• Title/Summary/Keyword: silver chloride

Search Result 89, Processing Time 0.021 seconds

Efficient Synthesis of β-Acetamido Ketones by Silver(I) Triflate-Catalyzed Multicomponent Reactions

  • Pandit, Rameshwar Prasad;Lee, Yong Rok
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.11
    • /
    • pp.3559-3564
    • /
    • 2012
  • An efficient one-pot synthesis of ${\beta}$-acetamido ketones was accomplished by AgOTf-catalyzed multicomponent reactions of substituted acetophenones with aromatic aldehydes and acid chloride in acetonitrile in high yields. The methods offer several significant advantages of easy handling, mild reaction conditions, and use of effective and non-toxic catalyst.

Study on Micro Dried Bio-potential Electrodes Using Conductive Epoxy on Textile Fabrics (전도성 에폭시를 이용한 직물 위에 구현된 건식 생체전위 전극의 연구)

  • Cha, Doo-Yeol;Jung, Jung-Mo;Kim, Deok-Su;Yang, Hee-Jun;Choi, Kyo-Sang;Choi, Jong-Myong;Chang, Sung-Pil
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.26 no.5
    • /
    • pp.367-372
    • /
    • 2013
  • In this paper, micro dried bio-potential electrodes are demonstrated for sEMG (surface ElectroMyoGraphic) signal measurement using conductive epoxy on the textile fabric. Micro dried bio-potential electrodes on the textile fabric substrate have several advantages over the conventional wet/dry electrodes such as good feeling of wearing, possibility of extended-wearing due to the good ventilation. Also these electrodes on the textile fabric can easily apply to the curved skin surface. These electrodes are fabricated by the screen-printing process with the size of $1mm{\times}10mm$ and the resultant resistance of these electrodes have the average value of $0.4{\Omega}$. The conventional silver chloride electrode shows the average value of $0.3{\Omega}$. However, the electrode on the textile fabric are able to measure the sEMG signal without feeling of difference and this electrode shows the lower resistance of $1.03{\Omega}$ than conventional silver chloride electrode with $2.8{\Omega}$ in the condition of the very sharp curve surface (the radius of curvature is 40 mm).

Applicability of Colormetric Method for Estimation of Chloride Penetration in Concrete Structures (콘크리트 구조물의 염화물 침투 특성 파악을 위한 변색법의 적용성)

  • Yang Eun-Ik;Kim Myung-Yu;Leem Young-Moon;Park Hae-Geun
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.6 s.90
    • /
    • pp.931-938
    • /
    • 2005
  • When concrete structures are exposed under marine condition for a long time, the steel in concrete is corroded due to the ingression of chlorides in the seawater. Because the damages of corrosion resulting from the chloride ion are very serious, many researches have been performed. Silver nitrate colormetric method that can measure easily penetration depth of chloride ion has been executed, recent)y. However, characteristics of silver nitrate colormetric method were not fully examined. Therefore, the objective of this paper Is to study the applicability of colormetric method. For the purpose of this, effect factors and reaction mechanism of colormetric method were investigated, and the colormetric method is applied for marine concrete structures. According to the results of silver nitrate colored method, two reactions such as white reaction of AgCl and brown reaction of AgOH were shown when $AgNO_3$ was sprayed in splited section. And velocity constant ratio(K) of two reactions appeared that white reaction, AgCl reacts with the fast speed by 3240. When the colormetric method was applied in concrete, it is reasonable that $AgNO_3$ solution more than 0.05N concentration was sprayed. It is confirmed that the colormetric method is useful tool for estimating the chloride of concrete structures in situ. The average chloride amount of colored parts indicates $0.9kg/m^3$ per concrete unit weight.

Study on PVC Mixed Silver Iodide Membrane Electrode (PVC 를 섞은 요오드화은 막전극에 관한 연구)

  • Kwon Young-Soon;Kim Jung-Hee;Park Kee-Chae
    • Journal of the Korean Chemical Society
    • /
    • v.20 no.6
    • /
    • pp.486-493
    • /
    • 1976
  • The PVC mixed silver iodide pellet was prepared by means of the Infrared Pellet presser and the pellet was used as an indicating membrane electrode, to measure the potentials for various silver ion activities, ranging from $10^{-1}$ to $10^{-6}$ M. The potential responses to silver ion activities were linear and the slope was much close to Nernstian relation as compared with that of the pure silver iodide pellet membrane electrode and the PVC coated silver iodide pellet membrane electrode. The mechanical property and chemical durability of this electrode were found much better than the others. This electrode did not show significant response to the other except silver ion, but had good response to halide ions, i.e., iodide, chloride, bromide and cyanide ions, in the concentration range $10^{-1}$ to $10^{-6}$ M. This electrode could be used as an indicating electrode in potentiometric titrations of single halide ion and also halide mixture with standard solution of silver nitrate.

  • PDF

Reference Electrode at Molten Salt: A Comparative Analysis of Electroceramic Membranes

  • Yoon, Seokjoo;Kang, Dokyu;Sohn, Sungjune;Park, Jaeyeong;Lee, Minho;Choi, Sungyeol
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.18 no.2
    • /
    • pp.143-155
    • /
    • 2020
  • A reference electrode is important for controlling electrochemical reactions. Evaluating properties such as the reduction potential of the elements is necessary to optimize the electrochemical processes in pyroprocessing, especially in a multicomponent environment. In molten chloride systems, which are widely used in pyroprocessing, a reference electrode is made by enclosing the silver wire and molten salt solution containing silver chloride into the membranes. However, owing to the high temperature of the molten salt, the choice of the membrane for the reference electrode is limited. In this study, three types of electroceramic, mullite, Pyrex, and quartz, were compared as reference electrode membranes. They are widely used in molten salt electrochemical processes. The potential measurements between the two reference electrode systems showed that the mullite membrane has potential deviations of approximately 50 mV or less at temperatures higher than 650℃, Pyrex at temperatures lower than 500℃, and quartz at temperatures higher than 800℃. Cyclic voltammograms with different membranes showed a significant potential shift when different membranes were utilized. This research demonstrated the uncertainties of potential measurement by a single membrane and the potential shift that occurs because of the use of different membranes.

Impregnated Active Carbon-Shelf Life Studies and Its Evaluation Against Cyanogen Chloride with and without Canister

  • Singh, Beer;Saxena, Amit;Srivastava, Avanish Kumar;Dubey, Devendra Kumar;Gupta, Arvind Kumar
    • Carbon letters
    • /
    • v.8 no.4
    • /
    • pp.280-284
    • /
    • 2007
  • Samples of active carbon of $1150\;m^2/g$ surface area were impregnated with ammoniacal salts of copper, chromium and silver, with and without triethylenediamine. The samples of impregnated carbon were aged at $50^{\circ}C$, with and without 90% RH (relative humidity), for a little more than one year and chemically evaluated periodically. Initially copper (II) and chromium (VI) reduced very fast in the samples in humid atmosphere to the extent of 30% and 60% respectively in four months. These values were found to be unaffected by the presence of triethylenediamine (TEDA) indicating that the chemical did not retard the reduction process of chromium (VI) and copper (II). However, in the absence of humidity the reduction of the impregnants was significantly less (10-12%, w/w) in four months. It was quite evident; therefore, that the moisture was mainly responsible for the reduction of chromium (VI) and copper (II) species in impregnated carbons. The prolonged ageing of the samples with and without triethylenediamme after four months with and without humid atmosphere showed that the extent of reduction of chromium (VI) was very low, i.e. 5-10% and of copper (II) was 2-25%. Silver is not reduced due to carbon, as it remained unchanged in concentration on storage. The impregnated carbon samples (100 g) without triethylenediamine, which were aged at room temperature for 5 years in absence of humidity and unaged when evaluated against cyanogen chloride (CNCl) at a concentration of 4 mg/L and airflow rate of 30 lpm showed a high degree of protection (80- 110 minutes).

Reference Electrode for Monitoring Cathodic Protection Potential

  • Panossian, Z.;Abud, S.E.
    • Corrosion Science and Technology
    • /
    • v.16 no.5
    • /
    • pp.227-234
    • /
    • 2017
  • Reference electrodes are generally implemented for the purpose of monitoring the cathodic protection potentials of buried or immersed metallic structures. In the market, many types of reference electrodes are available for this purpose, such as saturated calomel, silver/silver chloride and copper/copper sulfate. These electrodes contain a porous ceramic junction plate situated in the cylindrical body bottom to permit ionic flux between the internal electrolyte (of the reference electrode) and the external electrolyte. In this work, the copper/copper sulfate reference electrode was modified by replacing the porous ceramic junction plate for a metallic platinum wire. The main purpose of this modification was to avoid the ion copper transport from coming from the inner reference electrode solution into the surrounding electrolyte, and to mitigate the copper plating on the coupon surfaces. Lab tests were performed in order to compare the performance of the two mentioned reference electrodes. We verified that the experimental errors associated with the measurements conducted with developed reference electrode would be negligible, as the platinum surface area exposed to the surrounding electrolyte and/or to the reference electrolyte are maintained as small as possible.

Surface-enhanced Raman Spectroscopy of Benzimidazolic Fungicides: Benzimidazole and Thiabendazole

  • Kim, Mak-Soon;Kim, Min-Kyung;Lee, Chul-Jae;Jung, Young-Mee;Lee, Mu-Sang
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.12
    • /
    • pp.2930-2934
    • /
    • 2009
  • Surface-enhanced Raman Scattering (SERS) spectroscopy is applied to the study of the adsorption of benzoimidazolic fungicides benzimidazole (BIZ) and thiabendazole (TBZ) on silver mirrors. The influence of pH on the adsorption mechanism was investigated. In case of BIZ, two different adsorption mechanisms are deduced depending on the experimental conditions: via the $\pi$ electrons of the ring in neutral conditions and through an ionic pairing of protonated nitrogen atom with the chloride adsorbed on the metal surface. The SERS spectra of TBZ revealed that most molecules were adsorbed on silver surface by the ${\pi}$ electrons in neutral and acidic conditions but in acid conditions, some molecules were adsorbed via the sulfur and nitrogen atoms tilted slightly to the surface.

Surface Enhanced Raman Spectroscopic Studies on Zn(Ⅱ) and Mn(Ⅲ) Tetrakis (4-N-Methyl Pyridyl) Porphyrins

  • Song, Ok-Keun;Yoon, Min-Joong;Kim, Dong-Ho
    • Bulletin of the Korean Chemical Society
    • /
    • v.11 no.4
    • /
    • pp.286-290
    • /
    • 1990
  • The surface enhanced Raman scatterings of Zn(Ⅱ) tetrakis (4-N-methyl pyridyl) porphyrins were studied in silver sol. Zn(Ⅱ) tetrakis (4-N-methyl pyridyl) porphyrin was found to be adsorbed on silver surface via flat-on geometry with some inhomogeneous distribution in the orientation of pyridyl groups. Both the selective enhancement of Raman modes depending on the mode character and the theoretical arguments of SERS are utilized to support the above conclusion. The surface induced substitution reaction of Mn(Ⅲ) tetrakis (4-N-methyl pyridyl) porphyrin chloride to Ag(Ⅱ) tetrakis (4-N-methyl pyridyl) porphyrin was detected via surface enhanced Raman spectrum.