• 제목/요약/키워드: silver electrode

검색결과 247건 처리시간 0.025초

미세노즐 토출에 적용 가능한 은 전극의 조성에 대한 연구 (A Study on the Composition of Silver Paste for Micro Nozzle Dispensing Method)

  • 김도형;신동욱;류성수;장효식;김형준
    • 신재생에너지
    • /
    • 제8권1호
    • /
    • pp.18-23
    • /
    • 2012
  • The screen printing has been widely used to form silver electrodes in solar cell device due to their simplicity of process. However, the wavy and irregular surface which is believed to be originated from a screen mask mesh and thixotropic characteristics of paste on screen printing process is well-known to give a negative effect on solar cell efficiency. The dispensing method that the silver paste is extruded through micro nozzle under a moderate pressure and coated on substrate can form the silver electrode without any wavy surface. In this study, we optimize the composition of silver paste and develop paste blending condition based on the thixotropic behavior of paste. The optimized paste shows a large thixotropic loop area which is related to an aspect ratio of electrode line and has the viscosity of 40 $Pa{\cdot}s$ at 40 s-1. The electrode line we finally obtainis 67.2 ${\mu}m$ in width and has an aspect ratio of 0.277.

우레탄 필름에 인쇄된 신축 가능한 전극 패턴의 특성 (Properties of Stretchable Electrode Pattern Printed on Urethane Film)

  • 남수용;권보석;남현진;남기우;박효준
    • 동력기계공학회지
    • /
    • 제22권1호
    • /
    • pp.64-71
    • /
    • 2018
  • Currently, functional patterns are formed by screen printing on stretchable films, and they are applied to wearable and stretchable devices. In this study, three types of silver paste were prepared using three polyester binders with different Tg and molecular weights in order to impart elasticity to the conductive pattern itself. Rheological properties and DSC measurements were performed for each silver paste. Then, each silver paste was screen printing and cured by an IR dryer to evaluate adhesive strength, pencil hardness, resistance and surface shape change according to strain. As a result, it was found that the silver paste using a binder with a low Tg and a high molecular weight has the smallest resistance change depending on the strain. Namely, it was found that it is most preferable to use a binder with a low Tg and a high molecular weight as the stretchable electrode.

Mercapto 화합물에 의한 은의 정량 (제1보) 2,5-Dimercapto-1,3,4-Thiadiazol에 의한 은의 전류 적정 (Determination of Silver with Mercaptans (I). Amperometric Titration of Silver with 2,5-Dimercapto-1,3,4-Thiadiazole)

  • 하영구;최규원
    • 대한화학회지
    • /
    • 제17권2호
    • /
    • pp.126-129
    • /
    • 1973
  • 회전백금전극을 지시전극으로하고 수은-요오드화수은(II)을 기준전극으로하여 암모니아수용액에서 2.5-dimercapto-1,3,4-thiadiazole에 의한 은의 전류적정법을 연구하였다. 암모니아수용액에서 EDTA를 은폐제로 사용하여 여러 가지 이온들의 존재 하에 미량의 은을 직접 적정할 수가 있었으며 백금과 금 이온만이 방해하였다. 이 방법으로 미량의 은을 상대 오차 ${\pm}3{\%}$이내 정량할 수 있다.

  • PDF

Fabrication of Hemoglobin/Silver Nanoparticle Heterolayer for Electrochemical Signal-enhanced Bioelectronic Application

  • Lee, Taek;Yoon, Jinho;Choi, Jeong-Woo
    • Korean Chemical Engineering Research
    • /
    • 제55권4호
    • /
    • pp.556-560
    • /
    • 2017
  • A hemoglobin/silver nanoparticle heterolayer was fabricated for bioelectronic device with electrochemical signal-enhancement effect. As a device element, a hemoglobin, the metalloprotein, contained the heme group that showed the redox property was introduced for charge storage element. For electron transfer facilitation, a silver nanoparticle was introduced for electrochemical signal facilitation, the hemoglobin was immobilized onto Au substrate using chemical linker 6-mercaptohexanoic acid (6-MHA). Then, the silver nanoparticle was immobilized onto fabricated hemoglobin/6-MHA heterolayers by layer-by-layer (LbL) method. The surface morphology and surface roughness of fabricated heterolayer were investigated by atomic force microscopy (AFM). The redox property of hemoglobin/silver nanoparticle heterolayer was investigated by a cyclic voltammetry (CV) experiment for obtaining an oxidation potential and reduction potential. Moreover, for the assessing charge storage function, a chronoamperometry (CA) experiment was conducted to hemoglobin/silver nanoparticle-modified heterolayer electrode using oxidation and reduction potentials, respectively. Based on the results, the fabricated hemoglobin/silver nanoparticle heterolayer showed that an increased charge storage effect compared to hemoglobin monolayer-modified electrode.

유리기판 위에 Ag 후막의 마이크로웨이브 소결 (Microwave Sintering of Silver Thick Film on Glass Substrate)

  • 황성진;;;김형순
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 하계학술대회 논문집
    • /
    • pp.22-22
    • /
    • 2009
  • The silver thick film has been used in many industries such as display, chip, solar cell, automobile, and decoration with conventional heating. The silver thick film is fired with optimal time and temperature. However, decreasing the fabrication time is required due to high production power. Furthermore, there is a problem that silver in electrode is diffused throughout any substrates. For inhibiting the Ag diffusion and long fabrication time we considered a microwave heating. We investigated firing of silver thick film with conventional and microwave heating. The temperature of substrate was measured by thermal paper and the temperature of substrate was under $100\;^{\circ}C$ The shrinkage of electrode was measured with optical microscopy and optical profilometry. The shrinkage of electrode heat treated with microwave for 5min was similar to the that fired by the conventional heating for several hours. After firing by two types of heating, the diffusion of silver was determined using a optical microscope. The microstructure of sintered silver thick film was observed by SEM. Based on our results, the microwave heating should be a candidate heating source for the fabrication electronic devices in terms of saving the tact time and preventing the contamination of substrate.

  • PDF

Reference Electrode for Monitoring Cathodic Protection Potential

  • Panossian, Z.;Abud, S.E.
    • Corrosion Science and Technology
    • /
    • 제16권5호
    • /
    • pp.227-234
    • /
    • 2017
  • Reference electrodes are generally implemented for the purpose of monitoring the cathodic protection potentials of buried or immersed metallic structures. In the market, many types of reference electrodes are available for this purpose, such as saturated calomel, silver/silver chloride and copper/copper sulfate. These electrodes contain a porous ceramic junction plate situated in the cylindrical body bottom to permit ionic flux between the internal electrolyte (of the reference electrode) and the external electrolyte. In this work, the copper/copper sulfate reference electrode was modified by replacing the porous ceramic junction plate for a metallic platinum wire. The main purpose of this modification was to avoid the ion copper transport from coming from the inner reference electrode solution into the surrounding electrolyte, and to mitigate the copper plating on the coupon surfaces. Lab tests were performed in order to compare the performance of the two mentioned reference electrodes. We verified that the experimental errors associated with the measurements conducted with developed reference electrode would be negligible, as the platinum surface area exposed to the surrounding electrolyte and/or to the reference electrolyte are maintained as small as possible.

A New Cone Shaped Asymmetrically Substituted Calix[4]arene as an ExcellentIonophore in Construction of Ag(I) ion-Selective Membrane Electrode

  • Ganjali, Mohammad Reza;Babaei, Leila Hajiagha;Taghvaei-Ganjali, Saeed;Modjallal, Atoosa;Sahmsipur, Mojtaba;Hosseini, Morteza;Javanbakht, Mehran
    • Bulletin of the Korean Chemical Society
    • /
    • 제25권2호
    • /
    • pp.177-181
    • /
    • 2004
  • A PVC membrane electrode for silver ion based on a new cone shaped calix[4]arene (CASCA) as membrane carrier was prepared. The electrode exhibits a Nernstian response for $Ag^+$ over a wide concentration range ($1.0{\times}10^{-1}-8.0{\times}10^{-6}$M) with a slope of 58.2 {\pm}$ 0.5 mV per decade. The limit of detection of the sensor is $5.0{\times}10^{-6}$M. The sensor has a very fast response time (~5 s) in the concentration range of ${\leq}=1.0{\times}10^{-3}$ M, and a useful working pH range of 4.0-9.5. The proposed sensor displays excellent discriminating ability toward $Ag^+$ ion with respect to common alkali, alkaline earth, transition and heavy metal ions. It was used as an indicator electrode in potentiometric titration of $Ag^+$ with EDTA and in direct determination of silver ion in wastewater of silver electroplating.

초음속 유동에서 코로나 방전을 이용한 금속 나노 입자의 생성 (Metallic Nano Particle Generation by Supersonic Nozzle with Corona Discharge)

  • 정재희;박형호;김상수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.1510-1515
    • /
    • 2004
  • The effects of additive ions on the generation of metallic nanoparticles were evaluated using a corona induced supersonic nozzle. Applying the corona discharge to the nanoparticle generator, a tungsten needle and the supersonic nozzle are used as an anode electrode and a cathode electrode respectively. The corona ions act as nuclei for the silver vapor condensation. The ion density was controlled precisely as varying the applied voltage between electrode and nozzle. The mean diameter of the silver particle decreases as the ion density increases. However, the number concentration of the silver particle tended to increase with the ion density. The size distribution is more uniform as the ion density increases.

  • PDF

무정제 단일벽 탄소나노튜브와 은나노와이어가 적층으로 코팅된 투명전도성 고분자 필름의 전기 전도성, 광학 투과도 및 산화안정성 (Electrical Conductivity, Optical Transmittance, and Oxidation Stability of Transparent Conductive Polymer Film Coated With Layered Pristine Single-walled Carbon Nanotube and Silver Nanowire)

  • 이영실
    • Korean Chemical Engineering Research
    • /
    • 제61권3호
    • /
    • pp.456-462
    • /
    • 2023
  • 탄소나토튜브를 투명 전극에 활용하기 위한 필수요소인 정제과정없이 무정제 단일벽 탄소나노튜브(single-walled carbon nanotube, SWCNT)와 은나노와이어(silver nanowire) 분산액을 제조하여 폴리에틸렌 테레프탈레이트(polyethylene terephthalate, PET) 필름에 바 코팅을 이용하여 전기전도성 투명전극을 제조하였다. PET 기판 위에 SWCNT 및 은 나노와이어를 각각 포함하는 코팅층을 상호 교차시켜 적층함으로서 은나노와이어의 전기 전도도와 투과도를 극대화시키고 헤이즈 (haze)가 증가되는 단점을 극복하기 위해 SWCNT를 도입하였고, 무정제 SWCNT내에 존재하는 금속 촉매의 산화에 의해서 항온항습 테스트 후 저항이 급격하게 증가하는 문제를 은 나노와이어가 전기적 네트워크 형성에 기여하여 산화에 대한 안정성을 확보할 수 있었다. SWCNT함량이 0.025 wt% 인 분산액을 PET 기판에 먼저 코팅하고 그 위에 은 나노와이어의 함량이 0.05 wt%인 분산액을 코팅한 투명전극의 시트 저항은 47 Ω/□, 투과도는 96.72%, 헤이즈는 1.93% 로 전기적 광학적 특성이 우수하게 나왔고, 산화 안정성 평가를 위한 항온 항습 실험 후 시트 저항의 변화율이 6.4% 로 적게 나타나서 장기적 사용에 적합하다는 것을 알 수 있었다. 무정제 SWCNT 사용함으로 저비용, 친환경 하이브리드 투명전극을 상업적으로 활용 가능한 수준의 제품이 개발되었다.

AgNWs/Ga-doped ZnO 복합전극 적용 CdSe양자점 기반 투명발광소자 (CdSe Quantum Dot based Transparent Light-emitting Device using Silver Nanowire/Ga-doped ZnO Composite Electrode)

  • 박재홍;김효준;강현우;김종수;정용석
    • 반도체디스플레이기술학회지
    • /
    • 제19권4호
    • /
    • pp.6-10
    • /
    • 2020
  • The silver nanowires (AgNWs) were synthesized by the conventional polyol process, which revealed 25 ㎛ and 30 nm of average length and diameter, respectively. The synthesized AgNWs were applied to the CdSe/CdZnS quantum dot (QD) based transparent light-emitting device (LED). The device using a randomly networked AgNWs electrode had some problems such as the high threshold voltage (for operating the device) due to the random pores from the networked AgNWs. As a method of improvement, a composite electrode was formed by overlaying the ZnO:Ga on the AgNWs network. The device used the composite electrode revealed a low threshold voltage (4.4 Vth) and high current density compared to the AgNWs only electrode device. The brightness and current density of the device using composite electrode were 55.57 cd/㎡ and 41.54 mA/㎠ at the operating voltage of 12.8 V, respectively, while the brightness and current density of the device using (single) AgNWs only were 1.71 cd/㎡ and 2.05 mA/㎠ at the same operating voltage. The transmittance of the device revealed 65 % in a range of visible light. Besides the reliability of the devices was confirmed that the device using the composite electrode revealed 2 times longer lifetime than that of the AgNWs only electrode device.