• 제목/요약/키워드: simple system

검색결과 9,682건 처리시간 0.034초

Automatic Fortified Password Generator System Using Special Characters

  • Jeong, Junho;Kim, Jung-Sook
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • 제15권4호
    • /
    • pp.295-299
    • /
    • 2015
  • The developed security scheme for user authentication, which uses both a password and the various devices, is always open by malicious user. In order to solve that problem, a keystroke dynamics is introduced. A person's keystroke has a unique pattern. That allows the use of keystroke dynamics to authenticate users. However, it has a problem to authenticate users because it has an accuracy problem. And many people use passwords, for which most of them use a simple word such as "password" or numbers such as "1234." Despite people already perceive that a simple password is not secure enough, they still use simple password because it is easy to use and to remember. And they have to use a secure password that includes special characters such as "#!($^*$)^". In this paper, we propose the automatic fortified password generator system which uses special characters and keystroke feature. At first, the keystroke feature is measured while user key in the password. After that, the feature of user's keystroke is classified. We measure the longest or the shortest interval time as user's keystroke feature. As that result, it is possible to change a simple password to a secure one simply by adding a special character to it according to the classified feature. This system is effective even when the cyber attacker knows the password.

광디스크 드라이브를 위한 강인 제어기 설계 (Robust Servo System for Optical Disk Drive Systems)

  • 박범호;정정주;표현봉;박용우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 학술회의 논문집 정보 및 제어부문 B
    • /
    • pp.380-383
    • /
    • 2003
  • This paper proposes a new and simple input prediction method for robust servo system. This servo system uses robust tracking control system based on both Coprime Factorization(CF) and Zero Phase Error Tracking control system. The CF control system can be designed simply and systematically. Moreover, this system has not only stability but also robustness and disturbance rejection ability The optical disk tracking servo system can detect only the tracking error. So the new and simple input prediction system proposed in this paper estimates the reference input signal from the tracking error. Numerical simulation results show that the proposed method is effective.

  • PDF

두 열적 단순계로 구성된 복합계의 열역학 (Thermodynamics of a composite system composed of two simple thermal systems)

  • 정평석;김수연
    • 대한기계학회논문집B
    • /
    • 제21권2호
    • /
    • pp.275-284
    • /
    • 1997
  • Thermodynamic behavior of a composite system which is composed of two simple thermal subsystems with constant heat capacities is analyzed, and several thermodynamic phenomena are investigated. The changes of the states and the potential work of the composite system are shown as the interaction between the subsystems in the composite system. The potential work is defined as the possible maximum available work from the composite system, and it is a thermodynamic property of the composite system. The decrease of the potential work is the same as the available work output from the composite system in reversible processes. The dissipation of available work is directly connected to the generation of entropy. The concepts of exergy and internal energy can be explained as a special case of the potential work.

사상체질 진단 설문 활용도를 높이기 위한 웹 기반 체질진단 시스템 - KS-15(Korea Sasang Constitutional Diagnostic Questionnaire) - (The Web Application to Improve Utilization of Sasang Constitutional Diagnosis Questionnaire - KS-15(Korea Sasang Constitutional Diagnostic Questionnaire) -)

  • 박대일;박기현;진희정
    • 사상체질의학회지
    • /
    • 제29권3호
    • /
    • pp.224-231
    • /
    • 2017
  • Objectives Several researches have been done to develop instruments or questionnaire for diagnosis of sasang constitution. In this study, we developed a user-friendly web system to enhance the utilization of KS-15. Methods The KS-15 Web application was constructed by considering the responsive web design and easy survey answer. This system is designed only to authorized users for security purposes, and provides two modes, simple mode and expert mode, depending on the purpose of using the system. A simple mode do not keep user information and survey answer in the database. An expert mode support management of patients, diagnosis of sasang constitution and statistical functions. Results & Conclusions The developed KS-15 system can be operated from any smart device's web browser. In order to use information in clinic field, it was developed so that it can be accessed only by authorized users. It can be divided into an account which can use only simple mode and an account which can use expert mode by using a difference in access authority. These functions can enhance the applicability of sasang constitution in real life such as clinical or education.

주위기체내에서의 두 액체분무간의 유동간섭현상에 대한 정상적 고찰 (An Experimental Study on the Behavior of Twin-Spray with Flow Interaction in a Condensable Environment)

  • 이상룡;정태식;한기수
    • 대한기계학회논문집
    • /
    • 제10권3호
    • /
    • pp.326-334
    • /
    • 1986
  • The effects of flow interaction between adjacent sprays in twin-spray system on the spatial distribution of injected liquid (water) and drop size distribution in condensable (steam) environment were carefully observed through experiments. The spatial distribution of injected liquid in twin-spray system appears to be more uniform than the simple superposition of the spatial distributions of liquid obtained from each individual spray. Drop size distribution was obtained by using the immersion sampling technique. It was found that, in the twin-spray, the larger numbers of small drops are collected throughout the spraying region due to the increase of entrainment velocity of ambient steam compared with the case of simple superposition of each individual spray. Moreover, in the overlapped portion of the twin-spray, the drop size distribution was changed also due to the collision between large drops. As a result, the behavior of twin-spray system (and eventually multiple-spray system) can not be predicted precisely by simple superposition of the behaviors of each constituting spray. Hence, for the design of multiple spray system, the effect of flow interaction between sprays should be taken into account seriously.

고성능 선형전동기 위치제어 시스템에 대한 최소차원 부하관측기의 실제적 구현 및 이를 이용한 실시간 관성추정기의 구현 (A Study on The Actual Application of the Least Order Load Observer and Effective Online Inertia Identification Algorithm for High Performance Linear Motor Positioning System)

  • 김준석
    • 전기학회논문지
    • /
    • 제56권4호
    • /
    • pp.730-738
    • /
    • 2007
  • As well known when the linear machine is operated between two points repeatedly under positioning control, there are various positioning error at the moment of zero speed owing to the non-linear disturbance like as unpredictable friction force. To remove this positioning error, a simple least order disturbance observer is introduced and is actually implemented in this study. Due to this simple algorithm the over-all machine system can be modified to simple arbitrary given one-mass load without any disturbance. So, the total construction process for positioning control system is much easier than old one. Moreover, to generate a proper effective position profile with the limited actual machine force, a very powerful on-line mass identification algorithm using the load force estimator is presented. In the proposed mass identification algorithm, the exact load mass can be calculated during only one moving stage under a normally generated position profile. All presented algorithm is verified with experimental result with commercial linear servo machine system.

The Microbe Removing Characteristics Caused by Dirty Water Using a Simple Pulsed Power System

  • Kim, Hee-je;Song, Keun-ju;Song, Woo-Jung;Kim, Su-Weon;Park, Jin--Young;Joung, Jong-Han
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제4C권3호
    • /
    • pp.91-95
    • /
    • 2004
  • The pulsed power system is widely available for use in pulse generator applications. Generally, the pulse generator is required for very short pulse width and high peak value. We have designed and fabricated our own pulsed type power system and through its use, we investigated microbe removal characteristics. This paper introduces a simple pulsed power system for removing various microbes caused by dirty water. This system includes a 2 times power supply circuit, IR2110 operated by using a fixed voltage regulator 7812 and 7805, and the switching MOSFET (Metal Oxide Semiconductor Field Effect Transistor). We can also control this process by using a PIC one chip microprocessor. As a result, we can obtain good removing characteristics of various microbes by adjusting the charging voltage, the pulse repetition rate and the electrical field inducing time.

Simple and Flexible Temperature Control System for Space Environment Test

  • Lee, Sang-Hoon;Cho, Hyok-Jin;Seo, Hee-Jun;Moon, Guee-Won;Choi, Seok-Weon
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 2008년도 한국우주과학회보 제17권2호
    • /
    • pp.29.1-29.1
    • /
    • 2008
  • The temperature control system which is using liquid and gaseous nitrogen has been known as the most economical system to simulate space temperature condition due to relatively not expansive price of the liquid nitrogen (less than 0.2 USD per liter). And, among these systems, the closed loop system which circulates compressed nitrogen gas come from sprayed liquid nitrogen by blower and makes a target temperature with heat from an electrical heater and flow rate of liquid nitrogen is prevail all over the world. But, this complete closed loop system requires expansive equipments such as blower, heater, and liquid nitrogen injector, and special maintenance on the system. Therefore, KARI is developing efficient and simple open loop system which utilizes liquid and gaseous nitrogen with eliminating a special blower and other expansive units. In this study, this open loop system with more efficiency and flexibility will be designed and introduced.

  • PDF

CPLD칩을 이용한 다채널 가스누출 경보시스템의 설계 및 제작 (Design and Fabrication of multi-channel gas leakage monitoring system using CPLD)

  • 정도운;정완영;이덕동
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1999년도 추계종합학술대회 논문집
    • /
    • pp.925-928
    • /
    • 1999
  • A multi-channel gas leakage monitoring system was designed and fabricated by using CPLD(complex Programmable Logic .Device) for monitoring and controlling the leakage of natural gas from supplying-pipes under the ground. Fabricated SnO$_2$thick film gas sensor elements were attached on safeguard steel plate of natural gas supplying pipes, and the local monitoring system in this study received the signal from the gas sensors. The monitoring system was implemented by using CPLD chip to reduce the development time and implement simple one chip system. The time division multi-channel system received the input signal from individual gas sensor at one of divided times by multiplexor and signal processed sequentially. The system reduced the size of peripheral circuit resulted in implementation of creditable simple system.

  • PDF

UTILIZING COUPLING STRATEGY TO GENERATE A NEW SIMPLE 7D HYPERCHAOTIC SYSTEM AND ITS CIRCUIT APPLICATION

  • Saad Fawzi Al-Azzawi
    • 대한수학회논문집
    • /
    • 제39권2호
    • /
    • pp.547-562
    • /
    • 2024
  • By utilizing coupling the strategy in the 5D Sprott B system, a new no equilibrium 7D hyperchaotic system is introduced. Despite the proposed system being simple with twelve-term, including solely two cross product nonlinearities, it displays extremely rich dynamical features such as hidden attractors and the dissipative and conservative nature. Besides, this system has largest Kaplan-Yorke dimension compared with to the work available in the literature. The dynamical properties are fully investigated via Matlab 2021 software from several aspects of phase portraits, Lyapunov exponents, Kaplan-Yorke dimension, offset boosting and so on. Moreover, the corresponding circuit is done through Multisim 14.2 software and preform to verify the new 7D system. The numerical simulations wit carryout via both software are agreement which indicates the efficiency of the proposed system.