• Title/Summary/Keyword: silver alloys

Search Result 48, Processing Time 0.02 seconds

A Study on the Electrical Characteristics of Different Wire Materials

  • Jeong, Chi-Hyeon;Ahn, Billy;Ray, Coronado;Kai, Liu;Hlaing, Ma Phoo Pwint;Park, Susan;Kim, Gwang
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.20 no.4
    • /
    • pp.47-52
    • /
    • 2013
  • Gold wire has long been used as a proven method of connecting a silicon die to a substrate in wide variety of package types, delivering high yield and productivity. However, with the high price of gold, the semiconductor packaging industry has been implementing an alternate wire material. These materials may include silver (Ag) or copper (Cu) alloys as an alternative to save material cost and maintain electrical performance. This paper will analyze and compare the electrical characteristics of several wire types. For the study, typical 0.6 mil, 0.8 mil and 1.0 mil diameter wires were selected from various alloy types (2N gold, Palladium (Pd) coated/doped copper, 88% and 96% silver) as well as respective pure metallic wires for comparison. Each wire model was validated by comparing it to electromagnetic simulation results and measurement data. Measurements from the implemented test boards were done using a vector network analyzer (VNA) and probe station setup. The test board layout consisted of three parts: 1. Analysis of the diameter, length and material characteristic of each wire; 2. Comparison between a microstrip line and the wire to microstrip line transition; and 3. Analysis of the wire's cross-talk. These areas will be discussed in detail along with all the extracted results from each type the wire.

A STUDY ON THE BONDING BEHAVIOR OF PALLADIUM-BASED ALLOYS FOR CERAMO-MENTAL RESTORATION (도재 소부용 팔라디움계 합금의 도재 결합양상에 관한 연구)

  • Chang, Hoon;Lim, Ho-Nam;Choi, Boo-Byung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.27 no.1
    • /
    • pp.143-179
    • /
    • 1989
  • To observe the bonding behavior of palladium-based alloys to porcelain; 1. Pd-Co binary alloy with the higher cobalt content, 2. Pd-Co binary alloy with the lower cobalt content, 3. Pd-Ag-Sn ternary alloy, 4. Pd-Ag binary alloy, 5. Pd-Cu-Au ternary alloy and 6. Pd-Cu binary alloy were made as 6 groups of experimental alloys. Each group of alloy was divided into 4 sub-groups such as one sub-group that was not degassed and three sub-groups that degassed for 5 minutes, 10 minutes and 15 minutes. On each specimen, weight changes after degassing, morphological changes of oxide layer by changing the degassing time, compositional changes at metal-ceramic interface and bond strength of metal-ceramic measured with planar shear test were observed and compared. The results of the present study allow the following conclusions to be drawn: 1. The alloy showing the greatest bond strength was Pd-Cu alloy without gold and bond strength was decreased by alloying gold to them. 2. Although Pd-Co alloy showed the most prominent oxidation behavior, bond strength of them to porcelain was not greatly high by the formation of porosities at metal-ceramic interfaces. 3. Likewise tin, cobalt formed the peaks on line profiles at metal-ceramic interface, however copper did not exhibit such peaks on line profiles. 4. Mainly, oxide layer on Pd-Co alloy was composed with cobalt, and for Pd-Co alloy with higher cobalt content the rise of bond strength was not significant by increased degassing time. 5. On Pd-Ag alloy not containing tin, during degassing for 15 minutes silver content was increased at metal-ceramic interface. 6. As an oxidized element, tin formed the oxide layers that widen their area by increasing the degassing time, while cobalt and copper showed the morphological changes of particle or crystal on oxide layer.

  • PDF

A COMPARATIVE STUDY ON THE CHEMICAL COMPOSITION AND MECHANICAL PROPERTIES OF FOUR LOW-GOLD-CONTENT DENTAL CASTING ALLOYS MANUFACTURED IN KOREA (한국산(韓國産) 치과주조용(齒科鑄造用) 저금함유합금(低金含有合金)의 조성(組成) 및 기계적(機械的) 성질(性質)에 관(關)한 비교연구(比較硏究))

  • Chang, Ik-Tae;Yang, Jae-Ho;Kim, Chang-Whe;Kim, Kwang-Nam;Lee, Sun-Hyung;Kim, Yung-Soo;Chang, Wan-Shik
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.19 no.1
    • /
    • pp.17-27
    • /
    • 1981
  • This study was conducted to determine the chemical composition and the mechanical properties of four commercially available low gold-based crown and bridge alloy produced in Korea. Four dental casting gold-silver-palladium alloys, i.e., A, B, C and D (code of alloys) were selected for the evaluation of chemical composition, ultimate tensile strength, elongation. values and Vickers hardness. The chemical composition of test specimens was analyzed by both emission spectrography and wet gravitation method with a 1.5gm of low gold ingot. The tensile properties and Vickers hardness was determined with cast specimens treated in following three conditions; as-cast, softening heat treatment and hardening heat treatment. The tensile testing bars were cast in accordance with the model designed by Gettleman and Harrison (1969) which was modified from the A. D. A. Specification No. 14 for dental chromium-cobalt casting alloy. Nine tensile test specimens were made from a split silicone mold for each of the test alloys to the size of 2.5mm in diameter and a gauge length of 10mm. All four alloys were handled in accordance with conventional methods used in Type III gold alloys. Ultimate tensile strength and elongation were measured on an Instron Universal Tensile Testing Machine (Model 1125, Japan) operated at a crosshead rate of 0.1cm/min. Elongation values were measured using Digital Measuring Microscope (MS-152, FUSOH, Japan). Vickers hardness was determined with a Vickers Hardness Tester (Model VKH-l, Japan) at a 1.0kg load on a mounted tensile test specimen. The following results were obtained from this study; 1. All tested alloys were composed of Au, Ag, Pd, Cu, Zn and Fe in common. The composition rate of gold for all four alloys was found in the range of $42{\sim}47$ weight % as shown below. Alloy A; Au 45%, Ag 40.2%, Pd 5.76%, others 9.04%. Alloy B; Au 47.1%, Ag 29.03%, Pd 6.98%, others 16.92%. Alloy C; Au 45%, .Ag 26.9%, Pd 6.83%, others 21.07%. Alloy D; Au 41.8%, Ag 34.4%, Pd 6.95%, others 16.85%. 3. The ultimate tensile strength of the four alloys was in the range of $31{\sim}82kg/mm^2$. The test results were shown in the below order from the highest value; As-cast condition; D, B, C, A. Softening heat treament; B, C, D, A. Hardening heat treatment; D, B, C, A. 4. The test :results of the elongation rate for each alloy were in the range of $0.5{\sim}18%$. The test results were shown in the below order from the highest value; As-cast condition; A, D, B, C. Softening heat treatment; A, C, D, B. Hardening heat treatment; C, D, B, A. 5. Vickers hardness for each of the four alloys was in the range of $120{\sim}230$. The test results were shown in the below order from the highest value; As-cast condition; C, B, D, A Softening heat treatment; D, B, C, A. Hardening heat treatment; D, A, C, B. 6. There were no differences in the physical properties between as-cast condition and softening heat treatment.

  • PDF

Microstructure and Hardness Evolution in Press-formed 925 Silver Alloys (가압성형 925 은합금의 미세구조와 경도 변화)

  • Song Ohsung
    • Proceedings of the KAIS Fall Conference
    • /
    • 2005.05a
    • /
    • pp.55-57
    • /
    • 2005
  • 기존의 장신구 은제품은 무르고 주조공정 특유의 미세한 표면결함을 가져서 착웅 중 쉽게 변색되는 문제가 있었다. 본 연구에서는 내식성을 향상시키기 위해 $92.5\%Ag-6.5\%Cu-1\%Zn$의 삼원계 은합금을 기초 소재로 해서 반지장신구를 상정하여 기존의 주조공정으로 대략의 형태를 만들고 금형과 유압프레스로 성형 가압시켜서 적극적으로 주조 시에 발생한 미세기공을 제거하고 결정립을 미세화하여 표면경도와 밀도를 향상시켰다. 선반가공과 미세연마를 실시하여 내식성이 향상된 표면과 기존 주조공정에 비해 3배 이상 향상된 경도를 가져서 스프링백 효과에 의해 귀보석을 세팅할 수 있는 개선된 텐션형 은장신구 공정을 개발하였고 이때의 최적 성형 정도를 확인하였다.

  • PDF

Thermodynamic interaction parameter between Zn and Cu, Ag, In, Bi, Pb, Sn in Dilute cadmium alloy by Touch Instant electro-motive force method (순간접전기전력법에 의한 용융 Cd중의 Zn과 Cu, Ag, In, Bi, Pb 및 Sn와의 상위작용 파라미터)

  • 김대룡;윤겸하
    • Journal of the Korean institute of surface engineering
    • /
    • v.15 no.4
    • /
    • pp.192-207
    • /
    • 1982
  • A study has been made of the interaction parameters of Zn other elements in dilute solutesd solution of molten cadmium alloys over the temperature range of 450 to 570$^{\circ}C$. The experi-mental measurementss were made in a touch instant cell using a fusedd Licl-KCl electrolyte. The activity of zinc in binary and ternary solutions sexhibiteds a strong positive deviation from Raoult's law. The addition of silver, indium or lead increased the activity of zinc whereas addition of copper, bismuth or tin decreased the zinc activity slightly. The results for all the metallic solutions showed a linear dependence of reciprocal of ab-solute temperature over the experimental range. The interaction parameters obtained are as follows.

  • PDF

Titanium Ions Released from Oral Casting Alloys May Contribute to the Symptom of Burning Mouth Syndrome

  • Park, Yang Mi;Kim, Kyung-Hee;Lee, Sunhee;Jeon, Hye-Mi;Heo, Jun-Young;Ahn, Yong-Woo;Ok, Soo-Min;Jeong, Sung-Hee
    • Journal of Oral Medicine and Pain
    • /
    • v.42 no.4
    • /
    • pp.102-108
    • /
    • 2017
  • Purpose: Many metal ions released from dental casting alloys have been reported to influence the intraoral symptoms of oral lichen planus (OLP) and burning mouth syndrome (BMS). The aim of this study was to investigate the relationship between salivary metal ion levels and the prosthetic duration as well as to evaluate the time-dependent morbid effects of metal ions in OLP and BMS patients. Methods: Three study groups consist of the following subjects respectively: 17 OLP patients, 12 BMS patients, and 12 patients without oral symptoms. The salivary concentrations of 13 metal ions (copper, cobalt, zinc, chromium, nickel, aluminum, silver, iron, titanium [Ti], platinum, tin, palladium, and gold) were measured by Laser Ablation Microprobe Inductively coupled Plasma Mass Spectrometry. Results: The Ti ions had statistically significant differences among the groups with a prosthetic duration of less than 5 years. There were no significant differences between all ion levels among the groups wearing dental cast alloys for over 5 years. In the BMS group, the level of Ti ions in patients with prosthetic restorations less than 5 years old were significantly high (p<0.05). Conclusions: In the BMS group, 3-60 months during which salivary Ti levels were higher were matched with the duration of burning symptoms ($15.6{\pm}17.1months$). Furthermore, Ti ions were statistically high in the oral cavity of BMS patients fitted with dental casting alloys for 5 years. These results suggest that Ti ions released from dental implants and oral prostheses could attribute to burning sensation of BMS.

EFFECTS OF ALLOYING ELEMENTS ON VARIOUS PROPERTIES OF DENTAL SILVER-PALLADIUM ALLOYS (치과용(齒科用) 은(銀)-파라디움합금(合金)의 합금원소(合金元素)가 제성질(諸性質)에 미치는 영향(影響)에 관(關)한 연구(硏究))

  • Kim, Chun-Jin;Park, Nam-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.22 no.1
    • /
    • pp.95-108
    • /
    • 1984
  • Even though the tarnishing and corrosion problems characteristic with dental silver-palladium alloy are not yet fully solved, it is recently widely used because of its low cost. However the effects of major alloying elements on the various properties of this system are not fully understood. The object of this research is to clarify the effects of In and Zn additives on the corrosion and tarnishing resistances and precipitation hardening behavior of this sytem, using electrodynamic polarization, immersion, and Vicker's microhardness test and X-ray diffraction and electron probe micro analysis methods. The obtained results were as follows: I. As indium content is increased, both the corrosion resistance in Cl-solution and microhardness are also increased while the tarnishing resistance is decreased. 2. As Zinc content is increased, the corrosion resistance is decreased, but tarnishing resistance is increased 3. At 70Ag-25Pd-2.5Zn-2.5In composition, the precipitation harding behavior was mot significant. The optimum aging temperature was $450^{\circ}C$ and the time was 2 hrs. The resulting specimen of this work carried 180VHN. 4. Under the heat treatment, the changes in the mechanical property are due to the changes in the shape and composition of dendrite matrix, namely, it is because of the precipitation hardening behavior which has been proved by electron probe micro analysis and optical microscopic finding.

  • PDF

Manufacturing Techniques of Ancient Metal Buddha Statues from Archaeological Sites in Bagan, Myanmar

  • Lee, Jae Sung;Win, Yee Yee;Lee, Bonnie;Yu, Jae Eun
    • Journal of Conservation Science
    • /
    • v.35 no.4
    • /
    • pp.309-316
    • /
    • 2019
  • This study intends to identify manufacturing techniques, including casting and alloy composition, of nine metal Buddha statues excavated from archaeological sites in Bagan, Myanmar. Two Buddha statues from Pyu city state(2nd to 9th century) contain Cu-Sn alloy(including <1 wt% Fe), with different relatively high percentages of Sn(16 wt% and 25 wt%) identified from each Buddha statue, and no Pb detected. Five Buddha statues from the Bagan dynasty contain various alloy ratios of Cu-Sn(including <1 wt% Pb), Cu-Sn-Pb, and Cu-Sn-Zn-Pb. All Buddha statues appear to be fabricated by casting, as there is no evidence of other heat treatments. The silver Buddha statue manufactured in the 18th century includes >1% Cu besides silver with no additional metallic components identified. The bronze Buddha statue manufactured in the Konbaung dynasty(18th century) is of Cu-Sn-Pb alloy. The Buddha statues of Pyu was alloy of Cu-Sn without Pb including ahigh percentage of The Buddha statues of both the Bagan and Konbaung dynasties are comprised of ternary Cu-Sn-Pb alloys, with a heterogeneous distribution of lead and tin. Some of Buddha statues of the Bagan dynasty have similar alloy ratios as those of Pyu, suggesting that similar manufacturing techniques were used.

Effects of the Atmosphere on the Comparative Solderability of Lead-Tin and Lead-Free Solders

  • Bin, Jeong-Uk;S.M.Adams;P.F.Stratton
    • Proceedings of the International Microelectronics And Packaging Society Conference
    • /
    • 2001.04a
    • /
    • pp.45-47
    • /
    • 2001
  • Due to pressure from threatened legislation in Europe, consumer and governmental pressure in Japan, and glob머 market considerations in the US, there is a rapidly growing interest in lead-free solderinger, Although the move to lead free soldering seems inevitable, many problems will arise in production assembly. It is generally acknowledged that the lead-free solders available offer a much s smaller process window than lead/tin, related mainly to the higher soldering temperatures which naturally result from increases of liquidus temperatures of at least 300 C. However, raising reflow temperatures from the current 220-2300 C to 250 2600 C will lead to problems with the boards and components as well as i increasing oxidation effects. There is a need to keep reflow temperatures low without reducing solderablity. Some results on benefits of inert atmospheres are discussed in this paper. For example, testing in a nitrogen atmosphere, with 300 ppm oxygen, by the N National Physical Laboratory (NPU has revealed clear benefits for ine$\pi$mg lead-free alloys, by restoring the solderability to lead/tin levels, by enabling lower soldering temperatures. However, there has been little testing over a range of oxygen levels in nitrogen and this is an important issue in determining n nitrogen supply and oven costs. Some results are reported here from work by NPL conducted for BOC in w which solderability was evaluated for tin기ead and tin/silver/copper eutectic a alloys in a wetting balance over a range of oxygen levels form 10 ppm to 21% ( (air). The studies confirm that acceptable wetting times occur in inert atmospheres a at soldering temperatures 20 to 300 C lower than are possible in air.

  • PDF

A Study of Weldability for Pure Titanium by Nd:YAG Laser(I) - Weld Properties with Shield Conditions - (순티타늄판의 Nd:YAG 레이저 용접성에 관한 연구(I) - 실드 조건에 따른 용접특성 -)

  • Kim, Jong-Do;Kwak, Myung-Sub;Kim, Chang-Soo
    • Journal of Welding and Joining
    • /
    • v.27 no.5
    • /
    • pp.55-61
    • /
    • 2009
  • Pure titanium and its alloys have good formability, excellent corrosion resistance and high strength to weight ratios. Therefore, it has been using to heat exchangers, offshore plants, sports equipments, and etc. As broad as its application fields, it also increases welding locations. Conventional GTAW and GMAW are very popular welding methods of titanium, but it has a high heat input and wide HAZ. It has a possibility of inducing Stress Corrosion Cracking. So, laser welding method has been using to get reliable welds by reducing heat input. Weld beads change its color to silver, gold, brown, blue, and gray by shied conditions. And the closer to gray, the more oxidize, nitride and embrittlement. The most effective atom to embrittlement was nitrogen. And shield gas flow was not so effective over the constant flow rates. In this study, weld properties of the pure titanium were investigated by pulsed & CW Nd:YAG lasers and evaluated by various shield conditions. And It is observed that nitrogen is more effective to oxidation and embrittlement of titanium compared with oxygen by oxygen and nitrogen quantitative analysis.