• 제목/요약/키워드: simultaneous and sequential procedure

검색결과 6건 처리시간 0.016초

Optimization of filling process in RTM using genetic algorithm

  • Kim, Byoung-Yoon;Nam, Gi-Joon;Ryu, Ho-Sok;Lee, Jae-Wook
    • Korea-Australia Rheology Journal
    • /
    • 제12권1호
    • /
    • pp.83-92
    • /
    • 2000
  • In resin transfer molding (RTM) process, preplaced fiber mat is set up in a mold and thermoset resin is injected into the mold. An important interest in RTM process is to minimize cycle time without sacrificing part quality or increasing cost. In this study, the numerical simulation and optimization process in filling stage were conducted in order to determine the optimum gate locations. Control volume finite element method (CVFEM) was used in this numerical analysis with the coordinate transformation method to analyze the complex 3-dimensional structure. Experiments were performed to monitor the flow front to validate simulation results. The results of numerical simulation predicted well the experimental results with every single, simultaneous and sequential injection procedure. We performed the optimization analysis for the sequential injection procedure to minimize fill time. The complex geometry of an automobile bumper core was chosen. Genetic algorithm was used in order to determine the optimum gate locations with regard to 3-step sequential injection case. These results could provide the information of the optimum gate locations in each injection step and could predict fill time and flow front.

  • PDF

Unified methods for variable selection and outlier detection in a linear regression

  • Seo, Han Son
    • Communications for Statistical Applications and Methods
    • /
    • 제26권6호
    • /
    • pp.575-582
    • /
    • 2019
  • The problem of selecting variables in the presence of outliers is considered. Variable selection and outlier detection are not separable problems because each observation affects the fitted regression equation differently and has a different influence on each variable. We suggest a simultaneous method for variable selection and outlier detection in a linear regression model. The suggested procedure uses a sequential method to detect outliers and uses all possible subset regressions for model selections. A simplified version of the procedure is also proposed to reduce the computational burden. The procedures are compared to other variable selection methods using real data sets known to contain outliers. Examples show that the proposed procedures are effective and superior to robust algorithms in selecting the best model.

선형회귀에서 변수선택, 변수변환과 이상치 탐지의 동시적 수행을 위한 절차 (A procedure for simultaneous variable selection, variable transformation and outlier identification in linear regression)

  • 서한손;윤민
    • 응용통계연구
    • /
    • 제33권1호
    • /
    • pp.1-10
    • /
    • 2020
  • 본 연구에서는 선형회귀모형에서 이상치와 변수변환을 고려한 변수선택 알고리즘을 다룬다. 제안된 방법은 잠재적 이상치를 탐지하여 제거한 후 변수변환 추정을 위해 최소 절사 제곱 추정법을 적용하며 가능한 모든 회귀모형을 비교하여 최종적으로 변수를 선택한다. 정확한 변수 선택과 추정된 모델의 적합도의 맥락에서 방법의 효율성을 보여주기 위해 실제 데이터 분석 및 시뮬레이션 결과가 제시된다.

Optimal endoscopic drainage strategy for unresectable malignant hilar biliary obstruction

  • Itaru Naitoh;Tadahisa Inoue
    • Clinical Endoscopy
    • /
    • 제56권2호
    • /
    • pp.135-142
    • /
    • 2023
  • Endoscopic biliary drainage strategies for managing unresectable malignant hilar biliary obstruction differ in terms of stent type, drainage area, and deployment method. However, the optimal endoscopic drainage strategy remains unclear. Uncovered self-expandable metal stents (SEMS) are the preferred type because of their higher functional success rate, longer time to recurrent biliary obstruction (RBO), and fewer cases of reintervention than plastic stents (PS). Other PS subtypes and covered SEMS, which feature a longer time to RBO than PS, can be removed during reintervention for RBO. Bilateral SEMS placement is associated with a longer time to RBO and a longer survival time than unilateral SEMS placement. Unilateral drainage is acceptable if a drainage volume of greater than 50% of the total liver volume can be achieved. In terms of deployment method, no differences were observed in clinical outcomes between side-by-side (SBS) and stent-in-stent deployment. Simultaneous SBS boasts a shorter procedure time and higher technical success rate than sequential SBS. This review of previous studies aimed to clarify the optimal endoscopic biliary drainage strategy for unresectable malignant hilar biliary obstruction.

용해도에 따라 노출기준이 다른 금속화합물의 정량방법 고찰 (Review of the Determination Methods for Metal Compounds with Different Occupational Exposure Limits Depending on Solubility)

  • 박승현;노지원;장미연
    • 한국산업보건학회지
    • /
    • 제30권2호
    • /
    • pp.87-98
    • /
    • 2020
  • Objective: The purpose of this study was to propose a sequential procedure for the simultaneous analysis of soluble and insoluble metal compounds. Methods: Methods for sampling and analyzing metal compounds such as ISO standards, NIOSH methods, HSE methods, and OSHA methods were reviewed. Results: Some metals have different OELs depending on the solubility of the compound. Therefore, we should take into account these characteristics and perform an exposure assessment. Soluble metal compounds are first extracted from the filter, and then the filter is digested by acids to analyze residual insoluble components. The extraction of soluble compounds can be completed by agitation for about 60 minutes with a leach solution (water) in a water bath at 37℃. For the analysis of insoluble compounds, the sample filter and the filtration filter remaining after the extraction of the soluble compounds are analyzed. This allows simultaneous determination of soluble and insoluble metal compounds. For hexavalent chromium compounds, soluble hexavalent chromium can first be extracted from the filter by using sulfate buffer. The insoluble hexavalent chromium remaining in the filter can then be extracted using carbonate buffer. Conclusion: Workers are often exposed to many hazardous substances with different exposure limits at industrial sites. The OELs for compounds of the same metal can be set differently depending on solubility. This study can help evaluate a worker's exposure to metal compounds by suggesting methods for the simultaneous determination of soluble and insoluble metal compounds.