• 제목/요약/키워드: silver alloys

검색결과 48건 처리시간 0.02초

Electrochemistry and Leaching Kinetics of Gold-Silver Alloys in Cyanide Solutions

  • Guan, Y.Charles;Sun, Xiaowei;Han, Kenneth N.
    • 자원리싸이클링
    • /
    • 제10권1호
    • /
    • pp.42-48
    • /
    • 2001
  • The dissolution behavior of gold and silver from gold-silver alloys in aerated cyanide solutions has been investigated by an electrochemical means as well as a direct measurement of gold and silver ions reported in the bulk solution as a function of time using rotating disc electrodes. The variables studied included oxygen partial pressure, rotating speed of the disc, concentration of cyanide, temperature and composition of the allyos. The dissolution potential and the rate of dissolution were obtained in view of the anodic and cathodic current-potential relationships. The results were discussed in terms of the mixed potential theory. The results showed that the dissolution rate of gold and silver from the alloys was controlled partially by chemical reaction. but largely by transport of either oxygen or cyanide, depending on their relative concentration under the experimental conditions employed in this study.

  • PDF

Ge, In 첨가 은합금 주조물의 가압성형에 따른 물성변화 연구 (Property of Ge, In Added Silver Alloy with Plastic Deformation)

  • 김준환;송오성
    • 한국산학기술학회논문지
    • /
    • 제11권5호
    • /
    • pp.1547-1551
    • /
    • 2010
  • 통상의 은합금 장신구 재료로 쓰이는 925 은합금 (Ag-7.5wt%Cu)의 가공 중 고온산화에 의한 변색 또는 착용 중 산화에 의한 색변화를 방지하기 위해서 Ag-5wt%Ge-2.5wt%Cu, 5wt%In-2.5wt%Cu의 새로운 조성을 제안하였다. 전체는 기존 925 은합금의 조성을 유지하여 기존 7.5wt%Cu합금원소를 Ge, In으로 대치하여 기존 925 은합금과 비교하여 주조공정 시의 형상변화와 주조능, 가공경화에 의한 물성과 내식성 변화를 확인하였다. 새로이 제안된 Ge, In 은합금은 기존 925은합금과 동일하거나 우수한 주조특성을 보였고, 특히 가공 중에 생기는 가공경화능력이 우수하여 내구성이 증가하였고 고온 내식성과 신체 착용 시의 내부식성이 향상됨을 확인하였다.

치은 섬유아세포(纖維芽細胞)에 대(對)한 은(銀)-파라디움합금(合金)의 세포독성(細胞毒性)에 관(關)한 연구(硏究) (AN EXPERIMENTAL STUDY OF THE CYTOTOXICITY OF SILVERPALLADIUM ALLOYS UPON GINGIVAL FIBROBLAST BY MEANS OF TISSUE CULTURE)

  • 유인탁;최부병;김인철
    • 대한치과보철학회지
    • /
    • 제21권1호
    • /
    • pp.9-26
    • /
    • 1983
  • In order to investigate the biocompatibility of silver-palladium alloys, gingival fibroblast was obtained from a healthy human gingival and cultured in MEM medium with the addition of silverpalladium alloys. Four different mixture of silver-palladium alloys comprising of Ag-Pd-Au, Ag-Pd-In and Ag-Sn were tested. Results were assessed by calculating the cell multiplication rate per millimeter of medium and morphological changes in cells were also observed and noted.The obtained results were as follows; 1. Ag-Pd-Au alloy was indicated to be most biocompatible with gingival fibroblast. Also there was a decrease in cytotoxicity of the alloy as the concentration of gold increased. 2. Ag-Pd alloy showed a decrease in cell multiplication rate as compared to Ag-Pd~Au alloy. 3. Silver-palladium alloy supplemented with Indium increased the cell multiplication rate. 4. Among the alloys tested, Ag-Sn alloy was indicated to be the most cytotoxic and the least biocompatible with human gingival fibroblast.

  • PDF

백색금 합금용 모합금의 실리콘 함량에 따른 물성변화 (Properties of the Master Alloys for White Gold Products with Silicon Contents)

  • 송정호;노윤영;이현우;최민경;송오성
    • 한국재료학회지
    • /
    • 제25권2호
    • /
    • pp.90-94
    • /
    • 2015
  • We prepared 8 samples of non-silver and silver-added master alloys containing silicon to confirm the existence of nickel-silicides. We then prepared products made of 14K and 18K white gold by using the prepared master alloys containing 0.25, 0.35, and 0.50 wt% silicon to check for nickel release. We then employed the EN 1811 testing standard to investigate the nickel release of the white gold products, and we also confirmed the color of the white gold products with an UV-VIS-NIR-color meter. We observed $NiSi_x$ residue in all master alloys containing more than 0.50 wt% Si with EDS-nitric acid etching. For the white gold products, we could not confirm the existence of $NiSi_x$ through XRD after aqua-regia etching. In the EN 1811 test, only the white gold products with 0.25 wt% silicon master alloys successfully passed the nickel release regulations. Moreover, we confirmed that our white gold products showed excellent Lab indices as compared to those of commercial white gold ones, and the silver-added master alloys offered a larger L index. Our results indicate that employing 0.25 wt% silicon master alloys might be suitable for white gold products without nickel-silicide defects and nickel release problems.

진공증착법으로 제작한 Ag-X(X=Cu,Ni,C) 합금의 기계적 성질에 관한 연구 (A Study on the Mechanical Properties of Ag-X(X=Cu,Ni,C) Alloys Prepared by the Vacuum-deposition Technique)

  • 오창섭;한창석
    • 열처리공학회지
    • /
    • 제24권5호
    • /
    • pp.243-250
    • /
    • 2011
  • When alloys are vacuum-deposited on cooled substrates, super-rapidly cooled alloy films in the unequilibrium state can be obtained. As an application of this method, Ag-Cu, Ag-Ni and Ag-C alloys were successfully produced, and their mechanical properties with tempering temperature were investigated. The following results were obtained : (1) In case of Ag-Cu alloys, the solid solution was hardened by tempering at $150^{\circ}C$. The hardening is considered to occur when the solid solution begins to decompose into ${\alpha}$ and ${\beta}$ phases. The Knoop hardness number of a 40 at.%Ag-Cu alloy film deposited on a cooled glass substrate was 390 $kg/mm^2$. The as-deposited films were generally very hard but fractured under stresses below their elastic limits. (2) In case of Ag-Ni and Ag-C alloys, after the tempering of 4 at.%Ni-Ag alloy at $400^{\circ}C$ and of 1 and 2 at.%C-Ag alloys at $200^{\circ}C$, they were hardened by the precipitation of fine nickel and carbon particles. The linear relationship between proof stress vs. $(grain\;diameter)^{-l/2}$ for bulk silver polycrystals can be applied to vacuum-deposited films up to about 0.1 ${\mu}m$ grain diameter, but the proof stress of ultra-fine grained silver with grain diameters of less than 0.1 ${\mu}m$ was smaller than the value expected from the Petch's relation.

Studies on the Interaction of Alkyl Thiophosphinate with Precious Metals

  • 김동수
    • Bulletin of the Korean Chemical Society
    • /
    • 제16권4호
    • /
    • pp.321-325
    • /
    • 1995
  • Adsorption mechanisms of diisobutyl dithiophosphinate (DIBDTPI) and diisobutyl monothiophosphinate (DIBMTPI) on gold and gold-silver alloys (80:20 and 50:50) have been studied. The adsorption mechanisms on gold-silver alloys can be explained by the EC mechanism involving an electron transfer step and a chemical reaction step. Thus, the adsorption should be controlled by the E of the electrochemical oxidation of the electrode involved and the pK of the metal collector complex. Both di- and mono- thiophosphinate adsorb on 50:50 Au-Ag alloy at lower potential than on 80:20 Au-Ag alloy surface. There are no significant differences between the reactivities of DIBDTPI and DIBMTPI with precious metals except that the dithio- compound can be oxidized to dimer on gold at high potentials, while the monothio- homologue cannot. In this regard, DIBDTPI may be a better surface active reagent for pure gold than DIBMTPI.

Corrosion of Dental Au-Ag-Cu-Pd Alloys in 0.9 % Sodium Chloride Solution

  • Chiba, Atsushi;Kusayanagi, Yukiharu
    • Corrosion Science and Technology
    • /
    • 제4권1호
    • /
    • pp.19-22
    • /
    • 2005
  • Two Au-Ag-Cu-Pd dental casting alloys (Au:12% and 20%) used. The test solutions used 0.9 % NaCl solution (isotonic sodium chloride solution), 0.9 % NaCl solution containing 1 % lactic acid, and 0.9 % NaCl solution containing 1 % lactic acid and 0.1 mol $dm^{-3}$ $Na_2S$. The surface of two samples in three sample solutions was not natural discoloration during one year. The alloy containing 12 % gold was easily alloyed and the composition was uniform comparing with the alloy containing 20 % gold. The rest potentials have not a little effect after three months. The kinds of metals could not definitely from the oxidation and reduction waves of metal on the cyclic voltammograms. The dissolutions of gold and palladium were 12 % Au sample in the 0.9 % NaCl solution containing 1 % lactic acid and 0.1 mol $dm^{-3}$ $Na_{2}S$. The pH of solution had an affect on dissolution of copper, and sulfur ion had an affect on dissolution of silver. The copper dissolved amount from 20 % gold sample was about 26 times comparing with that of 12 % gold sample in the 0.9 % solution containing 1 % lactic acid. Corrosion products were silver chloride and copper chloride in NaCl solution, and silver sulfide and copper sulfide in NaCl solution containing $Na_{2}S$.

치과주조용 금-은-팔라듐합금의 물리적 특성에 관한 연구

  • 김철위
    • 대한치과의사협회지
    • /
    • 제20권12호통권163호
    • /
    • pp.1073-1081
    • /
    • 1982
  • The purpose of this study was to measure and compare the tensile strengths, elongation and Vicker's hardness values by heat treatments of three·commercial dental casting gold-silver-palladium alloys(Type A,B and G-50 alloys) used in Korea. Instron universal testing instrument and Vicker's hardness tester were used to determine their physical properties. The following results were obtained with the alloys tested. 1. It was determined that the tensile strengths generally tended to increase as the hardened condition (55.50 - 72.98 Kg/mm₂)than in softened condition (28.75 - 41.16 Kg/mm₂). 2. The results indicated that the elongation was the highest in the softened condition(12.30 - 27.0 %), and was the smallest in the hardened condition (3.6 - 5.8 %). 3. It was found that the Vicker's hardness number was the greatest in type G-50 hardened alloys (304.0), and the smallest in the type A softened alloys (130.0).

  • PDF

A comparative study on the bond strength of porcelain to the millingable Pd-Ag alloy

  • Hong, Jun-Tae;Shin, Soo-Yeon
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권5호
    • /
    • pp.372-378
    • /
    • 2014
  • PURPOSE. The porcelain fused to gold has been widely used as a restoration both with the natural esthetics of the porcelain and durability and marginal fit of metal casting. However, recently, due to the continuous rise in the price of gold, an interest towards materials to replace gold alloy is getting higher. This study compared the bond strength of porcelain to millingable palladium-silver (Pd-Ag) alloy, with that of 3 conventionally used metal-ceramic alloys. MATERIALS AND METHODS. Four types of metal-ceramic alloys, castable nonprecious nickel-chrome alloy, castable precious metal alloys containing 83% and 32% of gold, and millingable Pd-Ag alloy were used to make metal specimens (n=40). And porcelain was applied on the center area of metal specimen. Three-point bending test was performed with universal testing machine. The bond strength data were analyzed with a one-way ANOVA and post hoc Scheffe's tests (${\alpha}=.05$). RESULTS. The 3-point bending test showed the strongest ($40.42{\pm}5.72$ MPa) metal-ceramic bond in the nonprecious Ni-Cr alloy, followed by millingable Pd-Ag alloy ($37.71{\pm}2.46$ MPa), precious metal alloy containing 83% of gold ($35.89{\pm}1.93$ MPa), and precious metal alloy containing 32% of gold ($34.59{\pm}2.63$ MPa). Nonprecious Ni-Cr alloy and precious metal alloy containing 32% of gold showed significant difference (P<.05). CONCLUSION. The type of metal-ceramic alloys affects the bond strength of porcelain. Every metal-ceramic alloy used in this study showed clinically applicable bond strength with porcelain (25 MPa).

Corrosion Mechanisms of New Wrought Mg-Zn Based Alloys Alloying with Si, Ca and Ag

  • Ben-Hamu, G.;Eliezer, D.;Shin, K.S.;Wagner, L.
    • Corrosion Science and Technology
    • /
    • 제7권3호
    • /
    • pp.152-157
    • /
    • 2008
  • New wrought magnesium alloys have increasingly been developed in recent years for the automotive industry due to their high potential as structural materials for low density and high strength/weight ratio demands. However, their poor mechanical properties and low corrosion resistance have led to a search for new kinds of magnesium alloys with better strength, ductility, and high corrosion resistance. The main objective of this research is to investigate the corrosion behaviour of new magnesium alloys: Mg-Zn-Ag (ZQ), Mg-Zn-Mn-Si (ZSM) and Mg-Zn-Mn-Si-Ca (ZSMX). These ZQ6X, ZSM6X1, and ZSM651+YCa alloys were prepared using hot extrusion. AC, DC polarization and immersion tests were carried out on the extruded rods. Microstructure was examined using optical and electron microscopy (SEM) and EDS. The addition of silver decreased the corrosion resistance. The additions of silicon and calcium also affected the corrosion behaviour. These results can be explained by the effects of alloying elements on the microstructure of Mg-Zn alloys such as grain size and precipitates caused by the change in precipitation and recrystallisation behaviour.