• Title/Summary/Keyword: simultaneous

Search Result 6,456, Processing Time 0.032 seconds

A Study on the Test Results and Wideband Observing of the Korean VLBI Network (KVN의 광대역 관측 시험 및 결과고찰)

  • Oh, Se-Jin;Oyama, Tomoaki;Yeom, Jae-Hwan;Nishikawa, Takashi;Roh, Duk-Gyoo;Kim, Seung-Rae;Lee, Eui-Gyeom;Je, Do-Heung;Byun, Do-Young;Lee, Seong-Mo;Chung, Hyun-Soo
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.17 no.2
    • /
    • pp.83-92
    • /
    • 2016
  • In this paper, we introduce the results of the testing and observation systems for performance wideband expansion in the Korean VLBI Network(KVN). The KVN performs VLBI observations to 1024 Mbps data rate, and 8192 Mbps observing for four simultaneous observation is now evaluating for normal operation. The VLBI stations in several world countries developed their own wideband observing systems to observe the celestial objects with high precision and high resolution or are working with several countries. The KVN is planning to introduce a high-speed sampler, OCTAD, for sampling directly up to 2048 MHz bandwidth for RF signal of K/Q/W/D band in the frequency band without conversion. Therefore, as a preliminary study for the performance scalability of the KVN then through the close cooperation with National Astronomical Observatory of Japan (NAOJ), the OCTAD high-speed sampler and OCTADISK2 high-speed recorder were installed in the KVN Yonsei station, and verify the performance through a wideband.

Analysis on Energy Demand Resulting From the Change in Window Area & Installation of Interior Exterior Blinds (기존 노후건축물의 최적 리모델링 개선안 연구)

  • Kim, Dae-Won;Chung, Kwang-Seop;Kim, Young-Il;Nam, Ariasae;Oh, Se Min
    • Journal of Energy Engineering
    • /
    • v.23 no.2
    • /
    • pp.207-216
    • /
    • 2014
  • The energy loss can be divided into the loss caused by heat transfer and the loss caused by air flow. Heat transfer is the loss resulting from the heat transmittance of external wall, roof, and floor, and represents one of the most vulnerable elements of existing buildings. To prevent such loss, it is necessary to increase the mean heat transmittance of entire external wall, including the window, to a level above the standard regional value and ensure the air-tightness of window. The old buildings have the structure which is prone to the loss of greater air flow due to the air infiltration through the exit/entrance door upward along the stairway by the stack effect and simultaneous suction of air from each floor, and becomes even vulnerable to the loss of heat insulation for each floor, although the external wall and windows are the most vulnerable parts. The improvement plans for each floor need to be submitted in tandem with the diagnosis of whole building, regarding the diagnosis plan and energy improvement measures based on the survey of site, rather than adhering to the misconception that the replacement of window alone will result in energy-savings.

Analysis of Synthetic Fragrances (SFs) in Water Using Stir Bar Sorptive Extraction (SBSE) and GC-MS/MS (교반막대 추출법과 GC-MS/MS를 이용한 수중의 합성 향물질류 분석)

  • Seo, Chang-Dong;Son, Hee-Jong;Yoom, Hoon-Sik;Choi, Jin-Taek;Ryu, Dong-Choon;Kwon, Ki-Won;Jang, Seung-Ho
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.6
    • /
    • pp.387-395
    • /
    • 2014
  • A highly sensitive analytical method based on stir bar sorptive extraction (SBSE) technique and gas chromatography/tandem mass spectrometry (GC-MS/MS) has been developed, allowing the simultaneous multi-analyte determination of 11 synthetic fragrances (SFs) in water samples. The stir bar coated with polydimethylsiloxane (PDMS) was added to 40 mL of water sample at pH 3 and stirred at 1,100 rpm for 120 min. Other SBSE parameters (salt effect and presence of organic solvent) were optimised. The method shows good linearity (coefficients > 0.990) and reproducibility (RSD < 10.9%). The extraction efficiencies were above 83% for all the compounds. The limits of detections (LOD) and limits of quantification (LOQ) were 2.1~4.1 ng/L and 6.6~12.9 ng/L, respectively. The developed method offers the ability to detect 11 SFs at ultra-low concentration levels with only 40 mL of sample volume. Matrix effects in tap water, river water, wastewater treatment plant (WWTP) final effluent water and seawater were investigated and it was shown that the method is suitable for the analysis of trace level of 11 SFs. The method developed in the present study has the advantage of being rapid, simple, high-sensitive and both user and environmentally friendly.

3-D Crustal Velocity Tomography in the Southern Part of The Korean Peninsula (한반도 남부지역의 3-D 속도 토모그래피)

  • Kim, So Gu;Li, Qinghe
    • Economic and Environmental Geology
    • /
    • v.31 no.2
    • /
    • pp.127-139
    • /
    • 1998
  • A new technique of simultaneous inversion for 3-D seismic velocity structure by using direct, reflected, and refracted waves is applied to the southeast part of the Korean Peninsula including Pohang Basin, Kyongsang Basin and Ryongnam Massif. Pg, Sg, PmP, SmS, Pn, and Sn arrival times of 44 events with 554 seismic rays are inverted for locations and crustal structure. $6{\times}6$ with $0.5^{\circ}$ and 8 layers (4 km each layer) model was inverted. 3-D seismic crustal velocity tomography including eight sections from surface to Moho, ten profiles along latitude and longitude are analyzed. The results are as follows: 1) the average velocity and thickness of sediment are 5.04 km/s and 3-4 km, and the velocity of basement is 6.11 km/s. The shape of velocity in shallower layer is agreement with Bouguer gravity anomaly (Cho et al., 1997). 2) the velocities fluctuate strongly in the upper crust. The velocity distribution of the lower crust under Conrad appears basically horizontal. 3) the average depth of Moho is 30.4 km, and velocity is 8.01 km/s. 4) from the velocity and depth of the sediment, the thickness, velocity and form of the upper crust, and the depth and form of Moho, we can find the obvious differences among Ryongnam Massif, Kyongsang Basin and Pohang Basin. 5) the deep faults (a Ulsan series faults) near Kyongju and Pohang areas can be found to be normal and/or thrust faults with detachment extended to the bottom of the upper crust.

  • PDF

Determination of Sildenafil and Its Related Substances Using High Performance Thin Layer Chromatography (고성능 박층 크로마토그래프를 이용한 실데나필과 그 유사 물질의 정량에 관한 연구)

  • Choi, Hyun-Cheol;Kang, Sin-Jung;Yun, Mi-Ok;Park, Sang-Aeh;Kim, Ho-Jeong;We, Sae-Seung;Kim, Ja-Yeon;Cha, Ki-Won
    • Analytical Science and Technology
    • /
    • v.16 no.1
    • /
    • pp.32-38
    • /
    • 2003
  • The rapid and sensitive determination method of sildenafil and its related compounds (Vardenafil, Homosildenafil, Tadanafil.) has been investigated using high performance thin layer choromatography (HPTLC). Optimizing separation conditions and simultaneous determination method of these compounds were studied. The calibration curves of those compounds at 254 nm was found to be linear in the range of $1.0{\sim}56.5{\mu}g/mL$, respectively. The detection limts (LOD) and quantification limits (LOQ) of these were found to be $0.8{\sim}1.8{\mu}g/mL$ and $1.0{\sim}2.3{\mu}g/mL$. The coefficient of variation (C.V.) were less than 2.5%. Finally, the present method was applied to determine sildenafil and its related substances in dietary supplement.

Simultaneous analysis of β-lactam antibiotics and β-blockers by LC-MS/MS (LC-MS/MS를 이용한 베타락탐계 항생제와 베타차단제의 동시분석)

  • Son, Bo-young;Kim, Jun-il;An, Chi-hwa;Lee, Su-won;Kim, Bogsoon;Chung, Deukmo
    • Analytical Science and Technology
    • /
    • v.29 no.4
    • /
    • pp.179-185
    • /
    • 2016
  • An effective analytical method has been developed for the determination of β-blockers(atenolol, metoprolol and propranolol) and 6 β-lactams(amoxicillin, penicillin G, cefaclor, cefadroxil, cephalexin and cephradine) in water samples using two different cartridges. The samples were extracted by solid-phase extraction (SPE) with the usage of polymeric hydrophile-lipophile balance(HLB cartridges) and strong cation-exchange mixed-mode polymeric sorbent (MCX cartridges). A XDB-C18 column(1.8 μm; 3.0 mm × 100 mm) was used for the sufficient chromatographic resolution. The calibration curves showed good linearity with high correlation coefficients (>0.995). The method detection limits (MDL) and the limits of quantification(LOQ) were from 1.1 to 3.9 ng/L and from 5 to 13 ng/L, respectively. The method was applied for the determination of the target compounds in tributaries and raw water of the Han River and these were found at N.D. to 0.209 μg/L.

Development of HPLC-UV method for detection and quantification of seven organic acids in animal feed (사료 중 유기산 7종 동시분석법 개발 및 유통 사료의 모니터링)

  • Kim, Jin kug;Lee, Mi Jin;Lee, Ye Ji;Kim, Hye Jin;Jeong, Min Hee;Kim, Ho Jin
    • Analytical Science and Technology
    • /
    • v.29 no.4
    • /
    • pp.202-208
    • /
    • 2016
  • 본 연구에서는 사료 첨가제로 이용되고 있는 유기산 7종(formic acid, malic acid, lactic acid, acetic acid, citric acid, fumaric acid, propionic acid)의 동시분석법 개발을 위한 연구를 실시하였다. 7종의 화합물은 표준물질의 Retention time과 UV spectra를 통해 구별하였고, 분석법 검증은 직선성, 민감성, 선택성, 정확성, 정밀성을 통하여 검증하였다. 그 결과로 LOD와 LOQ의 범위가 각각 43~26,755 μg/kg, 12-8,026 μg/kg으로 설정하였고, 평균 회수율이 79.3~95.2%로 우수하게 보였으며, intra-day, inter-day에 대한 전반적인 상대 표준 편차(%RSD)는 3.2% 미만으로 나타났다. 이와 같이 검증된 자료를 통해 유기산의 동시분석에 대한 직선성, 민감성, 선택성, 정확성 및 정밀성을 확인하였고, 높은 수준을 나타냄을 알 수 있었다. 이를 바탕으로 유기산이 검출되는 단미사료 46 가지를 분석에 적용하여 진행하였고, 정량과 동시분석 검출을 위한 방법은 RP-HPLC/UV 검출기를 이용하여 성공적으로 개발되었다. 따라서 본 연구결과를 바탕으로 하여 사료 중의 유기산의 분석이 신속하고 정확해졌을 뿐 아니라, 다른 종류의 사료 또한 이를 적용하여 효율적으로 이용할 수 있을 것으로 판단된다.

Development and validation of a HPLC method for the simultaneous determination of chlorquinaldol and promestriene in complex prescription (복방제제 내 클로르퀴날돌과 프로메스트리엔에 대한 HPLC 기반 동시분석법의 개발 및 밸리데이션)

  • Lee, Seul-Ji;Shin, Sang-Yeon;Shin, Hae-Jin;Lee, Jin-Gyun;Kim, Dong-Hwan;Lee, Su-Jung;Han, Sang-Beom;Park, Jeong-Hill;Lee, Jeong-Mi;Kwon, Sung-Won
    • Analytical Science and Technology
    • /
    • v.25 no.2
    • /
    • pp.152-157
    • /
    • 2012
  • Currently, many types of compound preparations are being used but the quality control guidelines for their use are lacking. In case of single compound drug, the quality control methods are specified in the pharmacopeia. However, there is no method to simultaneously analyze compound preparations. In this study, a simple validated analytical method for HPLC separation of chlorquinaldol and promestriene is introduced. Validation was divided into categories including linearity, precision, accuracy (recovery) and system suitability. The contents of the products which are on the market were monitored using the validated analytical method and the robustness of the analytical method was tested by conducting an inter-laboratory validation.

Design of Electromechanical Actuator Capable of Simultaneous Control of Aerodynamic and Thrust Vector (공력과 추력방향 동시 제어가 가능한 전기식 구동장치 설계)

  • Lee, Ha Jun;Yoon, Kiwon;Song, In Seong;Park, Chang Kyoo;Lee, Young Cheol
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.48 no.1
    • /
    • pp.35-42
    • /
    • 2020
  • Electromechanical Actuator(EMA) for flight vehicles generally serves to control the fin deflection angle or the thrust vector angle. This paper deals with design and development of EMA for both aerodynamic control and thrust vector control. In this paper, a novel compact EMA is proposed that can simultaneously control both the tail fin and the jet vane with one actuator and detach the jet vane after vertical launch and rapid turn of the flight vehicle so as to increase efficiency during flying to target. To do this, we designed the EMA using a push-push link mechanism and derived a mathematical model. The mathematical model is validated by comparing simulation result and experimental data. The performance and reliability of the proposed EMA have been verified through performance test, environmental test and ground test. The proposed EMA is expected to be useful as an EMA for flight vehicles because of its simple and compact structure, as well as its performance and reliability.

R-(-)-TNPA, a Dopaminergic $D_2$ Receptor Agonist, Inhibits Catecholamine Release from the Rat Adrenal Medulla

  • Hong, Soon-Pyo;Seo, Hong-Joo;Lim, Dong-Yoon
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.10 no.5
    • /
    • pp.273-282
    • /
    • 2006
  • The aim of the present study was to investigate the effects of R-(-)-2,10,11-trihydroxy-N-propylnoraporphine [R-(-)-TNPA], a selective agonist of dopaminergic $D_2$ receptor and S(-)-raclopride, a selective antagonist of dopaminergic $D_2$ receptor, on the secretion of catecholamines (CA) evoked by cholinergic stimulation and membrane-depolarization in the isolated perfused model of the rat adrenal gland, and also to establish its mechanism of action. R-(-)-TNPA $(10{\sim}100\;{\mu}M)$ perfused into an adrenal vein for 60 min produced dose- and time-dependent inhibition in CA secretory responses evoked by ACh (5.32 mM), high $K^+$ (56 mM), DMPP $(100\;{\mu}M)$ and McN-A-343 $(100\;{\mu}M)$. R-(-)-TNPA itself did also fail to affect basal CA output. Also, in adrenal glands loaded with R-(-)-TNPA $(30\;{\mu}M)$, the CA secretory responses evoked by Bay-K-8644 $(10\;{\mu}M)$, an activator of L-type $Ca^2+$ channels and cyclopiazonic acid $(10\;{\mu}M)$, an inhibitor of cytoplasmic $Ca^{2+}-ATPase$ were also inhibited. However, S(-)-raclopride $(1{\sim}10\;{\mu}M)$, given into an adrenal vein for 60 min, enhanced the CA secretory responses evoked by ACh, high $K^+$, DMPP and McN-A-343 only for the first period (4 min), although it alone has weak effect on CA secretion. Moreover, S(-)-raclopride $(3.0\;{\mu}M)$ in to an adrenal vein for 60 min also augmented the CA release evoked by BAY-K-8644 and cyclopiazonic acid only for the first period (4 min). However, after simultaneous perfusion of R-(-)-TNP A $(30\;{\mu}M)$ and S(-)-raclopride $(3.0\;{\mu}M)$, the inhibitory responses of R(-)-TNPA $(30\;{\mu}M)$ on the CA secretion evoked by ACh, high $K^+$, DMPP, McN-A-343, Bay-K-8644, and cyclopiazonic acid were significantly reduced. Taken together, these experimental results suggest that R-(-)-TNPA greatly inhibits the CA secretion from the perfused rat adrenal medulla evoked by cholinergic stimulation (both nicotininc and muscarinic receptors) and membrane depolarization, but S(-)-raclopride rather enhances the CA release by them. It seems that this inhibitory of R-(-)-TNPA may be mediated by stimulation of inhibitory dopaminergic $D_2$ receptors located on the rat adrenomedullary chromaffin cells, while the facilitatory effect of S(-)-raclopride is due to the blockade of dopaminergic $D_2$ receptors, which are relevant to extra- and intracellular calcium mobilization. Therefore, it is thought that dopaminergic $D_2$ receptors may be involved in regulation of CA release in the rat adrenal medulla.