• Title/Summary/Keyword: simple procedure

Search Result 1,838, Processing Time 0.028 seconds

Adaptive Quantization of Difference Wavelet Image for Close-Range Low-Bitrate Transmission (근거리 저전송률 통신을 위한 차영상 웨이브릿 적응 양자화)

  • Jeong Won-Kyo;Leef Kyeong-Hwan;Lee Yong-Doo
    • Journal of Korea Multimedia Society
    • /
    • v.7 no.9
    • /
    • pp.1246-1254
    • /
    • 2004
  • This paper presents a image coding method that is well adaptive to close-range video transmission because of its low titrate and simple coding procedure. At first, it reduces temporal redundancies by performing image DPCM between previous frame and current frame, and makes wavelet transformed image of this difference image. Then, the coefficients are quantized selectively by using the coefficient values of base level and mid-frequency level because inter-level redundancies are widely exists in multi-resolution images. Finally quantized coefficients are made iron the function that implies the target bitrate, the average coefficient energy, and the value of the level. The proposed method shows the effective Performance in the experiments using the continuous motion images and transition images.

  • PDF

Ultrasound-guided Evacuation of Spontaneous Intracerebral Hemorrhage in Basal Ganglia

  • Park, Seong-Keun;Lee, Jung-Kil;Shin, Seung-Ryeol;Lee, Je-Hyuk
    • Journal of Korean Neurosurgical Society
    • /
    • v.37 no.3
    • /
    • pp.197-200
    • /
    • 2005
  • Objective: Ultrasound can be used in the treatment of large intracerebral hematoma. The authors present our experiences with Ultrasound-guided catheter placement for lysis and drainage of ganglionic hematoma, with emphasis on technical aspects. Methods: The authors applied real-time ultrasonography for the aspiration of intracerebral hematoma in 6cases. Ultrasound-guided aspiration via a burrhole was performed under local anesthesia. We selected a temporal entry point instead of the frequently used precoronal approach in ganglionic hematoma. A burrhole was made 4 to 6cm posterior from posterior border of frontal process of the zygomatic bone at the level of 4 to 5cm above the external auditory meatus. Results: In all patients, the catheter was placed accurately into the hematoma target. All patients were irrigated with urokinase once to three times a day. The catheter could be removed within two or three days. The mean hematoma volume was reduced from initially 32mL to 5mL in an average of two days. There were no intraoperative complications related to the use of real-time ultrasonography and no postoperative infections were noted. Conclusion: Ultrasound allows an easy and precise localization of the hematoma and the distance from the surface to the target can be calculated. Ultrasound-guided catheter placement for fibrinolysis and hematoma drainage is a simple and safe procedure.

The Rearch of the Young-su(迎隨) (영수보사(迎隨補瀉) 연구(硏究))

  • Im, Jin-Seok
    • Journal of Korean Medical classics
    • /
    • v.12 no.2
    • /
    • pp.282-292
    • /
    • 1999
  • In oriental medicine Acupuncture treatment is one of the most valuable therapy. Through the acupuncture humen have been healed many diseaes with his own natural therapic power, without medicine or surgery ect. But there have not formed a clear definition on the supplement & eradication(補瀉). I recognised the difference between the original meaning of Young-su(迎隨) mentioned in $\ll$Whang-Je-Nae-Kyung(黃帝內經)$\gg$ and Young-su-Bo-Sa(迎隨補瀉) that are recently used. The results were summerized as follow; 1. In the $\ll$Whang-Je-Nae-Gyung$\gg$, when they give medical teatment, they have totally used all methods of the supplement & eradication(補瀉). Therefore as now divided into respiration, speed, rotation and close-open supplement & eradication(補瀉) have many problomes. And Young-su(迎隨) did not mean the treatement of supplement and eradication which go with or against the flowing of channel energy(經氣). Young-su(迎隨) is not a simple technique of treatment, but is the totall principle of the supplement and eradication. 2. The direction of channel energy(經氣) connected with the O-su point (五輸穴) is from extremities to the trunk of body, therefore the direction of supplement is to the trunk of body and the direction of eradication is to extermities. 3. In the case of using the treatment which go with or against the flowing of channel energy(經氣), in oder to avoid the confusion of term, it must be defined another term. 4. It is necessary that we must define the procedure of supplement & eradication, and the objective indication that ascertain whether the doctor's purposes are really obtained.

  • PDF

LCL Type Series Resonant Converter with PWM Control Method (PWM 제어 방법을 이용한 LCL 직렬 공진 콘버터에 관한 연구)

  • 현동석;이요한;추병호;송인호;민경진
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.2 no.2
    • /
    • pp.19-28
    • /
    • 1997
  • A simple AC complex circuit analysis for LCL type series resonant converter with phase shift control is proposed. Based on these analyses, a set of characteristic curves which allows a optimal design procedure for this converter is shown, without increasing the volt-ampere rating of tank circuit. Especially, inverter output peak current can be minimized in both full load and partial load conditions. The presented design considerations can make the load range wide from full loads to light loads achieving turn-on with zero voltage switching (ZVS) operation. The simulation and experimental results show the effectiveness of the proposed design algorithms.

  • PDF

The Correction of Severe Inverted Nipple: Using Under Skin Dermal Flaps, Throughout Sutures and Purse-String Sutures. (피부 밑 진피피판법과 관통봉합 및 쌈지봉합을 이용한 심한 함몰유두 교정)

  • Yoon, Sang Yub;Kang, Min Go
    • Archives of Plastic Surgery
    • /
    • v.36 no.3
    • /
    • pp.322-326
    • /
    • 2009
  • Purpose: Severe type of inverted nipple (cannot be pulled out above the areola plane by manipulation, grade III) usually cannot be corrected by a relatively simple purse - string suture technique. Most patients want to avoid visible scars. To treat the severe case and avoid visible stigma, we introduce this invisible dermal flap method. Methods: This new surgical procedure makes bilateral incisions on the sidewall of nipple and dissections vertically to free the ducts from the contracted tissues. After dissection, the tunnel is formed. We insert "dermal flaps" into the tunnel underneath nipple base. Then through - and - through sutures are performed vertically (6 o'clock and 12 o'clock positions) and the purse - string suture is added with 4 - 0 nylon. Results: We had treated 35 primary inverted nipples (grade III) in 27 patients and 13 recurrent nipples in 7 cases. The results were excellent in 45 nipples (93.7%). All but 3 recurred cases was fully or very satisfied with the results. Conclusion: This technique is effective for the correction of severe inverted nipples and recurrent cases. We can avoid the visible scars on the areola surface.

A Simple and Efficient Subtractive Cloning Method

  • Min, Hyun-Jin;Park, Sang-Soo;Cho, Tae-Ju
    • BMB Reports
    • /
    • v.34 no.1
    • /
    • pp.59-65
    • /
    • 2001
  • In subtractive hybridization, target sequences in the tester are enriched by hybridizing with an excess amount of driver, followed by removing the tester hybridized with the driver. All of existing subtractive cloning methods are designed to remove the tester/driver hybrid. The removal of hybrid, however, is often unsatisfactory For various reasons. In this study we developed a subtractive enrichment protocol in which the tester/driver can be completely removed by selecting only the tester/tester after hybridization. In this protocol both the tester and driver DNAs are ligated with same linker DNAs and amplified by polymerase chain reaction (PCR). The tester DNA is then digested with two different enzymes and used in subsequent hybridization with an excess driver. After hybridization, the DNA is ligated with the adaptor that is only compatible with the tester/tester. Since only the tester/tester can have the new adaptor, no tester/driver can be amplified by PCR in this protocol. Unlike other methods, a 100% subtraction efficiency can be achieved even though the enzymatic treatments used in the enrichment procedure are incomplete. Furthermore, only the hybridized tester DNA can have the new adaptor and be amplified by PCR, resulting in 100% denaturation in effect. The efficacy of this novel method was verified with the model system in which a known amount of the target sequence is included.

  • PDF

Cell Balancing Method in Flyback Converter without Cell Selection Switch of Multi-Winding Transformer

  • Kim, Jin-Woong;Ha, Jung-Ik
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.2
    • /
    • pp.367-376
    • /
    • 2016
  • This paper presents a cell balancing method for a single switch flyback converter with a multi-winding transformer. The conventional method using a flyback converter with a multi-winding transformer is simple and easy to control, but the voltage of each secondary winding coil might be non-uniform because of the unequal effective turn-ratio. In particular, it is difficult to control the non-uniform effect using turn-ratios because secondary coil has a limited number of turns. The non-uniform secondary voltages disturb the cell balancing procedure and induce an unbalance in cell voltages. Individual cell control by adding a switch for each cell can reduce the undesirable effect. However, the circuit becomes bulky, resulting in additional loss. The proposed method here uses the conventional flyback converter with an adjustment made to the output filters of the cells, instead of the additional switch. The magnitude of voltage applied to a particular cell can be reduced or increased according to the adjusted filter and the selected switching frequency. An analysis of the conventional converter configuration and the filter design method reveals the possibility of adequate cell balancing control without any additional switch on the secondary side.

Neuro-Fuzzy Control of Interior Permanent Magnet Synchronous Motors: Stability Analysis and Implementation

  • Dang, Dong Quang;Vu, Nga Thi-Thuy;Choi, Han Ho;Jung, Jin-Woo
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.6
    • /
    • pp.1439-1450
    • /
    • 2013
  • This paper investigates a robust neuro-fuzzy control (NFC) method which can accurately follow the speed reference of an interior permanent magnet synchronous motor (IPMSM) in the existence of nonlinearities and system uncertainties. A neuro-fuzzy control term is proposed to estimate these nonlinear and uncertain factors, therefore, this difficulty is completely solved. To make the global stability analysis simple and systematic, the time derivative of the quadratic Lyapunov function is selected as the cost function to be minimized. Moreover, the design procedure of the online self-tuning algorithm is comparatively simplified to reduce a computational burden of the NFC. Next, a rotor angular acceleration is obtained through the disturbance observer. The proposed observer-based NFC strategy can achieve better control performance (i.e., less steady-state error, less sensitivity) than the feedback linearization control method even when there exist some uncertainties in the electrical and mechanical parameters. Finally, the validity of the proposed neuro-fuzzy speed controller is confirmed through simulation and experimental studies on a prototype IPMSM drive system with a TMS320F28335 DSP.

Standardization of Inspection and Imaging of Facial Color, and Design of Gloss-detecting Method (면색정보취득 制御條件 표준화 및 윤택측정방안 설계)

  • Chi, Gyoo Yong;Kim, Jong Won
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.29 no.4
    • /
    • pp.289-294
    • /
    • 2015
  • In order to make digital processing of facial color, standardization methods of photographing and observational requirements and gloss-detecting are done through preceding papers and actual experiences. Examiner's observational informations should be contained with original and temporary color, normalcy and deviation range and gloss. And these are interrelated with time, interior and exterior temperature, emotional state, so should be recorded too. Picturing procedure should be controlled in simple and practical but objective way. Just water cleansing, 15 to 20 minute resting, prohibiton of moisturizing of examinee are common for examiner. Temperature and moisture, width, light source requirement, brightness, polarizing filter of parlor and camera-to-object distance, posture of examinee are should be recorded. In addition, pre and post-revision of color and manifestation of color space after taking images are needed coping with construction of diagnostic database.

Accuracy Evaluation of Alternative Concept Joint Models (결합부위 단순모델의 정확성 평가 방법의 개발)

  • Lee, Kwang Ju
    • Journal of Korean Society of Steel Construction
    • /
    • v.11 no.1 s.38
    • /
    • pp.23-31
    • /
    • 1999
  • The concept models are used for the analysis of joints because they are simple to use and accurate. The modeling parameters of concept models are estimated using the results of experiments performed on the joints. The concept joint models accurately describe the behavior of joints under the loads which are used in the experiments for the estimation of parameters. However, they may not be accurate under the loads which are not used in the experiments. The accuracy can be dependent on the loads which are used in the evaluation of accuracy. In this study, antioptimization is presented to find the worst possible loads, under which the accuracy of concept joint models can be evaluated. The procedure was applied to the accuracy evaluation of concept joint models in an isolated 3-D joint and 2-D joints of a vehicle structure.

  • PDF