• 제목/요약/키워드: silicone

검색결과 1,446건 처리시간 0.032초

Silicone breast implant modification review: overcoming capsular contracture

  • Shin, Byung Ho;Kim, Byung Hwi;Kim, Sujin;Lee, Kangwon;Choy, Young Bin;Heo, Chan Yeong
    • 생체재료학회지
    • /
    • 제22권4호
    • /
    • pp.319-327
    • /
    • 2018
  • Background: Silicone implants are biomaterials that are frequently used in the medical industry due to their physiological inertness and low toxicity. However, capsular contracture remains a concern in long-term transplantation. To date, several studies have been conducted to overcome this problem. This review summarizes and explores these trends. Main body: First, we examined the overall foreign body response from initial inflammation to fibrosis capsule formation in detail and introduced various studies to overcome capsular contracture. Secondly, we introduced that the main research approaches are to inhibit fibrosis with anti-inflammatory drugs or antibiotics, to control the topography of the surface of silicone implants, and to administer plasma treatment. Each study examined aspects of the various mechanisms by which capsular contracture could occur, and addressed the effects of inhibiting fibrosis. Conclusion: This review introduces various silicone surface modification methods to date and examines their limitations. This review will help identify new directions in inhibiting the fibrosis of silicone implants.

실리콘 하이드로겔 렌즈의 반복적 건조로 인한 렌즈형태 및 자·타각적 증상의 변화 (The Change in the Parameters of Silicone Hydrogel Lens and Objective/Subjective Symptoms induced by Repetitive Dryness of Lens)

  • 김소라;강병호;정인필;박미정
    • 한국안광학회지
    • /
    • 제17권4호
    • /
    • pp.381-388
    • /
    • 2012
  • 목적: 본 연구에서는 반복적인 건조에 의해 유발되는 실리콘 하이드로겔 렌즈의 형태 변화 및 착용시의 자 타각적 증상의 변화에 대해 알아보고자 하였다. 방법: 재질 혹은 두께가 다른 실리콘 하이드로겔 렌즈를 4회씩 건조하고 수화시킨 후 전체 직경과 베이스커브의 변화를 비교하였으며, 건조되었던 실리콘 하이드로겔 렌즈를 착용한 후 착용자의 자각적 증상 및 비침입성 눈물막 파괴시간과 순목횟수를 측정하였다. 결과: 반복되는 건조와 수화로 인하여 모든 실리콘 하이드로겔 렌즈의 전체 직경과 베이스커브가 증가하였다. 전체 직경과 베이스커브가 변하는 정도는 재질에 따라 각기 상이하였으며 두꺼운 렌즈에서는 건조수화 횟수에 따라 불규칙적인 변화가 나타났다. 실리콘 하이드로겔 렌즈의 재질이나 두께에 관계없이 건조수화 과정을 거친 렌즈를 착용하였을 때에는 착용자의 비침입성 눈물막 파괴시간은 감소하였으며, 순목횟수는 증가하였다. 또한, 반복적인 건조수화는 렌즈의 착용감에도 영향을 미쳐 가려움, 통증, 자극감, 이물감, 건조감이 증가하는 경향이 있었다. 결론: 본 연구 결과를 통하여 반복적인 건조수화로 실리콘 하이드로겔 렌즈의 형태 변화 및 이에 따른 착용감 저하 유발을 확인하였으므로 건조한 환경에 대하여 강한 내구성을 가지는 실리콘 하이드로겔 콘택트렌즈의 개발 필요성을 제안할 수 있다.

실리콘 복합체의 내화 및 전기 특성에 관한 연구 (A Study on the Flame Retardance and Electrical Properties of Silicone Composites)

  • 이성일;이해준
    • Elastomers and Composites
    • /
    • 제38권3호
    • /
    • pp.227-234
    • /
    • 2003
  • 배합고무에 각종 표면처리제로 처리한 수산화 알루미늄을 무게비 100:20, 100:40, 100:60, 100:80 및 100:100으로 배합하여 고압애자용 실리콘 복합체(HVI SC)를 제조하였다. 배합 공정에서 지방산, 아크릴 실란 및 비닐 실란등의 표면처리제로 수산화 알루미늄을 표면처리하였다. 수산화알루미늄의 첨가량 및 표면처리제의 종류에 따른 기계적 특성 및 전기적 특성을 연구하였다. 수산화 알루미늄의 첨가량이 증가하면서 인장강도, 신장율 및 인열강도는 감소하였으며, 비닐 실란으로 표면처리한 수산화 알루미늄을 첨가한 HVI SC의 인장강도 및 탄성율은 지방산 및 아크릴 실란을 사용한 HVI SC 보다 우수하였다. 또한 비닐 실란을 사용한 HVI SC의 체적저항, 절연파괴강도 및 내트래킹 특성이 지방산 및 아크릴 실란을 사용한 HVI SC 보다 우수하였다. 표면처리제의 종류에 따른 실리콘 복합체의 고분자 충전작용은 결합고무 함량으로 검토하였다. 실험의 결과로는 비닐 실란을 표면처리제로 사용한 실리콘 복합체의 결합고무 함량이 다른 표면처리제를 사용한 것 보다 높았다 표면처리제의 종류에 따른 실리콘 복합체의 가교밀도는 Rheometer로 측정하였다 비닐 실란을 표면처리한 수산화 알루미늄을 충진한 실리콘복합체의 최대토크가 다른 표면처리제를 사용한 것들 중에 가장 높았다.

Silicone Fluid들이 실리콘 고무의 절연특성에 미치는 영향(1) (Effects of Silicone Fluids on Insulation Properties of Silicone Rubber)

  • 강동필;박효열;안명상;김대환;이후범;오세호
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 춘계학술대회 논문집 유기절연재료 방전 플라즈마연구회
    • /
    • pp.40-43
    • /
    • 2003
  • 전기방전에 대한 shed 재료의 열화내성과 우수한 발수성의 장기간 유지특성은 폴리머 애자의 장기성능에 있어서 가장 중요한 인자들이다. 애자 제조시 무결점 성형성 또한 중요한데 열화내성을 확보하기 위해 다량의 ATH의 첨가가 수반되기 때문에 적절한 process oil의 사용이 불가피하다. 사용하는 오일의 종류와 량에 따라 옥외절연물의 장기성능에 영향을 주는 표면발수성이나 방전내성은 크게 차이가 나는 것으로 밝혀지고 있다. 본 논문에서는 화학적 구조와 정도가 다른 몇 가지 실리콘 fluid들을 실리콘 고무에 처방하여 기본물성과 초고압 옥외절연물의 shed 재료로서 장기성능에 영향을 주는 방전열화내성과 표면발수성의 회복특성을 평가하였다. 실리콘 고무의 무결점 사출성형에 가소도가 중요한데 동일한 무기물 첨가조건에서 유사한 가소도를 갖게 하는데 필요한 량은 fluid들의 종류에 따라서 상당한 차이가 있었다. 특히 PDMS는 점도는 낮지만 분자량이 커서 많은 량이 첨가되어 기계적 특성저하가 크게 일어났다. 코로나 처리후 발수성 회복특성은 fluid들의 분자크기와 반응기의 종류에 따라 상당히 영향을 받았으며 분자가 클수록 초기회복속도는 다소 느려도 최종의 상시발수성은 다소 높게 유지되었으며 2일 이내에 거의 초기 접촉각으로 회복되었다. 내아크성은 무게손실이 적을수록 오차범위도 작은 안정된 특성을 보였으며 fluid들의 종류에 따른 무게손실의 차이는 크지 않았다. 트래킹 방전에 의한 무게 감소는 fluid의 분자가 크면서 페닐기를 가진 fluid들이 첨가된 고무가 우수한 특성을 보였다.

  • PDF

망막박리에서 일차수술로 유리체절제술과 실리콘 주입술에 대한 임상결과 분석 (Clinical Results of Silicone Oil Injection following Vitrectomy as a Primary Procedure in Retinal Detachment)

  • 길현경;이무식;황혜정
    • 한국산학기술학회논문지
    • /
    • 제10권12호
    • /
    • pp.3919-3924
    • /
    • 2009
  • 본 연구는 망막박리에서 실리콘 기름주입술에 대한 임상적 결과를 분석한 것이다. 1999년부터 2002년까지 유리체절제술과 실리콘기름 주입술를 받은 44명 환자의 45안을 연구하였다. 결과는 다음과 같다. 1. 유리체절제술 후 시력이 두 줄 이상 호전된 경우는 45안 중 24안(53%)이었으며, 45안 중 18안(40%)에서는 시력의 변화가 없었다. 2. 실리콘기름 주입술 후 16안(6.3%)에서 실리콘기름을 제거하였으며 그 중 1안에서 망막박리가 재발되어 실리콘기름 재주입술을 시행하여 망막재유착을 이루었다. 3. 재수술을 포함하여 해부학적인 재유착은 45안 중 44안(97%)에서 이루었다. 4. 실리콘기름주입 후 발생한 합병증은 백내장(16안), 녹내장(10안), 실리콘기름의 유화(5안), 각막병증(2안), 재발성 망막박리 (1안)이었다. 결론적으로 망막박리 환자에게 일차수술로 유리체 절제술 후 유리체 대용물로 실리콘 기름을 사용하는 것은 여러 합병증의 발생에도 불구하고 높은 해부학적 성공률과 시력 개선효과를 보여주었다.

Low Magnetic Field MRI Visibility of Rubber-Based Markers

  • Kim, Jeong Ho;Jung, Seongmoon;Kim, Jung-in
    • 한국의학물리학회지:의학물리
    • /
    • 제30권4호
    • /
    • pp.89-93
    • /
    • 2019
  • Purpose: This study aims to develop new markers based on silicone rubber and urethane rubber to enhance visibility in low magnetic field magnetic resonance (MR) imaging. Methods: Four types of markers were fabricated using two different base materials. Two of the markers were composed of two different types of silicone rubber: DragonSkin™ 10 MEDIUM and BodyDouble™ SILK. The other two markers were composed of types of urethane rubber: PMC™ 780 DRY and VytaFlex™ 20. Silicone oil (KF-96 1000cs) was added to the fabricated markers. The allocated amount of oil was 20% of the weight (wt%) of each respective marker. The MR images of the markers, with and without the silicone oil, were acquired using MRIdian with a low magnetic field of 0.35 T. The signal intensities of each MR image for the markers were analyzed using ImageJ software and the visibility for each was compared. Results: The highest signal intensity was observed in VytaFlex™ 20 (279.67±3.57). Large differences in the signal intensities (e.g., 627% in relative difference between BodyDouble™ SILK and VytaFlex™ 20) among the markers were observed. However, the maximum difference between the signal intensities of the markers with the silicone oil showed only a 62% relative difference between PMC™ 780 DRY and DragonSkin™ 10 MEDIUM. An increase in the signal intensity of the markers with the silicone oil was observed in all markers. Conclusions: New markers were successfully fabricated. Among the markers, DragonSkin™ 10 MEDIUM with silicone oil showed the highest MR signal intensity.

Comparison of the marginal fit of milled yttrium stabilized zirconium dioxide crowns obtained by scanning silicone impressions and by scanning stone replicas

  • Yus, Estefania Aranda;Cantarell, Josep Maria Anglada;Alonso, Antonio Minarro
    • The Journal of Advanced Prosthodontics
    • /
    • 제10권3호
    • /
    • pp.236-244
    • /
    • 2018
  • PURPOSE. To determine the discrepancy in monolithic zirconium dioxide crowns made with computer-aided design and computer-aided manufacturing (CAD/CAM) systems by comparing scans of silicone impressions and of master casts. MATERIALS AND METHODS. From a Cr-Co master die of a first upper left molar, 30 silicone impressions were taken. The 30 silicone impressions were scanned with the laboratory scanner, thus obtaining 30 milled monolithic yttrium stabilized zirconium dioxide (YSZD) crowns (the silicone group). They were poured and the working models were scanned, obtaining 30 milled monolithic yttrium stabilized zirconium dioxide (YSZD) crowns (the plaster group). Three predetermined points were analyzed in each side of the crown (Mesial, Distal, Vestibular and Palatal), and the marginal fit was evaluated with SEM (${\times}600$). The response variable is the discrepancy from the master model. A repeated measures ANOVA with two within subject factors was performed to study significance of main factors and interaction. RESULTS. Mean marginal discrepancy was $22.42{\pm}35.65{\mu}m$ in the silicone group and $8.94{\pm}14.69{\mu}m$ in the plaster group. The statistical analysis showed significant differences between the two groups and also among the four aspects. Interaction was also significant (P=.02). CONCLUSION. The mean marginal fit values of the two groups were within the clinically acceptable values. Significant differences were found between the groups according to the aspects studied. Various factors influenced the accuracy of digitizing, such as the design, the geometry, and the preparation guidance, as well as the texture, roughness and the color of the scanned material.

국내 생산 콘택트렌즈의 물리적 특성 비교 -산소전달률을 중심으로- (Comparison of Physical Properties of Domestic Contact Lenses -Focusing on oxygen transmissibility-)

  • 김기성
    • 한국융합학회논문지
    • /
    • 제9권1호
    • /
    • pp.393-403
    • /
    • 2018
  • 산소전달률이 높은 것으로 알려진 실리콘 하이드로젤 콘택트렌즈의 사용이 증가하고 있지만 함수율과 산소전달률 등 물리적 특성이 표시되지 않은채 판매되고 있다.본 연구에서는 국내에서 허가된 실리콘 하이드로젤 콘택트렌즈의 함수율과 산소전달률 등의 물리적 특성을 분석하기 위하여, 식품의약품안전처 웹사이트에 공개된 허가정보를 수집 분석하였다. 본 연구에서 분석된 국산 실리콘 하이드로젤 콘택트렌즈 68건 가운데 61건(89.7%)이 산소투과성에 관한 국제규격을 만족하지 못하였다. 실리콘 하이드로젤 콘택트렌즈에 대한 국내규격이 부재하여 하이드로젤 콘택트렌즈와 차이가 없는 제품도 실리콘 하이드로젤 콘택트렌즈로 신고되었기 때문으로 판단된다. 앞으로 신고된 정보 뿐만 아니라 유통되고 있는 실리콘 하이드로젤 콘택트렌즈의 물리적 특성에 대한 분석이 요구된다.

반전된 U자형 실리콘 시트를 이용한 코뼈골절의 치료 (Treatment of Nasal Bone Fracture with Reverse U-Shaped Silicone Sheet)

  • 최환준;위서영;최창용
    • Archives of Plastic Surgery
    • /
    • 제36권2호
    • /
    • pp.242-246
    • /
    • 2009
  • Purpose: The majority of nasal bone fractures have been managed by routine procedure of closed reduction and intranasal packing. However, nasal packing can cause nasal injury, hypoxia and patient's discomfort. And, synechiae formation is a frequently occurred after the nasal surgery. Various methods are used to reduce the incidence of synechiae formation. The purpose of this study was to compare routine procedure and nasal packing with reverse "U" shaped silicone sheet with respect to postoperative nasal synechiae formation and final outcome. Methods: We analyzed the medical records of 100 patients with nasal bone fracture who were operated by closed reduction in the last one year. The silicone sheet was designed in reverse "U" fan - shape and inserted between the middle turbinate and the septal wall. Nasal packing was removed at two days after the operation, and silicone sheet was removed at 10 to 14 days. Results: Synechiae in the middle meatus developed in 2 of 75 patients. Although synechiae between the middle meatus and nasal septum occurred in patients, the patients did not complaint of any olfactory disturbance and nasal obstruction. Conclusion: The reverse "U" fan - shape silicone sheet caused less pain for patients and no significant differences in outcome were found. The results of this study suggest that insertion of silicone sheet between the middle meatus and septum can be a useful method in the prevention of intranasal synechiae formation. The reverse "U" silicone sheet is a good alternative for routine packing methods.

치태제거 및 치은염증에 대한 실리콘 칫솔의 효과 (The Effect of Silicone Toothbrush on Plaque Control and Gingival Inflammation. A Comparative Clinical Study)

  • 정예진;김창성;서종진;조규성;채중규;김종관;최성호
    • Journal of Periodontal and Implant Science
    • /
    • 제30권4호
    • /
    • pp.911-923
    • /
    • 2000
  • A comparative clinical study on the ordinary toothbrush($Buttler^{(R)}$, America) and the silicone toothbrush($Jefe^{(R)}$, Korea) was performed. The volunteers who took part in this study were students of Dental college of Yonsei University and patients attending Dental Hospital of Yonsei University. They were classified into two group, control and experimental group. Control group brushed with nylon toothbrush and experimental group did with silicone toothbrush under the researcher's guidances. Volunteers were examined on Plaque Index(PI), Gingival Index(GI), Probing Depth(PD), Bleeding on Probing(BP) and Recession(R) at base line, 1st. week, 2nd. week and 4th. week. According to the results, both group have the tendency of improvement in the degrees of GI, PI and the improvement degree of GI of both group has the significant differences from base line statistically, and there are not statistically significant differences between the silicone and nylon group in respect of PI, GI values. So based on the present study, it could be carefully ascertained that the silicone toothbrush has similar effect with nylon toothbrush in respect of PI and GI. If it is sure that the silicone toothbrush is seldom abrasive and possibly enough to massage the gingiva, this new brush is worth to be recommended by the dentists.

  • PDF