• 제목/요약/키워드: simultaneous measurement

검색결과 489건 처리시간 0.028초

PIV를 이용한 터빈펌프의 동${\cdot}$정익 속도장 계측 (Measurement of the Velocity Field of Rotor-Stator in a Centrifugal Turbine Pump Using PIV)

  • 임유청;서민식;이영호
    • 한국유체기계학회 논문집
    • /
    • 제2권1호
    • /
    • pp.35-42
    • /
    • 1999
  • The present experimental study is focused on the application of multi-point simultaneous measurement by PIV(Particle Image Velocimetry) to rotor-stater region within centrifugal turbine pump. Six different kinds of rpm(120, 500, 1000, 1500, 2000 and 2500) are selected as experimental condition. Optimized cross correlation identification to obtain velocity vectors is implemented with direct calculation of correlation coefficients. Fine optical setup concerned with PIV performance is arranged for the accurate PIV measurement of high-speed complex flow. The instantaneous and time-mean velocity distribution and velocity profile are represented quantitatively at the rotor and stator region.

  • PDF

온도감응형 인광물질을 이용한 온도장 및 열변형 동시 계측 기법 개발 (Development of a multi-sensing technique for temperature and strain field of high-temperature using thermographic phosphors)

  • 임유진;염은섭
    • 한국가시화정보학회지
    • /
    • 제19권3호
    • /
    • pp.77-83
    • /
    • 2021
  • Solid oxide fuel cell (SOFC) operates at high temperatures in range of 600-800℃. Since layers of SOFC are composed of different substances, different thermal expansion in SOFC can result in defects under high temperature conditions. For understanding relation between temperature field and the thermal deformation in SOFC, temperature and strain field were simultaneously estimated using thermographic phosphors by optical measurement. Temperature fields were obtained by the life-time method, and the temperature differences of one specimen was checked with thermocouple. The thermal deformation was estimated by digital image correlation (DIC) method with extracted phosphorescence images. To investigate the deformation accuracy of DIC measurement, thermographic phosphors were coated with and without grid pattern on aluminum surface. Simultaneous measurement of temperature fields and thermal deformation were carried out for YSZ. This study will be helpful to multi-sensing of temperature field and thermal deformation on SOFC cells.

단일 영상과 거리센서를 이용한 SLAM시스템 구현 (Implementation of the SLAM System Using a Single Vision and Distance Sensors)

  • 유성구;정길도
    • 전자공학회논문지SC
    • /
    • 제45권6호
    • /
    • pp.149-156
    • /
    • 2008
  • SLAM(Simultaneous Localization and Mapping)은 무인 로봇 자동 항법시스템의 중요 기술로 센서 데이터로부터 로봇의 위치를 결정하고 기하학적 맵을 구성하는 것이다. 기존 방법으로는 초음파, 레이저 등의 거리 측정 센서를 이용해 로봇의 전역 위치를 찾는 방법과 스테레오 비전을 통한 방법이 개발되었다. 거리 측정 센서만으로 구성한 SLAM 시스템은 계산량이 간소하고 비용이 적게 들지만 센서의 오차나 비선형에 의해 정밀도가 조금 떨어진다. 이에 반해 스테레오 비전 시스템은 3차원 공간영역을 정확히 측정할 수 있지만 계산량이 많아 고사양의 시스템을 요구하고 스테레오 시스템 또한 고가이다. 따라서 본 논문에서는 단일 카메라 영상과 PSD(position sensitive device) 센서를 사용하여 SLAM을 구현하였다. 전방향의 PSD 센서로부터 일정 거리의 장애물을 감지하고 전면 카메라의 영상처리를 통해 장애물의 크기 및 특징을 감지한다. 위의 데이터를 통해 확률분포 SLAM을 구성하였고 실제 구현을 통해 성능검증을 하였다.

IEEE 1459-2010 규격의 정의를 이용한 다중 입력 채널을 갖는 전력 감시 시스템 (Power Monitoring System with Multiple Input Channels Using the Definition of IEEE Standard 1459-2010)

  • 전정채;오훈
    • 한국산학기술학회논문지
    • /
    • 제15권5호
    • /
    • pp.3100-3106
    • /
    • 2014
  • 본 논문에서는 전력 시스템의 전원 및 부하 측을 동시에 감시가 가능한 다 채널(전압 8채널, 전류 10채널) 전력 측정 시스템을 개발하였다. 제안된 시스템은 전력품질과 관련된 규정인 IEEE 1459-2010의 정의를 사용하여 전력 성분을 계산하는 신호처리 알고리즘을 기반으로 TMS320C42 DSP를 이용하여 개발하였다. 개발된 시스템은 표준 전원 공급 장치를 이용하여 그 성능 시험을 실시하였고, 그 결과 측정오차는 0.2% 이하로 나타났다. 또한 제안된 시스템을 3상 4선식 전력시스템에 설치하여 실증 시험을 실시하여 그 성능을 입증하였다. 제안된 시스템은 상업 및 산업용 전력 시스템에 적용하여 동시에 다 채널로 전력을 측정 및 분석함으로써 전력품질과 관련된 다양한 문제를 줄일 수 있을 것이다.

PVDF 압전소자를 이용한 심장박동 및 호흡수 동시측정센서개발 (Development of New Stacked Element Piezoelectric Polyvinylidene Fluoride Pressure Sensor for Simultaneous Heartbeat and Respiration Measurements)

  • 박창용;권현규;이소진;롱원만
    • 한국기계가공학회지
    • /
    • 제18권4호
    • /
    • pp.100-108
    • /
    • 2019
  • In this paper, a new stacked element pressure sensor has proposed for heartbeat and respiration measurement. This device can be directly attached to an individual's chest; heartbeat and respiration are detected by the pulsatile vibration and deformation of the chest. A key feature of the device is the simultaneous measurement of heart rate and respiration. The structure of the sensor consists of two stacked elements, in which one element includes one polyvinylidene fluoride (PVDF) thin film bonded on polydimethylsiloxane (PDMS) substrate. In addition, for the measurement and signal processing, the electric circuit and the filter are simply constructed with an OP-amp, resistance, and a capacitor. One element (element1, PDMS) maximizes the respiration signal; the other (element2, PVDF) is used to measure heartbeat. Element1 and element2 had sensitivity of 0.163V/N and 0.209V/N, respectively, and element2 showed improved characteristics compared with element1 in response to force. Thus, element1 and element2 were optimized for measuring respiration heart rate, respectively. Through mechanical and vivo human tests, this sensor shows the great potential to optimize the signals of heartbeat and respiration compared with commercial devices. Moreover, the proposed sensor is flexible, light weight, and low cost. All of these characteristics illustrate an effective piezoelectric pressure sensor for heartbeat and respiration measurements.

Simultaneous and Multi-frequency Driving System of Ultrasonic Sensor Array for Object Recognition

  • Park, S.C.;Choi, B.J.;Lee, Y.J.;Lee, S.R.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2004년도 ICCAS
    • /
    • pp.582-587
    • /
    • 2004
  • Ultrasonic sensors are widely used in mobile robot applications to recognize external environments, because they are cheap, easy to use, and robust under varying lighting conditions. However, the recognition of objects using a ultrasonic sensor is not so easy due to its characteristics such as narrow beam width and no reflected signal from a inclined object. As one of the alternatives to resolve these problems, use of multiple sensors has been studied. A sequential driving system needs a long measurement time and does not take advantage of multiple sensors. Simultaneous and pulse coding driving system of ultrasonic sensor array cannot measure short distance as the length of the code becomes long. This problem can be resolved by multi-frequency driving of ultrasonic sensors, which allows multi-sensors to be fired simultaneously and adjacent objects to be distinguished. Accordingly, this paper presents a simultaneous and multi-frequency driving system for an ultrasonic sensor array for object recognition. The proposed system is designed and implemented using a DSP and FPGA. A micro-controller board is made using a DSP, Polaroid 6500 ranging modules are modified for firing the multi-frequency signals, and a 5-channel frequency modulated signal generating board is made using a FPGA. To verify the proposed method, experiments were conducted in an environment with overlapping signals, and the flight distances for each sensor were obtained from filtering of the received overlapping signals and calculation of the time-of-flights.

  • PDF

Simultaneous determination of 30 ginsenosides in Panax ginseng preparations using ultra performance liquid chromatography

  • Park, Hee-Won;In, Gyo;Han, Sung-Tai;Lee, Myoung-Woo;Kim, So-Young;Kim, Kyung-Tack;Cho, Byung-Goo;Han, Gyeong-Ho;Chang, Il-Moo
    • Journal of Ginseng Research
    • /
    • 제37권4호
    • /
    • pp.457-467
    • /
    • 2013
  • A quick and simple method for simultaneous determination of the 30 ginsenosides (ginsenoside Ro, Rb1, Rb2, Rc, Rd, Re, Rf, Rg1, 20(S)-Rg2, 20(R)-Rg2, 20(S)-Rg3, 20(R)-Rg3, 20(S)-Rh1, 20(S)-Rh2, 20(R)-Rh2, F1, F2, F4, Ra1, Rg6, Rh4, Rk3, Rg5, Rk1, Rb3, Rk2, Rh3, compound Y, compound K, and notoginsenoside R1) in Panax ginseng preparations was developed and validated by an ultra performance liquid chromatography photo diode array detector. The separation of the 30 ginsenosides was efficiently undertaken on the Acquity BEH C-18 column with gradient elution with phosphoric acids. Especially the chromatogram of the ginsenoside Ro was dramatically enhanced by adding phosphoric acid. Under optimized conditions, the detection limits were 0.4 to 1.7 mg/L and the calibration curves of the peak areas for the 30 ginsenosides were linear over three orders of magnitude with a correlation coefficients greater than 0.999. The accuracy of the method was tested by a recovery measurement of the spiked samples which yielded good results of 89% to 118%. From these overall results, the proposed method may be helpful in the development and quality of P. ginseng preparations because of its wide range of applications due to the simultaneous analysis of many kinds of ginsenosides.

Simultaneous Equation Estimation in Finance and Corporate Financial Decision: Empirical Evidence from Pakistan Stock Exchange

  • AHMED, Wahab;KHAN, Hadi Hassan;RAUF, Abdul;ULHAQ, SM Nabeel;BANO, Safia;SARWAR, Bilal;HUDA, Shams ul;KHAN, Mirwaise;WALI, Ahmed;DURRANI, Maryam Najeeb
    • The Journal of Asian Finance, Economics and Business
    • /
    • 제8권3호
    • /
    • pp.11-21
    • /
    • 2021
  • In the last few years, there is growing interest in the field of simultaneous equation estimation in finance due to the endogeneity problem caused by measurement errors, simultaneity, or omitted variables. This study aims to discuss the endogeneity problem in corporate financing decisions and investigate the interrelationship of financial decision-making such as investment decision, dividend decision, and external financing decision in Pakistan Stock Exchange (PSX) using two-stage least squares (2SLS) and generalized method of moment (GMM) estimation. The Bruech-Pagan test shows that the data has no heteroskedasticity issue and 2SLS is a better approach in the context of this study as compared to the GMM approach, and internal instruments are also sufficiently strong and valid. The three financial decision-making attributes are not jointly determined, and the dividend is influenced by one-sided investment. In the emerging stock market context, external financing and investment are not inter-related and did not affect each other. The question of whether the simultaneous equation estimation can be useful in the context of the emerging stock markets and newly-growing firms remains unanswered. The inclusive evidence shows that the theoretical link in the emerging stock market is difficult to prove like in developed stock markets.

레이저시트광을 이용한 가시화 디젤엔진에서의 Soot 계측(제2보 : Soot 입경분포 및 수밀도 계측) (Soot Measurement in an Optically Accessible Diesel Engine Using Laser Sheet (2nd reprot: The Measurement for diameter and number density of Soot))

  • 이명준;박태기;하종률;정성식
    • 한국자동차공학회논문집
    • /
    • 제8권3호
    • /
    • pp.37-45
    • /
    • 2000
  • The technique of laser sheet beam has been applied to optically accessible diesel engine for the quantitative measurement of soot. The results provide the information for us for reduction of soot in diesel engine. We used both LIS nad LII techniques simultaneously in this study. LIS and LII images show the quantitative distribution of the soot concentration in an optically accessible diesel engine. In this study, several results were obtained by the simultaneous measurement of LIS and LII technique. The diameter and number density of soot in combustion chamber of the test engine were obtained from ATDC 20$^{\circ}$ to 110$^{\circ}$ . The increase rate of soot diameter was about 40$^{\circ}$ between ATDC 20$^{\circ}$and 110$^{\circ}$. And the number density of soot decreased significantly between ATDC 20$^{\circ}$and 40$^{\circ}$.

  • PDF

분포형 광음향센싱 기반 부분방전 모니터링 기술 연구 (Partial Discharge Monitoring Technology based on Distributed Acoustic Sensing)

  • 김희운;이주영;정효영;김영호;김명진
    • 센서학회지
    • /
    • 제31권6호
    • /
    • pp.441-447
    • /
    • 2022
  • This study describes a novel method for detecting and measuring partial discharge (PD) on an electrical facility such as an insulated power cable or switchgear using fiber optic sensing technology, and a distributed acoustic sensing (DAS) system. This method has distinct advantages over traditional PD sensing techniques based on an electrical method, including immunity to electromagnetic interference (EMI), long range detection, simultaneous detection for multiple points, and exact location. In this study, we present a DAS system for PD detection with performance evaluation and experimental results in a simulated environment. The results show that the system can be applied to PD detection.