• Title/Summary/Keyword: simultaneous faults

Search Result 29, Processing Time 0.025 seconds

RF-magnetron sputtering 방법으로 성장시킨 Ga-doped ZnO 박막의 성장 온도 변화에 따른 영향

  • Kim, Yeong-Lee;U, Chang-Ho;An, Cheol-Hyeon;Bae, Yeong-Suk;Gong, Bo-Hyeon;Kim, Dong-Chan;Jo, Hyeong-Gyun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.9-9
    • /
    • 2009
  • 1 wt % Ga-dope ZnO (ZnO:Ga) thin films with n-type semiconducting behavior were grown on c-sapphire substrates by radio frequency magnetron sputtering at various growth temperatures. The room temperature grown ZnO:Ga film showed the faint preferred orientation behavior along the c-axis with small domain size and high density of stacking faults, despite limited surface diffusion of the deposited atoms. The increase in the growth temperature in the range between $300\sim550^{\circ}C$ led to the granular shape of epitaxial ZnO:Ga films due to not enough thermal energy and large lattice mismatch. The growth temperature above $550^{\circ}C$ induced the quite flat surface and the simultaneous improvement of electrical carrier concentration and carrier mobility, $6.3\;\times\;10^{18}/cm^3$ and $27\;cm^2/Vs$, respectively. In addition, the increase in the grain size and the decrease in the dislocation density were observed in the high temperature grown films. The low-temperature photoluminescence of the ZnO:Ga films grown below $450^{\circ}C$ showed the redshift of deep-level emission, which was due to the transition from $Zn_j$ to $O_i$ level.

  • PDF

Measurement of Complex Permittivity and Permeability for Powder-type Materials (분말재료의 복소 유전율 및 투자율 측정)

  • Park, Sang-Bok;Lee, Jang-Soo;Chong, Young-Seek;Cheon, Chang-Yul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.12
    • /
    • pp.2196-2201
    • /
    • 2007
  • Materials used at microwave are usually used as a dielectric with a manufacturing purpose of printed circuit boards, etc. Complex permittivity of them can be measured from attenuation constant or propagation constant of a transmission line using a microstrip line with bulk type. But as the technique recently which can manufacture to have complex permittivity and permeability demanded using nonferrous metals for powder-type grows up, we need sensors and methods which can measure characteristics of powder-type materials. So far measuring methods of permittivity and permeability with waveguide or coaxial cable are used but they have faults which have a complex measurement method and are difficult to simultaneously measure permittivity and permeability. In this paper, a simultaneous measuring method of permittivity and permeability with 2-port coaxial cable and a new proposed calculation. The proposed 2-port coaxial cable is designed to be easy to insert materials and to have a wideband. We measure permittivity and permeability of magnetic powder(Ni-Fe-Mo, Ni-Fe) which reveal its characteristic at $0.3{\sim}1.3GHz$ to identify the proposed sensor.

Development of Arc-horn to be mounted on 154kV Transmission Line Arrester (154kV 송전선로 피뢰기 설치용 아킹혼 개발)

  • Min, Byeong-Wook;Kim, Woo-Kyum;Lee, Buk-Chang;Choi, Han-Yeol;Park, Jae-Ung;Keum, Eui-Yeon
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.335-336
    • /
    • 2008
  • Overhead transmission lines are mainly crossing mountainous area. They are easily affected in weathers like typhoon, strong wind, lightning, heavy rain, or heavy snow. Sometimes these weathers cause transmission line faults. A lightning flashover is most often fault. Nowadays lightning density in KOREA is growing high and lightning flashovers occur more often. A lightning flashover on transmission line is mostly cleared by momentary operation of a circuit breaker, so power failure happens rarely. However, when both circuits trip simultaneously due to the lightning flashovers on double circuit transmission line, short time power failure and voltage drop happen. KEPCO has used transmission line arresters to avoid double circuit simultaneous trip out since 2003. And transmission line arresters cannot be installed with KEPCO's present metal fittings, so various fittings have been used for each transmission line arrester manufacturer. This paper introduces development and standardization of arc-horn and metal fittings for transmission line arrester which can be used for both existing lines and new lines in KEPCO.

  • PDF

Simultaneous traveltime inversion of surface and borehole seismic data in Pungam basin (풍암분지 시험시추공 주변에서의 지표 및 시추공 초동주시 동시역산)

  • Kim, Ki-Yeong;Hong, Myung-Ho
    • Journal of the Korean Geophysical Society
    • /
    • v.9 no.1
    • /
    • pp.37-45
    • /
    • 2006
  • Velocity structures were defined in the vicinty of the 140-m deep test borehole in the pungam basin through simultaneous inversion of surface seismic refraction and far-ofset VSP traveltime data. Seismicenergy generated at the surface by a seisgun was recorded both at 42 surface locations at 3-m intervalsalong the profiles in the N20E and its orthogonal directions and at 71 m depth in the borehole. Forthe ofset VSP study, seismic energy was generated by a 5 kg sledgehamer at the surface in the horizontal ofset range of -19.5∼+19.5 m from the borehole. The seismic signals were detected at 9∼99 m depths with 1∼2 m intervals and recorded for 204 ms per shot. After shot static corrections,first-arrival times picked from both the surface refraction and borehole records were simultaneouslyinverted to yield velocity tomograms. The tomograms indicate that a 1.5 m thick soil layer with velocities les than 500 m/s overlies basements having a velocity range of 3,067 ∼5,717 m/s. Within the basements,∼4 m and deeper than 71 m. The high-velocit yzones may be due to conglomerates intercalated with sandstones and siltstones. No evidence for large-scale fracture zones or faults is detected near the borehole

  • PDF

Technique for Placing Continuous Media on a Disk Array under Fault-Tolerance and Arbitrary-Rate Search (결함허용과 임의 속도 탐색을 고려한 연속 매체 디스크 배치 기법)

  • O, Yu-Yeong;Kim, Seong-Su;Kim, Jae-Hun
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.26 no.9
    • /
    • pp.1166-1176
    • /
    • 1999
  • 연속 매체, 특히 비디오 데이타에 대한 일반 사용자 연산에는 재생뿐만 아니라 임의 속도 탐색 연산, 정지 연산, 그리고 그 외 다양한 연산이 있다. 이 연산 중에서 원하는 화면을 빨리 찾는 데에 유용한 고속 전진(FF: fast-forward)과 고속 후진(FB: fast-backward)은 재생 연산과는 달리 비순차적인 디스크 접근을 요구한다. 이러한 경우에 디스크 부하가 균등하지 않으면 일부 디스크에 접근이 편중되어 서비스 품질이 떨어진다. 본 논문에서는 디스크 배열을 이용한 저장 시스템에서 디스크 접근을 고르게 분산시키기 위하여 '소수 라운드 로빈(PRR: Prime Round Robin)' 방식으로 연속 매체를 디스크에 배치하는 기법에서 문제가 됐던 낭비된 디스크 저장 공간을 신뢰도 향상을 위해서 사용하는 '그룹화된 패리티를 갖는 소수 라운드 로빈(PRRgp: PRR with Grouped Parities)' 방식을 제안한다. 이 기법은 PRR 기법처럼 임의 속도 검색 연산에 있어서 디스크 배열을 구성하는 모든 디스크의 부하를 균등하게 할뿐만 아니라 낭비됐던 디스크 저장 공간에 신뢰도를 높이기 위한 패리티 정보를 저장함으로서 신뢰도를 향상시킬 수 있다. 신뢰도 모델링 방법으로 조합 모델과 마르코프 모델을 이용해서 결함발생율과 결함복구율을 고려한 신뢰도를 산출하고 비교.분석한다. PRR 기법으로 연속 매체를 저장하고 낭비되는 공간에 패리티 정보를 저장할 경우에 동시에 두 개 이상의 결함 발생 시에 그 결함으로부터 복구가 불가능하지만 PRRgp 기법에서는 약 30% 이상의경우에 대해서 동시에 두 개의 결함 발생 시에 저장한 패리티 정보를 이용한 복구가 가능할 뿐만 아니라 패리티 그룹의 수가 두 개 이상인 경우에는 두 개 이상의 결함에 대해서도 복구가 가능하다.Abstract End-user operations on continuous media (say video data) consist of arbitrary-rate search, pause, and others as well as normal-rate play. FF(fast-forward) / FB(fast-backward) among those operations are desirable to find out the scene of interest but they require non-sequential access of disks. When accesses are clustered to several disks without considering load balance, high quality services in playback may not be available. In this paper, we propose a new disk placement scheme, called PRRgp(Prime Round Robin with Grouped Parities), with enhanced reliability by using the wasted disk storage space in an old one(PRR: Prime Round Robin), in which continuous media are placed on a disk array based storage systems to distribute disk accesses uniformly. The PRRgp can not only achieve load balance of disks consisting of a disk array under arbitrary-rate search like PRR, but also improve reliability by storing parity information on the wasted disk space appropriately. We use combinatorial and Markov models to evaluate the reliability for a disk array and to analyze the results. When continuous media like PRR are placed and parity information on the wasted disk space is stored, we cannot tolerate more than two simultaneous faults. But they can be recovered by using stored parity information for about 30 percent as a whole in case of PRRgp presented in this paper. In addition, more than two faults can be tolerated in case there are more than two parity groups.

Design of Fault Diagnostic and Fault Tolerant System for Induction Motors with Redundant Controller Area Network

  • Hong, Won-Pyo;Yoon, Chung-Sup;Kim, Dong-Hwa
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.371-374
    • /
    • 2004
  • Induction motors are a critical component of many industrial processes and are frequently integrated in commercially available equipment. Safety, reliability, efficiency, and performance are some of the major concerns of induction motor applications. Preventive maintenance of induction motors has been a topic great interest to industry because of their wide range application of industry. Since the use of mechanical sensors, such as vibration probes, strain gauges, and accelerometers is often impractical, the motor current signature analysis (MACA) techniques have gained murk popularity as diagnostic tool. Fault tolerant control (FTC) strives to make the system stable and retain acceptable performance under the system faults. All present FTC method can be classified into two groups. The first group is based on fault detection and diagnostics (FDD). The second group is independent of FDD and includes methods such as integrity control, reliable stabilization and simultaneous stabilization. This paper presents the fundamental FDD-based FTC methods, which are capable of on-line detection and diagnose of the induction motors. Therefore, our group has developed the embedded distributed fault tolerant and fault diagnosis system for industrial motor. This paper presents its architecture. These mechanisms are based on two 32-bit DSPs and each TMS320F2407 DSP module is checking stator current, voltage, temperatures, vibration and speed of the motor. The DSPs share information from each sensor or DSP through DPRAM with hardware implemented semaphore. And it communicates the motor status through field bus (CAN, RS485). From the designed system, we get primitive sensors data for the case of normal condition and two abnormal conditions of 3 phase induction motor control system is implemented. This paper is the first step to drive multi-motors with serial communication which can satisfy the real time operation using CAN protocol.

  • PDF

A Study on Nonlinear GPA for Optimal Measurement Parameter Selection of Turboprop Engine (터보프롭 엔진의 최적 계측 변수 선정을 위한 비선형 GPA 기법에 관한 연구)

  • 공창덕;기자영
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.5 no.1
    • /
    • pp.69-75
    • /
    • 2001
  • Linear GPA(Gas Path Analysis) and non-linear GPA programs for performance diagnostics of a turboprop engine were developed, and a study for selection of optimal measurement variables was performed. Simultaneous faults in the compressor, the compressor turbine and the power turbine, which occur damage of the engine, were assumed. The non-linear GPA analysis was carried out with an iterative method, where the performance degradation rate of independent parameters was divided into same intervals. It was compared with the result by the Newton-Raphson method for observing the effect of an iterative method. According to the analysis result, it was found that performance of non-linear GPA can be influenced on the type of the iterative method. For showing effects of the number of measurement variables both the linear and non-linear GPAs were analyzed with 10, 8 and 6 measurement sets, respectively. RMS error between them were compared each other. It was realized that the more measurement parameters are used, and the more accurate result may be obtained. However much better result can be obtained with measurement parameters selected properly Moreover, RMS error by using non-linear GPA was less than that by using linear GPA.

  • PDF

Design of Network-Based Induction Motors Fault Diagnosis System Using Redundant DSP Microcontroller with Integrated CAN Module (DSP 마이크로컨트롤러를 사용한 CAN 네트워크 기반 유도전동기고장진단 시스템 설계)

  • Yoon, Chung-Sup;Hong, Won-Pyo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.5
    • /
    • pp.80-86
    • /
    • 2005
  • Induction motors are a critical component of many industrial processes and are frequently integrated in commercially available equipment. Safety, reliability, efficiency, and performance are some of the major concerns of induction motor applications. Fault tolerant control (FTC) strives to make the system stable and retain acceptable performance under the system faults. All present FTC method can be classified into two groups. The first group is based on fault detection and diagnostics (FDD). The second group is includes of FDD and includes methods such as integrity control, reliable stabilization and simultaneous stabilization. This paper presents the fundamental FDD-based FTC methods, which are capable of on-line detection and diagnose of the induction motors. Therefore, our group has developed the embedded distributed fault tolerant and fault diagnosis system for industrial motor. This paper presents its architecture. These mechanisms are based on two 32-bit DSPs and each TMS320F2407 DSP module processes the stator current, voltage, temperatures, vibration signal of the motor.

Model-Based Approach to Flight Test System Development to Cope with Demand for Simultaneous Guided Missile Flight Tests (동시다발적인 유도무기 비행시험 수요에 대응하기 위한 모델기반 비행시험 시스템 개발)

  • Park, Woong;Lee, Jae-Chon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.1
    • /
    • pp.268-277
    • /
    • 2019
  • Flight test systems should monitor various conditions in real time during flight tests and take safety measures in an emergency. The importance of ensuring test safety increases in more complicated and wider test environments. Also, due to the transition of wartime operational authority, many guided missile systems must be developed simultaneously. Early deployment and budget reduction by shortening the development and T&E periods are also necessary. Consequently, the risk of flight tests under the circumstance of inefficient test resources is increasing. To address this deficiency, a flight test system model using SysML was proposed in this study. The method of designing and verifying the test system is based on the agile shift left testing methodology of advanced T&E labs and utilizing a system reference model in the aerospace field. Through modeling and simulation analysis, early identification and correction of faults resulting from inconsistent test requirements can mitigate the risk of delays during the T&E phase of flight tests. Also, because the flight test system model was constructed using SysML, it can be applied to test various guided missile systems.