• Title/Summary/Keyword: simple system

Search Result 9,694, Processing Time 0.036 seconds

Understanding Topical Relevance of Multimedia based on EEG Techniques (뇌파측정기술(EEG)에 기초한 멀티미디어 자료의 주제 적합성에 관한 연구)

  • Kim, Hyun-Hee;Kim, Yong-Ho
    • Journal of the Korean Society for Library and Information Science
    • /
    • v.50 no.3
    • /
    • pp.361-381
    • /
    • 2016
  • This study proposed two topical relevance models, simple and complex models, using EEG/ERP techniques. In the simple model regarding simple search tasks, N300 and P3b components are used. The N300 is specific to the semantic processing of pictures and the P3b reflects mechanisms involved in the decision about whether an external stimulus matches or does not match an internal representation of a specific category. In the complex model regarding complex search tasks, on the other hand, N400 and P600 components are used. The N400 reflects activation of an amodel system that integrates both image-based and conceptual representations into a context, whereas the P600 is related to complex cognitive processes. Our research results can be used as a source to design an EEG-based interactive multimedia system.

Comparison of IUHs obtained by the Derived and Simple Equation of GIUH on Third and Fourth-Order Streams (3, 4차 하천에서의 GIUH 유도식과 간략식에 의해 산정된 순간단위도의 비교연구)

  • Joo, Jin-Gul;Ham, Dae-Heon;Jun, Hwan-Don;Lee, Jung-Ho;Kim, Joong-Hoon
    • Journal of Korea Water Resources Association
    • /
    • v.41 no.11
    • /
    • pp.1107-1121
    • /
    • 2008
  • The simple equation of GIUH are frequently used in many researches instead of the derived equation of GIUH. However it is still unknown whether the simple equation of GIUH is adaptable for estimating IUHs for basins with various geomorphologic conditions. To verify the applicability of the simple equation of GIUH, in this research, four basins which were Bangrim, Sanganmi, Museong, and Byeongcheon were selected and each basin was assumed as the third and fourth stream order basin according to variable resolutions. After than, IUHs were estimated using the derived and simple equations of GIUH. Eight to sixteen hydrographs were estimated from the each IUH, compared with observed graphs. In case of that the basin is assumed as a third order stream, the derived equation underestimated the peak flows while the simple equation overestimated them. When the basin is assumed as a fourth order stream, the simple equation generally overestimated the peak flows whereas the derived equation produced peak flows good agreement with the observed peak flow. Moreover, the simple equation showed various deviations in accuracy whereas the derived equation produced stable results. Based on the fact found from this research, it can be concluded that the derived equation of GIUH brings better results than the simple equation of GIUH to estimate IUHs for ungauged basins.

Simple Decompression of the Ulnar Nerve for Cubital Tunnel Syndrome

  • Cho, Yong-Jun;Cho, Sung-Min;Sheen, Seung-Hoon;Choi, Jong-Hun;Huh, Dong-Hwa;Song, Joon-Ho
    • Journal of Korean Neurosurgical Society
    • /
    • v.42 no.5
    • /
    • pp.382-387
    • /
    • 2007
  • Objective : Cubital tunnel syndrome is the second most common entrapment neuropathy of the upper extremity. Although many different operative techniques have been introduced, none of them have been proven superior to others. Simple cubital tunnel decompression has numerous advantages, including simplicity and safety. We present our experience of treating cubital tunnel syndrome with simple decompression in 15 patients. Methods : According to Dellon's criteria, one patient was classified as grade 1, eight as grade 2, and six as grade 3. Preoperative electrodiagnostic studies were performed in all patients and 7 of them were rechecked postoperatively. Five patients of 15 underwent simple decompression using a small skin incision (2 cm or less). Results : Preoperative mean value of motor conduction velocity (MCV) within the segment (above the elbow-below the elbow) was $41.8{\pm}15.2\;m/s$ and this result showed a decrease compared to the result of MCV in the below the elbow-wrist segment ($57.8{\pm}6.9\;m/s$) with statistical significance (p<0.05). Postoperative mean values of MCV were improved in 6 of 7 patients from $39.8{\pm}12.1\;m/s$ to $47.8{\pm}12.1\;m/s$ (p<0.05). After an average follow-up of $4.8{\pm}5.3$ months, 14 patients of 15 (93%) reported good or excellent clinical outcomes according to a modified Bishop scoring system. Five patients who had been treated using a small skin incision achieved good or excellent outcomes. There were no complications, recurrences, or subluxation of the ulnar nerve. Conclusion : Simple decompression of the ulnar nerve is an effective and successful minimally invasive technique for patients with cubital tunnel syndrome.

A Study on the Characteristics of Thyristor Controlled Shunt Compensator (싸이리스터제어 병렬보상기의 특성 연구)

  • 정교범
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.4 no.4
    • /
    • pp.368-376
    • /
    • 1999
  • This paper studies the operational characteristics of thyristor controlled shunt compensator in a simple power t transmission system. With Fourier series representation of the thyristor switching action and the system parameters, t the thyristor current equations are derived, which transmit the required real power of the simple power transmission s system. Bisection algorithm is used to solve the thyristor current equations, which informs the thyristor firing an밍e, t the thyristor conduction an밍e, the power flows and the harmonic characteristics. The stability analysis is performed w with the theory of Poincare mapping for the nonlinear discrete periodic dynamic system. EMTP simulations at the v various operating points show the transient characteristics of the thyristor controlled shunt compensator and C correspond to the results calculated with Fourier series representation and the stability analysis.

  • PDF

Traffic Modeling and Analysis for Pedestrians in Picocell Systems Using Random Walk Model (Picocell 시스템의 보행자 통화량 모델링 및 분석)

  • Lee, Ki-Dong;Chang, Kun-Nyeong;Kim, Sehun
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.29 no.2
    • /
    • pp.135-144
    • /
    • 2003
  • Traffic performance in a microcellular system is much more affected by cell dwell time and channel holding time in each cell. Cell dwell time of a call is characterized by its mobility pattern, i.e., stochastic changes of moving speed and direction. Cell dwell time provides important information for other analyses on traffic performance such as channel holding time, handover rate, and the average number of handovers per call. In the next generation mobile communication system, the cell size is expected to be much smaller than that of current one to accommodate the increase of user demand and to achieve high bandwidth utilization. As the cell size gets small, traffic performance is much more affected by variable mobility of users, especially by that of pedestrians. In previous work, analytical models are based on simple probability models. They provide sufficient accuracy in a simple second-generation cellular system. However, the role of them is becoming invalid in a picocellular environment where there are rapid change of network traffic conditions and highly random mobility of pedestrians. Unlike in previous work, we propose an improved probability model evolved from so-called Random walk model in order to mathematically formulate variable mobility of pedestrians and analyze the traffic performance. With our model, we can figure out variable characteristics of pedestrian mobility with stochastic correlation. The above-mentioned traffic performance measures are analyzed using our model.

Analysis on Cooling and Heating Performance of Water-to-Water Heat Pump System for Water Source Temperature (물-물 수온차 히트펌프 시스템의 원수온도에 따른 성능 특성 분석)

  • Park, Tae Jin;Cho, Yong;Park, Jin-Hoon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.169.2-169.2
    • /
    • 2010
  • The research assesses the performance of the water-to-water heat pump system installed in Cheongju water treatment plant for cooling and heating ventilation. In summer season monthly averaged COP is ranged from 3.85 to 4.56 according to the water source temperature, and the performance is increased as the raw water temperature is dropped. While, heating performance is increased for the high temperature water source, and the monthly averaged COP is changed from 2.92 to 3.82. The correlation of the water source temperature and the heat pump performance shows a linear tendency by the simple regression of average data. In heating, the COP of heat pump system linearly rises according to the water source temperature. In comparison, the COP in cooling linearly reduces as the raw water temperature is raised. The goodness of fit at the simple regression shows the coefficient of determination 82% in cooling, 46% in heating. The electric cost of water-to-water heat pump is reduced by 40% compared to that of air source heat pump.

  • PDF

011-line Visual Feedback Control of Industrial Robot Manipulator (산업용 로봇 매니퓰레이터의 오프라인 영상피드백 제어)

  • 신행봉;정동연;김용태;이종두;이강두
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2002.04a
    • /
    • pp.567-572
    • /
    • 2002
  • The equipment of industrial robot in manufacturing and assembly lines has rapidly increased. In order to achieve high productivity and flexibility, it becomes very important to develop the visual feedback control system with Off-Line Programming System(OLPS ). We can save much efforts and time in adjusting robots to newly defined workcells by using Off-Line Programming System. A proposed visual calibration scheme is based on position-based visual feedback. The visual calibration system is composed of a personal computer, an image processing board, a video monitor, and one camera. The calibration program firstly generates predicted images of objects in an assumed end-effector position. The process to generate predicted images consists of projection to screen-coordinates, visible range test, and construction of simple silhouette figures. Then, camera images acquired are compared with predicted ones for updating position and orientation data. Computation of error is very simple because the scheme is based on perspective projection, which can be also expanded to experimental results. Computation time can be extremely reduced because the proposed method does not require the precise calculation of tree-dimensional object data and image Jacobian.

  • PDF

Development of a Simple Autonomous Vehicle for Greenhouse Works (온실용 간이 자율주행 작업차의 개발)

  • 이재환;류관희
    • Journal of Biosystems Engineering
    • /
    • v.21 no.4
    • /
    • pp.422-428
    • /
    • 1996
  • This study was conducted to developed to develop a simple battery-powered autonomous vehicle for greenhouse works. A steering method using speed difference of two independent driving motors was adopted. DC motor driving circuit, speed control circuit and controller using one-chip microcomputer were constructed. The inputs of controller are rolling of the vehicle and current speed of driving motors. Using these signals, automatic guidance system along furrow was developed. A computer simulation program by the kenematic analysis was developed to find out optimal control algorithm. The results of this study are as follows. 1. Automatic guidance system along the furrow that adopted two independent driving motors and rolling of vehicle was developed. 2. The results of simulation showed that PID control was adequate to automatic guidance system along furrow. 3. Two commercial 12V battery serially connected were able to drive the vehicle on the soil ground for five hours in continuous operation and for four hours in intermittent operation without recharging the battery. 4. The speed range was 0-0.7m/s and the rolling of vehicle could be controlled within $pm5^{\circ}$ range. 5. From a series of tests, developed vehicle was found to be a useful tool for greenhouse works.

  • PDF

Off-line Visual Feedback Control of Robot Manipulator (로봇 매니퓰레이터의 오프라인 영상피드백 제어)

  • 신행봉;정동연;이종두;이강두;한성현
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2001.10a
    • /
    • pp.140-145
    • /
    • 2001
  • The equipment of industrial robot in manufacturing and assembly lines has rapidly increased. In order to achieve high productivity and flexibility, it becomes very important to develop the visual feedback control system with Off-Line Programming System(OLPS). We can save much efforts and time in adjusting robots to newly defined workcells by using Off-Line Programming System. A proposed visual calibration scheme is based on position-based visual feedback. The visual calibration system is composed of a personal computer, an image processing board, a video monitor, and one camera. The calibration program firstly generates predicted images of objects in an assumed end-effector position. The process to generate predicted images consists of projection to screen-coordinates, visible range test, and construction of simple silhouette figures. Then, camera images acquired are compared with predicted ones for updating position and orientation data. Computation of error is very simple because the scheme is based on perspective projection, which can be also expanded to experimental results. Computation time can be extremely reduced because the proposed method does not require the precise calculation of tree-dimensional object data and image Jacobian.

  • PDF

Electroluminescence Properties of Simple Anthracene Derivatives Containing Phenyl or Naphthyl Group at 9,10-position for the Blue OLED

  • Kim, Si Hyun;Lee, Song Eun;Kim, Yong Kwan;Lee, Seung Hee
    • Journal of the Korean Applied Science and Technology
    • /
    • v.34 no.3
    • /
    • pp.562-567
    • /
    • 2017
  • The organic light-emitting diodes are fabricated with six anthracene derivatives containing simple substituents such as phenyl or naphthyl group. The device structure is as in the following: Indium tin oxide (ITO) (180 nm)/4,4-4,4',4"-tris[N-(1-naphthyl)-N-phenylamino]triphenylamine (2-TNATA) (30 nm)/4,4'-bis[N-(1-naphthyl)-N-phenyl-1-amino] biphenyl (NPB) (20 nm)/Emitting compound (30 nm)/2,2',2"-(1,3,5-Benzinetriyl)-tris (1-phenyl-1-H-benz-imidazole) TPBi (40 nm)/lithium quinolate (Liq) (2 nm)/Al (100 nm). In the emitting layer the anthracene derivatives are used without any dopant. All the six devices show blue emissions. Among the tested diodes, the one with 9-(2-naphthyl)-10-(p-tolyl) anthracene (2-NTA) exhibited luminous efficiency, power and external quantum efficiencies of 3.26 cd/A, 0.98 lm/A, 2.8 % at $20mA/cm^2$.