• Title/Summary/Keyword: simple measurement method

Search Result 941, Processing Time 0.03 seconds

An Experimental Study on the Evaluation of Unit-Water Content Acoording to Concrete Aggregate Variables through FDR Sensor (FDR 센서를 통한 콘크리트 골재 변수에 따른 단위수량 평가에 관한 실험적 연구)

  • Youn, Ji-Won;Yu, Seung-Hwan;Yang, Hyun-Min;Yoon, Jong-Wan;Park, Tae-Joon;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.11a
    • /
    • pp.70-71
    • /
    • 2021
  • The unit quantity that affects the workability, shrinkage cracking, and durability of concrete is an important factor. Methods for measuring the unit quantity include a high frequency heating method, a capacitance method, a unit volume mass method, and a simple method. However, these methods have the disadvantage of poor measurement method, time required, and precision. To solve this problem, a relatively simple and fast measurement method was adopted to compensate for the shortcomings through a Frequency Domain Reflection (FDR) sensor, and the unit quantity was used. In addition, the measurement data was analyzed by deep learning to evaluate the unit quantity of concrete.

  • PDF

Static measurement of yield stress using a cylindrical penetrometer

  • Uhlherr, P.H.T.;Guo, J.;Fang, T.N.;Tiu, C.
    • Korea-Australia Rheology Journal
    • /
    • v.14 no.1
    • /
    • pp.17-23
    • /
    • 2002
  • A novel and simple method using a cylindrical penetrometer is being developed for the measurement of yield stress. The principle of this technique is based on the measurement of the static equilibrium of a falling penetrometer in a yield stress fluid. The yield stress is simply determined by a balance of forces acting on the penetrometer. The yield stress of Carbopol gels and $TiO_2$ suspensions has been measured using this method. The results are in reasonable agreement with the values from conventional methods. The effects of the dimensions and weight of the penetrometer have been examined. The long-term behaviour was also observed. No measurable creep was seen and equilibrium was found to be very quickly established. The cylindrical penetrometer technique promises to be a simple, quick and reliable static method for the measurement of yield stress.

Measurement Method of Posture and Movement for the Aged Person using an Accelerometer

  • Sugimoto, Takao;Mori, Kentarou
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.87-91
    • /
    • 2004
  • High aged society is rapidly progressing in Japan. The rate of aged person more than 65 years old in the population are estimated 25 % in 2017 and rate of younger population will be decreased at same time. As a result, it is estimated that the human resources that is looking after or supporting for the aged person will be drained in Japan. In the other hand, the society has to provide high quality of life in order to be improved living environment for aged person. To decrease the share of nursing and caring for the aged person, it is required that new supporting systems for aged person have to build up as soon as possible. But it is required that various kind of measurement for posture and movement in activities with a simple and single detector for the aged person. The measurement instrument has to be lightweight and simple structure. The results give us a simple measurement method are classified that the posture of sitting down, lying down in stationary statuses and walking, running and going to up and down on the stairs in moving statuses. The detected data will plane to transmit to wireless mobile system to the host computer.

  • PDF

Analysis of Repeated Measurement Problem in SP data (SP 데이터의 Repeated Measurement Problem 분석)

  • CHO, Hye-Jin
    • Journal of Korean Society of Transportation
    • /
    • v.20 no.1
    • /
    • pp.111-119
    • /
    • 2002
  • One of the advantages of SP methods is the possibility of getting a number of responses from each respondent. However, when the repeated observations from each respondent are analysed by applying the simple modeling method, a potential problem is created because of upbiased significance due to the repeated observation from each respondent. This study uses a variety of approaches to explore this issue and to test the robustness of the simple model estimates. Among several different approaches, the Jackknife method and Kocurs method were applied. The Jackknife method was implemented using a program JACKKNIFE. The model estimate results of Jackknife method and Kocurs method were compared with those of the uncorrected estimates in order to test whether there was repeated measurement problem or not and the extent to which this problem affected the model estimates. The standard errors between the uncorrected model estimates and Jackknife estimates were also compared. The results reveals that the t-ratios of Kocurs are much lower than those of the uncorrected method and Jackknife estimates, indicating that Kocurs method underestimates the significance of the coefficients. Jackknife method produced the almost same coefficients as those of the uncorrected model but the lower t-ratios. These results indicate that the coefficients of the uncorrected method are accurate but that their significance are somewhat overestimated. In this study. 1 concluded that the repeated measurement Problem did exist in our data, but that it did not affect the model estimation results significantly. It is recommended that such a test should become a standard procedure. If it turns out that the analysis based on the simple uncorrected method are influenced by the repeated measurement problem. it should be corrected.

Development of Quality of Life Measurement for Cancer Patients (암환자의 삶의 질 도구개발)

  • Tae, Young Sook;Kang, Eun-Sil;Lee, Myung Hwa;Park, Geum Ja
    • Korean Journal of Adult Nursing
    • /
    • v.12 no.4
    • /
    • pp.741-757
    • /
    • 2000
  • This study was undertaken to develop an instrument to be used for measuring the concept of quality of life of Korean patients with cancer multidimensionary and correctly. It can contribute in holistic nursing care for Korean cancer patients and also provide and validate basic data to help oncology nurses measure the outcome of nursing intervention correctly. To develop this instrument, the researchers first estabilished a conceptual framework based on the results of qualitative data analysis and indepth interview method Development of the scale was conducted using a method in which 31 items were assessed by subjects' self report using linear analogue scales. The subjects were 79 D.M. patients, 103 patients with acute illness, and 91 cancer patients residing in Busan, Korea. Data were collected during the period from July, 24 to August 14, 2000. This instrument consisted of 31 items with a self report scale. This instrument covered 4 dimensions of cancer patients : 1) physical wellbeing 2) psychological wellbeing 3) social wellbeing and 4)spiritual wellbeing. Each item had a possible score of 10. The reliability of the scale was tested with Cronbach's alpha. Validity was evaluated by examining the relationships of this scale, Youn's Quality of Life Questionnare scores and the Simple Quality of Life scale. Two separate runs of multiple regression were used to predict scores on the Simple Quality of Life measurement. Further validation was obtained by examining the correlation between the instrument subscores and Youn's Quality of Life measurement subscore for convergence of this scale. Examination of the discriminant. power of the instrument was done using ANOVA test. The results are summarized as follows: 1. The reliability of the instrument for the quality of life was 0.8321(Cronbach's alpha.), physical wellbeing dimension 0.6343, psychological wellbeing dimension 0.6501, spiritual wellbeing dimension 0.5883. 2. This instrument had a high correlation with Youn's Quality of Life measurement(r= 0.636) in cancer patients, whereas it had a low correlation with Simple Quality of Life measurement(r=0.455) in cancer patients. In the D.M. patients, the instrument correlated with both the Youn's Quality of Life measurement and Simple Quality of life measurement(r=0.313, r= 0.407) and in the acute stage patients, the instrument had no correlation. 3. Multiple regression of individual items on the Simple Quality of Life scores accounted for 56.8% of the variance in the Simple Quality of Life measurement, whereas, Youn's Quality of Life measurement scores accounts for 31.7%. 4. The correlations collected from the three group had the same patterns of variations but especially the instrument developed in this study had higher disciminant power than that of Youn's Quality of Life Measurement.

  • PDF

A Study on the Insulation Performance of Impact Sound Level by Striking Location of Floor Slab (바닥 슬라브의 가진 위치에 따른 차음성능에 관한 연구)

  • Song, Pil-Dong;Park, Myung-Kil;Ham, Jin-Sik
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2003.11a
    • /
    • pp.73-76
    • /
    • 2003
  • This paper is contents about method to measure interception performance of shock noise of floor slab of apartment house to be simple. In the case of interception performance of light floor impact sound level, according to measurement method, grade of sound insulation performance showed greatly differently. But, in the case of interception performance of heavy floor impact sound level, it was similar result in all measurement method. Therefore, use of simple method of measurement was examined by possible fact in case of interception performance of heavy floor impact sound level.

  • PDF

3D Particle Image Detection by Using Color Encoded Illumination System

  • Kawahashi M.;Hirahara H.
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2001.12a
    • /
    • pp.100-107
    • /
    • 2001
  • A simple new technique of particle depth position measurement, which can be applied for three-dimensional velocity measurement of fluid flows, is proposed. Two color illumination system that intensity is encoded as a function of z-coordinate is introduced. A calibration procedure is described and a profile of small sphere is detected by using the present method as preliminary test. Then, this method is applied to three-dimensional velocity field measurement of simple flow fields seeded with tracer particles. The motion of the particles is recorded by color 3CCD camera. The particle position in the image plane is read directly from the recorded image and the depth of each particle is measured by calculation of the intensity ratio of encoded two color illumination. Therefore three-dimensional velocity components are reconstructed. Although the result includes to some extent error, the feasibility of the present technique for three-dimensional velocity measurement was confirmed.

  • PDF

On-site water level measurement method based on wavelength division multiplexing for harsh environments in nuclear power plants

  • Lee, Hoon-Keun;Choo, Jaeyul;Shin, Gangsig;Kim, Sung-Man
    • Nuclear Engineering and Technology
    • /
    • v.52 no.12
    • /
    • pp.2847-2851
    • /
    • 2020
  • A simple water level measurement method based on wavelength division multiplexing (WDM) is proposed and demonstrated. The measurement principle is based on the change of Fresnel reflection occurring at the end facet of the optical fiber tip (OFT). To increase the spatial resolution of water level sensing, a broadband light source (BLS) and an arrayed waveguide grating (AWG) are employed. The OFTs are multiplexed with the dedicated wavelength channels of AWG. By measuring all of the reflection powers reflected at the OFTs with a proposed on-site reflectometer, the water level can be monitored continuously for a fast emergency response. Moreover, it can be implemented easily with the commercially available optical components and devices with the simple configuration.

Application of rotating polarizer method for small cellgap measurement (회전평광법을 이용한 낮은 셀갭 측정)

  • 김창선;이기동;윤태훈;김재창
    • Korean Journal of Optics and Photonics
    • /
    • v.11 no.3
    • /
    • pp.158-162
    • /
    • 2000
  • Measurement of low cell gap and retardation by using a rotating polarizer method was proposed. For more precise calculation and measurement, we applied a simple numerical calculation and a retardation film that has large retardation value of 1 ~m to measurement system. From experiments, we proved that cell gap and retardation could be measured even though the values of those are so small. small.

  • PDF

A Study on a Simple Efficiency Estimation of Small DC Motor (소형 직류모터의 간략한 효율예측에 관한 연구)

  • Won, Sung Hong
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.63 no.3
    • /
    • pp.143-148
    • /
    • 2014
  • This paper proposes a novel efficiency measurement method without dynamometer. In case of small motor, the measurement of efficiency is not easy because the percentage of mechanical loss is comparably huge and the mechanical loss is not easy to be measured. In this paper, the authors proposes a method which can measure the efficiency with two test motors. This method can be useful to engineers who study small electrical motors.