quantitative gated myocardial perfusion SPECT (정량적 게이트 심근관류 SPECT)

  • Ahn, Byeong-Cheol
    • The Korean Journal of Nuclear Medicine
    • /
    • v.37 no.4
    • /
    • pp.207-218
    • /
    • 2003
  • Myocardial perfusion imaging has been increasingly used to provide prognostic data and guidance on the choice of appropriate management of patients with known or suspected coronary artery disease. The electrocardiogram gated myocardial SPECT program is corning into wide use with an advent of $^{99m}Tc-labeled$ tracers and an improvement of SPECT machines. The gated technique permits measurement of important cardiac prognostic indicators without any further discomforts or radiation burden in patients underwent standard myocardial perfusion SPECT. In addition, gated study significantly improves diagnostic yield by reducing the number of borderline interpretations and could find myocardial stunning and viable myocardium. Gated single photon emission computed tomography (SPECT) imaging allows the automated calculation of end-diastolic volume, end-systolic volume, ejection fraction, myocardial mass and the assessment of regional wall motion and thickening, and it have dramatically improved assessment of coronary artery disease in routine nuclear practice. This allows the simultaneous assessment of both perfusion and function within the same acquisition, and serves as a cost-effective technique for providing more diagnostic data with fewer diagnostic tests. Because the diagnostic and prognostic power derived from knowledge of left ventricular function can be added to that provided by assessing myocardial perfusion, gated SPECT imaging has rapidly gained widespread acceptance and is now used on a routine clinical basis in a growing number of laboratories, including South Korea. The gated SPECT technique for measurement of left ventricular parameters has been validated against a variety of well established techniques. In this work, overview of gated myocardial perfusion SPECT focus on functional parameters is presented.

Comparison of Gastrointestinal Permeability of Caffeine, Propranolol, Atenolol, Ofloxacin, and Quinidine Measured Using Ussing Chamber System and Caco-2 Cell Monolayer

  • Song, Im-Sook;Choi, Young A;Choi, Min-Koo
    • Mass Spectrometry Letters
    • /
    • v.8 no.2
    • /
    • pp.34-38
    • /
    • 2017
  • The purpose of this study was to develop a cocktail approach for the measurement of the permeability of marker compounds, caffeine and propranolol (high permeability), ofloxacin (intermediate), atenolol (low), and quinidine (P-glycoprotein substrate), simultaneously. Then we compared the permeability in Caco-2 cells with that in rat intestinal segments. The difference between individual measurement and cocktail approach was less than 20 %, and the permeabilities of these compounds were similar to those previously reported, suggesting that the cocktail transport study and simultaneous drug analysis were successfully developed and validated in this study. Additionally, in the application of this cocktail method, the permeability of five drugs in rat jejunum was similar to that in ileum but different from that in colon, which was measured using the Ussing chamber system. Moreover, permeability in jejunum and ileum was similar to that in Caco-2 cells. In conclusion, the permeability in Caco-2 cells was equivalent to the permeability in rat jejunum and ileum determined with the Ussing system. Therefore, this newly developed cocktail assay and its application to the Ussing system can be a useful tool for robust and rapid screening for site-specific permeability in rat intestine, thus accelerating the prediction of absorption of new chemical entities.

TWO KINDS OF STATIC AND DYNAMIC STATE ESTIMATION METHODS BY USING WIND SPEED INFORMATION IN ENVIRONMENTAL LOW-FREQUENCY NOISE MEASUREMENT

  • Takakuwa, Y.;Ohta, M.;Nishimura, M.;Minamihara, H.
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1994.06a
    • /
    • pp.806-811
    • /
    • 1994
  • Two kinds of static and dynamic state estimation methods are newly discussed for the problem of the measurement disturbance of environmental low-frequency noise in the presence of wind-induced noise. First, the probability characteristics of wind-induced noise are discussed in the form of probability distribution conditioned by wind speed, based on the simultaneous observation of the wind-induced noise and wind speed near a microphone. Next, especially form the viewpoint of simplicity for practical use, two kinds of static and dynamic state estimation methods are discussed. The static estimation method using the information on wind speed is fundamentally supported by the conservation principle of energy sum. The dynamic one is the method by using a recursive digital filter with the parameters successively renewed by the information on wind speed. This can be also simplified by using well-know Kalman filter under the assumption of the Gaussian distribution. The effectiveness of proposed two estimation methods are shown through experiments under a breezy condition in the open filed.

  • PDF