• Title/Summary/Keyword: signal-to-echo ratio

Search Result 103, Processing Time 0.034 seconds

Tracking Performance Improvement of the Double-Talk Robust Algorithm for Network Echo Cancellation (네트워크 반향제거를 위한 동시통화에 강인한 알고리듬의 추적 성능 개선)

  • Yoo, Jae-Ha
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.12 no.1
    • /
    • pp.195-200
    • /
    • 2012
  • We present a new algorithm which can improve the tracking performance of the double-talk robust algorithm. A detection method of the echo path change and a modification method for the update equation of the conventional adaptive filter are proposed. A duration of the high error signal to scale parameter ratio varies according to the call status and this property is used to detect the echo path change. The proposed update equation of the adaptive filter improves the tracking performance by prohibiting wrong selection of the error signal. Simulations using real speech signals and echo paths of the ITU-T G.168 standard confirmed that as compared to the conventional algorithm, the proposed algorithm improved the tracking performance by more than 4 dB.

Wavelet Analysis of Ultrasonic Echo Waveform and Application to Nondestructive Evaluation (초음파 에코파형의 웨이브렛 변환과 비파괴평가에의 응용)

  • Park, Ik-Keun;Park, Un-Su;Ahn, Hyung-Keun;Kwun, Sook-In;Byeon, Jai-Won
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.20 no.6
    • /
    • pp.501-510
    • /
    • 2000
  • Recently, advanced signal analysis which is called "time-frequency analysis" has been used widely in nondestructive evaluation applications. Wavelet transform(WT) and Wigner Distribution are the most advanced techniques for processing signals with time-varying spectra. Wavelet analysis method is an attractive technique for evaluation of material characterization nondestructively. Wavelet transform is applied to the time-frequency analysis of ultrasonic echo waveform obtained by an ultrasonic pulse-echo technique. In this study, the feasibility of noise suppression of ultrasonic flaw signal and frequency-dependent ultrasonic group velocity and attenuation coefficient using wavelet analysis of ultrasonic echo waveform have been verified experimentally. The Gabor function is adopted the analyzing wavelet. The wavelet analysis shows that the variations of ultrasonic group velocity and attenuation coefficient due to the change of material characterization can be evaluated at each frequency. Furthermore, to assure the enhancement of detectability and naw sizing performance, both computer simulated results and experimental measurements using wavelet signal processing are used to demonstrate the effectiveness of the noise suppression of ultrasonic flaw signal obtained from austenitic stainless steel weld including EDM notch.

  • PDF

A Study on Suppression of Ultrasonic Background Noise Signal using wavelet Transform (Wavelet변환을 이용한 초음파 잡음신호의 제거에 관한 연구)

  • 박익근
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.8 no.1
    • /
    • pp.135-141
    • /
    • 1999
  • Recently, advance signal analysis which is called "Time-Frequency Analysis" has been developed. Wavelet and Wigner Distribution are used to the method. Wavelet transform(WT) is applied to time-frequency analysis of waveforms obtained by an ultrasonic pulse-echo technique. The Gabor function is adopted as the analyzing wavelet. Wavelet analysis method is an attractive technique for evolution of material characterization evoluation. In this paper, the feasibility of suppression of ultrasonic background noise signal using WT has been presented. These results suggest that ultrasonic background noise ginal can be suppressed and enhanced even for SNR of 20.8 dB. This property of the WT is extremely useful for the detecting flaw echos embedded in background noise.und noise.

  • PDF

The Qualitative Analysis of Single Shot Fast Spin Echo (SSFSE) and Maximum Intensity Projection (MIP) on Magnetic Resonance Cholangiopancreatography

  • Park, Cheol-Soo;Cho, Jae-Hwan;Lee, Hae-Kag;Dong, Kyung-Rae;Chung, Woon-Kwan;Seok, Jong-Min;Han, Man-Seok;Lee, Sun-Yeob;Goo, Eun-Hoe;Kim, Eng-Chan
    • Journal of Magnetics
    • /
    • v.17 no.2
    • /
    • pp.138-144
    • /
    • 2012
  • 3-dimensional magnetic resonance cholangiopancreatography (MRCP) images reconstructed using the maximum intensity projection technique were analyzed qualitatively in patients diagnosed with pancreatobiliary diseases to determine their diagnostic utility. Single shot fast spin echo (SSFSE), fast spin echo (FSE) and 3-dimensional reconstructive images were acquired from 20 patients diagnosed histologically with pancreatobiliary diseases using a 3.0T MR scanner. According to qualitative analysis, the fast spin echo images and 3-dimensional reconstructed images of the hepatic duct, gall bladder and common bile duct had a higher signal to noise ratio (SNR) than the single shot fast spin echo images. Fast spin echo images and 3-dimensional reconstructed images did not show any differences. The contrast to noise ratio of the hepatic duct, gallbladder and common bile duct on the fast spin echo images and 3-dimensional reconstructed images was higher than that of the single shot fast spin echo images. The fast spin echo images and 3-dimensional reconstructed images showed similar quality.

A Study on Development of the Low Electrical Power Echo Sounder System for Coastal Use (연안목적용 저출력 어군탐지기 음향계의 개발에 관한 연구)

  • Park, Ju-Sam
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.15 no.3
    • /
    • pp.243-250
    • /
    • 2009
  • The expression of signal to noise ratio (SNR) is derived for the individual echo sounder and for the general specifications of commercial echo sounder. The SNR is depicted by several factors on transmitting and receiving, sound propagation, scattering by fishes, and mainly self ship noise. The detection ranges of echo sounders in depth and breadth are derived by finding the border of an acceptable SNR. The detection ranges are computed for the echo sounders of individual and general specifications. Generally, the detection range is lager for low frequencies. Increasing an electrical power and a diameter of transducer is not as effective for high frequencies as for low frequencies to increase the detection range. The theoretical results of the detection range can be applied to design low electrical power echo sounder for coastal use, to select an appropriate echo sounder, to know the capability of a sounder, and to interpret echograms. A method for evaluating and designing low electrical power echo sounder is developed. A universal diagram for the basic design of the low electrical power echo sounder where SNR is plotted against frequency is developed. An appropriate frequency, transducer diameter, and beam width are easily determined by using the diagram.

  • PDF

The Utility Evaluation of Reconstructed 3-D Images by Maximum Intensity Projection in Magnetic Resonance Mammography and Cholangiopancreatography

  • Cho, Jae-Hwan;Lee, Hae-Kag;Park, Cheol-Soo;Kim, Ham-Gyum;Baek, Jong-Geun;Kim, Eng-Chan
    • Journal of Magnetics
    • /
    • v.19 no.4
    • /
    • pp.365-371
    • /
    • 2014
  • The aim of this study was to evaluate the utility of 3-D images by comparing and analyzing reconstructed 3-D images from fast spin echo images of MRI cholangiopancreatography (MRCP) images using maximum intensity projection (MIP) with the subtraction images derived from dynamic tests of magnetic resonance mammography. The study targeted 20 patients histologically diagnosed with pancreaticobiliary duct disease and 20 patients showing pancreaticobiliary duct diseases, where dynamic breast MR (magnetic resonance) images, fast spin echo imaged of pancreaticobiliary duct, and 3-D reconstitution images using a 1.5T MR scanner and 3.0T MR scanner were taken. As a result of the study, the signal-to-noise ratio in the subtracted breast image before and after administering the contrast agent and in the reconstructed 3-D breast image showed a high ratio in the reconstructed image of lesional tissue, relevant tissue, and fat tissue. However, no statistically meaningful differences were found in the contrast-to-noise ratio of the two images. In the case of the MRCP image, no differences were found in the ratios of the fast spin echo image and reconstructed 3-D image.

Split-spectrum Processing for Improved Flaw Detectability by Ultrasound System ("Split-Spectrum Processing"을 사용(使用)해서 (결정립(結晶粒) 크기에 따른) 초음파(超音波) 결함판독(缺陷判讀) 개선(改善))

  • Koo, Kil-Mo;Shim, Chul-Moo;Ahn, Byeong-Wan
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.7 no.2
    • /
    • pp.8-15
    • /
    • 1988
  • A split-spectrum processing technique for an ultrasonic flaw detection system has been developed, which improves the flaw-to-grain echo ratio in large-grained materials. The enhancement is achieved by partitioning a wide-band received spectrum to obtain frequency shifted bands, which are then processed to suppress the grain echoes with respect to the flaw echo, using a novel signal minimization algorithm. A technique for suppression of grain echoes has also been devised which takes advantage of the fact that the grain echo amplitude changes with the frequency of the incident ultrasound whereas the flaw echo amplitude does not. The combination of this technique and the new flaw detection system greatly improve the capabilities of ultrasonic evaluation of large grain materials.

  • PDF

Development of rotational pulse-echo ultrasonic propagation imaging system capable of inspecting cylindrical specimens

  • Ahmed, Hasan;Lee, Young-Jun;Lee, Jung-Ryul
    • Smart Structures and Systems
    • /
    • v.26 no.5
    • /
    • pp.657-666
    • /
    • 2020
  • A rotational pulse-echo ultrasonic propagation imager that can inspect cylindrical specimens for material nondestructive evaluations is proposed herein. In this system, a laser-generated ultrasonic bulk wave is used for inspection, which enables a clear visualization of subsurface defects with a precise reproduction of the damage shape and size. The ultrasonic waves are generated by a Q-switched laser that impinges on the outer surface of the specimen walls. The generated waves travel through the walls and their echo is detected by a Laser Doppler Vibrometer (LDV) at the same point. To obtain the optimal Signal-to-Noise Ratio (SNR) of the measured signal, the LDV requires the sensed surface to be at a right angle to the laser beam and at a predefined constant standoff distance from the laser head. For flat specimens, these constraints can be easily satisfied by performing a raster scan using a dual-axis linear stage. However, this arrangement cannot be used for cylindrical specimens owing to their curved nature. To inspect the cylindrical specimens, a circular scan technology is newly proposed for pulse-echo laser ultrasound. A rotational stage is coupled with a single-axis linear stage to inspect the desired area of the specimen. This system arrangement ensures that the standoff distance and beam incidence angle are maintained while the cylindrical specimen is being inspected. This enables the inspection of a curved specimen while maintaining the optimal SNR. The measurement result is displayed in parallel with the on-going inspection. The inspection data used in scanning are mapped from rotational coordinates to linear coordinates for visualization and post-processing of results. A graphical user interface software is implemented in C++ using a QT framework and controls all the individual blocks of the system and implements the necessary image processing, scan calculations, data acquisition, signal processing and result visualization.

Spectro-Temporal Filtering Based on Soft Decision for Stereophonic Acoustic Echo Suppression (스테레오 음향학적 에코 제거를 위한 Soft Decision 기반 필터 확장 기법)

  • Lee, Chul Min;Bae, Soo Hyun;Kim, Jeung Hun;Kim, Nam Soo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.39C no.12
    • /
    • pp.1346-1351
    • /
    • 2014
  • We propose a novel approach for stereophonic acoustic echo suppression using spectro-temporal filtering based on soft decision. Unlike the conventional approaches estimating the echo pathes directly, the proposed technique can estimate stereo echo spectra without any double-talk detector. In order to improve the estimation of echo spectra, the extended power spectrum density matrix and echo overestimation control matrix are applied on this method. In addition, this echo suppression technique is based on soft decision technique using speech absence probability in STFT domain. Experimental results show that the proposed method improves compared with the conventional approaches.

Hyperacute Intracerebral Hemorrhage : Comparison of EPI and Other MR Sequence (두 개내 초급성 출혈 : EPI와 다른 MR 영상 기법의 비교)

  • 김정희;김옥화;서정호;박용성
    • Investigative Magnetic Resonance Imaging
    • /
    • v.3 no.2
    • /
    • pp.167-172
    • /
    • 1999
  • Purpose : To evaluate the detection rate of hyperacute intracerebral hemorrhage in echo planar imaging (EPI) and other MR sequences. materials and Methods : Intracerebral hemorrhage was experimentally induced in ten rats. EPI, fast spin-echo (FSE) T2 weighted images, fluid attenuated inversion recovery (FLAIR), spin-echo (SE) T1 weighted images and gradient echo (GE) T1 weight ed images of rat's brains were obtained 2 hours after onset of intracerebral hemorrhage. EPI and FSE T2 images were additionally obtained 30 min and 1 hour after onset of hemorrhage in 3 and 6 rat, repeatedly, For objective visual assessment, discrimination between the lesion and normal brain parenchyma was evaluated on various MR sequences by three radiologists. For quantitative assessment, contrast-to-noise ratio (CNR) was calculated fro hemorrhage-normal brain parenchyma. Statistical analysis was performed usning the Wilcoxon-Ranks test. Results : EPI, FLAIR, and FSE T2 images showed high signal intensity lesions. The lesion discrimination was easier on EPI than on other sequences, and also EPI showed higher signal intensity for the subjective visual assessment. In quantitative evaluation, CNR of the hemorrhagic lesion versus normal brain parenchyma were higher on EPI and FLAIR images (p<0.01). There was no difference in CNR between EPI and FLAIR (p>0.10). On MR images obtained 30 minutes and 1 hour after the onset of intracerebral hemorrhage, the lesion detection was feasible on both EPI and FSE T2 images showing high signal intensity. Conclusion : EPI showed higher detection rate as compared with other MR sequences and could be useful in early detection and evaluation of intracerebral hemorrhage.

  • PDF